Planning Board Meeting & Work Session — 2026-08-04 — Agenda
Text below is an automated extract for searching and reading. Check the original for formatting, tables, diagrams and scanned pages. Captured text is not an editorial review.
Needs text review. The last captured version is retained.
Source provenance
- Captured
- October 27, 2026 at 9:15 PM Eastern
- Original SHA-256
- d2a693e0cfd13a2e2fce352c85b6eb05b4713d4666c0f992007d3f723844ba6c
- Format
- PDF · 39 pages
Page 1
TOWN OF CORTLANDT
PLANNING BOARD
Steven Kessler, Chair Town Supervisor
Thomas A. Bianchi, Vice-Chair Town Hall, 1 Heady Street Richard H. Becker, MD
Cortlandt Manor, NY 10567
Nora Hildinger Main #: 914.734.1080 Town Board
Kevin Kobasa Fax #: 914.788.0294 James F. Creighton
Peter McKinley Cristin Jacoby
Jeff Rothfeder Planning Staff email: Robert Mayes
Karen Timko HeatherL@townofcortlandtny.gov Joyce C. White
Kellan Cantrell, Alternate
Planning Board Work Session & Meeting
Tuesday August 4, 2026
To join the meeting remotely, use this Zoom link:
https://us02web.zoom.us/j/88363365077?pwd=6rgkKAda0eu9OmQglyT0SRIfCTL7G6.1
WORK SESSION .... .................................................................................................................. 6:00 pm
Discuss items on tonight’s Planning Board Meeting Agenda.
MEETING AGENDA .............................................................................................................. 6:30* pm
1. Pledge of Allegiance
2. Roll Call
3. Changes to the Meeting Agenda, by majority vote
4. Adoption of the minutes from previous month
5. Resolution(s)
a. PB 2025-3 77 Montrose Station Rd 3-Lot Subdivision
Application of 77 Montrose Station, LLC for Final Plat approval of the proposed 3-lot
major subdivision of an approximately 9.7-acre parcel located at 77 Montrose Station
Road. Preliminary Plat approval originally granted on January 6, 2026 via Planning Board
Resolution #3-26. Final Subdivision Plat, and Subdivision and Site Plan Drawings,
revised June 17, 2026.
b. PB 2025-15 Fucci 2-lot Subdivision
Application of Joel Greenberg, R.A. on behalf of Robert Fucci for a Public Hearing, and
Preliminary and Final Subdivision approval for a 2-lot minor subdivision of an
approximately 22,000 sq. ft. parcel of property located at 12 Putnam Park Rd. Drawings
revised June 24, 2026.
6. New Business
a. PB 2026-12 44 Regina Ave | Cortlandt Self-Storage & Contractor’s Yard
Application of Cronin Engineering on behalf of Cortlandt Self-Storage LP / Mark
Giordano for an Amended Site Development Plan to construct one additional 8,000SF
storage building and an outdoor contractor’s yard. (see prior PB 3-06)
Page 2
7. Adjournment
Next Regular Meeting:
Tuesday September 1, 2026 at 6:30* PM
Agenda information is also available at https://www.townofcortlandtny.gov/
* Regular meeting will begin at the conclusion of the work session, which could be prior to 6:30 pm.
Page 3
WESTCHESTER COUNTY DEPARTMENT OF HEALTH / SOIL DATA CHART
LENGTH OF FIELDS REQUIRED
DEEP TEST DESCRIPTION BANK RUN FILL
SLOPE (LF)
WATER
LOT OF PERCOLATION IMPERVIOUS
ELEVATION CURTAIN
LOT # AREA OWTS RATE LAYER REMARKS
(IN. BELOW PER EACH
(AC.) AREA TEST HOLE (MIN./IN.) 4 BEDROOM DEPTH VOLUME DRAIN ELEVATION
DEPTH SOIL CLASSIFICATION SURFACE) ADDITIONAL
(%) NUMBER RESIDENCE (IN) (CY)
BEDROOM Tax Lot 44.17-2-18
N/F Catherine Gonzalez
EXISTING HOUSE.
SEE WCDH PERMIT
LOT 1 5.64 2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
APPLICATION FOR OWTS
(WCDH FILE#C2025-12)
D5
D6
D9
0" TO 8"
8" TO 84"
TOPSOIL
FINE SANDS W/ STONE, MOD. TO
HIGHLY COMPACTED
NONE
SOILS TESTING WAS CONDUCTED BY
CRONIN ENGINEERING AND WITNESSED BY
THE WCDH. DEEP TESTING WAS
'( D
d)
ee vey)
r
Iron Pipes in
Conc. Found SITE
Stone Wall
CONDUCTED ON NOVEMBER 4, 2024 FOR
35 '(Su
LOT 2 1.86 2% 1 TO 5 184 LF 45 LF N/A N/A N/A N/A
TOPSOIL
THE PRIMARY AND EXPANSION AREAS. 7 . 3
D7
D8
0" TO 8"
8" TO 96"
FINE SANDS W/ STONE, MOD. TO NONE
PUMPING TO THE OWTS AREA IS REQUIRED
FOR LOT 2.
67 5.7
HIGHLY COMPACTED 68
TOPSOIL
D10 0" TO 8" SOILS TESTING WAS CONDUCTED BY
D12 8" TO 84"
FINE SANDS W/ STONE, MOD. TO NONE
CRONIN ENGINEERING AND WITNESSED BY Tax Lot 44.17-2-1
HIGHLY COMPACTED
THE WCDH. DEEP TESTING WAS N/F Michael Simmon N 50° 49' 50" W
LOT 3 2.23 10% 1 TO 5 184 LF 45 LF 1 FT 110 N/A N/A CONDUCTED ON NOVEMBER 4, 2024 FOR & Jennifer Budner 138.29'
Stone Wall
TOPSOIL
THE PRIMARY AND EXPANSION AREAS.
0" TO 8" PUMPING TO THE OWTS AREA IS REQUIRED
D11 FINE SANDS W/ STONE, MOD. TO NONE
8" TO 72" FOR LOT 3.
HIGHLY COMPACTED
84
.35
1. SOILS TESTING WAS CONDUCTED BY CRONIN ENGINEERING AND WITNESS BY THE WCDH. DEEP TESTING WAS CONDUCTED ON NOVEMBER 8, 2024. PERCOLATION TESTING WAS CONDUCTED ON NOVEMBER 11 & 12, 2024. Wire Fence
'
0'
2. LOT 1 HAS A RENOVATED SINGLE-FAMILY RESIDENCE AND OWTS. AT THE TIME OF INSPECTION BY CRONIN ENGINEERING P.E. P.C., THE OWTS APPEARED TO BE OPERATING SATISFACTORILY. 30.0
3. THE HOUSE PRE-DATES ZONING AND THERE IS NO RECORD ON FILE SHOWING THE NUMBER OF BEDROOMS.
Frame Chain Link Fence
Garage 5'
ZONING DATA CHART - R-80 ( SINGLE FAMILY RESIDENTIAL) pe 34.0
Iron Pipe Found
30
elo Vicinity Map
.00
v South 0.30'
En East 0.64'
'
MINIMUM MINIMUM MAXIMUM MINIMUM MINIMUM MINIMUM MAXIMUM MAXIMUM
LOT DESCRIPTION LOT AREA LOT WIDTH HEIGHT FRONT YARD SIDE YARD REAR YARD BUILDING COVERAGE MINIMUM BUILDING FLOOR AREA ing
LANDSCAPE COVERAGE ild
(SF) (FT) (FT) (FT) (FT) (FT) (SF) (SF)
Iron Pin Bu Total Area = 423.714.89 Sq.Ft.
Found r ive
Building Envelope
1
2 2 STORIES 70% OF 50% OF FLOOR AREA OF tD
REQUIRED 80,000 200
or 35 FT.
50 30 30 65% FAR
LOT AREA PRINCIPAL BUILDING rya
ll al = 9.72 Acres
AC Units on o nW ph Stone Masonry Gate
Concrete Pad as As Ret. Wall
EXISTING LOT 44.17-1-6 42,058 174 N/A N/A N/A N/A N/A ±92 N/A eM
n
Stone Masonry Sto Stone
EXISTING LOT 44.17-1-11 381,655 596 <35 583 62 113 1,690 ±95 - Retaining Wall Retaining Wall Stepping Stone Walks
Roof Over Flag. Patio Unauthorized alteration or addition to a survey map bearing a licensed
Stone Mas. Pier Land Surveyors seal is a violation of Section 7209, Subdivision 2 of the
S
ive
HOUSE LOT 1 245,821 332 <35 170 62 113 <65% FAR ±91 -
rs r Sto ton
tD e
Line de l ne M Chain Link Fence New York State Education Law.
PROPOSED HOUSE LOT 2 80,891 267 <35 190 83 32 <65% FAR ±91 -
ng ul ha Pa M
as
as
.R
lo Bo sp vin .R et
Tax Lot 44.17-1-9 & 10 ly
A of A
Concrete 1.5 Pa g S et .W Possession only where indicated.
PROPOSED HOUSE LOT 3 97,001 235 <35 99 72 200 <65% FAR ±94 - N/F Thomas H. Hintze r al w Utility Riser Sty 2S t
tio on . W all
Irrevocable Trust Gen
e
Approximate Location Ro Re to e all
s Bay sid ry Adjacent property lines and easements not surveyed or certified.
ne of Existing 1'' Type K Copper e F
Window Co (Un nc ram
t Sto Water Service as Per ns de e # e Access to adjacent rights of way, easements and public or private lands
tru r 62.02'
en Engineering Plans ll Flag. 77 Flag
itt a Walk ct
ion Step 4'' Septic Irrigation not guaranteed or certified.
m
er W ) Control
Int ng
Cleanout
375.00'
Westchester County Department of Health i Rim=190.47 Valves
50.00' in Boulder Underground utilities shown hereon are approximate and should be
New Rochelle, New York ta Trench Stone Mas.
88
l Underground Re Drain Ret. Wall Co
Ret. Wall verified before excavating.
.12
al Propane Tank ne on Conc. 2nd Story Flagstone Fo Blo nc. 19.87' Additional underground utilities are not shown or certified.
'
"W W
S to Overhang Walk & Steps un ck
Approved pursuant to Chapter 873, Article X, Sections 873.951 and 873.1011 and
00 ne da Encroachments and structures below grade, if any, not shown or certified.
96
o
Articles VII and VIII of the Westchester County Sanitary Code subject to the provision of 3' St Roof Over Stone Mas. Flag. tio
.3
4 Flag. n
Flagstone Ret. Wall
2'
public water supply and separate sewage treatment facilities to serve each habitable 2 0° Boulder Ret. Wall Porch
Steps Walk Top Fndtn. at
Subject to covenants, easements, restrictions, conditions and agreements
S Asphalt Drive Garage Cutout
building hereafter constructed. These facilities are to be installed in accordance with land Stone Masonry EL = 186.71' of record.
improvement plans and specifications approved by and filed in this office prior to the Retaining Wall 4'' Septic
Cleanout
ge 12
Frame Trench Drain Asphalt Drive
construction of such building. Gravel Pad Garage Rim=185.83
for Generator on Concrete AS BUILT
2120, Pa y
Stone Retaining Wall 4'' Septic
a
CONCRETE Cleanout Surveyed in accordance with Deed Liber 11186, Page 287.
30
Per Dee ide Right of W
e
Each purchaser of property shown hereon shall be furnished a true copy of this plat showing riv SEPTIC TANK Rim=187.81
.00
t D Trench Chain Link Fence
al
Stone Wall
this endorsement. Any erasures, changes, additions or alterations of any kind, except the Conc. Lid Boulder
'
Elec. Drain Premises shown hereon designated on the Town of Cortlandt Tax
addition of signatures of other approving authority and the date thereof made on this plan s ph Concrete
Rim=180.46 Wall 30.00'
Meter Drain Inlet Maps as: Section 44.17, Block 1, Lot 6 & 11.
fA 4'' Septic
d Liber
UPole Apron
e
after this approval, shall invalidate this approval. o
N 36° 13' 00" W
Cleanout
ns
riv
Proposed
ai 100%
tD
m Property Line Conc. Lid Proposed Property Address: 77 Montrose Station
l
al
al
Re
50' W
Rim=180.48
ph
Expansion
W
pe Apprx.
Montrose, NY 10548
d
elo Area
g
As
Date . Conc. Lid
l
Fie
in
nv Underground Rim=180.46 Conc. Lid
ive
in
Approved by the Assistant Commissioner of Health on Behalf of the Department of Health E Electric Line Rim=180.44
ic
Dr
ta
ng MONUMENT
pt
i Junction
Re
ild lt IRON ROD
Se
Bu ha Box (.typ)
Building Envelope
4'
e
Tax Lot 44.17-1-12
NOTE:
on
l
p Junction
of
al
As 2.
5 S
W
St
Box (.typ) N/F Eugine M. Cesar-Fabian
ge
88
ld
0
e
The undersigned owner(s) do hereby consent to the filings of this map °1 & Marie Fabian
Ed
Fie
"W 1
on
As part of the Building Permit process for the initial development of all
30
LOT 1 9'
St
39
.0
Edge of Drive
ic
58 single family lots an individual Site Development Plan shall be submitted
0
0'
pt
'
West 3.00'+/- s "W
er
Se
3 End Plastic Pipe to the Division of Code Administration and Enforcement for approval by
Area = 245,818.38 Sq. Ft. uld 4°
30
of
o 1 Inv.=175.13
= 5.64 Acres fB the Director of Technical Services that is in compliant with current local
.0
Field Marking
e
o S
0
Proposed
g
End Plastic Pipe
'
w to Show End of Pipe ordinances, including among others, the Town's Tree Ordinance and Steep
Ed
Owner: 77 Montrose Station, LLC Date Ro Septic Fields as Inv.=176.66
Per Field Marking Slope Ordinance in place at the time of filing. No Building Permit shall be
UPole
T Engineering to Show
Tax Lot 44.17-1-9 & 10 EN D Plans End of
issues for any lots shown hereon until the Director of Technical Services
'
M O
.00
N/F Thomas H. Hintze S 25° 44' 00" E (Survey)
NU N R Pipe approves the Site Development Plan for same, and no Certificate of
Proposed
30
Irrevocable Trust 30.00' S 26° 00' 00" E (Deed) O 0 '
S 8.3
Occupancy shall be issued for any lots until an "as built" survey has been
M IRO .0 Property Line
30
6
75 5'
Address: 1340 Baptist Church Road, Yorktown Heights, NY, 10598 97.87' AS BUILT N 51° 26' 00" E submitted to and approved by the Director of Technical Services. The "as
°2
24 36.28'
SEPTIC FIELD
'
built" survey shall show complete information including final contours,
.00
1.
8'
7' 67
30
05
The Department Head signatures indicate that this drawing or set of drawings is consistent 1 ' floor levels, and all pertinent features.
0.
"E
e
with the Planning Board resolution of approval and with the general requirements and 29 Stone
Asphalt Driv
Bu
policies of the Town of Cortlandt for which the Department Head is responsible. The o pe Retaining Wall ildin
project design including all public health and safety considerations are solely the v el g
En
En velo X-Cut Found
responsibility of the design professional who has signed and sealed the drawings. Proposed g
in pe South 0.48'
ild
30
Property Line Bu e e East 1.04'
.0
Remains of
Properties Not riv op
0'
l
Reviewed by the Department of Environmental Services Contiguous ltD ve Properties Not Contiguous
Proposed Septic Tank h a En Proposed - Gore Strip Exists
p ng
As
S 35° 42' 00" E
R=293.51' and Pump Chamber i Septic Fields as
i ld Per N 35° 22' 00" W
30
L=112.50' as Per Engineering Bu
.0
Engineering 60.40'
0'
Plans Plans
Director Date S 31° 51' 50" W (Survey) Approximate Location
S 31° 35' 50" W (Deed) of Existing 1'' Type K Copper
Water Service as Per
Reviewed by the Department of Planning & Community Development 126.47' (Survey) Engineering Plans 3"W
135.26 (Deed) ' 4
31
Stone Wall
°
Building Envelope
Building Envelope
1 4
S
Director Date
0'
171.00'
Reviewed by the Planning Board Engineer
Tax Lot 44.17-2-3 50.0
Building Envelope
N/F Anne Sumers e
riv
30.
N 35° 42' 07" W
Deed Control # 442250322 UPole l tD
00'
l ha 336.41'
Engineer Date al s p LOT 3
LOT 2
New Property Line
W A
e
rive
on MONUMENT
St Area = 97,005.91 Sq. Ft.
S 35° 42' 00" E
N 35° 42' 00" W
IRON ROD Area = 80,890.60 Sq. Ft.
D
= 2.23 Acres
Asphalt
= 1.86 Acres
all
Approved by Resolution No. _______of the Planning Board of the Town of Cortlandt, Proposed
W
Tax Lot 44.17-1-16
New Property Line
New York, on the ______ day of ____________________ , 20_____ subject to all Septic Tank
ne
and Pump N/F Reid Gearhart
requirements and conditions of said resolution.
Sto
Chamber & Tiziana Mohorovic
Proposed 1'' Type K Copper
Per
243.86' (D ey)
Any change, erasure, modification or revision in this plat or site development plan, after as Per
eed)
Water Service as Per
50' ed Lib
30.00' Deed Liber #12229, Page #339
urv
the above date, shall void this approval. Engineering
De
Engineering Plans 30.00' 30.00' Plans
Wid er
243.23' (S
30.00' 30.00'
Signed this______ day of________________________ , 20_____ by
e R 2120
velope
336.41'
Building Envelope
Building Envelope
igh
30.00'
t of , Page
Building En
Wa
Chairperson of the Planning Board Proposed Access
UPole
ll 8.96'
and Utility Easement
y 12
199.48'
for the Benefit of Lot 3 '
Over Lot 2 .96
136
Stone Wa10
Building Envelope
Building Enve
ive
W lope
5"
all
2' 4
lt Dr
Stone Masonry 6° 5 Proposed 1'' Type K Copper
W
pe
0" E
lo S3 Water Service as Per Engineering
N 36° 57' 00" W
Pier
70.54'
ne
nve
ha
gE Plans
50.00'
Sto
S 28° 14' 4
ldin
Asp
Properties Not Contiguous
Bu i FINAL
50.00'
Apprx. Location of Water - Overlap Exists
Frame Stone
Shed Mas.
Meter Pit as Per Engineer S 34° 17' 00" E Guy
Stone Mas. Wall
MONUMENT IROD 25.39'
Stone Wall 59.05' 72.32' Stone Wall
Wire
55.60'
SUBDIVISION PLAT
Wall 182.80'
Stone N 55° 43' 00" E 153.35' UPole 72.32' UPole
N 60° 15' 00"
E
PREPARED FOR
Retaining Stone Wall
50.
N 53° 26' 00" E Wall
alt
N 50° 37' 00" E UPole Edge of Asphalt UPole Edge of Asphalt 77 MONTROSE STATION, LLC
00'
36.37' f A sph Stone
Masonry
41.26' MONTROSE STATION ROAD UPole
SITUATE IN THE
N 42° 45' 00" E eo
ll Edg Pier Edge of Asphalt
Edge of Asphalt
23.03' Wa Drain Inlet TOWN OF CORTLANDT
MONUMENT ne
IRON ROD Sto lt UPole Rim=145.17 N 56° 26' 00" E Approximate Location of WESTCHESTER COUNTY, NEW YORK
s pha N 53° 38' 00" E 127.92' Existing 16" Cast Iron Water Main
of A N 31° 21' 00" E
UPole E dge 60.82' as Per Engineering Plans
91.39' Approximate Location of SCALE: 1" = 40'
Existing 16" Cast Iron Water Main
UPole as Per Engineering Plans
Stone Retaining
Wall
N 37° 28' 00" E
33.36'
Westchester County Index System: Sheet 222, Block 10399
I, Daniel T. Merritts Licensed Land Surveyor, who made this map do
hereby certify that the survey upon which this map is based was completed Utility Design By:
COPYRIGHT C 2026
TC MERRITTS LAND SURVEYORS
TC MERRITTS LAND SURVEYORS April 1, 2025 and that this map was completed January 27, 2026.
Map Revised: June 1, 2026; June 5, 2026; June 17, 2026
Cronin Engineering
Project: Reference:
ALL RIGHTS RESERVED, UNAUTHORIZED DUPLICATION OR 24-188 N/A
ELECTRONIC TRANSMISSION WITHOUT PRIOR PERMISSION 394 BEDFORD ROAD ● PLEASANTVILLE ● NY 10570 Field Survey By: Drawn By:
● survey@tcmerritts.com
IS A VIOLATION OF APPLICABLE LAWS.
(914) 769-8003 By:
PR/JC/BFC BJC/BFC/CP
N.Y.S. Licensed Professional Engineer No.087679 Date
New York State Licensed Land Surveyor No.050604 Patrick M. Bell, P.E. Project Manager: Checked By:
THOMAS C. MERRITTS LAND SURVEYOR PC BFC BFC
Page 4
SUBDIVISION & SITE DEVELOPMENT PLAN
Tax Lot 44.17-2-18
N/F Catherine Gonzalez
77 MONTROSE STATION, LLC Cortlandt
TR
A
VI
d)
SITE
S
ee y) RD
LN
'(D urve N
TOWN OF CORTLANDT
5 I O
3 S AT
7. 3'( ST
67 5.7 SE
N 50
68 RO
WESTCHESTER COUNTY, NEW YORK
NT
O
M
° 49
' 50"
Tax Lot 44.17-2-1
N/F Michael Simmon
W
& Jennifer Budner
Wire Fence
138
OA
KR
D
.29'
L RD
GE HIL
COLLE
Frame
Shed
riv
e LOCATION MAP SCALE: 1" = 600'
D
el
GENERAL NOTES G
ra
v
1. PARCEL TAX MAP DESIGNATION: SECTION: 44.17, BLOCK: 1, LOT(S): 6 & 11
2. TOTAL AREA OF EXISTING LOTS: 423,713 SQ. FT. (9.73 ACRES).
e
EXISTING LOT 6: 42,058 (0.97 ACRES) Lin
EXISTING LOT 11: 381,655 SQ. FT. (8.76 ACRES).
ong e
Al riv
ly D
3. SURVEY INFORMATION SHOWN HEREON IS BASED ON A SURVEY PREPARED BY TC MERRITTS LAND SURVEYORS ENTITLED al
er lt
"PRELIMINARY MAP PREPARED FOR STEVE GIORDANO BUILDERS, INC." DATED JULY 12, 2024, LAST REVISED AUGUST 28, 2024. en Tax Lot 44.17-1-12
Tax Lot 44.17-1-9 & 10 sG ha N/F Eugine M. Cesar-Fabian
4. TOPOGRAPHY SHOWN HEREON IS BASED ON DATA DOWNLOADED FROM THE WESTCHESTER COUNTY GIS WEBSITE. N/F Thomas H. Hintze ne sp EX & Marie Fabian
Irrevocable Trust t o A IS
tS n RE 5-BD TIN
e SI R G
5. PARCEL IS LOCATED IN THE FOLLOWING DISTRICTS: itt DE M
m NC
- TOWN OF CORTLANDT R-80 (SINGLE-FAMILY RESIDENTIAL) ZONING DISTRICT er
Int
E
- HENDRICK HUDSON SCHOOL DISTRICT
- CORTLANDT CONSOLIDATED WATER DISTRICT l
al
88
- MONTROSE FIRE DISTRICT
W EX
'
ne GA IST
19.87'
W
to
"
6. PARCEL IS LOCATED IN THE HUDSON RIVER WATERSHED. 00 RA ING
43
' S GE
°
ENGINEER'S NOTES S
20
50 0 25 50
375.00'
e
Stone Wall
1. THERE SHALL BE NO MODIFICATION TO ANY ASPECT OF THIS PLAN WITHOUT CONTACTING THE DESIGN ENGINEER. m e
a g
Fr ara
G
2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL CODES, RULES & 50' Wide Right of Way
REGULATIONS. Per Deed Liber 2120, Page 12
SCALE: 1" = 50 FT.
50'
3. IT IS THE OWNERS RESPONSIBILITY TO INSURE THAT ALL IMPROVEMENTS ARE PLACED ON MATERIAL WITH A SUITABLE
BEARING CAPACITY.
N 36° 13' 00" W
4. CONTRACTOR TO VERIFY DEPTH & LOCATION OF ALL UTILITIES INCLUDING WATER, SEWER, DRAINAGE, GAS, TELEPHONE,
Tax Lot 44.17-1-9 & 10 OWNER/APPLICANT
N/F Thomas H. Hintze
e
ELECTRIC & CABLE PRIOR TO START OF WORK.
riv
Irrevocable Trust
tD
ll e
al
SPECIAL NOTES a riv 77 MONTROSE STATION, LLC
ph
W tD
e al 1340 BAPTIST CHURCH ROAD
As
on ph
1. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE MEANS AND METHODS NEEDED TO PERFORM THE Edge of Drive St As YORKTOWN HEIGHTS, NY 10598
CONSTRUCTION/EXCAVATION, ET AL, OPERATIONS SHOWN HEREON. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR West 3.00'+/- 54
'
TO PROVIDE A SAFE WORKING ENVIRONMENT AND PROVIDE THE MEANS AND METHODS TO PERFORM THE NECESSARY 2.
10
TASKS. NOTHING ON THESE PLANS SHALL OBLIGATE THE DESIGN ENGINEER AS TO THE MEANS AND METHODS TO PERFORM Tax Lot 44.17-1-11
THE TASKS ASSOCIATED WITH THE APPROVED DESIGN PLANS. THOSE OBLIGATIONS AT ALL TIMES REMAIN WITH THE
CONTRACTOR(S).
· UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
sphalt Drive
24
1.
S 25° 44' 00" E (Survey) 67 UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
'
S 26° 00' 00" E (Deed) ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
97.87' ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
68
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
.2
6'
PROPOSED LOT 1 DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
Remains of A
245,821 SF · COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
SITE CAPACITY ANALYSIS PROPOSED LOT LINES (TYP.) ENGINEERING". ALL RIGHTS RESERVED.
· AUTHORIZATION No. 130827
ZONING DISTRICT R-80 N 51° 26' 00" E
36.28' REVISIONS
N 35° 22' 00" W
5
60.40'
LOT # SEC: 44.17, BLOCK: 1, LOT: 6 + 11 PROPOSED LOT LINES (TYP.) 4 UPDATE FOR FINAL SUBD APPROVAL JUNE 17, 2026
R=293.51' ' 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
.15
TOTAL APPROXIMATE GPA IN ZONE 423,713 SF 9.73 AC L=112.50' 2 90
2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
Stone Wall
WETLAND (WWW) 0 SF 0 AC
S 31° 51' 50" W (Survey) 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
50% OF 100' WETLAND BUFFER AREA 0 SF 0 AC S 31° 35' 50" W (Deed)
126.47' (Survey) PROPOSED LOT 3 # REASON DATE
SLOPES > 20% (SS) 140,085 SF 3.22 AC 97,001 SF
135.26 (Deed)
MUNICIPAL TAX IDENTIFICATION:
NYSDEC WETLAND (FW) e Tax Lot 44.17-1-16
0 SF 0 AC d PROPOSED 4-BEDROOM
osed riv N/F Reid Gearhart
SECTION: 44.17
171.00'
0' x p e D RESIDENCE
50.0 E & Tiziana Mohorovic
lly gat t PROPOSED
al
100 YEAR FLOODPLAIN (FD) 0 SF 0 AC GARAGE 171.0
rtia rru ASPHALT
Pa " Co Pipe h 1ST FL 172.5
Deed Liber #12229, BLOCK: 1
sp
336.83'
TOTAL CONSTRAINED AREA 0 SF 0 AC 10 etal BASEMENT 162.5 DRIVEWAY
Page #339
M ll A
a LOT: 6 & 11
W
one WALKWAY SUBLOT: -----
283,628 SF
St
e
PARCEL AREA AFTER CONSTRAINTS 6.51 AC
lt Driv
RO
DRAWN BY: AD
10% OF PARCEL AREA AFTER CONSTRAINTS N.A. N.A.
CHECKED: KS/PMB
Aspha
NET PARCEL AREA (NPA) 283,628 SF 6.51 AC RO
SM PROJECT: 77 MONTROSE STATION RD
R-80 RESIDENTIAL DENSITY PERMITTED
N 35° 42' 00" W
50' Wide Right of Way
243.86' (D vey)
PROPOSED LOT LINES
eed)
3.55 LOTS = 3 LOTS MAX Per Deed Liber 2120, Page 12 EXPIRATION DATE: 03-31-2027
(TYP.) DATE: JANUARY 22, 2025
ur
(80,000 SF. / LOT MIN. REQUIRED)
PATRICK M. BELL, P.E.
243.23' (S
PROPOSED 4-BEDROOM
PROPOSED LOT 2
RESIDENCE
WO 80,891 SF PROPOSED
GARAGE 162.0
JOB #: 240601 LICENSE #087679
SM ASPHALT
WO 1ST FL 163.5
PROPOSED ACCESS & UTILITY DRIVEWAY BASEMENT 153.5
RO
Tax Lot 44.17-1-6 EASEMENT FOR THE BENEFIT
199.48'
C N N
OF LOT 3 OVER LOT 2
Tax Lot 44.17-2-3 SM
SM WALKWAY
N/F Anne Sumers
108.96'
Deed Control # SM
Stone Wall
WO 6'
442250322 136
.9
SM SM
N N N
rive
SM SM
alt D
Frame
70.54'
N 50° 37' 00" E
45"
W RO NAL N N N C N L N
Shed 52' WO
40" E
N 36° 57' 00" W
41.26'
h
6°
S3
Asp
SM (914) 736-3664
S 28° 14'
S 34° 17' 00" E RO RO
25.39' 59.05' 72.32'
Stone Wall 153.35' Stone Wall 127.92' Guy
N 55° 43' 00" E N 56° 26' 00" E Wire
SITE LOCATION 182.80'
39 Arlo Lane
N 31° 21' 00" E N 60° 15' 00
"E Properties Not Contiguous
N 53° 26' 00" E 91.39' - Overlap Exists
36.37' N 42° 45' 00" E
lt N 53° 38' 00" E Stone Wall Cortlandt Manor, New York 10567
23.03'
l l A s phaStone 60.82'
MONTROSE STATION ROAD
Wa f Masonry
N 37° 28' 00" E
eo Edge of Asphalt
Edg
33.36'
ne Pier Edge of Asphalt
Stone Sto alt
Retaining
of A
sph COVERSHEET
Wall e
Edg ENTRANCE SHALL BE LIST OF DRAWINGS
LOCATED AT HIGH POINT
SHEET TITLE SHEET NUMBER TITLE ISSUE DATE LAST REVISED
SUBDIVISION &
CS-1.1 1 OF 8 COVERSHEET 1/22/2025 6/17/2026
SITE DEVELOPMENT PLAN
PROPOSED SUBDIVISION LAYOUT EX-2.1 2 OF 8 EXISTING CONDITIONS / TREE REMOVAL PLAN 1/22/2025 6/17/2026 FOR
SCALE: 1" = 50' TP-2.2 3 OF 8 TREE REMOVAL OVERLAY 8/20/2025 6/17/2026 77 MONTROSE STATION, LLC
SP-3.1 4 OF 8 PRELIMINARY SUBDIVISION PLAT 1/22/2025 6/17/2026
TOWN OF CORTLANDT ZONING MAP
NTS UTILITY + GRADING PLAN /
UG-4.1 5 OF 8 1/22/2025 6/17/2026
INTEGRATED PLOT PLAN
LOCATION:
UTILITY + GRADING PLAN / 77 MONTROSE STATION ROAD
UG-4.2 6 OF 8 1/22/2025 6/17/2026
DRIVEWAY PROFILES TOWN OF CORTLANDT, NEW YORK
EROSION CONTROL + TREE PLAN /
ESC-4.1 7 OF 8 1/22/2025 6/17/2026
CONSTRUCTION DETAILS
CD-5.1 8 OF 8 CONSTRUCTION DETAILS 1/22/2025 6/17/2026
SHEET 1 OF 8 CS-1.1
Page 5
SLOPE ANALYSIS
TREE REMOVAL AND PROTECTION NOTES TREE TABLE )
ed )
SLOPE RANGE AREA (SF) '( De rvey
1. ALL REMOVAL OF TREES ON PROPERTY ARE TO BE MINIMIZED AND SHOULD BE TAGGED BY THE APPLICANT AND 35 Su
INSPECTED BY THE TOWN OF CORTLANDT PRIOR TO CUTTING. TREE WELLS SHOULD BE CONSTRUCTED AROUND ALL PROPOSED LOT 2 PROPOSED LOT 3 TOTAL 7 7. 73'(
0 - 15% 242,000 6 5.
TREES THAT COULD BE IMPACTED AS A RESULT OF CUTTING AND FILLING.
N 50
68
EXISTING TREES 248 254 502
2. ALL TREES DESIGNATED FOR PRESERVATION SHALL BE CLEARLY MARKED WITH A BRIGHT COLORED RIBBON OR 15% - 30% 131,063
° 49
OTHER EASILY DISCERNIBLE METHOD. TREES TO BE REMOVED 150 67 217
' 50"
> 30% 50,650 Tax Lot 44.17-2-1
3. TREES TO BE PROTECTED SHALL BE PROVIDED WITH FENCING OR TRUNK ARMOR AS DETAILED ON THIS PLAN. ALL TREES TO REMAIN 98 187 285 N/F Michael Simmon Cortlandt
W
TREE PROTECTION METHODS SHALL CONFORM TO CHAPTER 5.190 OF THE WESTCHESTER COUNTY " BEST & Jennifer Budner
MANAGEMENT PRACTICES MANUAL SERIES FOR EROSION AND SEDIMENT CONTROL", 1991. THESE GUIDELINES SHALL TREES TO BE PLANTED: 12
BE IMPLEMENTED FOR ALL TREES DESIGNATED FOR PROTECTION.
SOILS TABLE
TR
'
.35
A
VI
SITE
S
TREE NOTE RD
84
LN
4. ALL TREES WITHIN SEPTIC AREA SHALL BE REMOVED AS REQUIRED BY THE W.C.D.H. I O
N
AT
Wire Fence
138
ST
REFERENCE IS MADE TO THE TREE REPORT PREPARED BY SE
Stone Wall
5. ALL TREE STUMPS SHALL BE REMOVED FROM THE SITE IN A LAWFUL MANNER OR GRINDED ON SITE AND USED FOR SOIL PERCENT RO
SOIL NAME
.29'
SYMBOL OF LOT SAVATREE DATED OCTOBER 3, 2024. NT
LANDSCAPING PURPOSES ONLY. M
O
6. WOOD CHIPS SHALL BE STOCKPILED ONLY FOR USE IN LANDSCAPING AND DECORATIVE PURPOSES. WOOD CHIPS
CHARLTON-CHATFIELD COMPLEX,
NOT FOR THESE PURPOSES SHALL BE REMOVED FROM THE SITE IN A LAWFUL MANNER. CrC 58%
5'
34.0
0 TO 15% SLOPES, VERY ROCKY
7. WOOD CHIPS AND STUMP CHIPS SHALL NOT BE USED FOR ANY FILLING OR BACKFILLING OPERATION. Frame
CHATFIELD-HOLLIS-ROCK Shed
CuD OUTCROP COMPLEX, 15 TO 35 25% e
CuD
8. ALL CUT LOGS SHALL BE REMOVED FROM THE SITE IN A LAWFUL MANNER OR USED FOR DECORATIVE PURPOSES
PERCENT SLOPES riv
ONLY. CUT LOGS SHALL NOT BE STOCKPILED FOR MORE THAN 30 DAYS NOR USED FOR FILLING OR OR BACKFILLING lD OA
KR
PURPOSES. ve
D
CHATFIELD-HOLLIS-ROCK
ra
0'
L RD
3.0
CtC OUTCROP COMPLEX, 0 TO 15 9% G COLLE
GE HIL
11
PERCENT SLOPES
SUBDIVISION CONSTRUCTION SCHEDULE
Sh SUN LOAM 8%
LOCATION MAP SCALE: 1" = 600'
e
NOTES: g
Lin
e
CtC
1. FILE ANY PERTINENT DOCUMENTS WITH THE TOWN BUILDING DEPARTMENT, TOWN HIGHWAY DEPARTMENT AND
on
1. PERMITTEE IS TO MAINTAIN WORK ZONE TRAFFIC CONTROL PLAN IN
Al riv
CrC
ANY OTHER INVOLVED AGENCY. OBTAIN A SEWAGE DISPOSAL SYSTEM PERMIT FROM THE WCDH. ACCORDANCE WITH SECTION 104 OF HIGHWAY LAW, WHILE ly D
WORKING WITHIN THE TOWN RIGHT-OF-WAY. ral
2. OBTAIN REQUIRED BUILDING PERMIT, ROAD OPENING PERMIT, EXCAVATION PERMIT OR ANY OTHER PERMIT 2. ROAD CLOSURES ARE NOT PERMITTED.
e ne lt Tax Lot 44.17-1-12
3. OVERNIGHT EXCAVATION WILL NOT BE PERMITTED. Tax Lot 44.17-1-9 & 10 G ha
es N/F Eugine M. Cesar-Fabian
REQUIRED FOR THE CONSTRUCTION OF THE RESIDENCE.
N/F Thomas H. Hintze n sp & Marie Fabian
Irrevocable Trust to A EX
tS
IS
3. CONTACT THE UNDERGROUND LINE LOCATION SERVICE (CODE 53) AT 800-245-2828. INSTALL THE LIMITS OF RE 5-BD TIN
en SI R G
DISTURBANCE FENCING (ORANGE CONSTRUCTION FENCING). itt DE M
NC
m
er
62.02'
E
4. THE HOUSE AND DRIVEWAY LOCATIONS SHALL BE STAKED OUT, WITH OFFSETS, BY A LICENSED LAND SURVEYOR. In t
'
l
.12
5. TREES TO BE PRESERVED ARE TO BE CLEARLY MARKED AND PROTECTED FROM CONSTRUCTION. al
88
88
W
'
e EX 19.87'
on
W GA IST
'
6. INSTALL ALL REQUIRED EROSION CONTROL STRUCTURES PER THE PLANS. "
.32
St
' 00 RA ING
GE
96
° 43
7. CLEAR AND GRUB AREAS PROPOSED FOR CONSTRUCTION, INCLUDING THE HOMESITE, DRIVEWAY, AND SEPTIC 20
S
AREA. CHIP BRANCHES AND LOGS AS PRACTICABLE AND REMOVE STUMPS AND UNUSED LOGS AND OTHER DEBRIS
FROM THE SITE IN A LAWFUL MANNER.
CtC
375.00'
e
Stone Wall
m e
8. BEGIN SITE EXCAVATIONS AND FILLING OPERATIONS FOR THE ROUGH GRADING OF THE LOTS. r a rag 351 40 0 20 40
F a
G
50' Wide Right of Way
9. CONSTRUCT FOOTING FORMS AND HAVE SAME APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCT Per Deed Liber 2120, Page 12 352
FOUNDATION WALLS AND HAVE SAME INSPECTED AND APPROVED. PROCEED WITH CONSTRUCTION OF HOUSE IN 50' 353 SCALE: 1" = 40 FT.
ACCORDANCE WITH ALL BUILDING DEPARTMENT REQUIREMENTS.
356 354
10. INSTALL SEWAGE DISPOSAL SYSTEMS PER SEWAGE DISPOSAL PLAN APPROVED BY THE WCDH. SAME SHALL BE 357
N 36° 13' 00" W
INSPECTED AND APPROVED BY THE WCDH PRIOR TO BACKFILL. ALL SEWAGE DISPOSAL SYSTEMS SHALL BE OWNER/APPLICANT
CuD
Tax Lot 44.17-1-9 & 10 358
INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND ALL WCDH REQUIREMENTS. N/F Thomas H. Hintze Edge of Drive
CrC
e
355
riv
Irrevocable Trust West 3.00'+/-
tD
11. INSTALL ROOF LEADER LINES AND FOOTING DRAIN LINES PER THE APPROVED PLANS. 359 77 MONTROSE STATION, LLC
ll
ive
458
al
a 442 457
Dr 1340 BAPTIST CHURCH ROAD
CrC
ph
W 441 363 360
t
al
12. COORDINATE WITH UTILITY COMPANIES FOR THE INSTALLATION OF THE UNDERGROUND UTILITIES. UPON 455
ne YORKTOWN HEIGHTS, NY 10598
362
As
COMPLETION OF THE SEWAGE DISPOSAL SYSTEM AND HOUSE, LOT TO BE FINAL GRADED. TOPSOIL TO BE PLACED
Sh o ph
WHERE NECESSARY AND SEEDED AND MULCHED. St As 443 456 452 361
454 367
439 365
13. CONTINUAL INSPECTION AND MAINTENANCE OF THE EROSION CONTROL DEVICES IS REQUIRED. DISTURBANCE 445 453
438 440 444 451
OUTSIDE OF THE LIMITS OF DISTURBANCE FENCE IS NOT PERMITTED.
Tax Lot 44.17-1-11 364 368
370 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
0
437 366
16
446 450 372
SOIL BOUNDARY TYP. UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
14. COMPLETE THE DRIVEWAY PER THE PLAN SPECIFICATIONS. 436 369 ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
422 433 434 435 373
449 ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
432 447 374 375
halt Drive
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
0
15. PROVIDE THE NECESSARY PLANTINGS AND GENERAL CLEAN UP OF THE LOT OBTAIN A CERTIFICATE OF 423
16
448 377 371
430 431
S 25° 44' 00" E (Survey) DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
OCCUPANCY. 420 459
S 26° 00' 00" E (Deed) 421 426 379
· COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
424 425 376 398 ENGINEERING". ALL RIGHTS RESERVED.
97.87' 486 378 396
490 489 487 427 461 · AUTHORIZATION No. 130827
469 460
395 397
sp
485 409
488 491 428 470 462 380 REVISIONS
Remains of A
468 410 399
CuD 492
541
543 542 540 539 538 484 429
466
463
464
407
381 382
394 400
5
493 544 476 471 412 408 383 392 4 UPDATE FOR FINAL SUBD APPROVAL JUNE 17, 2026
CtC
551 405 401
CrC
390
180 465 FEBRUARY 6, 2026
546 545 411 N 51° 26' 00" E 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION
550 483
CrC 482 481 472 467 404 403 393
384 36.28'
2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
495 549 528 406 388
548 547 478
N 35° 22' 00" W
DRIP LINE
389391
Sh 527 385 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
480 473 474 419
60.40'
494 529 413 349
PROTECTIVE
530 526 417 387 # REASON DATE
DEVICE
565 522 477 386
496 511 534 479 350
LIMITS OF 525 157 418 348 MUNICIPAL TAX IDENTIFICATION:
R=293.51' 497 415
CLEARING AND
533 521 156 347
GRADING L=112.50' 566 498 510 536 209 416 333 SECTION: 44.17
532
Stone Wall
567 535 523 332 346
15 562 499 512 524 414 BLOCK: 1
0 502 509 158 155 0
S 31° 51' 50" W (Survey) 531 159 154 210 17 344
513 208 337 338 LOT: 6 & 11
S 31° 35' 50" W (Deed) 564 500 508 345 PROPOSED TREES TO BE
CrC
561 516 517 519 160 343 341 REMOVED TYP.
PROPOSED
126.47' (Survey) 501 514 207 475 SUBLOT: -----
GRADING 563 150
151 331
505 206
135.26 (Deed) 560 518 152 402 DRAWN BY: AD
342
503 515 147 144 153 213
336 339
327 Tax Lot 44.17-1-16
5'
d e 507 149 212 330
riv
328
osed 558 506 161 334 N/F Reid Gearhart CHECKED: KS/PMB
MIN.
137 204 203
171.00'
' p 559 145 520
tD
0.00 x e 163 & Tiziana Mohorovic
5 ly E at l 504 139 146 205 340
rt ial rrug a 136 138 148 218219 329 326 PROJECT: 77 MONTROSE STATION RD
Pa " Co Pipe h 557 170 169 162 164 335 Deed Liber #12229,
sp 320
556 EXPIRATION DATE: 03-31-2027
10 etal 197 201 211 217 325 319 Page #339
DATE: JANUARY 22, 2025
M ll A 140 141142
143 165 221 PATRICK M. BELL, P.E.
a 135
134 214
216 324 317 318 JOB #: 240601 LICENSE #087679
W 555 166 202 220
ne 52 168 199 200 321
10'' CMP o 51 167 196 198
St
e
552 133 193 160 316 315
Inv=137.28
lt Driv
C N N
100 222
Sh 194 215 322 314
DRIP LINE 554 103 99 171 186 323
SNOW FENCE 102 101 192
53 54 50 129 132104 98 313
Aspha
172 195 189 191 223
187 312
224
553 128
131
94
93
173
188
190
242 226 231 N N N
N 35° 42' 00" W
50' Wide Right of Way 49 105 97 174 244
243.86' (D vey)
41 42 96 183 230
eed)
Per Deed Liber 2120, Page 12 47 55 95 181 243 240
184 NAL N N N C N L N
ur
40 109 245 225
243.23' (S
110 92 229 (914) 736-3664
48 56 43 182 241 227 228
106 107
CrC
126
185 233
170
CuD 57 111 91 180 239 232
127 246
CrC
234
CORD FENCE
Tax Lot 44.17-1-6 58 59 44
46
45 108
89
90 CrC 176178 179 256 238 235 300
311
39 Arlo Lane
125 255 248 247 298
BOARD FENCE
Tax Lot 44.17-2-3 249 Cortlandt Manor, New York 10567
N/F Anne Sumers 60 120 122
124
175 301 309 310 307306
88 299
CrC
61 121 112 177 257 237
CORRECT METHODS OF TREE FENCING
130 250
108.96'
Deed Control # 39 62 115 87
Stone Wall
442250322 38 123 86 254
295 294 236 308 EXISTING CONDITIONS /
TREE AND ROOT PROTECTION 118 258 293 302
e
116 114 253 251 259 305 TREE REMOVAL PLAN
37 117 292
Driv
1. CONSTRUCTION EQUIPMENT, TRUCKS OR OTHER VEHICLES SHOULD 113 150
260 303
Sh
NOT BE PARKED OR OPERATED UNDER THE CANOPY OF TREES 13 252 270
TO BE SAVED.
Frame 12 N 50° 37' 00" E 66 70 71 82 297 269 304
t
85
l
2. PETROLEUM PRODUCTS AND CHEMICALS SHOULD NOT BE STORED, 119 290
a
Shed 65 16 84 296 291 287
40" E
N 36° 57' 00" W
SPILLED, OR DUMPED UNDER PROTECTED TREE CANOPIES. 41.26' 0
sph
3. EXCAVATION OR STOCKPILING BENEATH PROTECTED TREES IS NOT 1 6 14
67 68 69 26
36 72 83 81
289
288 284 SUBDIVISION &
ACCEPTABLE. 267
A
11
5 19 30 1 4 0 283
SITE DEVELOPMENT PLAN
S 28° 14'
4. IN NO CASE SHALL BOARDS OR FENCES BE NAILED TO PROTECTED
64 25 266
CrC
15 80 282
TREES.
2 100 9 15 63 21 23 24
28
261 268 271 275 286
N.T.S. 3
7
8 16 Wall
17 Stone 18 20153.35'
22 27 35
29 34Stone
Wall 127.92' 73
74 75
79
Guy 273 274 285
FOR
N 55° 43' 00" E 262 263 264 265 276
TREE PROTECTION FENCING INSTALLATION N 31° 21' 00" E
N 56° 26' 00" E Wire 182.80' 272 281
280
77 MONTROSE STATION, LLC
4 33 76 78
N 60° 15' 00 Properties Not Contiguous
N 53° 26' 00" E 91.39' 32 31 77
"E
277 - Overlap Exists
N 42° 45' 00" E Drain Inlet 279 Stone Wall
altStone
36.37' N 53° 38' 00" E
Rim=145.17
23.03'
s p h 60.82'
ll fA
MONTROSE STATION ROAD
Wa UPo278
N 37° 28' 00" E Masonry le LOCATION:
eo Pier Edge of Asphalt
Edg
33.36' Typ.
one
77 MONTROSE STATION ROAD
Stone St UPole WATER Edge of Asphalt
alt Typ. VALVE TYP TOWN OF CORTLANDT, NEW YORK
Retaining Wall
fA sph EXISTING CONDITIONS /
HYDRANT
eo
Edg TREE REMOVAL PLAN SHEET 2 OF 8 EX-2.1
SCALE: 1" = 40'
Page 6
)
ed )
' ( De rvey
TREE TABLE 7
35 Su
7. 73'(
6 5.
N 50
68
PROPOSED LOT 2 PROPOSED LOT 3 TOTAL
° 49
EXISTING TREES 248 254 502
' 50"
TREES TO BE REMOVED 150 67 217
W
Cortlandt
TREES TO REMAIN 98 187 285
'
.35
TR
A
84
VI
SITE
S
RD
LN
Wire Fence
138
N
I O
AT
Stone Wall
= EXISTING TREE TO REMAIN ST
.29'
SE
RO
NT
O
M
5'
= EXISTING TREE TO BE REMOVED 34.0
Frame
Shed
e
= TREE RECOMMENDED FOR REMOVAL BY SAV-A-TREE riv
lD
PER OCT. 3, 2024 REPORT (TOTAL # = 107)
ve OA
KR
ra
'
.00
D
G
3
L RD
11
GE HIL
COLLE
e LOCATION MAP SCALE: 1" = 600'
Lin
g e
on
Al riv
ly D
ral
e ne lt
sG ha
ne sp
to A EX
tS
IS
RE 5-BD TIN
en SI R G
itt DE M
S
APPROXIMATE NC
N
rm
62.02'
E
e LOCATION OF
Int UNDERGROUND
PROPANE TANK
'
l
.12
al
88
88
S
W
C
'
e EX 19.87'
on
W GA IST
'
"
.32
St
' 00 RA ING
GE
96
° 43
20
S
S
N
APPROXIMATE LOCATION e
Stone Wall
m e
OF WATER SERVICE
r a rag 351
SHUT OFF VALVE F a 40 0 20 40
G
S
C
APPROXIMATE LOCATION
OF EXISTING 1" TYPE K
352
50' COPPER WATER SERVICE 353
SCALE: 1" = 40 FT.
356 354
STONE WALLS TYP. 357
N 36° 13' 00" W
358 OWNER/APPLICANT
EXPANSION
Edge of Drive
e
355
AREA
100%
riv
West 3.00'+/-
tD
359
ll
1
ive
6.7
458
al
a 77 MONTROSE STATION, LLC
17
4
442 457
Dr
6.4
1
17
ph
363
6.0
W lt 441 360
7
17
455 1340 BAPTIST CHURCH ROAD
5.6
ne a 362
17
2
As
5.5
ph
17
9
YORKTOWN HEIGHTS, NY 10598
5.1
o s
St
0
17
443 456 361
5.0
A 452
17
'
40
367 EXISTING 100% EXPANSION
'
454
40
4' 365
'
40
439 5 AREA FOR EXISTING HOUSE
2. 445
'
40
453
'
0 444
40
438 1440 451 370
'
40
37 LF
364 368
'
41
0 437
37 LF
366
LF
16
450
'
41
446 372
37 LF
EXISTING SEPTIC AREA FOR · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
436 369
37 LF
422 433 434 435 373
PROPOSED LOT LINES (TYP.) EXISTING HOUSE. SEE WCDH UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
37 LF
432 447 449 374 375 ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
37 LF
FILE No. C2025-12
sphalt Drive
24
0
423
37 LF
ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
16
448
1. 377 371
430 431
37
S 25° 44' 00" E (Survey) 67
459 SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
37
S 26° 00' 00" E (Deed) 420 421 426
'
37
379 DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
LF
424 425 376 398
LF
97.87' · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED.
378 396
68
490 489 486 427 461 · AUTHORIZATION No. 130827
487 460
.2
469 395 397
6
485 409
'
PROPOSED LOT 1 491 488 428 470 462 380
Remains of A
468 410 399
245,821 SF
541 463 381 382 REVISIONS
492 543 542 540 539 538 484 429 464 394 400
493 466 407 5
544 476 471 412 408 383 392
551 405 390 401 UPDATE FOR FINAL SUBD APPROVAL JUNE 17, 2026
0 465 4
1 8
546 550 545 483 411 N 51° 26' 00" E
482 481 472 467 404 403 393 36.28'
3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
384
495 549 528 406 388
548 547 478
N 35° 22' 00" W
2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
527 385 389391 LIMIT OF DISTURBANCE FOR
480 473 474 419
60.40'
494 529 413 PROPOSED
349 LOTS 2 AND 3 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
37 LF
ROOF LEADER DISCHARGE 530 526 417
PROPOSED LOT LINES (TYP.) 387 (±77,100 SF / 1.7 AC)
386
37 LF
LF
PIPE 4" PVC SDR 35 565 496 522 477
37 LF
511 534 479 350 # REASON DATE
525 418
37 LF
R=293.51'
INV OUT 165.0 ' 497 157 415 348
37 LF 7'
5
INTO CULTECS 160.5 .1 156 347 MUNICIPAL TAX IDENTIFICATION:
37 L3F 7'
533 521
209 416
0
29 566 498 536
L=112.50' 510
37 L3F 7'
PROPOSED (4) CULTEC 532 333
37
SECTION:
Stone Wall
535 523 332 346 44.17
567
37
330XLHD RECHARGER 512
15 562 499 524 414
37
LF 37'
0
INFILTRATORS 502 509 158 155 0
3
531 154 210 17 344 BLOCK: 1
LF 37'
S 31° 51' 50" W (Survey) 159 338
564 17 513 208 337 PROPOSED TREES TO BE
S 31° 35' 50" W (Deed) 500 508 0 345 LOT: 6 & 11
FOOTING DRAIN DISCHARGE 561 516 517 519 160 343 341 REMOVED TYP.
126.47' (Survey) 501 514 207
PROPOSED LOT 3
331
PIPE 4" PVC SDR35 563 505 DECK 150151 475 97,001 SF SUBLOT: -----
135.26 (Deed) INV. 160.0 560 518 152 206 402
147 336 339 342
503 515 144 153 213 327 DRAWN BY: AD
se d ve PROPOSED 507
4-BEDROOM 149 161 212 330 328
o r i 558 137 506 +170.8 204 203 334
Exp ed 145 520
0' 559 RESIDENCE CHECKED: KS/PMB
50.0 lly ugat t D 504 146 163 205 340
r t ia rr a l 136 138
GARAGE 171.0 139 PROPOSED
148 329 326
Pa " Co Pipe h 557 1ST FL 172.5 ASPHALT
170 169 164 218219 PROJECT: 77 MONTROSE STATION RD
335
sp 162 320
336.83'
10 etal 556 BASEMENT 162.5 DRIVEWAY
197 201 211 217 325 319
M l l A 140 141142 143 165 221 DATE: AUGUST 20, 2025 EXPIRATION DATE: 03-31-2027
a 135 172.0+ 214
216 324 317 318 PATRICK M. BELL, P.E.
168
W 134 166 202 220 JOB #: 240601 LICENSE #087679
555
ne 199 200
52 WALKWAY 168 321
10'' CMP o 51 167 196 198
164
PROPOSED (4) CULTEC
t
Drive
552 133 193 60 316 315
Inv=137.28 S 100
1
222
17
330XLHD RECHARGER
194 215
0
314
C N N
322 INFILTRATORS
554 99 186
54 103 102 101 171 192 323
lt
53 1 50
7 0 129 132104 98 313
Aspha
172 195 189 191 223
187 312 ROOF LEADER DISCHARGE
128 190 224
553 173 PIPE 4" PVC SDR35
156
94 226 231
131 93 188 242
DECK INV OUT 160.0
N N N
N 35° 42' 00" W
49 105 97 174 244
243.86' (D vey)
41 42 96 183 230
eed)
47180 55 181 243 240 INTO CULTECS 154.5
95 184
ur
158
40 109 245 PROPOSED 4-BEDROOM225 NAL N N N C N L N
243.23' (S
110 PROPOSED 92LOT 2 229
48 56 43 182 PROPOSED 241RESIDENCE 227 228
PROPOSED LOT LINES 126 106 107 80,891 SF (914) 736-3664
GARAGE 162.0
160
ASPHALT 233
185
170
(TYP.) 91 180 DRIVEWAY 1ST FL 163.5
57 127 160
111 PROPOSED ACCESS & UTILITY 246 239 234 232
58 59 44 45 108 BASEMENT 153.5
311
90
EASEMENT FOR THE BENEFIT 0 256 161.8+ 238 FOOTING DRAIN
89 OF LOT 3 OVER LOT 2 176178 1 179
46 7 235 300
199.48'
125 255 160 248 247 298 163.0+ DISCHARGE PIPE 39 Arlo Lane
249 4" PVC SDR35
EXISTING PROPERTY LINE TO 60 120 122
124
175 168 WALKWAY 301 309 310 307306 INV. 151.0 Cortlandt Manor, New York 10567
BE REMOVED. TAX LOTS 6 AND 61 112 88 257 299
121 177166 250 237
11 TO MERGE. LINE TO COVERT 130
108.96'
39 62 115 87 6 4
Stone Wall
TO 50' RIGHT OF WAY LINE 38 1 ' 254
0 123 86 1326.96 295 294 236 308
14 118 1 6 258 293 302
e
116 114 253 251 259 305 TREE REMOVAL OVERLAY
37 117 292
Driv
113 160 150
13 158 252 260 270 303
15
0
Frame 70 71 82 297 269 304
70.54'
12 N 50° 37' 00" E 66
alt
W
119 16 ' 45
" 85 84 290 287
Shed 65 296 291
40" E
2
N 36° 57' 00" W
41.26' 0 5
sph
6° 289
1 67 68 69 26 S3 81 288
6 14 36 72 83 267
284
SUBDIVISION &
A
5 11 19 30 140 283
S 28° 14'
64 S 34° 17' 00" 25 150 266 282
2 7
15
10 0 9 15 63 21
22
23
25.39'
24 E
27 28 35
59.05' 72.32' 79
80 261 268 271 275 286 SITE DEVELOPMENT PLAN
3 8 29 34Stone 74 75
16 Wall
17 Stone 18 20153.35' N 55° 43' 00" E Wall 127.92' 73 N 56° 26' 00" E
Guy
Wire 262 263 264 265
182.80' 272
273 274 276 285
281
FOR
N 53° 26' 00" E
N 31° 21' 00" E
4
32 31 33 76 78
N 60° 15' 00
"E
280 77 MONTROSE STATION, LLC
91.39'
Drain Inlet 77 277 279
36.37' N 42° 45' 00" E
lt N 53° 38' 00" E
Rim=145.17
Stone Wall
5 0 a
h Stone
Asp Masonry
23.03' 1 60.82'
N 37° 28' 00" E
a ll f
MONTROSE STATION ROAD
UPo278le
W e o Pier Edge of Asphalt
33.36'
g Ed
Typ. LOCATION:
ne Edge of Asphalt
S to
Stone UPole WATER 77 MONTROSE STATION ROAD
lt
pha
Retaining Wall Typ. VALVE TYP
A s APPROXIMATE LOCATION OF TOWN OF CORTLANDT, NEW YORK
e of HYDRANT EXISTING WATER METER PIT
Edg
140
FOR 77 MONTROSE STATION
RD (LOT 1)
ENTRANCE SHALL BE
LOCATED AT HIGH POINT SHEET 3 OF 8 TP-2.2
Page 7
WESTCHESTER COUNTY DEPARTMENT OF HEALTH / SOIL DATA CHART )
ed )
' (De rvey
LENGTH OF FIELDS REQUIRED 35 Su
SLOPE
DEEP TEST DESCRIPTION
(LF)
BANK RUN FILL 7. 3'(
LOT OF PERCOLATION
WATER
IMPERVIOUS 67 5.7
N 50
LOT # AREA OWTS RATE
ELEVATION CURTAIN
LAYER REMARKS 68
(IN. BELOW PER EACH
(AC.) AREA TEST HOLE (MIN./IN.) 4 BEDROOM DEPTH VOLUME DRAIN ELEVATION
DEPTH SOIL CLASSIFICATION SURFACE) ADDITIONAL
° 49
(%) NUMBER RESIDENCE (IN) (CY)
BEDROOM
' 50"
Tax Lot 44.17-2-1
D1
D2 0" TO 8"
TOPSOIL NEW OWTS EXISTING HOUSE. N/F Michael Simmon
W
LOT 1 5.64 2%
D3 6" TO 84"
FINE SANDS W/ STONE, MOD. TO 1 TO 5 NONE + 100% N/A N/A N/A N/A N/A SEE WCDH PERMIT
& Jennifer Budner Cortlandt
HIGHLY COMPACTED EXPANSION APPLICATION FOR OWTS
D4
'
.35
TR
A
TOPSOIL
VI
D5 0" TO 8"
84
SITE
S
FINE SANDS W/ STONE, MOD. TO NONE RD
LN
D6 8" TO 84" SOILS TESTING WAS CONDUCTED BY N
Wire Fence
138
HIGHLY COMPACTED CRONIN ENGINEERING AND WITNESSED BY I O
AT
ST
Stone Wall
LOT 2 1.86 2% 1 TO 5 184 LF 125 LF N/A N/A N/A N/A THE WCDH. DEEP TESTING WAS SE
.29'
CONDUCTED ON NOVEMBER 4, 2024 FOR RO
TOPSOIL NT
D7 0" TO 8" THE PRIMARY AND EXPANSION AREAS. M
O
FINE SANDS W/ STONE, MOD. TO NONE
D8 8" TO 96"
HIGHLY COMPACTED
5'
D9 TOPSOIL 34.0
D10
0" TO 8"
FINE SANDS W/ STONE, MOD. TO NONE
Frame
D12
8" TO 84"
HIGHLY COMPACTED
SOILS TESTING WAS CONDUCTED BY Shed
CRONIN ENGINEERING AND WITNESSED BY
e
riv
LOT 3 2.23 10% 1 TO 5 184 LF 125 LF 1 FT 110 N/A N/A THE WCDH. DEEP TESTING WAS
lD
TOPSOIL CONDUCTED ON NOVEMBER 4, 2024 FOR
ve
0" TO 8" THE PRIMARY AND EXPANSION AREAS. OA
KR
D11 FINE SANDS W/ STONE, MOD. TO NONE
ra
D
0'
8" TO 72"
HIGHLY COMPACTED
3.0
G GE HIL
L RD
COLLE
11
1. SOILS TESTING WAS CONDUCTED BY CRONIN ENGINEERING, P.E., P.C. AND WITNESS BY THE WCDH. DEEP TESTING WAS CONDUCTED ON NOVEMBER 8, 2024. PERCOLATION TESTING WAS CONDUCTED ON NOVEMBER 11 & 12, 2024.
2. LOT 1 HAS A RENOVATED SINGLE-FAMILY RESIDENCE AND OWTS. AT THE TIME OF INSPECTION BY CRONIN ENGINEERING P.E. P.C., THE OWTS APPEARED TO BE OPERATING SATISFACTORILY.
e
LOCATION MAP SCALE: 1" = 600'
Lin
g
30 R
RE RD
ZONING DATA CHART - R-80 ( SINGLE FAMILY RESIDENTIAL) on e
YA
'
l riv
A
l yA D
MINIMUM MINIMUM MAXIMUM MINIMUM MINIMUM MINIMUM MAXIMUM MAXIMUM
r al
ne lt
LOT AREA LOT WIDTH HEIGHT FRONT YARD SIDE YARD REAR YARD BUILDING COVERAGE MINIMUM BUILDING FLOOR AREA
LOT DESCRIPTION
e Tax Lot 44.17-1-12
ha
(FT) LANDSCAPE COVERAGE
(SF) (FT) (FT) (FT) (FT) (SF) (SF)
Tax Lot 44.17-1-9 & 10 G
N/F Thomas H. Hintze n es sp
N/F Eugine M. Cesar-Fabian
& Marie Fabian
REQUIRED 80,000 200 2 12 STORIES 50 30 30 65% FAR
70% OF 50% OF FLOOR AREA OF
Irrevocable Trust to A EX
tS
or 35 FT. LOT AREA PRINCIPAL BUILDING IS
RE 5-BD TIN
en SI R G
itt DE M
S
APPROXIMATE NC
N
42,058
rm
EXISTING LOT 44.17-1-6 174 N/A N/A N/A N/A N/A ±92 N/A 62.02'
E
e LOCATION OF
EXISTING LOT 44.17-1-11 381,655 596 <35 583 62 113 1,690 ±95 -
Int UNDERGROUND
PROPANE TANK
'
l
.12
al
88
88
S
W
C
PROPOSED SUBDIVISION LOT 1 245,821 332 <35 170 62 113 <65% FAR ±91 -
'
e EX 19.87'
"W n GA IST
2'
0
to RA ING
.3
PROPOSED SUBDIVISION LOT 2 80,891 267 <35 190 86 32 <65% FAR ±91 - '0 S GE
96
3
°4
20 30'
S
PROPOSED SUBDIVISION LOT 3 97,001 235 <35 99 72 200 <65% FAR ±94 - S
N
SIDE
YARD
'
1 70
375.00'
APPROXIMATE LOCATION e
Stone Wall
m e
OF WATER SERVICE
r a rag
SHUT OFF VALVE F a 40 0 20 40
OWNERS CERTIFICATION G
S
C
50' Wide Right of Way APPROXIMATE LOCATION
Per Deed Liber 2120, Page 12 OF EXISTING 1" TYPE K
THE UNDERSIGNED OWNER, OWNER OF THE PROPERTY HEREON, STATES THAT 50' COPPER WATER SERVICE
HE/SHE IS FAMILIAR WITH THIS MAP, ITS CONTENTS AND ITS LEGENDS AND HEREBY SCALE: 1" = 40 FT.
CONSENTS TO THE FILING OF THIS MAP.
STONE WALLS TYP.
N 36° 13' 00" W
SIGNED THIS _____ DAY OF __________________, 20___.
Tax Lot 44.17-1-9 & 10 OWNER/APPLICANT
N/F Thomas H. Hintze Edge of Drive
e
D
________________________________________________
riv
Irrevocable Trust West 3.00'+/-
AR
PROPOSED OWTS
ON 50'
MARK GIORDANO
tD
TY
PRIMARY AREA
ll
ive 77 MONTROSE STATION, LLC
l
a
ha
r
lt D
FR
TOWN OF CORTLANDT APPROVAL W 1340 BAPTIST CHURCH ROAD
p
ne ha
As
PROPOSED OWTS p YORKTOWN HEIGHTS, NY 10598
t o As
THE DEPARTMENT HEAD SIGNATURES INDICATE THAT THIS DRAWING OR SET OF
S EXPANSION AREA
EXISTING 100% EXPANSION
4' AREA FOR EXISTING HOUSE
DRAWINGS IS CONSISTENT WITH THE PLANNING BOARD RESOLUTION OF APPROVAL AND 2.
5
WITH THE GENERAL REQUIREMENTS AND POLICIES OF THE TOWN OF CORTLANDT FOR 10
Tax Lot 44.17-1-11
37 LF
WHICH THE DEPARTMENT HEAD IS RESPONSIBLE. THE PROJECT DESIGN INCLUDING ALL · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
37 LF
LF
37 LF
PUBLIC HEALTH AND SAFETY CONSIDERATIONS ARE SOLELY THE RESPONSIBILITY OF EXISTING SEPTIC AREA FOR UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
37 LF
THE DESIGN PROFESSIONAL WHO HAS SIGNED AND SEALED THE DRAWINGS. PROPOSED LOT LINES (TYP.) EXISTING HOUSE. SEE WCDH ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
37 LF
37 LF
sphalt Drive 24 FILE No. C2025-12 ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
37 LF
REVIEWED BY THE DEPARTMENT OF ENVIRONMENTAL SERVICES
1. SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
37
S 25° 44' 00" E (Survey) 67
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
37
'
S 26° 00' 00" E (Deed)
37
LF
· COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
LF
97.87' ENGINEERING". ALL RIGHTS RESERVED.
68
__________________________________________________________________________ · AUTHORIZATION No. 130827
.2
DIRECTOR DATE
6'
PROPOSED LOT 1 PROPOSED OWTS
REVISIONS
Remains of A
PRIMARY AREA
RE 0'
YA AR
245,821 SF
REVIEWED BY THE DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT
RD
3
5
__________________________________________________________________________ PROPOSED OWTS 4 REVISE PER WCDH 5-21-26 REVIEW COMMENTS JUNE 17, 2026
DIRECTOR DATE EXPANSION AREA
N 51° 26' 00" E 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
30' 36.28'
REVIEWED BY THE PLANNING BOARD ENGINEER SIDE 2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
N 35° 22' 00" W
PROPOSED SEPTIC TANK
YARD AND PUMP CHAMBER
1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
60.40'
37 L F
__________________________________________________________________________ PROPOSED LOT LINES (TYP.)
37 LF
30 AR
LF
RE ARD
# REASON DATE
37 LF
'
Y
ENGINEER DATE
37 LF
R=293.51' '
37 LF 7'
15 MUNICIPAL TAX IDENTIFICATION:
37 L3F 7'
.
L=112.50' 90
37 L3F 7'
APPROVED BY RESOLUTION No.________ OF THE PLANNING BOARD OF THE TOWN OF
2 SECTION: 44.17
37
Stone Wall
37
CORTLANDT, NEW YORK ON THE ________ DAY OF ________________, 20____ SUBJECT
37
BLOCK:
LF 37'
1
3
TO ALL REQUIREMENTS AND CONDITIONS OF SAID RESOLUTION.
LF 37'
S 31° 51' 50" W (Survey)
ANY CHANGE, ERASURE, MODIFICATION, OR REVISION IN THIS PLAT OR SITE S 31° 35' 50" W (Deed) LOT: 6 & 11
DEVELOPMENT PLAN, AFTER THE ABOVE DATE, SHALL VOID THIS APPROVAL. 126.47' (Survey) PROPOSED LOT 3
DECK 97,001 SF SUBLOT: -----
135.26 (Deed)
SIGNED THIS _______ DAY OF ___________________, 20______ BY
Tax Lot 44.17-1-16 DRAWN BY: AD
osed
d
ri ve PROPOSED 4-BEDROOM
N/F Reid Gearhart CHECKED: KS/PMB
171.00'
0' xp e D RESIDENCE
50.0 ly E at & Tiziana Mohorovic
_________________________________________________________
r tial rrug alt GARAGE 171.0 PROPOSED
PROJECT: 77 MONTROSE STATION RD
CHAIRPERSON OF THE PLANNING BOARD Pa " Co Pip e 1ST FL 172.5
ph
ASPHALT
30' Deed Liber #12229,
336.83'
10 etal s BASEMENT 162.5 DRIVEWAY
SIDE Page #339 DATE: JANUARY 22, 2025 EXPIRATION DATE: 03-31-2027
M ll A PROPOSED SEPTIC TANK
WCDH APPROVAL
REARD
PATRICK M. BELL, P.E.
30' R
YARD
a
YA
AND PUMP CHAMBER
W JOB #: 240601 LICENSE #087679
e WALKWAY
on
EXISTING PUBLIC WATER / PROPOSED SEPARATE SEWAGE TREATMENT SYSTEM 10'' CMP
St
Drive
APPROVED PURSUANT TO CHAPTER 873, ARTICLE X, SECTIONS 873.951 AND 873.1011 Inv=137.28
AND ARTICLES VII AND VIII OF THE WESTCHESTER COUNTY SANITARY CODE SUBJECT
TO THE PROVISION OF PUBLIC WATER SUPPLY AND SEPARATE SEWAGE TREATMENT
C N N
lt
FACILITIES TO SERVE EACH HABITABLE BUILDING HEREAFTER CONSTRUCTED. THESE 30' 30'
Aspha
SIDE SIDE
FACILITIES ARE TO BE INSTALLED IN ACCORDANCE WITH LAND IMPROVEMENT PLANS YARD
YARD
AND SPECIFICATIONS APPROVED BY AND FILED IN THIS OFFICE PRIOR TO THE DECK
N N N
N 35° 42' 00" W
50' Wide Right of Way
CONSTRUCTION OF SUCH BUILDING.
243.86' (D vey)
eed)
Per Deed Liber 2120, Page 12
EACH PURCHASER OF PROPERTY SHOWN HEREON SHALL BE FURNISHED A TRUE COPY
ur
NAL N N N C N L N
OF THIS PLAT SHOWING THIS ENDORSEMENT. ANY ERASURES, CHANGES, ADDITIONS,
243.23' (S
PROPOSED 4-BEDROOM
PROPOSED LOT 2
OR ALTERATIONS OF ANY KIND, EXCEPT THE ADDITION OF SIGNATURES OF ANOTHER PROPOSED RESIDENCE (914) 736-3664
PROPOSED LOT LINES 80,891 SF
APPROVING AUTHORITY AND THE DATE THEREOF MADE ON THIS PLAT AFTER THIS 30' ASPHALT GARAGE 162.0
30' SIDE (TYP.) DRIVEWAY 1ST FL 163.5
APPROVAL, SHALL INVALIDATE THE APPROVAL. PROPOSED ACCESS & UTILITY
SIDE YARD BASEMENT 153.5
YARD Tax Lot 44.17-1-6 EASEMENT FOR THE BENEFIT
72' 39 Arlo Lane
199.48'
OF LOT 3 OVER LOT 2
__________________________________________________________________________ Tax Lot 44.17-2-3
APPROVED BY THE ASSISTANT COMMISSIONER OF HEALTH DATE N/F Anne Sumers EXISTING PROPERTY LINE TO WALKWAY Cortlandt Manor, New York 10567
BE REMOVED. TAX LOTS 6 AND
ON BEHALF OF THE DEPARTMENT OF HEALTH 11 TO MERGE. LINE TO COVERT
108.96'
Deed Control # PROPOSED 1"
Stone Wall
TO 50' RIGHT OF WAY LINE TYPE K COPPER '
442250322 .96
190'
136
WATER SERVICE PRELIMINARY SUBDIVISION PLAT
rive lt D
Frame
70.54'
N 50° 37' 00" E W
45"
pha
99'
Shed 52'
40" E
N 36° 57' 00" W
41.26'
6°
FRONT
S3
SUBDIVISION &
YARD
50'
As
S 28° 14'
PROPOSED 1"
SITE DEVELOPMENT PLAN
FRONT
S 34° 17' 00" E
YARD
TYPE K COPPER
50'
25.39' 59.05'
FOR
72.32' WATER SERVICE
Stone Wall 153.35' Stone Wall 127.92' Guy
N 55° 43' 00" E N 56° 26' 00" E Wire
77 MONTROSE STATION, LLC
FRO RD
182.80'
50' T
N
N 31° 21' 00" E
Properties Not Contiguous
A
N 60° 15' 00
Y
N 53° 26' 00" E 91.39' "E
Drain Inlet - Overlap Exists
N 42° 45' 00" E
t Stone Wall
hal Stone
36.37' N 53° 38' 00" E
Rim=145.17
23.03'
ll Asp 60.82'
MONTROSE STATION ROAD
Wa
Masonry
of UPole
N 37° 28' 00" E
33.36'
e Ed ge Pier Edge of Asphalt Typ. LOCATION:
Stone S ton t
UPole WATER Edge of Asphalt 77 MONTROSE STATION ROAD
Retaining Wall sp hal Typ. VALVE TYP PROPOSED WATER
TOWN OF CORTLANDT, NEW YORK
of A
APPROXIMATE LOCATION OF SHUTOFF VALVE & PROPOSED WATER
HYDRANT APPROX. LOCATION OF EXISTING 16"Ø CAST IRON
e EXISTING WATER METER PIT WATER METER PIT
Edg
SHUTOFF VALVE & WATER MAIN (NWJWW TRANSMISSION MAIN)
SP-3.1
FOR 77 MONTROSE STATION WATER METER PIT MONTROSE IMPROVEMENT DISTRICT SERVICE
RD (LOT 1)
ENTRANCE SHALL BE
LOCATED AT HIGH POINT AREA
SHEET 4 OF 8
Page 8
WESTCHESTER COUNTY DEPARTMENT OF HEALTH / SOIL DATA CHART PIPE CHART IMPERVIOUS AREA )
ed )
PROPOSED IMPERVIOUS ' ( De rvey
LENGTH OF FIELDS REQUIRED PIPE LOCATION TYPE EXISTING IMPERVIOUS (LOT1) 35 Su
SLOPE
DEEP TEST DESCRIPTION
(LF)
BANK RUN FILL
4"Ø SOLID PVC SDR35 (LOT 2 + LOT 3) 7. 3'(
LOT OF PERCOLATION
WATER
IMPERVIOUS ROOF LEADERS 67 5.7
DRIVEWAY 20,520 SF. 8,360 SF
N 50
LOT # AREA OWTS RATE
ELEVATION CURTAIN
LAYER REMARKS
@ 1% MIN SLOPE 68
(IN. BELOW PER EACH DRAIN
(AC.) AREA TEST HOLE (MIN./IN.) 4 BEDROOM DEPTH VOLUME ELEVATION
DEPTH SOIL CLASSIFICATION SURFACE) ADDITIONAL FOOTING DRAINS 4"Ø PERFORATED HDPE FRAME SHED 295 SF 0
° 49
(%) NUMBER RESIDENCE (IN) (CY)
BEDROOM
4"Ø SOLID HDPE DETACHED GARAGE 671 SF 0
' 50"
FOOTING DRAIN DISCHARGE Tax Lot 44.17-2-1
EXISTING HOUSE. @ 1% MIN SLOPE
SEE WCDH PERMIT
HOUSE AND GARAGE 1,797 SF 5,600 SF N/F Michael Simmon
W
LOT 1 5.64 2% N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
APPLICATION FOR OWTS & Jennifer Budner Cortlandt
WATER SERVICE 1"Ø TYPE "K" COPPER PATIO 720 SF 384 SF
(WCDH FILE#C2025-12)
WALKWAY 0 668 SF
'
.35
TR
WATER METER NEPTUNE T-10 WATER METER
A
D5 TOPSOIL
VI
0" TO 8" SOILS TESTING WAS CONDUCTED BY
84
TOTAL 24,003 SF 15,012
SITE
S
D6 FINE SANDS W/ STONE, MOD. TO NONE RD
LN
8" TO 84" CRONIN ENGINEERING AND WITNESSED BY BY UTILITY COMPANY, TO BE N
Wire Fence
138
D9 HIGHLY COMPACTED
THE WCDH. DEEP TESTING WAS UTILITIES AT
I O
UNDERGROUND ST
Stone Wall
LOT 2 1.86 2% 1 TO 5 184 LF 45 LF N/A N/A N/A N/A CONDUCTED ON NOVEMBER 4, 2024 FOR SE
.29'
THE PRIMARY AND EXPANSION AREAS. RAW SEWER LINE 4"Ø SOLID PVC SDR35 RO
TOPSOIL NT
D7 0" TO 8" PUMPING TO THE OWTS AREA IS REQUIRED TO SEPTIC SYSTEM @ 2% MIN SLOPE M
O
FINE SANDS W/ STONE, MOD. TO NONE
D8 8" TO 96" FOR LOT 2.
HIGHLY COMPACTED
SOIL DATA NOTES 34.0
5'
D10 0" TO 8"
TOPSOIL
SOILS TESTING WAS CONDUCTED BY Frame
FINE SANDS W/ STONE, MOD. TO NONE
D12 8" TO 84" CRONIN ENGINEERING AND WITNESSED BY Shed
HIGHLY COMPACTED
THE WCDH. DEEP TESTING WAS 1. SOILS TESTING WAS CONDUCTED BY CRONIN ENGINEERING, AND WITNESS BY THE WCDH. DEEP
e
LOT 3 2.23 10% 1 TO 5 184 LF 45 LF 1 FT 110 N/A N/A CONDUCTED ON NOVEMBER 4, 2024 FOR TESTING WAS CONDUCTED ON NOVEMBER 4, 2024. PERCOLATION TESTING WAS CONDUCTED ON
riv
TOPSOIL
THE PRIMARY AND EXPANSION AREAS. NOVEMBER 6 AND 7, 2024. lD
ve
OA
0" TO 8" PUMPING TO THE OWTS AREA IS REQUIRED 2. LOT 1 HAS A RENOVATED SINGLE-FAMILY RESIDENCE AND OWTS. AT THE TIME OF INSPECTION BY KR
D11 FINE SANDS W/ STONE, MOD. TO NONE
ra
D
' 0
8" TO 72" FOR LOT 3. CRONIN ENGINEERING, THE OWTS APPEARED TO BE OPERATING SATISFACTORILY.
3.0
HIGHLY COMPACTED
3. THE HOUSE PRE-DATES ZONING AND THERE IS NO FILE ON RECORD SHOWING NUMBER OF BEDROOMS. G GE HIL
L RD
COLLE
11
ZONING DATA CHART - R-80 ( SINGLE FAMILY RESIDENTIAL)
e
LOCATION MAP SCALE: 1" = 600'
PROPOSED DISTURBANCE Lin
MINIMUM MINIMUM MAXIMUM MINIMUM MINIMUM MINIMUM MAXIMUM MAXIMUM
REAR YARD MINIMUM
LOT DESCRIPTION LOT AREA LOT WIDTH HEIGHT FRONT YARD SIDE YARD BUILDING COVERAGE BUILDING FLOOR AREA
LANDSCAPE COVERAGE g e
lon
(SF) (FT) (FT) (FT) (FT) (FT) (SF) (SF)
PROPOSED DISTURBANCE 77,100 SF
y A riv
1
2 2 STORIES 70% OF 50% OF FLOOR AREA OF ll D
REQUIRED 80,000 200
or 35 FT.
50 30 30 65% FAR
LOT AREA PRINCIPAL BUILDING PROP. WETLAND DISTURBANCE 0 SF
e ra
PROPOSED WETLAND BUFFER e n lt Tax Lot 44.17-1-12
0 SF Tax Lot 44.17-1-9 & 10 G ha
es
DISTURBANCE N/F Eugine M. Cesar-Fabian
sp
EXISTING LOT 44.17-1-6 42,058 174 N/A N/A N/A N/A N/A ±92 N/A
N/F Thomas H. Hintze n & Marie Fabian
Irrevocable Trust to A EX
tS
IS
RE 5-BD TIN
en
EXISTING LOT 44.17-1-11 381,655 596 <35 583 62 113 1,690 ±95 -
SI R G
itt APPROXIMATE
DE M
NC
rm E
62.02'
245,821 e LOCATION OF
Int
PROPOSED SUBDIVISION LOT 1 332 <35 170 62 113 <65% FAR ±91 -
UNDERGROUND
PROPANE TANK
'
PROPOSED SUBDIVISION LOT 2 80,891 267 <35 190 86 32 <65% FAR ±91 -
l
.12
al
88
88
W
'
ne
PROPOSED SUBDIVISION LOT 3 97,001 235 <35 99 72 200 <65% FAR ±94 - EX 19.87'
W GA IST
'
0"
to
.32
RA ING
'0 S GE
96
3
°4
TOWN OF CORTLANDT SITE PLAN NOTES S
20
375.00'
1. AS PART OF THE BUILDING PERMIT PROCESS FOR THE INITIAL DEVELOPMENT OF ALL SINGLE FAMILY LOTS AN INDIVIDUAL SITE APPROXIMATE LOCATION e
Stone Wall
DEVELOPMENT PLAN SHALL BE SUBMITTED TO DIVISION OF CODE ADMINISTRATION AND ENFORCEMENT FOR APPROVAL BY THE m e
OF WATER SERVICE
r a rag 351
DIRECTOR OF TECHNICAL SERVICES IN COMPLIANCE WITH ALL LOCAL ORDINANCES, INCLUDING AMONG OTHERS, THE TOWN'S SHUT OFF VALVE F a 40 0 20 40
WETLAND ORDINANCE AND STEEP SLOPE ORDINANCE AND INCLUDING SOIL EROSION AND DUST CONTROLS AND STORMWATER G
DRAINAGE FACILITIES DURING CONSTRUCTION. PURSUANT TO CHAPTER 283 (TREES) OF THE TOWN OF CORTLANDT CODE, TREES 50' Wide Right of Way APPROXIMATE LOCATION
SHALL BE LOCATED AND IDENTIFIED ON A TREE INVENTORY AND TREE PROTECTION PLAN PREPARED BY AN ISA CERTIFIED Per Deed Liber 2120, Page 12 OF EXISTING 1" TYPE K
352
ARBORIST AS TO SIZE AND SPECIES. TREES TO BE CUT AND TREES TO BE SAVED SHOULD BE IDENTIFIED. THE LOCATION AND SIZE 50' COPPER WATER SERVICE 353
OF LOADING AREAS FOR THE REMOVAL OF CUT TREES SHOULD BE SHOWN ON THE PLAN FOR TREE DISPOSITION AND CLEAN UP SCALE: 1" = 40 FT.
DESCRIBED. NO BUILDING PERMIT SHALL BE ISSUED FOR ANY LOTS SHOWN HEREON UNTIL THE DIRECTOR OF TECHNICAL SERVICES
APPROVES THE SITE DEVELOPMENT PLAN FOR SAME, AND NO CERTIFICATE OF OCCUPANCY SHALL BE ISSUED FOR ANY LOTS UNTIL 356DT1 354
STONE WALLS TYP. 357
N 36° 13' 00" W
AN "AS BUILT" SURVEY HAS BEEN SUBMITTED TO AND APPROVED BY THE DIRECTOR OF TECHNICAL SERVICES. THE "AS BUILT"
SURVEY SHALL SHOW COMPLETE INFORMATION INCLUDING FINAL CONTOURS, FLOOR LEVELS, AND ALL PERTINENT FEATURES. Tax Lot 44.17-1-9 & 10 358 OWNER/APPLICANT
N/F Thomas H. Hintze Edge of Drive
e
355
riv
WCDH NOTES Irrevocable Trust West 3.00'+/- PROPOSED OWTS
tD
PRIMARY AREA DT2 359
ll
ive 77 MONTROSE STATION, LLC
458
al
1. THERE ARE NO EXISTING OR PROPOSED WELLS LOCATED WITHIN 200 FEET AT A LOWER ELEVATION AND IN A DIRECT LINE WITH THE a r 442 457
ph
lt D
GROUNDWATER FLOW OR WITHIN 100 FEET IN ANY DIRECTION TO THE PROPOSED OWTS AREA UNLESS OTHERWISE SHOWN HEREON. W 441 DT3 363 360 1340 BAPTIST CHURCH ROAD
455
ne ha 362
As
2. ALL COMPONENTS OF THE OWTS AND CONSTRUCTION TECHNIQUES OF SAME ARE TO BE IN ACCORDANCE WITH THE LATEST
PROPOSED OWTS p YORKTOWN HEIGHTS, NY 10598
WESTCHESTER COUNTY DEPARTMENT OF HEALTH "RULES AND REGULATIONS FOR THE DESIGN AND CONSTRUCTION OF
t o As 443 456 361
RESIDENTIAL SUBSURFACE TREATMENT SYSTEMS AND DRILLED WELLS IN WESTCHESTER COUNTY, NY" AND ANY OTHER RULES AND S EXPANSION AREA 452
EXISTING 100% EXPANSION
REGULATIONS THAT MAY APPLY.
4' 454 367
3. THE OWTS AREAS MUST BE ISOLATED AND EFFECTIVELY PROTECTED AGAINST DAMAGE BY EROSION, 439 2 .5 365 AREA FOR EXISTING HOUSE
STORAGE OF EARTH OR MATERIALS OR COMPACTION BY MACHINES AND HEAVY EQUIPMENT. DAMAGE TO ANY PORTION OF AN OWTS 0 DT7 453 DT4
438 1440 451
Tax Lot 44.17-1-11 370
37 LF
AREA SHALL BE REPAIRED BEFORE APPROVAL IS GRANTED. 364 368
0
437
37 LF
366
LF
16
4. EXPANSION AREAS FOR ALL LOTS SHALL REMAIN UNDISTURBED AS MUCH AS IS PRACTICABLE. 450 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
372
37 LF
5. THE EXISTING ON-SITE WASTEWATER TREATMENT SYSTEM FOR LOT 1 WAS INSPECTED BY THIS OFFICE AND APPEARED TO BE EXISTING SEPTIC AREA FOR
369 UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
37 LF
DT5 373
OPERATING SATISFACTORILY AT THE TIME OF INSPECTION. NO IMPROVEMENTS OR CHANGES PROPOSED. 422 PROPOSED LOT LINES (TYP.) EXISTING HOUSE. SEE WCDH
37 LF
449 374 375 FILE No. C2025-12
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
37 LF
6. THE PROPERTY IS SUBJECT TO LOCAL WETLAND REGULATIONS, IF ANY. halt Drive 24
0
423 ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
37 LF
16
448
1. 377 371
37
NOTES SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
S 25° 44' 00" E (Survey) DT9 DT8 67
459
37
S 26° 00' 00" E (Deed) 420 421 426
'
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
37
379
LF
1. THE APPLICANT IS AWARE THAT THE DISTURBED AREAS SHALL BE 100% STABILIZED AND PLANTED PRIOR TO THE ISSUANCE OF A 424 425 376 398 · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED.
LF
97.87' 378 396
68
CERTIFICATE OF OCCUPANCY 490 489 486 427 461 · AUTHORIZATION No. 130827
487 460 DT6
.2
2. THE APPLICANT SHALL SUBMIT AN AS-BUILT FOUNDATION SURVEY TO THE TOWN OF CORTLANDT PRIOR TO FRAMING. 469 395 397
sp
6'
3. THE APPLICANT SHALL SUBMIT AN AS-BUILT CENTERLINE DRIVEWAY PROFILE WITH SLOPES/GRADES TO THE TOWN OF CORTLANDT PROPOSED OWTS 485 409
PROPOSED LOT 1 491 488 428 470 462 380
REVISIONS
Remains of A
PRIOR TO PAVING. 245,821 SF PRIMARY AREA 468 410 399
4. PRIOR TO THE BACKFILLING OF ANY STORMWATER BEST MANAGEMENT PRACTICES, DOTS-ENGINEERING SHALL BE NOTIFIED TO 541 463 381 382
PERFORM AN INSPECTION. 543 542 540 539 538 429 464 394
492 484 466 407 400 5
5. ALL PROPOSED IMPORT FILL MUST BE TESTED AND CERTIFIED AS UNRESTRICTED, SUITABLE FOR RESIDENTIAL USE IN ACCORDANCE 493 544 476 412 408 383
WITH TOWN POLICY. CERTIFICATION MUST BE PROVIDED BY A LICENSED PROFESSIONAL. ALL CERTIFICATIONS SHALL BE ADDRESSED PROPOSED OWTS 471 392 401
551 0 465 405 390 4 REVISE PER WCDH 5-21-26 REVIEW COMMENTS JUNE 17, 2026
TO TOWN'S PLANNING BOARD ENGINEER. ALL SOIL ANALYTICS AND REPORTS WILL BE FORWARDED TO THE TOWN'S PLANNING BOARD EXPANSION AREA
546 545 18
ENGINEER FOR REVIEW AND APPROVAL. 550 483 411 N 51° 26' 00" E 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
472 467 404 403 393
6. PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY (C.O.), THE TOWN WILL REQUIRE A CERTIFICATION FROM A NYS 481 384 36.28'
ENGINEER THAT THE COMPLETED SITE WORK AND DRAINAGE IMPROVEMENTS WILL NOT CAUSE AN ADVERSE IMPACT TO ADJOINING 495 549 406 388 NOVEMBER 20, 2025
548 547 478 2 LABELLA COMMENTS DATED 10-07-2025
N 35° 22' 00" W
PROPOSED SEPTIC TANK
OR DOWNSTREAM PROPERTIES.
AND PUMP CHAMBER DT10 385 389391
7. DOUBLE CHECK VALVE SHALL BE INSTALLED IN ACCORDANCE WITH UNIVERSITY OF SOUTHERN CALIFORNIA LIST OF APPROVED 480 473474 419 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
60.40'
494 413 349
37 LF
BACKFLOW PREVENTION DEVICES, NYSDOH GUIDELINES FOR DESIGNING BACKFLOW PREVENTION ASSEMBLY INSTALLATIONS, AND ROOF LEADER DISCHARGE 417
PROPOSED LOT LINES (TYP.)
386 387
37 LF
LF
BUILDING CODE. PIPE 4" PVC SDR 35 565 496 477 # REASON DATE
37 LF
8. ROCK RIPPING WILL BE USED WHEREVER POSSIBLE. IF BLASTING IS REQUIRED, IT WILL REQUIRE PRIOR APPROVAL FROM THE TOWN 479 350
418
37 LF
R=293.51'
INV OUT 165.0 ' 497 157 415 348
37 LF
OF CORTLANDT AND AN AIR QUALITY PERMIT FROM THE WESTCHESTER COUNTY DEPARTMENT OF HEALTH. INTO CULTECS 160.5 15 MUNICIPAL TAX IDENTIFICATION:
156 347
37 LF
9. THERE SHALL BE NO PROCESSING OF EXCAVATED MATERIALS BY A ROCK CRUSHER OR SIMILAR EQUIPMENT ON SITE. 0. DT11 416
L=112.50' 566 498 209
37 LF
9 DT12
10. AN APPLICATION FOR A ROAD OPENING PERMIT SHALL BE SUBMITTED TO THE DEPARTMENT OF ENVIRONMENTAL SERVICES (DOES). PROPOSED (4) CULTEC 2 333 SECTION: 44.17
37
Stone Wall
332 346
37
11. PROVIDE 10-FOOT SEPARATION BETWEEN WATER AND OTHER SERVICES. 330XLHD RECHARGER
15 562 414
37
BLOCK:
LF
12. ROOF AND FOOTING DRAINS SHALL BE 2 SEPARATE PIPES. ROOF LEADERS SHALL BE DIRECTED TO PROPOSED STORMWATER BEST 0
INFILTRATORS 158 155 0 1
154 210 17 344
LF
MANAGEMENT PRACTICES. FOOTINGS SHALL DAYLIGHT TO ENERGY DISSIPATORS (LEVEL SPREADERS) AWAY FROM STEEP SLOPES. S 31° 51' 50" W (Survey) 338
17 208 337
S 31° 35' 50" W (Deed) 0 345 LOT: 6 & 11
343 341
STEEP SLOPE NOTES 126.47' (Survey) FOOTING DRAIN DISCHARGE
PIPE 4" PVC SDR35
561
DECK
160
207 475
PROPOSED LOT 3
97,001 SF 331 SUBLOT: -----
135.26 (Deed) INV. 160.0 560 152 206 402
DISTURBANCE OR ALTERATION OF AREAS WITH STEEP SLOPES SHALL ADDITIONALLY BE IN CONFORMANCE WITH THE
336 339 342 DRAWN BY: AD
153 Tax Lot 44.17-1-16
212 213
FOLLOWING PROVISIONS: 327
osed
d
ri ve 558
PROPOSED 4-BEDROOM
+170.8 161 204 203 334
330 328 N/F Reid Gearhart CHECKED: KS/PMB
171.00'
0' p RESIDENCE
tD
1. THE PLANNING, DESIGN AND DEVELOPMENT OF BUILDINGS SHALL PROVIDE THE MAXIMUM IN STRUCTURAL SAFETY, x e 163 & Tiziana Mohorovic
50.0 ly E at 205 340
ial rrug al
SLOPE STABILITY AND HUMAN ENJOYMENT WHILE ADAPTING THE AFFECTED SITE TO, AND TAKING ADVANTAGE OF, GARAGE 171.0 PROPOSED
r t 329 326 PROJECT: 77 MONTROSE STATION RD
THE BEST USE OF THE NATURAL TERRAIN AND AESTHETIC CHARACTER.
Pa " Co Pip e h 557 1ST FL 172.5 ASPHALT
169 162 164
p 335 320 Deed Liber #12229,
336.83'
2. THE TERRACING OF BUILDING SITES, INCLUDING THE MOUNDING OF SEPTIC TILE FIELDS, SHALL BE KEPT TO AN
10 etal s 556 BASEMENT 162.5 DRIVEWAY 201 211 325
197 217 319 Page #339 DATE: JANUARY 22, 2025 EXPIRATION DATE: 03-31-2027
ABSOLUTE MINIMUM.
M ll A 165
PROPOSED SEPTIC TANK
PATRICK M. BELL, P.E.
3. ROADS AND DRIVEWAYS SHALL FOLLOW THE NATURAL TOPOGRAPHY TO THE GREATEST EXTENT POSSIBLE IN a 172.0+ 216
AND PUMP CHAMBER
214 324 317 318
168
ORDER TO MINIMIZE THE POTENTIAL FOR EROSION AND SHALL BE CONSISTENT WITH ALL OTHER APPLICABLE W 166 202 JOB #: 240601 LICENSE #087679
e 555 WALKWAY 168 200
ORDINANCES AND REGULATIONS OF THE TOWN OF CORTLANDT AND CURRENT ENGINEERING PRACTICES. 321
10'' CMP on 167
164
4. REPLANTING SHALL CONSIST OF INDIGENOUS VEGETATION AND SHALL REPLICATE THE ORIGINAL VEGETATION ON PROPOSED (4) CULTEC
St
e
552 160 316 315
Inv=137.28
lt Driv
THE SITE AS MUCH AS POSSIBLE.
17
330XLHD RECHARGER
C N N
0
5. THE NATURAL ELEVATIONS AND VEGETATIVE COVER OF RIDGELINES SHALL BE DISTURBED ONLY IF THE CREST OF 322 314 INFILTRATORS
A RIDGE AND THE TREE LINE AT THE RIDGE REMAIN UNINTERRUPTED. THIS MAY BE ACCOMPLISHED EITHER BY
171 186
POSITIONING BUILDINGS AND AREAS OF DISTURBANCE BELOW A RIDGELINE OR BY POSITIONING BUILDINGS AND 170
313
Aspha
AREAS OF DISTURBANCE AT A RIDGELINE SO THAT THE ELEVATION OF THE ROOFLINE OF THE BUILDING IS NO 172 ROOF LEADER DISCHARGE
GREATER THAN THE ELEVATION OF THE NATURAL TREE LINE. HOWEVER, UNDER NO CIRCUMSTANCES SHALL MORE 312
PIPE 4" PVC SDR35
156
THAN 100 FEET ALONG THE RIDGELINE, TO A WIDTH OF 100 FEET GENERALLY CENTERED ON THE RIDGELINE, BE 94
93 DECK 231 INV OUT 160.0 N N N
N 35° 42' 00" W
DISTURBED. 50' Wide Right of Way
243.86' (D vey)
96 230
eed)
6. ANY REGRADING SHALL BLEND IN WITH THE NATURAL CONTOURS AND UNDULATIONS OF THE LAND. Per Deed Liber 2120, Page 12 180 INTO CULTECS 154.5
95
ur
NAL N N N C N L N
158
7. CUTS AND FILLS SHALL BE ROUNDED OFF TO ELIMINATE SHARP ANGLES AT THE TOP, BOTTOM AND SIDES OF
243.23' (S
REGRADED SLOPES. VISIBLE CONSTRUCTION CUTS AND PERMANENT SCARRING SHOULD BE MINIMIZED. PROPOSED 4-BEDROOM 229
PROPOSED 92LOT 2
8. THE ANGLE OF CUT AND FILL SLOPES SHALL NOT EXCEED A SLOPE OF ONE VERTICAL TO TWO HORIZONTAL 80,891 SF PROPOSED RESIDENCE 227 228 (914) 736-3664
PROPOSED LOT LINES GARAGE 162.0
160
EXCEPT WHERE RETAINING WALLS, STRUCTURAL STABILIZATION OR OTHER METHODS ACCEPTABLE TO THE ASPHALT 233
185
170
DIRECTOR OF TECHNICAL SERVICES ARE USED. (TYP.) 91 DRIVEWAY 1ST FL 163.5
160 PROPOSED ACCESS & UTILITY 234 232
9. TOPS AND BOTTOMS OF CUT AND FILL SLOPES SHALL BE SET BACK FROM STRUCTURES A DISTANCE THAT WILL 58 59 BASEMENT 153.5
ENSURE THE SAFETY OF THE STRUCTURE IN THE EVENT OF THE COLLAPSE OF THE CUT OR FILL SLOPES. Tax Lot 44.17-1-6 90
EASEMENT FOR THE BENEFIT
17
0 161.8+ 311 FOOTING DRAIN
39 Arlo Lane
199.48'
GENERALLY, SUCH DISTANCE SHALL BE CONSIDERED TO BE SIX FEET PLUS 1/2 THE HEIGHT OF THE CUT OR FILL. 89 OF LOT 3 OVER LOT 2 163.0+ DISCHARGE PIPE
NEVERTHELESS, A STRUCTURE BUILT ON A SLOPE OR AT THE TOE OF A SLOPE IS PERMITTED IF IT IS PROPERLY Tax Lot 44.17-2-3 160 4" PVC SDR35
EXISTING PROPERTY LINE TO 120 168 WALKWAY 310 307 Cortlandt Manor, New York 10567
DESIGNED TO RETAIN THE SLOPE AND WITHSTAND THE FORCES EXERTED ON IT BY THE RETAINED SLOPE. N/F Anne Sumers 60 309 306 INV. 151.0
10. DISTURBANCE OF ROCK OUTCROPS SHALL BE BY MEANS OF EXPLOSIVE ONLY IF LABOR AND MACHINES ARE NOT BE REMOVED. TAX LOTS 6 AND 61 121 166
EFFECTIVE AND ONLY IF ROCK BLASTING IS CONDUCTED IN ACCORDANCE WITH ALL APPLICABLE LAWS AND 11 TO MERGE. LINE TO COVERT 1" 130
108.96'
Deed Control # PROPOSED
REGULATIONS OF THE TOWN OF CORTLANDT, COUNTY OF WESTCHESTER, AND THE STATE OF NEW YORK. 3962 K COPPER 646'
Stone Wall
TO 50' RIGHT OF WAY LINE 38 TYPE 19
11. DISTURBANCE OF STEEP SLOPES SHALL BE UNDERTAKEN IN WORKABLE UNITS IN WHICH THE DISTURBANCE CAN 442250322 14
0 36 . 295 294 308
WATER SERVICE 118 1162 293 UTILITY + GRADING PLAN / INTEGRATED PLOT PLAN
e
BE COMPLETED AND STABILIZED IN ONE CONSTRUCTION SEASON SO THAT AREAS ARE NOT LEFT BARE AND 116 305
37 117 292
Driv
EXPOSED DURING THE WINTER AND SPRING THAW PERIODS (DECEMBER 15 THROUGH APRIL 15). AREA OF CROSS HATCH 160 150
12. DISTURBANCE OF EXISTING VEGETATIVE GROUND COVER SHALL NOT TAKE PLACE MORE THAN 15 DAYS PRIOR TO 13 158 260 270 303
0 INDICATES LIMITS OF COMMON 269
15 Frame 12 70 2 & 3 297 304
70.54'
66
t
GRADING AND CONSTRUCTION. N 50° 37' 00" EDRIVEWAY "W
l
119
BETWEEN LOTS 290
a
13. TEMPORARY SOIL STABILIZATION, INCLUDING, IF APPROPRIATE, TEMPORARY STABILIZATION MEASURES SUCH AS Shed 65 16 ' 45 296 287
291
40" E
EXISTING DRIVEWAY 2
N 36° 57' 00" W
41.26' 0 6° 5
h
NETTING OR MULCHING TO SECURE SOIL DURING THE GROW-IN PERIOD, MUST BE APPLIED TO AN AREA OF 67 S3 289
69
SUBDIVISION &
Asp
DISTURBANCE WITHIN TWO DAYS OF ESTABLISHING THE FINAL GRADE, AND PERMANENT STABILIZATION MUST BE SITE DISTANCE 1 6 14 68 288 284
11 267 140 283
5 19
S 28° 14'
APPLIED WITHIN 15 DAYS OF ESTABLISHING THE FINAL GRADE. 64 PROPOSED 1"
14. SOIL STABILIZATION MUST BE APPLIED WITHIN TWO DAYS OF DISTURBANCE IF THE FINAL GRADE IS NOT EXPECTED
TO BE ESTABLISHED WITHIN 60 DAYS. SD LL = 246' 2 7
15
100 9 15 63
S 34° 17' 00" E
21 23
25.39'
150
59.05'
80 261 TYPE K COPPER
266
268 271 275 286 282 PROPOSED HIDDEN SITE DEVELOPMENT PLAN
22
FOR
72.32' WATER SERVICE DRIVEWAYS SIGN
SD LR = 195' 3 8 16 Wall Guy
15. MEASURES FOR THE CONTROL OF EROSION AND SEDIMENTATION SHALL BE UNDERTAKEN CONSISTENT WITH THE 17 Stone 18 20153.35' N 55° 43' 00" E Stone Wall 127.92' 262 263 264 273 274 276 285
WESTCHESTER COUNTY SOIL AND WATER CONSERVATION DISTRICT'S BEST MANAGEMENT PRACTICES MANUAL N 56° 26' 00" E Wire 265 272 281
FOR EROSION AND SEDIMENT CONTROL AND NEW YORK STATE GUIDELINES FOR URBAN EROSION AND SEDIMENT
CONTROL, AS AMENDED, OR THEIR EQUIVALENTS SATISFACTORY TO THE APPROVAL AUTHORITY.
N 31° 21' 00" E
4
182.80'
N 60° 15' 00 280 Properties Not Contiguous
77 MONTROSE STATION, LLC
N 53° 26' 00" E 91.39' 76 77 78 "E
277 - Overlap Exists
16. ALL PROPOSED DISTURBANCE OF STEEP SLOPES SHALL BE UNDERTAKEN WITH CONSIDERATION OF THE SOILS
N 42° 45' 00" E Drain Inlet SIGHT DISTAN
Stone Wall 279
t CE >350 FT
hal Stone
36.37' N 53° 38' 00" E
LIMITATIONS CHARACTERISTICS CONTAINED IN THE IDENTIFICATION LEGEND, WESTCHESTER COUNTY SOILS
PROPOSED HIDDEN 0 Rim=145.17 ISTANC
E ±260'
15
SURVEY, 1989, AS PREPARED BY THE WESTCHESTER COUNTY SOIL AND WATER CONSERVATION DISTRICT, IN
DRIVEWAYS SIGN
23.03'
l l As p 60.82' SIGHT D
MONTROSE STATION ROAD
Wa f
N 37° 28' 00" E Masonry UPo278
le
TERMS OF RECOGNITION OF LIMITATION OF SOILS ON STEEP SLOPES FOR DEVELOPMENT AND APPLICATION OF ALL
o
MITIGATING MEASURES AND AS DEEMED NECESSARY BY THE APPROVAL AUTHORITY. 33.36'
Ed ge Pier Edge of Asphalt Typ. LOCATION:
ne Edge of Asphalt
Sto 77 MONTROSE STATION ROAD
17. TOPSOIL SHALL BE STRIPPED FROM ALL AREAS OF DISTURBANCE, STOCKPILED AND STABILIZED IN A MANNER TO
Stone UPole WATER
t
MINIMIZE EROSION AND SEDIMENTATION AND REPLACED ELSEWHERE ON THE SITE AT THE TIME OF FINAL GRADING.
Retaining Wall sp hal Typ. VALVE TYP PROPOSED WATER
TOWN OF CORTLANDT, NEW YORK
of A
STOCKPILING SHALL NOT BE PERMITTED ON SLOPES OF GREATER THAN 10%. APPROXIMATE LOCATION OF SHUTOFF VALVE &
HYDRANT PROPOSED WATER APPROX. LOCATION OF EXISTING 16"Ø CAST IRON
18. NO ORGANIC MATERIAL OR ROCK WITH A SIZE THAT WILL NOT ALLOW APPROPRIATE COMPACTION OR COVER BY
e EXISTING WATER METER PIT WATER METER PIT
Edg
140 SHUTOFF VALVE & WATER MAIN (NWJWW TRANSMISSION MAIN)
TOPSOIL SHALL BE USED AS FILL MATERIAL. FILL MATERIAL SHALL BE NO LESS GRANULAR THAN THE SOIL UPON SHEET 5 OF 8
UG-4.1
FOR 77 MONTROSE STATION WATER METER PIT
WHICH IT IS PLACED AND SHALL DRAIN READILY. ENTRANCE SHALL BE MONTROSE IMPROVEMENT DISTRICT SERVICE
RD (LOT 1)
19. COMPACTION OF FILL MATERIALS IN FILL AREAS SHALL BE SUCH TO ENSURE SUPPORT OF PROPOSED
STRUCTURES AND STABILIZATION FOR INTENDED USES.
LOCATED AT HIGH POINT AREA WCDH SHEET 1 OF 1
Page 9
PROPOSED
4-BDRM
EXISTING RESIDENCE
GRADE
1.5% GARAGE = 171.0
170 170
Cortlandt
PROPOSED
ASPHALT
TR
DRIVEWAY
160 160
A
VI
SITE
S
RD
LN
N
O
13.3%
I
AT
ST
SE
RO
NT
O
M
150 MONTROSE 4.0% 0 150
18
STATION ROAD
PROFILE THRU PROPOSED LOT 2 DRIVEWAY & RESIDENCE OA
KR
D
HORIZONTAL SCALE: 1" = 20'
L RD
VERTICAL SCALE: 1" = 10' GE HIL
COLLE
LOCATION MAP SCALE: 1" = 600'
PROPOSED LOT LINES (TYP.)
PROPOSED
170 4-BDRM 170
RESIDENCE
EXISTING
GRADE
'
15 PROPOSED
.
90 ASPHALT 2.0% GARAGE = 162.0
2 DRIVEWAY
160 160
6%
0
17
15 7%
0
ROOF LEADER DISCHARGE
PIPE 4" PVC SDR 35 17
0
150 MONTROSE 4.0% 150
INV OUT 165.0
STATION ROAD
INTO CULTECS 160.5
DECK PROFILE THRU PROPOSED LOT 3 DRIVEWAY & RESIDENCE
HORIZONTAL SCALE: 1" = 20'
PROPOSED (4) CULTEC 330XLHD RECHARGER VERTICAL SCALE: 1" = 10'
INFILTRATORS
40 0 20 40
PROPOSED 4-BEDROOM +170.8
FOOTING DRAIN DISCHARGE PIPE 4" PVC SDR35
INV. 160.0 RESIDENCE
171.00'
PROPOSED
SCALE: 1" = 40 FT.
GARAGE 171.0 ASPHALT
DRIVEWAY
1ST FL 172.5 PROPOSED (4) CULTEC 330XLHD RECHARGER
BASEMENT 162.5 INFILTRATORS OWNER/APPLICANT
336.83'
172.0+ 77 MONTROSE STATION, LLC
1340 BAPTIST CHURCH ROAD
168
WALKWAY YORKTOWN HEIGHTS, NY 10598
160
164
17
0
· UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
PROPOSED LOT 3 UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
97,001 SF ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
ROOF LEADER DISCHARGE PIPE 4" PVC SDR35
ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
INV OUT 160.0
170 SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
INTO CULTECS 154.5
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
· COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
ENGINEERING". ALL RIGHTS RESERVED.
· AUTHORIZATION No. 130827
156
DECK
REVISIONS
5
180
4 UPDATE FOR FINAL SUBD APPROVAL JUNE 17, 2026
PROPOSED LOT 2
PROPOSED 4-BEDROOM
158
80,891 SF 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
PROPOSED
ASPHALT
RESIDENCE 2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
DRIVEWAY GARAGE 162.0 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
160
1ST FL 163.5 # REASON DATE
MUNICIPAL TAX IDENTIFICATION:
160
BASEMENT 153.5
161.8+ FOOTING DRAIN DISCHARGE PIPE 4"
SECTION: 44.17
PROPOSED INFILTRATION TRENCH (TYP) 1 70 PVC SDR35 BLOCK: 1
163.0+ INV. 151.0
170
199.48'
160 LOT: 6 & 11
168 WALKWAY SUBLOT: -----
PROPOSED 2'x2' DRAWN BY: AD
166
DRAIN INLET CHECKED: KS/PMB
PROPOSED 1" TYPE K COPPER RIM: 152.00'
108.96'
WATER SERVICE INV OUT: 150.00' 164 PROJECT: 77 MONTROSE STATION RD
DATE: JANUARY 22, 2025 EXPIRATION DATE: 03-31-2027
162 PATRICK M. BELL, P.E.
JOB #: 240601 LICENSE #087679
160 150
C N N
158
PROPOSED
16
8"
HDPE 0 PIPE
N N N
NAL N N N C N L N
140
150 PROPOSED 1" (914) 736-3664
15 TYPE K COPPER
0
WATER SERVICE
39 Arlo Lane
Cortlandt Manor, New York 10567
Properties Not ContiguousUTILITY + GRADING PLAN / DRIVEWAY PROFILES
- Overlap Exists
Drain Inlet
Rim=145.17 PROPOSED 2'x2'
PROPOSED WATER SHUTOFF VALVE &
WATER METER PIT
DRAIN INLET
RIM :152.00'
SUBDIVISION &
INV OUT: 150.00' UPole
Typ.
SITE DEVELOPMENT PLAN
PROPOSED 2'x2' FOR
PROPOSED WATER SHUTOFF VALVE &
UPole WATER
VALVE TYP
DRAIN INLET WATER METER PIT 77 MONTROSE STATION, LLC
Typ. PROPOSED 2'x2' RIM: 149.00'
DRAIN INLET INV OUT: 147.00'
PROPOSED 8" HDPE PIPE
UNDER DRIVEWAY FROM RIM: 149.00'
APPROXIMATE LOCATION OF EXISTING WATER METER PIT CATCH BASIN TO EXISTING INV OUT: 146.50' APPROX. LOCATION OF EXISTING 16"Ø CAST IRON WATER MAIN LOCATION:
FOR 77 MONTROSE STATION RD (LOT 1) (NWJWW TRANSMISSION MAIN)
140 TOWN DRAIN INLET 77 MONTROSE STATION ROAD
MONTROSE IMPROVEMENT DISTRICT SERVICE AREA
TOWN OF CORTLANDT, NEW YORK
ENTRANCE SHALL BE LOCATED AT HIGH POINT PROPOSED 8" HDPE PIPE
UNDER DRIVEWAY
PROPOSED 8" HDPE PIPE UNDER DRIVEWAY FROM CATCH BASIN
TO EXISTING TOWN DRAIN INLET
SHEET 6 OF 8 UG-4.2
Page 10
EROSION AND SEDIMENT CONTROL NOTES EROSION CONTROL + TREE PLAN
LANDSCAPE PLANTING CHART 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SEDIMENT AND EROSION CONTROL PRACTICES. THE SEDIMENT AND EROSION SCALE: 1" = 50' ' (
)
ed )
De rvey
CONTROL PRACTICES ARE TO BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCES, AND MAINTAINED UNTIL PERMANENT PROTECTION IS 35 Su
SIZE 7. 3'(
ESTABLISHED. 67 5.7
QUANTITY SYMBOL BOTANICAL NAME COMMON NAME COMMENTS 68
CALIPER HEIGHT VOLUME 2. TIMELY MAINTENANCE OF SEDIMENT CONTROL STRUCTURES IS THE RESPONSIBILITY OF THE CONTRACTOR. ALL STRUCTURES SHALL BE
(IN.) (FT.) (GAL.) MAINTAINED IN GOOD WORKING ORDER AT ALL TIMES. THE SEDIMENT LEVEL IN ALL SEDIMENT TRAPS SHALL BE CLOSELY MONITORED AND
SEDIMENT REMOVED PROMPTLY WHEN MAXIMUM LEVELS ARE REACHED OR AS ORDERED BY THE ENGINEER. ALL SEDIMENT CONTROL
10 SM ACER SACCHARUM SUGAR MAPLE 3" ----- ----- SEE PLAN STRUCTURES SHALL BE INSPECTED WEEKLY, PRIOR TO EXPECTED RAIN EVENTS, AND AFTER EACH HEAVY RAIN TO INSURE PROPER OPERATION Tax Lot 44.17-2-1
AS DESIGNED. AN INSPECTION SCHEDULE SHALL BE SET FORTH PRIOR TO THE START OF CONSTRUCTION. N/F Michael Simmon
Cortlandt
4 WO QUERCUS ALBA WHTE OAK 3" ----- ----- SEE PLAN & Jennifer Budner
3. THE LIMIT OF DISTURBANCES SHALL BE CLEARLY STAKED AND FLAGGED IN THE FIELD PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY. NO
'
TR
LAND DISTURBANCE, EQUIPMENT ACCESS, OR MATERIAL STAGING SHALL OCCUR OUTSIDE THE PROPOSED LIMITS OF DISTURBANCES. THE
.35
AV
6 RO QUERCUS RUBRA RED OAK 3" ----- ----- SEE PLAN CONTRACTOR SHALL MAINTAIN THE LIMIT OF DISTURBANCE MAKERS FOR THE DURATION OF THE CONSTRUCTION.
SITE
IS
84
RD
LN
N
IO
NOTE: ALL PROPOSED TREES SHALL HAVE A MINIMUM DIAMETER OF 3" AT 4-1/2' ABOVE GROUND. AT
5. THE LOCATIONS AND THE INSTALLATION TIMES OF THE SEDIMENT CAPTURING STANDARDS SHALL BE AS ORDERED BY THE ENGINEER, AND IN ST
Stone Wall
SE
ACCORDANCE WITH ACCEPTED STANDARDS. RO
NT
O
M
6. CATCH BASIN INLET PROTECTION MUST BE INSTALLED AND OPERATING AT ALL TIMES UNTIL TRIBUTARY AREAS HAVE BEEN STABILIZED. WHEN
POSSIBLE FLOWS SHOULD BE STABILIZED BEFORE REACHING INLET PROTECTION STRUCTURE. MAINTENANCE OF SEDIMENT CONTROL .
5'
34.0
7. ALL TOPSOIL NOT TO BE USED FOR FINAL GRADING SHALL BE REMOVED FROM THE SITE IMMEDIATELY AND PLACED IN A STABILIZED STOCKPILE
OR FILL AREA. ALL TOPSOIL REQUIRED FOR FINAL GRADING AND STORED ON SITE SHALL BE LIMED, FERTILIZED, TEMPORARILY SEEDED AND
MULCHED WITHIN 14 DAYS.
8. ANY DISTURBED AREAS THAT WILL BE LEFT EXPOSED MORE THAN 21 DAYS AND NOT SUBJECT TO CONSTRUCTION TRAFFIC, SHALL OA
KR
D
IMMEDIATELY RECEIVE TEMPORARY SEEDING. MULCH SHALL BE USED IF THE SEASON PREVENTS THE ESTABLISHMENT OF A TEMPORARY COVER.
0'
3.0
DISTURBED AREAS SHALL BE LIMED AND FERTILIZED PRIOR TO TEMPORARY SEEDING. GE HIL
L RD
COLLE
11
9. ALL DISTURBED AREAS WITHIN 500 FEET OF AN INHABITED DWELLING SHALL BE WETTED AS NECESSARY TO PROVIDE DUST CONTROL.
10. THE CONTRACTOR SHALL KEEP THE ROADWAYS WITHIN THE PROJECT AREA CLEAR OF SOIL AND DEBRIS AND IS RESPONSIBLE FOR ANY STREET
CLEANING NECESSARY DURING THE COURSE OF THE PROJECT. LOCATION MAP SCALE: 1" = 600'
11. SEDIMENT AND EROSION CONTROL STRUCTURES SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE DRAINAGE AREA HAS BEEN
PROPERLY STABILIZED BY PERMANENT MEASURES.
12. SOIL SEEDING AND FERTILIZER AMENDMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITION OF "NEW YORK GUIDELINES
FOR URBAN EROSION AND SEDIMENT CONTROL". Tax Lot 44.17-1-12
WHITE OAK TREE SUGAR MAPLE RED OAK Tax Lot 44.17-1-9 & 10 N/F Eugine M. Cesar-Fabian
13. ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION OF "NEW YORK N/F Thomas H. Hintze EX & Marie Fabian
GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL". Irrevocable Trust IS
RE 5-BD TIN
SI R G
DE M
LANDSCAPING NOTES NC
E
62.02'
1. ALL LANDSCAPING (PLANTING OF TREES, SHRUBS, SOD, ETC.) SHALL BE PERFORMED BY OR UNDER THE
SUPERVISION OF A PERSON WHO MEETS AT LEAST ONE OF THE FOLLOWING CRITERIA: CERTIFIED NURSERY
2' .1
PROFESSIONAL, ISA CERTIFIED ARBORIST, CERTIFIED LANDSCAPE TECHNICIAN PROGRAM OR GRADUATE
88
FROM A 2 YEAR COLLEGE IN THE FIELD OF HORTICULTURE, ENVIRONMENTAL SCIENCE, LANDSCAPE
ARCHITECTURE OR FORESTRY. EX 19.87'
GA IST
'
.32
RA ING
2. ALL PLANTS MUST BE HEALTHY AND REPRESENTATIVE OF THE FORM OF THE SPECIES. GE
96
3. TREES TO BE PLANTED IMMEDIATELY AFTER DELIVERY FROM THE NURSERY.
4. CONTRACTOR TO ASSURE SUITABLE SOIL CONDITION, IF NECESSARY PROVIDE ORGANIC MATTER-COMPOST,
375.00'
NUTRIFIED BARK, IN THE PROPORTION OF 2 PARTS OF SOIL TO 1 PART OF ORGANIC MATTER.
5. WATERING BASIN FOR TREES TO BE AT LEAST 30" IN DIAMETER OR THREE TIMES THE SIZE OF THE ROOTBALL. 351 50 0 25 50
6. BACKFILLING OF PLANT BASIN TO BE WITH THE ORIGINAL SOIL TO THE LEVEL OF 2 TO 4 INCHES ABOVE THE 50' Wide Right of Way
ORIGINAL LEVEL. Per Deed Liber 2120, Page 12 352
353
7. PROVIDE APPROPRIATE WATERING AND IF NECESSARY WRAP THE TRUNK TO LIMIT DAMAGE FROM INSECTS. SCALE: 1" = 50 FT.
8. ALL STAKING AND PIT DETAILS SHALL BE IN ACCORDANCE WITH THE NYS STANDARD SHEETS SECTION 611-1R1
356 354
STONE WALLS TYP. 357
9. CONTRACTOR TAKES ALL RESPONSIBILITY FOR MAINTAINING A SAFE CONSTRUCTION AND
POST-CONSTRUCTION CONDITION. Tax Lot 44.17-1-9 & 10 358
OWNER/APPLICANT
N/F Thomas H. Hintze 355
10. A GRASS SEEDING MIXTURE FOR THE PROPOSED LAWN AREAS WILL BE 50% KENTUCKY BLUE, 25% PERENNIAL
RYE AND 25% FINE OR RED FESCUE.
Irrevocable Trust PROPOSED OWTS
PRIMARY AREA 359
442
458 77 MONTROSE STATION, LLC
11. TOPSOIL REMOVED SHALL BE REPLACED TO A DEPTH OF AT LEAST 4-INCHES OVER ALL EXPOSED GROUND 457
SURFACES EXCEPT ROCK, AND SHALL BE PLANTED OR SEEDED AND MULCHED REPEATEDLY UNTIL THE AREA 441 363 360 1340 BAPTIST CHURCH ROAD
IS STABILIZED. 455 362
PROPOSED OWTS YORKTOWN HEIGHTS, NY 10598
12. ALL TREES WHICH FAIL TO SURVIVE FOR A PERIOD OF TWO CALENDAR YEARS SHALL BE REPLACED BY PERMIT EXPANSION AREA 443 456 452 361
HOLDER AT NO EXPENSE TO TOWN OF OWNER OF THE LAND, IF OTHER THAN THE PERMIT HOLDER OF THE
4' 454 367
PERMIT. SAID REPLACEMENT SHALL BE WITHIN 60 DAYS FOLLOWING WRITTEN DEMAND FOR SUCH
439 2.5 365
REPLACEMENT FROM THE DIRECTOR OF TECHNICAL SERVICES OR WRITTEN EXTENDED PERIOD OF TIME AS
0 453
MAY BE SPECIFIED. 438 1440 451
Tax Lot 44.17-1-11 370
37 LF
364 368 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
0
437
37 LF
366
LF
16
450 372
37 LF
UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
369
37 LF
422 373
PROPOSED LOT LINES (TYP.) ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
37 LF
449 374 375 ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
37 LF
24
0
423
37 LF
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
16
448
1. 377 371
37
S 25° 44' 00" E (Survey) 67
459 DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
37
EROSION AND SEDIMENT CONTROL - INSPECTION AND MAINTENANCE SCHEDULE S 26° 00' 00" E (Deed) 420 421 426
'
37
379 · COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
LF
424 425 376 398
LF
97.87' ENGINEERING". ALL RIGHTS RESERVED.
378 396
68
490 489 486 427 461 · AUTHORIZATION No. 130827
487 460
.2
469 395 397
6'
PROPOSED OWTS 485 409
PROPOSED LOT 1 491 428 470 462 380
DAILY WEEKLY MONTHLY AFTER RAINFALL MAINTAINANCE 245,821 SF PRIMARY AREA
541
488 468
463
410
381 382
399 REVISIONS
543 542 540 539 538 429 464 394 5
492 484 466 407 400
REPLACE AS 493 544 476 412 408 383
CONSTRUCTION
--- INSP. --- INSP. PROPOSED OWTS 471 392 401 4 UPDATE FOR FINAL SUBD APPROVAL JUNE 17, 2026
ENTRANCE NECESSARY 551 0 465 405 390
EXPANSION AREA
546 545 18
CLEAN / REPLACE PROPOSED SILT FENCE TYP. 550 483 411 3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
--- INSP. --- INSP. 472 467 404 403 393
SILT FENCE
AS NECESSARY 481 384
495 549 406 388 2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
PROPOSED SEPTIC TANK 548 547 478
SOIL STOCKPILE --- INSP. --- INSP. --- AND PUMP CHAMBER 385 389391 LIMIT OF DISTURBANCE FOR
473474 419 1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
494 480 413 PROPOSED
349 LOTS 2 AND 3
37 LF
ROOF LEADER DISCHARGE 417
PROPOSED LOT LINES (TYP.) 387 (±77,100 SF / 1.7 AC)
CLEAN / REPLACE 386
37 LF
LF
EROSION BLANKET --- --- INSP. INSP. PIPE 4" PVC SDR 35 565 496 477 # REASON DATE
37 LF
AS NECESSARY 479 350
418
37 LF
R=293.51'
INV OUT 165.0 ' 497 157 415 348 MUNICIPAL TAX IDENTIFICATION:
37 LF
CLEAN / REPLACE 5
INTO CULTECS 160.5 1 156
--- INSP. --- INSP. 0. 347
37 LF
INLET PROTECTION 416
AS NECESSARY L=112.50' 566 498 209
37 LF
9
PROPOSED (4) CULTEC 2 333 SECTION: 44.17
37
332 346
37
330XLHD RECHARGER
15 562 414 BLOCK:
37
1
LF
0
INFILTRATORS 158 155 0
154 210 17 344
LF
S 31° 51' 50" W (Survey)
REFORESTATION AND LANDSCAPING NOTE S 31° 35' 50" W (Deed)
17
0
208 337 338
343
345 LOT: 6 & 11
FOOTING DRAIN DISCHARGE 561 160 PROPOSED LOT 3
341
126.47' (Survey) 207 331 SUBLOT: -----
AS DETERMINED DURING THE SUBDIVISION PROCESS FOR THE DEVELOPMENT OF PROPOSED LOTS 2 AND 3 THERE WAS A TREE PIPE 4" PVC SDR35 475 97,001 SF
PLANTING SHORTFALL OF 281 TREES WHICH REQUIRES PAYMENT TO THE TOWN’S ENVIRONMENTAL RESTORATION FUND. AS PART
135.26 (Deed) INV. 160.0 560 EQUIPMENT 152 206 402
336 339 342 DRAWN BY: AD
STORAGE 153 Tax Lot 44.17-1-16
212 213
OF THE BUILDING PERMIT PROCESS FOR THE DEVELOPMENT OF LOTS 2 AND 3, THE PAYMENT TO THE TOWN’S ENVIRONMENTAL
PROPOSED 4-BEDROOM 330 327
RESTORATION FUND WILL BE REQUIRED. THE PAYMENT TO THE RESTORATION FUND CAN BE REDUCED BY A COMBINATION OF THE 558 +170.8 161 204 203 334 328
PROPOSED SILT FENCEN/F
TYP.Reid Gearhart CHECKED: KS/PMB
171.00'
PLANTING OF ADDITIONAL TREES, SHRUBS, PERENNIALS AND THE PRESERVATION OF EXISTING STONE WALLS AND THE PROVISION RESIDENCE
163 205 340 & Tiziana Mohorovic
OF THE ADDITIONAL BUFFERING TO MONTROSE STATION ROAD TO PROTECT THE EXISTING CHARACTER OF THE NEIGHBORHOOD. AT GARAGE 171.0 PROPOSED
329 326 PROJECT: 77 MONTROSE STATION RD
THE TIME OF THE BUILDING PERMIT APPLICATIONS FOR BOTH LOTS 2 AND 3, REFORESTATION PLANS AND LANDSCAPING SECURITIES 557 1ST FL 172.5 ASPHALT
164
169 162 335 320 Deed Liber #12229,
336.83'
WILL NEED TO BE SUBMITTED. THE REFORESTATION PLANS MUST BE TO THE SATISFACTION OF THE DIRECTOR OF PLANNING & 556 BASEMENT 162.5 DRIVEWAY 201 211 325 EXPIRATION DATE: 03-31-2027
COMMUNITY DEVELOPMENT AND THE DIRECTOR OF TECHNICAL SERVICES AND SUBJECT TO THE REVIEW AND COMMENTS OF THE
197 217
PROPOSED SEPTIC TANK 319 Page #339 DATE: JANUARY 22, 2025
TOWN CONSERVATION ADVISORY COUNCIL. THE LANDSCAPING SECURITY SHALL BE FOR TWO TIMES (2X) THE COST OF THE PLANT
165 216
AND PUMP CHAMBER 318 PATRICK M. BELL, P.E.
172.0+ 214 324 317 JOB #: 240601
168
MATERIAL PLUS LABOR AND SHALL BE IN PLACE FOR TWO (2) GROWING SEASONS. INSPECTIONS BY THE DEPARTMENT OF 166 202 LICENSE #087679
TECHNICAL SERVICES SHALL BE DONE ANNUALLY FOR THE TWO-YEAR PERIOD AND ANY PLANTS THAT DIE MUST BE REPLACED ON A
555 WALKWAY 168 200 321
167
164
RATIO OF 1:1. 552 PROPOSED (4) CULTEC
SOIL 160 316 315
17
RO 330XLHD RECHARGER
C N N
0
SOIL STOCKPILING 322 314 INFILTRATORS
171 186 / STAGING
170 STOCKPILING EQUIPMENT
/ STAGING RO 172 313
STORAGE 312 ROOF LEADER DISCHARGE
SM PIPE 4" PVC SDR35
N N N
156
94 231
50' Wide Right of Way 93 INV OUT 160.0
243.86' (D vey)
96 230
eed)
Per Deed Liber 2120, Page 12 180 INTO CULTECS 154.5
95
ur
NAL N N N C N L N
158
243.23' (S
PROPOSED 4-BEDROOM 229
PROPOSED 92LOT 2
PROPOSED LOT LINES
WO 80,891 SF PROPOSED RESIDENCE 227 228 (914) 736-3664
GARAGE 162.0
160
ASPHALT 233
SM 185
170
PROPOSED EROSION (TYP.) WO 91 DRIVEWAY 1ST FL 163.5
232
CONTROL MATTING (TYP) 58 160 PROPOSED ACCESS & UTILITY RO BASEMENT 153.5 234
Tax Lot 44.17-1-6 59 90
EASEMENT FOR THE BENEFIT
17
0 161.8+ 311 FOOTING DRAIN
39 Arlo Lane
199.48'
89 OF LOT 3 OVER LOT 2 SM 163.0+ DISCHARGE PIPE
Tax Lot 44.17-2-3 160 4" PVC SDR35
120 SM 168 WALKWAY 310 307 Cortlandt Manor, New York 10567
N/F Anne Sumers 60 309 306 INV. 151.0
61 121 166
130
108.96'
Deed Control # 3962 164
SM
38
442250322 14
0
118
WO
162 SM SM
295 294
293
308 EROSION CONTROL + TREE PLAN /
116 SM 305
37 117 SM
160 292 150 CONSTRUCTION DETAILS
13 158 260 270 303
15
0
12 66 70 297 269 304
119 RO 290
65 16
0 WO 296 291 287
289
1 6
11
14
67 68 69
SM 267
288
140
284 SUBDIVISION &
5 19 283
2
15
100 9 15 63
64
21 23
150 RO
RO 80 261
266
268 275 286 282 SITE DEVELOPMENT PLAN
7 271
3 8 17 16 18 20
22
262 263 264 265
273 274 276 285 FOR
272 281
4 280 Properties Not Contiguous
77 MONTROSE STATION, LLC
N 53° 26' 00" E 76 77 78 277 - Overlap Exists
Drain Inlet 279
36.37' 0 Rim=145.17
15
278
LOCATION:
77 MONTROSE STATION ROAD
PROPOSED STABILIZED TOWN OF CORTLANDT, NEW YORK
CONSTRUCTION ENTRANCE
140
ENTRANCE SHALL BE
LOCATED AT HIGH POINT
SHEET 7 OF 8 ESC-5.1
Page 11
THE FOLLOWING ARE THE MOST RECENT WATER SERVICE PRODUCTS
APPROVED BY DES (SUBJECT TO CHANGE): 2" ASPHALT TOP COURSE, NYSDOT
SAWCUT TRENCH TO
PROPERTY LINE
ITEM 403.178302 TYPE 6 F3
OR EASEMENT
· MUELLER 1" H-15000N CORPORATION VALVE THE BOTTOM OF THE
4"-6" TOPSOIL OVERFILL ROAD COURSE 4"-6" TOPSOIL OVERFILL
· MUELLER 15214 CURB STOP AND DRAIN FOR SETTLING PURPOSES
· MUELLER 15204N ADJUSTABLE CURB BOX MATERIAL (ITEM 4) WITH FOR SETTLING PURPOSES
SAW CUT
CURB STOP & BOX AT A STRAIGHT AND
SAW CUT
EXISTING / FINAL GRADE PROPERTY LINE OR EDGE VERTICAL EDGE, TACK
OF EASEMENT COVER TO 1'-6" COAT ALL EXPOSED
BE MARKED "WATER" MIN EDGES WITH RC-250
CURBING (WHERE APPLICABLE) 1' 1'
MIN MIN EXISTING ROAD
SURFACE Ø + 24"
ROAD SURFACE (WHERE APPLICABLE)
MIN
CLEAN GRANULAR FILL ONLY
Cortlandt
4'
SWALE
VARIES
NO STONES GREATER THAN 3" 4" ASPHALT BINDER COURSE,
AND NO ORGANIC MATERIAL NYSDOT ITEM 403.138902 TYPE 3
CURB BOX W/
ROD (MUELLER) PERMITTED. CLEAN FILL TO RUN 8" (COMPACTED) ITEM 4, NYSDOT
TR
FULL LENGTH OF TRENCH CLEAN GRANULAR FILL ONLY
AV
ITEM 304.12 TYPE 2
SITE
IS
NO STONES GREATER THAN 3"
MIN
RD
3'-9"
LN
MIN
1'
CLEAN GRANULAR FILL ONLY AND NO ORGANIC MATERIAL 1' 1' 6" - 9" RIP RAP N
MIN
1'-6" IO
4'
CLEAN GRANULAR FILL ONLY NO ORGANIC MATERIAL PERMITTED. CLEAN FILL TO RUN MIN Ø MIN AT
MIN
PROPOSED 1" TYPE "K" MIN ST
4'
W
MIN
COPPER PIPE PROPOSED 1" TYPE NO STONES GREATER THAN 3" PERMITTED. CLEAN FILL TO RUN FULL LENGTH OF TRENCH SE
6"
AND NO ORGANIC MATERIAL RO
"K" COPPER PIPE FULL LENGTH OF TRENCH (OR K-CRETE 3' NT
45° PERMITTED. CLEAN FILL TO RUN OR ITEM 4 AS SPECIFIED PER MUNICIPALITY) D M
O
Ø
FULL LENGTH OF TRENCH POUROUS BEDDING MATERIAL TO TOP OF
MIN
WATER SERVICE PIPING
6"
TO RESIDENCE (THIS SECTION TO BE COMPACTED (SEE PLAN FOR SIZE & PIPE (OR AS SPECIFIED BY MUNIPALITY)
W
IN 6" LIFTS) MATERIAL) SAND PIPE BEDDING
MIN
FULL LENGTH OF TRENCH DRAINAGE PIPE SHALL REST ON
6"
(THIS SECTION TO BE COMPACTED VIRGIN (UNDISTURBED) DRAINAGE PIPING
UNDISTURBED OR COMPACTED EARTH SOLID GROUND OR (SEE PLAN FOR SIZE)
IN 6" LIFTS)
WATER SERVICE PIPING 6" OF SAND WHERE
WATER MAIN BEDROCK IS ENCOUNTERED
(SEE PLAN FOR SIZE & UNDISTURBED OR COMPACTED EARTH 2'
BRICK BENEATH CURB MATERIAL)
WATERMAIN INSTALLATION NOTES: 6" - 9" RIP RAP OA
KR
STOP AND DRAIN D
1. NO ROCK SHALL PROJECT WITHIN THE SURFACE OF THE TRENCH AND ALL ROCK SHALL BE A MINIMUM OF 12" UNDISTURBED OR COMPACTED EARTH DRAIN PIPE INSTALLATION NOTES: L RD
CRUSHED STONE GE HIL
FROM THE PIPE HORIZONTALLY. IF BEDROCK IS ENCOUNTERED DURING INSTALLATION, IT SHALL BE COLLE
WATERMAIN INSTALLATION NOTES: 1. NO ROCK SHALL PROJECT WITHIN THE SURFACE OF THE TRENCH AND ALL ROCK SHALL BE A MINIMUM OF 12" FROM THE PIPE
SAND TO 6" ABOVE WATER SERVICE EXCAVATED TO A MINIMUM DEPTH OF 4' + PIPE + 6" AND REPLACED WITH 6" OF SAND.
CURB STOP (MUELLER)
TO RUN FULL LENGTH OF TRENCH FLARE NUT FOR HORIZONTALLY. IF BEDROCK IS ENCOUNTERED DURING INSTALLATION, IT SHALL BE EXCAVATED TO A MINIMUM DEPTH OF 12"
(SEE PLAN FOR SIZE) 1. NO ROCK SHALL PROJECT WITHIN THE SURFACE OF THE TRENCH AND ALL ROCK SHALL BE A MINIMUM OF 12"
(THIS SECTION TO BE COMPACTED COPPER SERVICE 2. CLAY, SILT LOAM, OR NON-HOMOGENOUS SOILS REQUIRE SHORING AND BRACING. INVERT AS SPECIFIED ON SITE DEVELOPMENT PLANS + 6" AND REPLACED WITH 6" OF SAND.
FROM THE PIPE HORIZONTALLY. IF BEDROCK IS ENCOUNTERED DURING INSTALLATION, IT SHALL BE
UNDISTURBED OR
IN 6" LIFTS)
3. SHEETING AND BRACING SHALL BE USED IN ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR
INDUSTRIAL CODE, RULE 753 WHERE REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH
EXCAVATED TO A MINIMUM DEPTH OF 4' + PIPE + 6" AND BEDDING AND TRENCH BACKFILL MATERIAL SHALL
BE No. 57 CRUSHED STONE. 2. CLAY, SILT LOAM, OR NON-HOMOGENOUS SOILS REQUIRE SHORING AND BRACING.
EXISTING GEOTEXTILE
LOCATION MAP SCALE: 1" = 600'
COMPACTED EARTH DEPTHS EXCEED 5' IN HEIGHT. 3. SHEETING AND BRACING SHALL BE USED IN ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR INDUSTRIAL GROUND FABRIC
2. CLAY, SILT LOAM, OR NON-HOMOGENOUS SOILS REQUIRE SHORING AND BRACING. VARIES
CODE, RULE 753 WHERE REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH DEPTHS EXCEED 5' IN HEIGHT.
4. ANY UNSUITABLE MATERIAL EXCAVATED FROM THE TRENCH SHALL NOT USED AS BACKFILL AND SHALL BE
REPLACED BY SUITABLE MATERIAL APPROVED BY THE DESIGN ENGINEER.
3. SHEETING AND BRACING SHALL BE USED IN ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR N.T.S.
INDUSTRIAL CODE, RULE 753 WHERE REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH 4. ANY UNSUITABLE MATERIAL EXCAVATED FROM THE TRENCH SHALL NOT USED AS BACKFILL AND SHALL BE REPLACED BY
DEPTHS EXCEED 5' IN HEIGHT. SUITABLE MATERIAL APPROVED BY THE DESIGN ENGINEER.
RIP RAP DISPERION PAD INSTALLATION
WATER SERVICE CONNECTION N.T.S. 4. ANY UNSUITABLE MATERIAL EXCAVATED FROM THE TRENCH SHALL NOT USED AS BACKFILL AND SHALL BE
WATER SERVICE INSTALLATION REPLACED BY SUITABLE MATERIAL APPROVED BY THE DESIGN ENGINEER.
DRAIN PIPE INSTALLATION
CEMENTED SAND & GRAVEL
N.T.S.
WATER SERVICE INSTALLATION
COMPACTED SHARP SAND
N.T.S.
W/O PAVEMENT RESTORATION W/O PAVEMENT RESTORATION
WELL ROUNDED LOOSE
COMPACTED ANGULAR
N.T.S.
W/ PAVEMENT RESTORATION
SOLID ROCK, SHALE,
AVERAGE SOILS
GRAVELS
2'
SAND
STABILIZE ENTIRE SOIL PILE WITH FAST SILT FENCE *
GRADE GROWING VEGETATION OR COVER (SEE DETAIL) DENSE COVER OF REED
STRAW BALE DIKE* 2 CANARY GRASS
VERTICAL SLOPE
1 1 113 2
FILTER X, MIRAFI 100X, OR 10' (SEE DETAIL) MAX. 1
1 1 3
2 1 STABILINKA T140N FILTER 1
CLOTH OR APPROVED EQUAL MAX. 6"
6"
WOVEN WIRE FENCE (MIN. 14 12
GAUGE W/ MAX 6" MESH SPACING MAX.
AS DEEMED NECESSARY BY OWNER/APPLICANT
MAX
QUALIFIED INSPECTOR.)
5'
TRENCH WIDTH 2" X 2" WOOD POST, NO. 2 6"
RE-BAR OR STEEL PICKETS
MAX.
TILL SURFACE TO RESTORE EXISTING/PROPOSED
INFILTRATION GRADE
MIN.
EXISTING SUBSURFACE SOIL
30"
INSTALLATION NOTES:
FLO
W FILTER X, MIRAFI 100X, OR 77 MONTROSE STATION, LLC
TRENCH EXCAVATION & SLOPING NOTES:
STABILINKA T140N FILTER 1. AREA CHOSEN FOR STOCK PILING OPERATIONS TO BE DRY AND STABLE.
1340 BAPTIST CHURCH ROAD
GRASS SWALE CONSTRUCTION N.T.S.
1. SHEETING AND BRACING SHALL BE USED IN ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR INDUSTRIAL CODE, RULE 753 CLOTH OR APPROVED EQUAL 2. MAXIMUM SLOPE OF PILE TO BE 1 VERTICAL ON 2 HORIZONTAL.
WHERE REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH DEPTHS EXCEED 5' IN HEIGHT.
WOVEN WIRE FENCE (MIN. 14 12 GAUGE W/
3. REFER TO STRAW BALE DIKE AND SILT FENCE INSTALLATION DETAILS IN THIS PLAN SET FOR INSTALLATION
GUIDELINES.
YORKTOWN HEIGHTS, NY 10598
MIN.
MAX 6" MESH (AS DEEMED NECESSARY BY
18"
2. CLAY, SILT, LOAM OR NON-HOMOGENOUS SOILS REQUIRE SHORING AND BRACING. PRESENCE OF GROUND WATER REQUIRES SPECIAL
TREATMENT
6" QUALIFIED INSPECTOR.)
* EITHER A STRAW BALE DIKE OR SILT FENCE MAY BE USED FOR INLET PROTECTION AS SPECIFIED BY QUALIFIED INSPECTOR.
MIN.
3. SOURCE- U.S. DEPARTMENT OF LABOR (OSHA)
2" X 2" WOOD POST, NO. 2 SOIL STOCKPILING CONSTRUCTION N.T.S. 1"
RE-BAR OR STEEL PICKETS
TRENCH EXCAVATION & SLOPING
TOE-IN FILTER FABRIC,
N.T.S. BACKFILL AND TAMP SOIL TO
SECURE FABRIC IN PLACE FRONT VIEW
SET TOP OF BLANKET
SECTION VIEW IN A 6"x6" TRENCH OUTLET
BACKFILL W/ SOIL
1"
FILTER X, MIRAFI 100X, OR
15' LONG STABILINKA T140N FILTER · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
MIN. CLOTH OR APPROVED EQUAL UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
WOVEN WIRE FENCE (MIN. 14 12 ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
GAUGE W/ MAX 6" MESH SPACING PLAN VIEW SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
AS DEEMED NECESSARY BY
QUALIFIED INSPECTOR.)
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
1"
ENTRANCE TO STREET
it h it h · COPYRIGHT "2026" BY PMB ENGINEERING, PLLC OPERATING AS "CRONIN
EXISTING / FINAL GRADE ENGINEERING". ALL RIGHTS RESERVED.
10' MIN. AT SITE
W MOUNT FRAME ON · AUTHORIZATION No. 130827
O
FL
MAX 2 BRICKS OR 1 BLOCK LEVELING
PROVIDE 3" CLEAN CRUSHED COURSE (ADJUSTMENTS GREATER THAN
12" SHALL BE MADE WITH PRECAST RING) 1"
BED OF MORTAR
REVISIONS
0"
STONE OR GRAVEL
OUTLET
OVERLAP BLANKETS 4" MIN.
JOINING SECTIONS 5
1"
STAPLE ALONG SEAMS AT 12" O.C.
1"
TOP VIEW AND WITHIN BLANKET @ 3' O.C. 1" JUNE 17, 2026
WITH 8" WIRE STAPLES 4 UPDATE FOR FINAL SUBD APPROVAL
3 UPDATE FOR WCDH REALTY SUBD APPL SUBMISSION FEBRUARY 6, 2026
0"
TOE-IN FILTER FABRIC, EARTH
BACKFILL AND TAMP SOIL TO SLOPE 6" CRUSHED STONE
SECURE FABRIC IN PLACE OR GRAVEL 2 LABELLA COMMENTS DATED 10-07-2025 NOVEMBER 20, 2025
PLAN ISOMETRIC VIEW.
FL
OW VIRGIN GROUND
(UNDISTURBED SOLID SOIL)
1 LABELLA COMMENTS DATED 02-13-2025 AUGUST 20, 2025
PROVIDE 3" CLEAN CRUSHED 6" X 6" X 6" TRENCH
EXAMPLE SECTION VIEW # REASON DATE
STONE OR GRAVEL TO DEPTH OF 1' INSTALLATION NOTES:
INSTALLATION NOTES: SLOPE STABILIZATION DETAIL MUNICIPAL TAX IDENTIFICATION:
NOTES:
1. PIPES SHALL BE CUT FLUSH WITH INSIDE WALL OF BASIN.
PROVIDE GEOTEXTILE FILTER
1. EXCAVATE A 4 INCH X 4 INCH TRENCH ALONG THE LOWER SIDE OF A SLOPE AS SPECIFIED ON SITE PLAN.
1. STABILIZE PREPARED EARTHEN SLOPE WITH A BIODEGRADABLE NATURAL FIBER NETTING 2. BASINS MUST BE DESIGNED FOR H-20 LOADING AND SHALL BE AS MANUFACTURED SECTION: 44.17
2. UNROLL A SECTION AT A TIME AND POSITION THE POSTS AGAINST THE BACK (DOWNHILL) WALL OF THE
FABRIC ON SIDES AND BOTTOM TRENCH (NET SIDE AWAY FROM DIRECTION OF STORM WATER FLOW). APPROVED TYPES ARE AS FOLLOWS: BY WOODARD'S CONCRETE PRODUCTS, INC. AND BE OF MODEL CB-2X2 OR
BLOCK: 1
3. DRIVE THE POST INTO THE GROUND UNTIL THE NETTING IS APPROXIMATELY 2 INCHES FROM THE TRENCH -C350 -NORTH AMERICAN GREEN #1-800-772-2040 APPROVED EQUAL.
BOTTOM.
COMPACT SUBGRADE 4. LAY THE TOE-IN FLAP OF FABRIC FLAT IN THE BOTTOM OF THE TRENCH AND BACKFILL THE TRENCH AND TAMP
-ECOCOIR 9000- EASTERN PRODUCTS, INC. #1-201-234-5050 3. CATCH BASIN SPECIFICATION SHALL HAVE CAMPBELL FOUNDRY FRAME AND LOT: 6 & 11
-ERO-MAT V125C- EROSION CONTROL TECH. #1-800-245-0551
THE SOIL OVER THE FLAP TO SECURELY HOLD THE FABRIC IN PLACE. STEEPER SLOPES REQUIRE AN GRATE PATTERN #2815 OR APPROVED EQUAL (DROP INLET).
INTERCEPT TRENCH. -ALL SLOPE RESTORATION TO GET 4" TOPSOIL 4. ALL BACKFILL AROUND STRUCTURES (I.E. MANHOLES, CATCH BASINS, ETC) MUST SUBLOT: -----
SECTION 5.
6.
JOIN SECTIONS AS SHOWN ABOVE
PREFABRICATED UNITS SHALL BE OF TYPE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. 2. SEED SLOPE PRIOR TO INSTALLING EROSION CONTROL NETTING. BE COMPACTED TO 95% PROCTOR DENSITY TO AVOID SETTLEMENT OF MATERIAL
AROUND THE STRUCTURE. DRAWN BY: AD
SILT FENCE INSTALLATION N.T.S. SLOPE STABILIZATION BLANKET
INSTALLATION N.T.S. 5. SIZE, MATERIAL, PITCH AND INVERT ELEVATIONS OF ALL PIPING TO BE AS
SPECIFIED ON SITE DEVELOPMENT PLANS.
CHECKED: KS/PMB
6. GRATE INVERTS SHALL BE SET AS SHOWN ON THE SITE DEVELOPMENT PLANS. PROJECT: 77 MONTROSE STATION RD
INSTALLATION NOTES: 7. BASINS TO BE CHECKED PERIODICALLY DURING CONSTRUCTION BY A QUALIFIED
INSPECTOR AND CLEANED OUT AS NECESSARY DURING CONSTRUCTION. DATE: JANUARY 22, 2025 EXPIRATION DATE: 03-31-2027
1. STONE SIZE SHALL BE 3" STONE OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT ONLY. PATRICK M. BELL, P.E.
NOTE: JOB #: 240601 LICENSE #087679
YARD DRAIN INSTALLATION
STANDARD STEEL OR WOOD FENCE POSTS
2. LENGTH SHALL BE AS SHOWN BUT NOT LESS THAN 15' (SEE NOTES 1 & 2) FOR USE DURING INDIVIDUAL LOT CONSTRUCTION N.T.S.
AND ANYWHERE THE ENGINEER DEEMS NECESSARY
OR AS SHOWN ON THE PLANS
3. THE THICKNESS SHALL BE NO LESS THAN 12" AT THE CONSTRUCTION ENTRANCE. 6'-8" TO BE PROVIDED ON THE LIMIT OF DISTURBANCE LINE
4.
5.
THE WIDTH SHALL BE 10' AT A MINIMUM BUT NOT LESS THAN THE FULL WIDTH OF THE TRAVELED WAY.
FILTER FABRIC SHALL BE PLACED OVER THE ENTIRE AREA PRIOR TO THE PLACING OF ANY STONE.
FILTER FABRIC WILL NOT BE REQUIRED ON A SINGLE FAMILY RESIDENCE CONSTRUCTION.
6'-8"
1 - 2 INCH DIA. WASHED,
CULTEC RECHARGER 330XL HD
HEAVY DUTY CHAMBER
CRUSHED STONE
TOPSOIL
95%
COMPACTED FILL
4 OZ. NON-WOVEN FILTER FABRIC
AROUND STONE
C N N
6. IF SURFACE WATER IS FLOWING TOWARD THE CONSTRUCTION ENTRANCE, IT SHALL BE PIPED 12" MIN.
N N N
UNDERNEATH THE STABILIZED ENTRANCE. IF PIPING IS IMPRACTICAL, A BERM WITH 5:1 SIDE SLOPES NAL N N N C N L N
SHALL BE PERMITTED. 6" MIN.
18" MIN. -
(914) 736-3664
7. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT THE TRACKING OR 12' [3658 mm]
FLOWING OF SEDIMENT FROM CONSTRUCTION INTO THE PUBLIC RIGHT OF WAY. THIS MAY REQUIRE 4'-0" 2' MAX. 30.5"
PERIODIC DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR
CLEANOUT OF ANY MEASURES USED TO CAPTURE SEDIMENT. ANY SEDIMENT TRACKED, DROPPED OR 39 Arlo Lane
WASHED INTO PUBLIC RIGHT OF WAY SHALL BE REMOVED IMMEDIATELY. 6" MIN
DRIVEWAY
LAWN
ROOF LEADER PIPE PER Cortlandt Manor, New York 10567
8. WHEELS OF CONSTRUCTION VEHICLES SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO PERSPECTIVE VIEW
ENGINEER DESIGN
3'-6" (MAX. INLET =
ENTERING ONTO THE PUBLIC RIGHT OF WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE IN AN CULTEC NO. 20L POLYETHYLENE SIDE PORTAL TO BE CUT
24 INCHES) 16.8" [427 mm]
AREA STABILIZED WITH STONE AND WHICH DRAINS INTO AN APPROPRIATE SEDIMENT TRAPPING LINER TO SPAN THE ENTIRE WIDTH IN FIELD TO ALLOW HVLV
(TYP.)
CONSTRUCTION DETAILS
DEVICE. ROOF DRAINAGE CALCULATIONS (LOT 2 + LOT 3) OF THE SYSTEM BELOW THE HVLV FC-24 FEED CONNECTOR
CONSTRUCT ON LIMIT AS NEEDED NOTES
OF DISTURBANCE LINE
FC-24 FEED CONNECTORS AND ALL INSTALLATION SHALL BE IN ACCORDANCE
9. PERIODIC INPECTION AND MAINTENANCE SHALL BE PROVIDED FOR THE DURATION OF PURPOSE - CAPTURE AND TREAT ROOF RUNOFF SIDE PORTALS
STANDARD STEEL OR WITH THE MANUFACTURERS SPECIFICATIONS
DESIGN - NYSDEC WATER QUALITY VOLUME
CONSTRUCTION OR UNTIL FINAL GRADE IS ACHIEVED. WOOD FENCE POST
N.T.S. AREA = ROOF AREA = 2,800 SF
WQv - WATER QUALITY VOLUME
2'
CULTEC® RECHARGER 330XLHD STORMWATER SYSTEM DETAIL
CONSTRUCTION NOTES FOR PLASTIC FENCE N.T.S.
SUBDIVISION &
STABILIZED CONSTRUCTION ENTRANCE 1. SPACE SUPPORT FENCE POSTS AT 6'-8" INTERVALS.
WQv = P x Rv x A
12
FILTER SITE DEVELOPMENT PLAN
2. DRIVE SUPPORT POSTS 3'-6" INTO GROUND.
1
2 2" ASPHALT TOP COURSE
3. FIRMLY FASTEN FENCE MATERIAL IN PLACE BY WIRING
TO FENCE POST WHILE MAINTAINING TENSION ACROSS
P = 90TH PERCENTILE RAINFALL = 1.5"
Rv = 100% IMPERVIOUS, 0.05 + 0.009(I) = 0.95
FABRIC FINISHED GRADE EL: 163.0 FINISHED GRADE EL: 157.0
FOR
(NYSDOT item no. 403.178302)
77 MONTROSE STATION, LLC
FULL HEIGHT OF FENCE. WIRING SHALL BE DONE IN A A = 2,800 SF
MANNER THAT WILL PREVENT SAGGING OF FENCE MATERIAL.
CULTEC TOP EL: 161.5 CULTEC TOP EL: 155.5
4. PROVIDE PERIODIC INSPECTION AND MAINTENANCE OF WQv = (1.5) x (0.95) x (2,800) = 332.5 CU FT
FENCE INCLUDING REPAIRS AS NECESSARY AND REQUIRED. 12
5. PLASTIC FENCE MATERIAL SHALL BE MORNING BARRIER OVERFLOW OUTLET EL: 160.5 OVERFLOW OUTLET EL: 154.5
6" (COMPACTED) ITEM 4
FENCE, COLOR-INTERNATIONAL ORANGE, AS
(NYSDOT item no. 304.14) MANUFACTURED BY ADPI ENTERPRISES, INC. OR APPROVED CULTEC 330 XLHD VOLUME = 79.26 CU FT
EQUAL. SEE NOTE 3
NO. OF UNITS REQUIRED = 332.5 = 4 UNITS 1-12" WASHED CULTEC BOTTOM EL: 159.0 CULTEC BOTTOM EL: 153.0 LOCATION:
79.26 STONE GRAVEL BOTTOM EL: 158.5 GRAVEL BOTTOM EL: 152.5 77 MONTROSE STATION ROAD
40% VOID TOWN OF CORTLANDT, NEW YORK
NO. OF UNITS PROVIDED = 4 UNITS
N.T.S. COMPACTED SUBGRADE
N.T.S. INFILTRATION BED INFILTRATION BED
CD-6.1
*THIS CALCULATION DID NOT TAKE INTO ACCOUNT
ORANGE CONSTRUCTION FENCE INFILTRATION TRENCH SHEET 8 OF 8
DRIVEWAY PAVING SECTION
N.T.S. ANY PERCOLATION INTO THE SOILS AND IS A
CONSERVATIVE DESIGN LOT 2 INFILTRATION BASIN OUTLET PIPING DIAGRAM N.T.S. LOT 3 INFILTRATION BASIN OUTLET PIPING DIAGRAM N.T.S.
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
ET
RE
ST
AIN
S TM
EA
CORTLANDT
CORTLANDT
SITE DEVELOPMENT PLAN
FOR CORTLANDT SELF STORAGE SITE
TOWN OF CORTLANDT
WESTCHESTER COUNTY, NEW YORK CORTLANDT CORTLANDT
GENERAL NOTES LOCATION MAP SCALE: 1" = 500'
1. PARCEL TAX MAP DESIGNATION: SECTION: 24.10, BLOCK: 1, LOT(S): 4
2. TOTAL AREA OF PROPERTY: 785,997 SQUARE FEET (18.044 ACRES).
3. SURVEY & TOPOGRAPHIC INFORMATION SHOW HEREON IS BASED ON A SURVEY PREPARED BY BADEY & WATSON
SURVEYING AND ENGINEERING, D.P.C. ENTITLED "SURVEY OF PROPERTY PREPARED FOR CORTLANDT SELF-STORAGE,
L.P..." DATED JULY 2, 2025.
4. PARCEL IS LOCATED IN THE TOWN OF CORTLANDT M-1 (LIGHT INDUSTRIAL) ZONING DISTRICT.
5. PARCEL IS LOCATED IN THE HUDSON RIVER BASIN.
LIST OF DRAWINGS www.digsafelynewyork.com
SHEET TITLE SHEET NUMBER TITLE ISSUE DATE LAST REVISED
SP-1.1 1 OF 2 AMENDED SITE PLAN JULY 17, 2026 -
SEE SHEET SP-1.2 (LARGER SCALE)
AMENDED SITE PLAN
SP-1.2 2 OF 2 JULY 17, 2026 - 60 0 30 60
(LARGER SCALE)
SCALE: 1" = 60 FT.
CONTRACTOR YARD
AREA = 6,430 SF APPLICANT
(EQUIPMENT, CONTAINER &
PROPOSED MATERIALS STORAGE)
SELF STORAGE BUILDING NO. 11
40' x 130' CORTLANDT SELF STORAGE, L.P.
4"Ø GRAVITY
PIPE C/O MARK GIORDANO
44 REGINA AVENUE
EXISTING SEWER
CORTLANDT MANOR, NEW YORK 10567
APPROXIMATE LOCATION OF EXISTING
BATHROOM
STRUCTURE & PUMPS
8"Ø GRAVITY SANITARY SEWER MAIN
THROUGH "PONDVIEW" DEVELOPMENT
· UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
EXIST 4"Ø GRAVITY PIPE
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
· COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED.
BATHROOM
REVISIONS
5
4
3
2
1
CONTRACTOR YARD SEE SHEET SP-1.2 (LARGER SCALE)
AREA = 3,570 SF # REASON DATE
(EQUIPMENT, CONTAINER &
MATERIALS STORAGE) MUNICIPAL TAX IDENTIFICATION:
EXISTING PARKING SECTION: 24.10
AREAS NOT PART OF
OUTSIDE CONTRACTOR BLOCK: 1
STORAGE AREAS
LOT: 4
SUBLOT: -
DRAWN BY: AD/JCA
CHECKED: JCA/PMB
PROJECT: GIORDANO
DATE: JULY 17, 2026
PATRICK M. BELL, P.E.
JOB #: 240101 LICENSE #087679
C N N
N N N
NAL N N N C N L N
BUILDING CHART (914) 736-3664
BUILDING NO. AREA (SF) CURRENT USE PROPOSED USE
1 5,200 SF SELF STORAGE SELF STORAGE 39 Arlo Lane
Cortlandt Manor, New York 10567
2 10,500 SF SELF STORAGE SELF STORAGE
3 5,000 SF SELF STORAGE SELF STORAGE
SITE DEVELOPMENT PLAN
4
5
7,250 SF
6,500 SF
SELF STORAGE
SELF STORAGE
SELF STORAGE
SELF STORAGE
SITE DEVELOPMENT PLAN
6 7,500 SF SELF STORAGE SELF STORAGE
SCALE: 1" = 60' SITE DEVELOPMENT PLAN
7 6,000 SF SELF STORAGE SELF STORAGE
FOR
CORTLANDT SELF-STORAGE, L.P.
8 4,000 SF SELF STORAGE SELF STORAGE
EQUIPMENT STORAGE OR
9 7,442 SF EQUIPMENT STORAGE
SELF STORAGE
LOCATION:
10 3,000 SF MECHANIC SHOP MECHANIC SHOP
REGINA AVENUE
11 5,200 SF N/A SELF STORAGE & OFFICE TOWN OF CORTLANDT, NEW YORK
TOTAL 67,592 SF
SHEET 1 OF 2 SP-1.1
Page 32
ET
RE
ST
IN
MA
ST
EA
CORTLANDT
CORTLANDT
ELEVATED PLATFORM AND
RAMP TO ASPHALT AREA
SITE
CORTLANDT CORTLANDT
LOCATION MAP SCALE: 1" = 700'
PROPOSED
SELF STORAGE BU
ILDING NO. 11
(40' X 130')
FF = 340.0'
EXIST SF = 350.0' www.digsafelynewyork.com
ING
PARK CONTRACTOR YARD
ING A
R EA AREA = 6,430 SF
(EQUIPMENT, CONTAINER
& MATERIALS STORAGE)
20 0 10 20
EXISTING SEWER FORCE
MAIN AND DRAINAGE PIPE SCALE: 1" = 20 FT.
TO BE LOCATED IN THE
FIELD AS NECESSARY APPLICANT
CORTLANDT SELF STORAGE, L.P.
C/O MARK GIORDANO
44 REGINA AVENUE
CORTLANDT MANOR, NEW YORK 10567
· UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS
UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS
ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF
ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE
DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
· COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED.
REVISIONS
5
4
3
2
1
# REASON DATE
MUNICIPAL TAX IDENTIFICATION:
SECTION: 24.10
BLOCK: 1
LOT: 4
SUBLOT: -
DRAWN BY: AD/JCA
CHECKED: JCA/PMB
PROJECT: GIORDANO
DATE: JULY 17, 2026
PATRICK M. BELL, P.E.
JOB #: 240101 LICENSE #087679
C N N
N N N
NAL N N N C N L N
(914) 736-3664
39 Arlo Lane
Cortlandt Manor, New York 10567
SITE DEVELOPMENT PLAN
SITE DEVELOPMENT PLAN SITE DEVELOPMENT PLAN
FOR
SCALE: 1" = 20' CORTLANDT SELF-STORAGE, L.P.
LOCATION:
REGINA AVENUE
TOWN OF CORTLANDT, NEW YORK
SHEET 2 OF 2 SP-1.2
Page 33
DOOR SCHEDULE
QTY CODE TYPE SIZE ROUGH OPENING (REF.) MANUF. DESCRIPTION COLOR
Page 34
Page 35
Short Environmental Assessment Form
Part 1 - Project Information
Instructions for Completing
Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the
application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on
information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as
thoroughly as possible based on current information.
Complete all items in Part 1. You may also provide any additional information you believe will be needed by or useful to the lead
agency; attach additional pages as necessary to supplement any item.
Part 1 – Project and Sponsor Information
Cortlandt Self-Storage LP
Name of Action or Project:
Cortlandt Self-Storage
Project Location (describe, and attach a location map):
44 Regina Avenue, Mohegan Lake, NY 10547 (Town of Cortlandt)
Brief Description of Proposed Action:
Amended Site Plan for the construction of a new storage building and creation of an outdoor contractor yard.
Name of Applicant or Sponsor: Telephone:
Cortlandt Self-Storage LP (Mark Giordano) E-Mail:
Address:
City/PO: State: Zip Code:
NY
1. Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, NO YES
administrative rule, or regulation?
If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that
✔
may be affected in the municipality and proceed to Part 2. If No, continue to question 2.
2. Does the proposed action require a permit, approval or funding from any other government Agency? NO YES
If Yes, list agency(s) name and permit or approval: Planning Board-Amended Sitte Plan
✔
3. a. Total acreage of the site of the proposed action? 18.044 acres
b. Total acreage to be physically disturbed? 0.1 acres
c. Total acreage (project site and any contiguous properties) owned
or controlled by the applicant or project sponsor? 18.044 acres
4. Check all land uses that occur on, are adjoining or near the proposed action:
Ƒ Urban Rural (non-agriculture) Industrial ■ Commercial ■ Residential (suburban)
■ Forest Agriculture Aquatic Other(Specify):
Parkland
Page 1 of 3 SEAF 2026
Page 36
5. Is the proposed action, NO YES N/A
a. A permitted use under the zoning regulations?
✔ ✔
b. Consistent with the adopted comprehensive plan? ✔ ✔
NO YES
6. Is the proposed action consistent with the predominant character of the existing built or natural landscape?
✔
7. Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? NO YES
If Yes, identify:
✔
NO YES
8. a. Will the proposed action result in a substantial increase in traffic above present levels?
✔
b. Are public transportation services available at or near the site of the proposed action?
✔
c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed
✔
action?
9. Does the proposed action meet or exceed the state energy code requirements? NO YES
If the proposed action will exceed requirements, describe design features and technologies:
Meets building code requirements
✔
10. Will the proposed action connect to an existing public/private water supply? NO YES
If No, describe method for providing potable water:
✔
11. Will the proposed action connect to existing wastewater utilities? NO YES
If No, describe method for providing wastewater treatment:
✔
12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district NO YES
which is listed on the National or State Register of Historic Places, or that has been determined by the
Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the ✔
State Register of Historic Places?
✔
b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for
archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory?
13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain NO YES
wetlands or other waterbodies regulated by a federal, state or local agency?
✔
b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody?
✔
If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres:
Page 2 of 3 SEAF 2026
Page 37
14. Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply:
Ƒ Shoreline Ƒ■ Forest Agricultural/grasslands Early mid-successional
■ Wetland Ƒ Urban Suburban
15. Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or NO YES
Federal government as threatened or endangered?
✔
16. Is the project site located in the 100-year or 500-year flood plain? NO YES
✔
NO YES
17. Will the proposed action create storm water discharge, either from point or non-point
sources?If Yes, ✔
a. Will storm water discharges flow to adjacent properties? ✔
b. Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? ✔
If Yes, briefly describe:
On-site stormwater management facility
18. Does the proposed action include construction or other activities that would result in the impoundment of water NO YES
or other liquids (e.g., retention pond, waste lagoon, dam)?
If Yes, explain the purpose and size of the impoundment:
✔
19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste NO YES
management facility?
If Yes, describe:
✔
20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or NO YES
completed) for hazardous waste?
If Yes, describe:
✔
NO YES
21. Is the project located within, or within ½ mile of, a disadvantaged community?
✔
If No, could impacts from the project affect a disadvantaged community? ✔
If Yes to either question in 21, answer the following question.
a. Identify the potential pollution impacts of the project, either direct or indirect, that may occur within the
disadvantaged community (e.g., wastewater discharges, air emissions, noise, odors, solid or hazardous waste
generation or management):
I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF
MY KNOWLEDGE
Applicant/sponsor/name: Cronin Engineering Date: June 24, 2026
Signature: Title: Project Engineer / Manager
Page 3 of 3 SEAF 2026
Page 38
EAF Mapper Summary Report Wednesday, June 24, 2026 10:19 AM
Disclaimer: The EAF Mapper is a screening tool intended to assist
project sponsors and reviewing agencies in preparing an environmental
assessment form (EAF). Not all questions asked in the EAF are
answered by the EAF Mapper. Additional information on any EAF
question can be obtained by consulting the EAF Workbooks. Although
the EAF Mapper provides the most up-to-date digital data available to
DEC, you may also need to contact local or other data sources to
confirm data provided by the Mapper or to obtain data not provided by
the Mapper.
Part 1 / Question 7 [Critical Environmental No
Area]
Part 1 / Question 12a [National or State No
Register of Historic Places or State Eligible
Sites]
Part 1 / Question 12b [Archeological Sites] Yes
Part 1 / Question 13a [Wetlands or Other Yes - Digital mapping information on local, New York State, and federal
Regulated Waterbodies] wetlands and waterbodies is known to be incomplete. Refer to the EAF
Workbook.
Part 1 / Question 15 [Threatened or No
Endangered Animal]
Part 1 / Question 16 [100 or 500 Year Yes
Floodplain]
Part 1 / Question 20 [Remediation Site] No
Part 1 / Question 21 [Disadvantaged No
Community]
Short Environmental Assessment Form - EAF Mapper Summary Report 1
Page 39
A
TE
O F NE W Y
NI F
ER W R
E
O
PRINTED
ST
RK
N
JE
AP
July 17, 2025
_________________________
BADEY & WATSON
OR
L IC
E X C E L S IO R
NS 5 0 3 8 9
Surveying & Engineering, D.P
_________________________
EY
E
ED V
L A ND SUR