TOWN OF CORTLANDT
PLANNING BOARD
Steven Kessler, Chairperson Town Supervisor
Thomas A. Bianchi, Vice-Chairperson Town Hall, 1 Heady Street Richard H. Becker, MD
Cortlandt Manor, NY 10567
Nora Hildinger Main #: 914-734-1080 Town Board
Kevin Kobasa Fax #: 914-788-0294 James F. Creighton
Peter McKinley Cristin Jacoby
Jeff Rothfeder Planning Staff email: Robert Mayes
Karen Timko chrisk@townofcortlandtny.gov Joyce C. White
Kellan Cantrell, Alternate
TO JOIN THE MEETING REMOTELY USE THE ZOOM LINK BELOW:
https://us02web.zoom.us/j/87570894468?pwd=fHAgcOppV75gIrAlDVKlMLfRyLcM6B.1
WORK SESSION…………………………………………………………..APRIL 7, 2026 6:00 PM
1. Discuss April 7, 2026 Regular Planning Board Meeting Agenda.
MEETING AGENDA………………………………………………….……... PLANNING BOARD
TOWN OF CORTLANDT
6:30 TUESDAY EVENING*
APRIL 7, 2026
1. PLEDGE TO THE FLAG
2. ROLL CALL
3. CHANGES TO THE AGENDA BY MAJORITY VOTE
4. ADOPTION OF THE MINUTES OF THE MEETING OF MARCH 3, 2026
5. CORRESPONDENCE
PB 16-99 a. Letter dated February 23, 2026 from John Bevegna, P.E. transmitting the 2025
Hollowbrook Golf Club Annual Monitoring Report.
PB 2023-5 b. Letter dated March 22, 2026 from David Steinmetz, Esq. requesting the 9th,
90-day time extension of Final Plat Approval for the Evergreen Subdivision
located at 2003 Crompond Road.
PB 2024-3 c. Letter dated March 22, 2026 from David Steinmetz, Esq. requesting the 1st, one-
year time extension of Amended Site Plan approval for the 2,400 sq. ft storage
building for Briga Enterprises & Bilotta Realty located at 2099 Albany Post Rd.
6. PUBLIC HEARING (ADJOURNED FROM PREVIOUS MEETING)
PB 2025-5 a. Public Hearing: Application of VS Construction Corp. for Site Plan approval
and for Tree, Wetland and Steep Slope permits for a proposed 96,850 sq. ft.
Assisted Living Facility located in the Medical Oriented District (MOD) at 2003
Crompond Road. Drawings revised November 20, 2025. (Public Hearing to be
adjourned to the May 5, 2026 meeting at the applicant’s request)
Page 2
7. PUBLIC HEARING (NEW)
PB 2026-4 a. Public Hearing: Application of Rafael Triana of High Q Electric for renewal of a
Specialty-Trade Contractor Special Permit for an electrical contractor located at
1 Dogwood Rd. Drawings dated April 5, 2022 (see prior PB’s 8-99 & 2020-18)
8. OLD BUSINESS
PB 2025-18 a. Application of 70 Roa Hook Realty LLC for Site Development Plan approval
to redevelop the site of the partially constructed Crystal Clean Carwash facility
to a proposed vehicle showroom and service facility for property located at 70
Roa Hook Rd. Drawings revised March 25, 2026 (see prior PB 13-16)
PB 2026-3 b. Application of VS Construction for Site Development Plan approval and for
Steep Slope and Tree Removal Permits for a proposed 9,600 sq. ft. commercial
building located on future parcel 3 within the Medical Oriented District for
property located at 2003 Crompond Rd. Drawings revised March 25, 2026.
PB 2024-8 c. Application of Mario & Wilson Alvarez, for Amended Site Plan approval and
for a Special Permit for a Specialty Trade Electrical Contractor for property
located at 1201 Oregon Rd. Drawings revised March 2026. (see prior PB 8-82)
PB 2025-16 d. Application of Steven J. Basini, R.A. for the property of Maric Family Limited
Partnership and Maric 1903 LLC for Amended Site Plan approval for the
conversion of a portion of the existing storage building into an autobody repair
garage to include parking layout and interior modifications for property located
at 23 Arlo Lane. Drawings revised March 23, 2026. (see prior PB 2020-19)
9. NEW BUSINESS
PB 2026-6 a. Application of Zarecki & Associates, LLC for the property of 2225 Crompond
Rd., LLC for Amended Site Plan Approval and a Special Permit for proposed
modifications to the existing gas station/convenience store and canopy located at
2225 Crompond Rd. (Route 202). Drawings dated March 18, 2026. (see prior
PB 18-07)
PB 2026-7 b. Application of New York-Presbyterian/Hudson Valley Hospital Center for
Amended Site Plan Approval for a proposed 1,877 sq. ft. addition to the existing
Medical Office Building for a Linear Accelerator for property located at 1980
Crompond Rd. Drawings dated March 12, 2026 (see prior PB’s 2019-9, 8-13,
23-04, 25-01, 23-01, 4-01)
10. ADJOURNMENT
Next Regular Meeting; TUESDAY, MAY 5, 2026 at 6:30* PM
Agenda information is also available at www.townofcortlandt.com
* Regular meeting will begin at the conclusion of the work session
2|Page
Page 3
February 23, 2026
Via E-mail:
Mr. Michael Preziosi, P.E.
Director, Department of Technical Services
Town of Cortlandt
One Heady Street
Cortlandt Manor, NY 10567
RE: Hollow Brook Golf Club
2025 Annual Monitoring Report
Dear Mr. Preziosi:
WSP is submitting the following 2025 Annual Monitoring Report as part of the Hollow Brook
Golf Club (HBGC) water quality monitoring program. The monitoring program has been in place since
2003 and is completed in accordance with the May 2002 Environmental Management Plan (EMP) and
several modifications adopted by the Town over the following years.
The current monitoring program includes groundwater, surface-water and storm water sampling.
Water samples are collected twice per year, in the summer and fall, from groundwater monitor wells GW-
1R and GW-4, and from downstream surface water location DS-1 in the Hollow Brook. In addition, storm
water samples are collected once per year from Hollow Brook location DS-1, if certain triggering
conditions are met. Course samples are analyzed for pesticides and several inorganic parameters which
are listed on Table 1. The EMP requires that all pesticides applied to the course in the previous 12 months
be included in the analyses.
SAMPLE DATES, LOCATIONS AND METHODOLOGIES
The 2025 sampling events for groundwater and surface-water were completed on August 5th and
November 13th. The groundwater and surface water samples were analyzed for the parameters listed on
Table 1. A Site Plan showing sample locations is included as Figure 1.
Pesticides were analyzed by Columbia Laboratories of Portland, Oregon. A complete list of
pesticides included in the analyses can be found attached to the lab reports in the Appendices. The
remaining parameters were analyzed by York Analytical Laboratories (York) of Stratford, Connecticut or
measured in the field.
The analytical results are compared to the New York State Surface Water and Groundwater
Standards per 6 NYCRR Part 703 or, alternative Response Thresholds per table 5-5 of the EMP (Table 1).
Any detected pesticides are evaluated for toxicological significance by comparison to 50-percent of
compound specific, EPA Health Advisory Levels (HALs) for human health effects in groundwater and,
10-percent of Lethal Concentration 50 (LC50s) for the protection of aquatic life in surface water.
WSP USA
500 Summit Lake Drive, Suite 450
Valhalla, NY 10595
T +1-914-747-1120
wsp.com
Page 4
A storm water sampling event is to be completed once per year, during the golf season, if certain
triggering conditions are met. The current storm event triggering conditions were adopted by the Town
Planning Board on October 1, 2024, in Resolution Number 11-24. Per the resolution, a triggering event
will be considered one which is forecast to produce 2.8 inches or more of precipitation within a 24-hour
period. This is considered a once-a-year storm event for Cortlandt Manor in accordance with the National
Oceanic and Atmospheric Administration, Point Precipitation Frequency Estimates. When sampling is
triggered in response to a forecasted triggering event, and a sample is collected, the storm event will be
deemed to have met the annual stormwater testing requirement, if the total rainfall is more than 1.5 inches
within a 24-hour period. This year a 2.8-inch or greater storm event was not forecasted in the area of the
course and a storm water sample was not collected.
SAMPLING RESULTS
The 2025 sampling results for groundwater and surface water are discussed below and presented
on Table 1. Historical results are included in previous Annual Monitoring Reports. The laboratory
analytical reports are included in Appendices I (August) and II (November). All pesticides used on the
course are registered for use in New York State and were reviewed for use at Hollow Brook by the
Town’s consulting agronomist, Dr. Martin Petrovic.
Summer Event: August 5, 2025
Groundwater
Laboratory results for this event show the detection of three pesticides in the groundwater sample
collected from well GW-1R, and one pesticide in the sample from well GW-4 (Table 1, Figure 1). The
detected pesticides included chlorantraniliprole, flutolanil and propiconazole and the detected
concentrations ranged from 0.78 to 4.75 ug/l (micrograms per liter). As shown on Table 1, all of the
detected pesticide concentrations were below applicable standards or response threshold criteria and as a
result, no further action was taken. All other parameters were either not detected or were below applicable
standards, guidance or response threshold criteria (Table 1).
Surface Water
As shown on Table 1, there were no pesticide detections in the downstream Hollow Brook surface
water sample DS-1. All other parameters were either not detected or met applicable standards, guidance
or response threshold criteria (Table 1).
Fall Event: November 13, 2025
Groundwater
Laboratory results for November show the detection of two pesticides in the sample from well
GW-1R, flutolanil and propiconazole, both of which were also detected in the August sample from this
well. The detected concentrations were 5.11 and 1.03 ug/l respectively and were below the applicable
standards or response threshold criteria. However relative to August, the concentration of flutolanil
increased from 0.92 ug/l to 5.11 ug/l while the concentration of propiconazole decreased (Table 1).
Pesticides were not detected in the sample from GW-4. All other parameters were either not detected or
met applicable standards, guidance or response threshold criteria.
Page 2
Page 5
Surface Water
As shown on Table 1, there were no pesticide detections in the downstream Hollow Brook
surface water sample DS-1. All other parameters were either not detected, or met applicable standards,
guidance or response threshold criteria.
DISCUSSION AND RESPONSES
The management response to pesticide detections in groundwater or surface-water samples is
described in the EMP. If certain pesticides (specifically listed in the EMP) are detected twice in the same
year, the indicated response is to suspend their use. However, based on historical data and because new
pesticides are not specifically addressed in the EMP, the Town and HBGC have agreed that pesticides
that are repeatedly detected in groundwater samples could continue to be used on the course under the
following conditions:
- The pesticide detection is below the toxicologically significant criteria. For groundwater this is 50
percent of the respective EPA Health Advisory Levels (HALs).
- The pesticide is not detected in the Hollow Brook; and,
- Use of the pesticide would be restricted to spot applications until it is no longer detectable.
Three pesticides were detected in groundwater samples this year, chlorantraniliprole, flutolanil
and propiconazole. All other analyzed parameters were either not detected or met applicable standards,
guidance or response threshold criteria, showing no impact to water quality.
All of the detected pesticide concentrations were below their respective human health-based
toxicological criteria and there were no detections in the Hollow Brook. However, flutolanil was detected
in a sample from GW-1R during the November 2025 event meaning it has now been detected in the same
well during three consecutive sampling events. Propiconazole was detected twice this year in the same
well.
Based on the noted detections, the following responses are required in accordance with the
protocol as described above.
Chlorantraniliprole: No Restrictions.
Chlorantraniliprole was detected this year in August and was not detected in November or during
2025. The detected concentration was below the human health-based toxicological criteria (Table 1) and
was not detected in the Hollow Brook. In accordance with the protocol, no action is required.
Propiconazole: Restricted to Spot Treatment
Propiconazole was detected twice this year in the same well, GW-1R. The detected
concentrations were below the human health-based toxicological criteria and showed a decrease between
the August and November sampling events. In accordance with the protocol, propiconazole use has to be
restricted to spot applications until it is no longer detectable in GW-1R. Alternatively, propiconazole can
be substituted with another product approved for use on the course if available.
Page 3
Page 6
Flutolanil: Restricted to Spot Treatment
Flutolanil has been detected in three consecutive samples from the same well and in August was
detected in both wells sampled as part of the monitoring program. The detected concentrations were
below the human health-based toxicological criteria. However, because it was detected twice in the same
year, its use has to be restricted to spot applications until it is no longer detectable in groundwater.
Alternatively, flutolanil can be substituted with another product approved for use on the course if
available.
In addition to the above, it would be prudent for the course to review its application procedures,
particularly with respect to flutolanil in the area of the 6th Green, to try and mitigate these detections. We
recommend the Town request confirmation from the course that the required restrictions will be
implemented for the 2026 season as well as any other action they may take to mitigate these detections.
Kind regards,
WSP USA
John Benvegna, P.G.
Vice President
cc: Chris Kehoe, AICP, T/Cortlandt
David Rambo, C/Peekskill Water Dept.
Eugene Peterson, Hollow Brook
f:\reports\town of cortlandt\hollowbrook\annual reports\2021 annual report\hollow brook golf club 2021 annual monitoring report.docx
Page 4
Page 7
Chris Kehoe
From: Eugene Peterson < com>
Sent: Tuesday, March 24, 2026 12:52 PM
To: Chris Kehoe
Cc: Michael Preziosi; Catherine Brosnan; Heather LaVarnway; Benvegna, John
Subject: RE: Hollow Brook Golf Club 2025 Monitoring Report
Chris,
Thank you for your note.
This letter serves as confirmation that Hollow Brook Golf Club will implement and adhere to the required
restrictions outlined in the report for the 2026 season, as referenced in the final paragraph on page 4.
We appreciate your guidance on this matter and will ensure full compliance. Based on this confirmation, I
understand attendance at the April 7th Planning Board meeting will not be necessary; however, please let me
know if anything further is required.
Sincerely,
Eugene Peterson
Hollow Brook Golf Club
From: Chris Kehoe < >
Sent: Monday, March 23, 2026 3:28 PM
To: Eugene Peterson < >
Cc: Michael Preziosi < >; Catherine Brosnan < >;
Heather LaVarnway < >; Benvegna, John >
Subject: FW: Hollow Brook Golf Club 2025 Monitoring Report
Eugene,
I know you received this report directly from John. As per the last paragraph on page 4 please provide me conforma on,
via le er, that you plan on implemen ng the required restric ons for the 2026 season. The Planning Board mee ng is
April 7th. Assuming I get the confirma on from you I don’t see a need for you to a end the mee ng.
Chris Kehoe, AICP
Town of Cortlandt
Director of Planning & Community Development
1 Heady Street
Cortlandt Manor, New York 10567
914-734-1081
1
Page 8
https://wherelifeworkscortlandt.com/
From: Benvegna, John < >
Sent: Monday, February 23, 2026 2:32 PM
To: Michael Preziosi
Cc: 'Eugene Peterson' ( )< ; David Rambo
( ) >; Chris Kehoe < >
Subject: Hollow Brook Golf Club 2025 Monitoring Report
CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the
sender and know the content is safe.
Hi Michael,
Attached for your use is our 2025 groundwater and surface water monitoring report for the Hollow Brook Golf
Club.
Please let me know if you have any questions.
Thank you
John Benvegna, PG (NY)
Vice President, Hydrogeologist
Earth & Environment Downstate NY
Direct: 914 461-2961
Office 914 747-1120
WSP
500 Summit Lake Drive, Ste 450
Valhalla, NY 10595
wsp.com
NOTICE: This communication and any attachments ("this message") may contain information which is privileged, confidential, proprietary or otherwise subject to
restricted disclosure under applicable law. This message is for the sole use of the intended recipient(s). Any unauthorized use, disclosure, viewing, copying,
alteration, dissemination or distribution of, or reliance on, this message is strictly prohibited. If you have received this message in error, or you are not an
authorized or intended recipient, please notify the sender immediately by replying to this message, delete this message and all copies from your e- mail system and
destroy any printed copies.
-LAEmHhHzdJzBlTWfa4Hgs7pbKl
2
Page 9
Brian T. Sinsabaugh
bsinsabaugh@zarin-steinmetz.com
March 22, 2026
Via OpenGov (PBCK23-13)
Hon. Steven Kessler
Chairman of the Town of Cortlandt Planning Board
and Members of the Board
1 Heady Street
Cortlandt Manor, New York 10567
Re: VS Construction Corp. (PB2023-5)
2003 Crompond Road (Section 33.12 Block 2 Lots 1, 7 & 8)
Dear Chairman Kessler and Members of the Planning Board:
As you all know, our Firm represents VS Construction Corp. (the “Applicant” or “VS
Construction”), owner of the above-referenced Property in connection with the Town’s Medical
Oriented District (“MOD”).
We received Final Subdivision Plat approval from your Board in November 2023 (PB
Resolution No. 15-23), and an extension of that approval was most recently granted by your Board
in January 2026 (PB Resolution No. 1-26, attached). As that extension expires April 30, 2026, we
hereby request a further extension of that approval. Our clients and engineering team are
continuing to work with Town staff to finalize the utilities, including storm water and sewer design,
and related details, such that the County can indeed sign off on the Plat Map. While this process
is ongoing and not yet complete, we do expect it to be done shortly.
We look forward to appearing before your Board at your April 7th meeting. In the
meantime, please do not hesitate to contact us with any questions
Respectfully,
ZARIN & STEINMETZ LLP
By:
David S. Steinmetz
Brian T. Sinsabaugh
Phone: (914) 682-7800 www.zarin-steinmetz.com 81 Main Street, Suite 415
Direct: (914) 220-9806 White Plains, New York 10601
Page 10
Town of Cortlandt Planning Board
VS Construction Corp. (PB2023-5)
March 22, 2026 | Page 2
Enclosure: PB Res. No. 1-26
PB Res. No. 15-23
Copy to:
Chris Kehoe, AICP, Planning Director
Thomas Wood, Esq., Town Attorney
Michael Cunningham, Esq., Deputy Town Attorney
VS Construction Corp.
DTS Provident Design Engineering LLP
4920-9865-1443, v. 1
Page 11
TOWN OF CORTLANDT RESOLUTION NO. 1-26
PLANNING BOARD
PB 2023-5
WHEREAS, the application of VS Construction Corp. for Preliminary and Final Plat approval
pursuant to Sections 276 and 277 of the New York State Town Law and Chapter 265 (Subdivision
Regulations) of the Town of Cortlandt Code for a proposed 2-lot major subdivision of an approximately
28.6-acre parcel of property and for a Wetland Permit pursuant to Chapter 179, a Tree Removal
pursuant to Chapter 283 and a Steep Slope Permit pursuant to Chapter 259 of the Town of Cortlandt
Code only for the proposed .958 acre road parcel as shown on a drawing entitled “Subdivision of
Property prepared for V.S. Construction Corp.” prepared by Daniel Merritts, P.L.S. latest revision dated
October 23, 2023 and as shown on an 11 page set of improvement drawings entitled “2003 Crompond
Road, Subdivision Application” prepared by Gerhard Schwalbe, P.E. latest revision dated November 1,
2023 was approved on November 8 , 2023 by PB Res. 15-23, and
WHEREAS, the subject properties are located on the south side of Crompond Road (Route 202) east of
Lafayette Avenue and west of Tamarack Drive, are zoned MOD, Medical Oriented District and
designated on the Town of Cortlandt Tax Maps as Section 33.12, Block 2, Lots 1, 7 & 8, and
WHEREAS, by Resolutions 4-24, 7-24, 12-24, 2-25, 10-25, 15-25 & 19-25 the Planning Board
previously granted seven, 90-day time extensions of Final Plat approval, and
WHEREAS, by a letter dated December 23, 2025 David Steinmetz, Esq. requested the 8th, 90-day time
extension of Final Plat approval for the subject application in order to continue to meet the conditions of
said approval.
NOW THEREFORE BE IT RESOLVED that the request of David Steinmetz, Esq. for the 8th,
1
Page 12
90-day time extension of Final Plat approval is hereby APPROVED, said extension to expire on April
30, 2026.
Chairman Kessler Aye
Mr. Bianchi Aye
Ms. Hildinger Absent
Mr. Kobasa Aye
Mr. McKinley Aye
Mr. Rothfeder Absent
Ms. Timko, Alternate Aye
Mr. Cantrell, Alternate Absent
Motion Carried 5-0
Adopted: January 6, 2026
Cortlandt Manor, New York
Chris Kehoe
Director, Dept. of Planning and Community Development
Clerk to the Planning Board
2
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
DRAFT
TOWN OF CORTLANDT RESOLUTION NO. 7-26
PLANNING BOARD
PB 2023-5
WHEREAS, the application of VS Construction Corp. for Preliminary and Final Plat approval
pursuant to Sections 276 and 277 of the New York State Town Law and Chapter 265 (Subdivision
Regulations) of the Town of Cortlandt Code for a proposed 2-lot major subdivision of an approximately
28.6-acre parcel of property and for a Wetland Permit pursuant to Chapter 179, a Tree Removal
pursuant to Chapter 283 and a Steep Slope Permit pursuant to Chapter 259 of the Town of Cortlandt
Code only for the proposed .958 acre road parcel as shown on a drawing entitled “Subdivision of
Property prepared for V.S. Construction Corp.” prepared by Daniel Merritts, P.L.S. latest revision dated
October 23, 2023 and as shown on an 11 page set of improvement drawings entitled “2003 Crompond
Road, Subdivision Application” prepared by Gerhard Schwalbe, P.E. latest revision dated November 1,
2023 was approved on November 8 , 2023 by PB Res. 15-23, and
WHEREAS, the subject properties are located on the south side of Crompond Road (Route 202) east of
Lafayette Avenue and west of Tamarack Drive, are zoned MOD, Medical Oriented District and
designated on the Town of Cortlandt Tax Maps as Section 33.12, Block 2, Lots 1, 7 & 8, and
WHEREAS, by Resolutions 4-24, 7-24, 12-24, 2-25, 10-25, 15-25, 19-25 & 1-26 the Planning Board
previously granted eight, 90-day time extensions of Final Plat approval, and
WHEREAS, by a letter dated March 22, 2026 David Steinmetz, Esq. requested the 9th, 90-day time
extension of Final Plat approval for the subject application in order to continue to meet the conditions of
said approval.
NOW THEREFORE BE IT RESOLVED that the request of David Steinmetz, Esq. for the 9th,
1
Page 25
90-day time extension of Final Plat approval is hereby APPROVED, said extension to expire on July
29, 2026.
TO BE CONSIDERED FOR ADOPTION: APRIL 7, 2026
2
Page 26
Brian T. Sinsabaugh
bsinsabaugh@zarin-steinmetz.com
March 22, 2026
Via OpenGov
Hon. Steven Kessler
Chairman of the Town of Cortlandt Planning Board
and Members of the Board
1 Heady Street
Cortlandt Manor, New York 10567
Re: Briga Enterprises Inc. & Bilotta Realty of Westchester Inc. (PB2024-8)
2099 Albany Post Road (Section 55.09 Block 1 Lots 3)
Dear Chairman Kessler and Members of the Planning Board:
As you all know, our Firm represents Briga Enterprises Inc. and Bilotta Realty of
Westchester Inc. (the “Applicant”), owners of the above-referenced Property, in connection with
their application for amended site plan approval.
We received Amended Site Plan approval from your Board in April 2025 (PB Resolution
No. 8-25, attached). As that extension is scheduled to expire April 1, 2026, we hereby request an
extension of that approval. Our clients and engineering team are continuing to work with Town
staff to finalize conditions of this approval, including associated permits. While this process is
ongoing and not yet complete, we do expect it to be done shortly.
We look forward to appearing before your Board at your April 7th meeting. In the
meantime, please do not hesitate to contact us with any questions
Respectfully,
ZARIN & STEINMETZ LLP
By:
David S. Steinmetz
Brian T. Sinsabaugh
Phone: (914) 682-7800 www.zarin-steinmetz.com 81 Main Street, Suite 415
Direct: (914) 220-9806 White Plains, New York 10601
Page 27
Town of Cortlandt Planning Board
Briga Enterprises Inc. / Bilotta Realty of Westchester Inc (PB 2024-3)
March 22, 2026 | Page 2
Enclosure: PB Res. No. 8-25
Copy to:
Chris Kehoe, AICP, Planning Director
Thomas Wood, Esq., Town Attorney
Michael Cunningham, Esq., Deputy Town Attorney
Briga Enterprises Inc.
Bilotta Realty of Westchester Inc.
4936-1796-3930, v. 1
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
DRAFT
TOWN OF CORTLANDT RESOLUTION NO. 8-26
PLANNING BOARD
PB 2024-3
WHEREAS, the application submitted by Briga Enterprises Inc. & Bilotta Realty of Westchester
Inc. for Amended Site Plan approval for a 2,400 sq. ft. storage building as shown on a 3-page set of
drawings entitled “Dakota Supply Corp.- Tenant Change in Existing Building” dated February 18,
2025 prepared by Steven J. Basini, R.A. and on drawings entitled “Site Plan for 2099 Albany Post
Rd.-Proposed 40’ by 60’ Metal Storage Building” latest revision dated February 28, 2025 and
“Foundation Plan” dated December 18, 2023 both prepared by George Mottarella, P.E., was
approved by PB. Res. 8-25 adopted on April 1, 2025, and
WHEREAS, the entire subject property is approximately 9.7 acres is located at 2099 Albany Post
Rd. and is split-zoned with the front portion to a depth of approximately 200’ zoned HC/9A and the
remainder of the site zoned M-1, Light Industrial, and is designated on the Town of Cortlandt Tax
Maps as Section 55.09, Block 1, Lot 3, and
WHEREAS, by a letter dated March 22, 2026 David Steinmetz, Esq. requested the first, one-year
time extension of Conditional Site Development Plan approval in order for the applicant to continue
to meet thee conditions of approval.
NOW THEREFORE BE IT RESOLVED that the request of David Steinmetz, Esq. for the first
one-year time extension of Conditional Site Development Plan approval is hereby approved, said
extension to expire of April 1, 2027.
TO BE CONSIDERED FOR ADOPTION: APRIL 7, 2026
Page 35
Brad K. Schwartz
bschwartz@zarin-steinmetz.com
March 25, 2026
By E-mail and Hand Delivery
Hon. Steven Kessler
Chairman of the Town of Cortlandt Planning Board
and Members of the Board
1 Heady Street
Cortlandt Manor, New York 10567
Re: 70 Roa Hook Realty LLC – Application for Site Plan Approval
Dear Chairman Kessler and Members of the Town Board:
We make this submission on behalf of 70 Roa Hook Realty LLC in advance of the April 7
meeting. Our client respectfully requests that the Board declare Lead Agency status under SEQRA
and schedule a Public Hearing for the May meeting.
John Canning will be in attendance on April 7 to present his findings that the proposed
parts sales and service/repair of Peterbilt trucks would generate much less traffic than the
previously approved car wash. While this proposal would result in more on-site improvements as
compared to the car wash to accommodate our client’s operations, it would, on balance, be more
beneficial to Roa Hook Road and the nearby community by reducing any potential off-site impacts.
Enclosed please find an updated set of site plan drawings reflecting comments raised by
the Planning Board, Planning Department, and DOTS. Also enclosed are Memoranda responding
to the written comments issued by the Planning Department and DOTS. While we believe we have
addressed all Town comments, we acknowledge that our discussions with DOH and DOT are
ongoing, and we will continue to keep the Planning Board and Staff updated on our progress.
Thank you for the Board’s continued attention.
Respectfully submitted,
ZARIN & STEINMETZ LLP
By: ____Brad Schwartz ___
Brad Schwartz
Phone: (914) 682-7800 www.zarin-steinmetz.com 81 Main Street, Suite 415
Direct: (914) 220-9793 White Plains, New York 10601
Page 36
Town of Cortlandt Planning Board
March 25, 2026 | Page 2
cc: Michael J. Cunningham, Esq.
Chris Kehoe, AICP
Heather Lavarnway, CNU-A, AICP
Michael Preziosi, P.E.
Catherine E. Brosnan, P.E. ENVSP
John Schembari – Director of Code Enforcement
Chris Lapine, PE
Leal Peterbilt Team
Page 37
MEMORANDUM
Town of Cortlandt Planning Board
To:
Attn: Mr Chris Kehoe, AICP
From:
Kimley-Horn Engineering and Landscape Architecture of New York
P.C. (John Canning, P.E)
and
John J. Gilchrist Architect PC
Date: March 25, 2026
Response to Planning Comments from Review Memorandum on Leal
Subject:
Peterbilt Development at 70 Roa Hook Road
Kimley-Horn Engineering and Landscape Architecture of New York P.C. and John J.
Gilchrist Architect PC have reviewed the comments made by the Town of Cortlandt
Planning Department, dated February 18, 2026, regarding PB Case 2025-18, the
proposed Leal Peterbilt of Westchester development at 70 Roa Hook Road,
Cortlandt Manor, NY 10567.
The following describes the applicant’s responses to the Planning Department’s
comments:
Comment 1: Clarification about what types/sizes of trucks are expected to be
on-site
Response: The vast majority of vehicles accessing the site will be Single-Unit (i.e.
no trailers) vehicles, 24 feet or less in length. They may include dump trucks,
concrete mixer trucks, garbage trucks, oil and fuel trucks, roll off trucks, box trucks
(including for delivery of parts), conventional sleeper tractors, and day cab tractors.
None of these vehicles will be longer than 30 feet. To provide conservative analysis
and to be able to accommodate a larger vehicle, if it was ever needed, the site has
been designed to accommodate 30.65-foot-long tractor cabs.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 38
Page 2
Comment 2: Clarification about whether any trucks will be parked/stored
outside of the building.
Response: There will be no materials or non-vehicular equipment stored outside of
the building. Employee’s personal vehicles and some trucks are expected to be
parked on the property. Truck repair service will be by appointment only. There
may be instances where a truck is scheduled to be repaired/serviced and, when it
arrives, for whatever reason, work has not been completed in the bay it was
scheduled to be repaired in. Further, when the repair/service work is completed, the
truck will be removed from the service bay to await pick up. In both of these
instances, the trucks will be temporarily parked on site. Spaces to park 4, 30-foot
trucks have been provided along the back of the site.
In addition, the operator may sometime accept a truck for repair and sale. In such
instances, the repaired (and cleaned-up) truck would be temporarily parked and
displayed in front of the repair shop so that potential customers can see it from the
street.
Comment 3: An updated Zoning Schedule should be provided on the plans to
include Minimum Landscape Coverage (existing and proposed)
Response: An updated Zoning Schedule has been provided on Drawing 1 of the
plans. It includes Minimum Landscape Coverage (existing and proposed). The
proposed landscape coverage is the same as the most-recently approved landscape
coverage for the car wash (11.3% - this was by a variance, which runs with the
land).
Comment 4: A truck circulation plans.
Response: Truck circulation plans showing how the expected oversized vehicles
will maneuver through the site, including the largest anticipated type of Peterbilt
truck, garbage truck, delivery truck and the largest anticipated fire apparatus that
would service the site, have been provided. Details of the specific vehicle specs
used for the circulation plan are included on each plan.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 39
Page 3
Comment 5: Provide a lighting photometric plan.
Response: A lighting photometric plan and fixture specifications in conformance
with the Town’s Outdoor Lighting Standards (see §307-12.3) is nearing completion.
Comment 6: Provide a parking table clearly showing the required and
proposed number of spaces.
Response: A parking table clearly showing the required and proposed number of
spaces has been provided on Drawing 1 of the plans (the Town Code for AWE-
zoned property suggests limiting the number of parking spaces to what is actually
required which is what is proposed). A breakdown of the building square footage to
be used for parts storage and truck repair activities is shown on Drawing 4.
Comment 7: Provide a complete planting schedule.
Response: A complete planting schedule, including the quantity of each type of
plant material proposed, with the inclusion of native/indigenous plant materials
where possible, has been provided on Drawing 3 of the plans.
Comment 8: Provide a signage schedule.
Response: A free-standing sign detail is provided on Drawing 1 and a building-
mounted sign detail is provided on Drawing 5 of the plans. The proposed wall
mounted sign on the south elevation is shown on Drawing 5 of the plans.
Comment 9: Notarized authorization from Camp Smith.
Response: The Applicant is working with the NYSDOT to determine if any
restoration work is required on the adjacent property owned by Camp Smith, or if the
drainage that was already constructed is acceptable. If restoration work is needed,
the applicant shall supply notarized authorization from Camp Smith granting the
applicant permission to access their property to perform the work.
Comment 10: The Engineering Department will provide a separate review
memo covering engineering issues.
Response: Comment noted. A separate Response Memo is enclosed addressing
those comments.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 40
Page 4
Comment 11: There will be reduced landscaping in front of the building, trucks
will access some of the repair bays from the south side of the building, and
the parcel is proposed to be almost entirely covered in impervious surfaces.
Are the size of the building additions, the number of service bays, and the
altered direction of access to the bays appropriate for the subject 0.64-acre
parcel?
Response: The site layout has been reconfigured so that the bays are accessed
from the same locations as was approved. The circulation has been modified so
that there is almost no reduction in landscaping in front of the building (there will now
be no front yard parking area close to Route 9). The impervious coverage is now
the same as was approved for the car wash.
Therefore, it is the Applicant’s opinion that the size of the building additions, the
number of service bays, and the direction of access to the bays is appropriate for the
subject 0.64-acre parcel (particularly because there will be a significant reduction in
traffic and parking activity for Leal Peterbilt on the site, as compared to the prior car
wash operation, which will also significantly reduce the potential for any impacts
along Roa Hook Road).
Comment 12: Evaluate Truck Circulation Pinch Points
Response: The truck circulation plan has been revised to ensure that all trucks
visiting the site will be able to circulate adequately. The vast majority of vehicles
accessing the site will be Single-Unit (i.e. no trailers) vehicles, 24 feet or less in
length. To provide conservative analysis, the site has been designed to
accommodate vehicles as large as 30.65-foot-long tractor cabs and outdoor parking
has been appropriately accounted for.
Comment 13: Outdoor Truck Parking
Response: The proposed parking has been shown on the site plan, and has been
taken into consideration in the truck circulation plan. As previously discussed, truck
parking will be temporary and will not interfere with the site’s operation. Any truck
display parking will occur entirely on-site and will not interfere with truck circulation.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 41
Page 5
Comment 14: Truck Delivery
Response: Truck repair and service will be by reservation only. All trucks will be
required to be driven to and from the site. The Operator will not accept trucks towed
to or from the site. Truck owners requesting repair services for a non-operable truck
will be directed to one of the operator’s other facilities.
Comment 15: Truck Delivery
Response: The five parking spaces shown on the easterly property line have been
designed so that they will not result in encroachment onto the adjacent parcel. The
spaces they are nine feet wide and will mostly be used by employees or other
single-occupant-vehicles, where the driver will exit the vehicle on the opposite side
of the property line. No buffer will be necessary.
Comment 16: Driveway Configuration
Response: The site access has been designed to better accommodate truck access
and the truck circulation plans demonstrate that the design is sufficient for this use
involving oversized, heavy-duty trucks regularly accessing the site.
Comment 17: Dumpster Area
Response: Dumpsters and fencing are shown in the “dumpster and recycling area”
labeled in the north corner of the plan. Sufficiently-sized dumpsters, which will be
rolled out for emptying, are shown on either side of the bollards and the dumpsters
will be rolled out for emptying in a safe manner by a garbage truck. The garbage
truck movements are shown on the circulation plan.
Comment 18: Accessible Parking Space
Response: A single accessible space is proposed on the east side of the property.
Comment 18: Off-site Landscaping
Response: The Landscaping Plan, on Drawing 3 of the plans, has been modified to
clearly distinguish between plant materials located off-site, on the surrounding Camp
Smith property (which were part of mitigation associated with the previously
approved car wash, for trees that were removed from the adjacent Camp Smith
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 42
Page 6
property without authorization), from on-site landscaping associated with the current
proposal.
Comment 19: On-site Landscaping
Response: The plans show how the landscaping requirement in §307-96.1-E (8) is
satisfied, including but not limited to the required front yard lawn/landscaping and
required plantings adjacent to the building.
Comment 20: On-site Landscaping
Response: The plans show how the landscaping requirement in §307-96.1-E (8) is
satisfied, including but not limited to the required front yard lawn/landscaping and
required plantings adjacent to the building.
Comment 21: Impervious Coverage
Response: The applicant has successfully increased the amount of landscaping on
the site, reducing the impervious coverage to the same amount as the previously
approved car wash plan.
Comment 22: Referral to the Conservation Advisory Council
Response: The plans, including the Landscaping Plan, will be referred to the
Conservation Advisory Council for their review and comment as requested.
Landscaping is per the approved car wash plan with additional arborvitae along the
east side of the building, subject to review by the Conservation Advisory Council.
Comment 23: Rear Storage
Response: The rear storage bays will be utilized by the operator, primarily for pre or
post business hours deliveries.
Comment 24: Access to the bays at the west of the Site
Response: The bays at the western portion of the larger building addition will have
garage doors at the front only. The rear of these bays will be used for customary
tools, equipment and materials storage.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 43
Page 7
Comment 25: Color Renderings
Response: The applicant has provided color renderings of the proposed buildings
on Drawing 5 to clearly illustrate the proposed design and materials.
Comment 26: Fire Protection
Response: The subject drawings will be referred to the Continental Village Fire
District for their review and comment, as directed.
Comment 26: The subject application is classified as an unlisted action
pursuant to the New York State Environmental Quality Review Regulations,
the applicant submitted Part One of the Short Environmental Assessment
Form and the Planning Board has declared their Intent to be Lead Agent (with
a coordinated review and referral to interested and involved agencies).
Response: Comment Noted
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 44
MEMORANDUM
To: Town of Cortlandt Planning Board
From:
Kimley-Horn Engineering and Landscape Architecture of New York
P.C. (John Canning, P.E)
and
John J. Gilchrist Architect PC
Date: March 25, 2026
Response to Engineering Comments from Review Memorandum on
Subject:
Leal Peterbilt Development at 70 Roa Hook Road
Kimley-Horn Engineering and Landscape Architecture of New York P.C. and John J.
Gilchrist Architect PC have reviewed the engineering comments made by the Town
of Cortlandt Department of Technical Services, dated February 19, 2026, regarding
PB Case 2025-18, the proposed Leal Peterbilt of Westchester development at 70
Roa Hook Road, Cortlandt Manor, NY 10567.
This following describes the response to DOTS comments:
Comment 1a (i): The Applicant should provide an update on the completed
works for the onsite wastewater treatment system and well.
Response: The wastewater treatment system and well were installed but final
closeout of the WCDOH permit never occurred. As detailed below, the Applicant has
re-engaged with WCDOH relative to the wastewater treatment system and the well.
Comment 1a (ii): The Applicant shall inform the Town Board as to whether the
WCDOH plans to issue a letter of no objection, allowing the renewal of their
open permit or require a new sanitary design.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 45
Page 2
Response: The Applicant has reengaged with WCDOH relative to the wastewater
treatment system and the well. The DOH has indicated that a new permit will be
required. Once the Planning Board provides its feedback on the latest Site Plan
layout that responds to Town planning and engineering comments, the necessary
paperwork and plans will be submitted to the DOH.
Comment 1a (iii): The Applicant shall verify if the pre-existing water supply
well was abandoned in accordance with WCDOH rules and regulations and if
the proposed well as part of the car wash application was completed.
Response: As stated above, the Applicant has re-engaged with WCDOH relative to
the wastewater treatment system and the well. The status of the well will be
reviewed by DOH as part of this permit application. We will keep the Town updated
on our submissions and progress with DOH.
Comment 1b: The Applicant should provide correspondence by DMNA
outlining Camp Smith restoration requirements to be incorporated into a
revised plan set.
Response: The Applicant has met at the site with representatives of Camp Smith.
As discussed below, details of restoration requirements will be subject to the
outcome of discussions with the NYSDOT.
Comment 1c (i): Include NYSDOT right of way on drawings.
Response: The NYSDOT right of way has been included on the revised drawings.
Comment 1c (ii): It is recommended that the Planning Board refer the
proposed site application to the NYSDOT Region 8 Permit Engineer for
comment.
Response: The Applicant has been in contact with NYSDOT. A new permit will be
required for the prosed driveway changes and to address issues unresolved from
the last permit that was issued, including restoration, as may be required, on Camp
Smith property.
Comment 1c (iii): It is recommended that the current Applicant provide
correspondence by NYSDOT outlining restoration requirements to be
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 46
Page 3
incorporated into a revised plan set or written no objection that the drainage
as constructed may remain as is.
Response: The Applicant will provide correspondence by NYSDOT outlining
restoration requirements to be incorporated into a revised plan set or written no
objection that the drainage as constructed may remain as is, depending on the
outcome of the pending permit review discussed above.
Comment 2: The 2025 Application shall be revised to reflect the following, as
required:
a. All existing offsite drainage improvements constructed on Camp
Smith’s Property other than a 24” corrugated plastic pipe. Existing topography
(2-ft intervals) and spot elevations.
b. Existing building first floor elevation.
c. Rims and inverts of existing drainage.
d. Top and bottom wall elevations for the low retaining wall constructed
along the western and northern property lines.
e. Flood plain data, revised to reflect the current effective FEMA FIRM with
the preliminary FIRM evaluated and designed to the more stringent standard.
f. The referenced a 2017 property survey.
Response: The Site Plan reflects the above, as required:
Comment 3: A revised dimensional bulk zoning table was not provided, in
order to evaluate zoning compliance.
Response: A dimensional bulk zone table is on page 1 of the plans.
Comment 4a: The proposed building addition demonstrate the four (4)
proposed service bays to have an overhead garage door more than 12’-8”.
This calls into question whether larger vehicles are anticipated to be brought
to the site.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 47
Page 4
Response: Larger vehicles are anticipated to be brought to the site but only as
permitted by standard vehicle and traffic flow. See discussion below regarding
vehicle size.
Comment 4b: It appears a mezzanine is called out above this portion of the
building. It is recommended that the Applicant clarifies if this is a 2nd story or
an extended mezzanine.
Response: It is a mezzanine and the size has been reduced, as compared to what
was approved.
Comment 5a: The proposed site developments require further refinement
relative to the location of onsite wastewater treatment system and WCDOH
approval log.
Response: Location of the onsite wastewater treatment system and WCDOH
approval log will be included following discussions with WCDOH, as detailed above.
The Septic Design Plan in the submission plan set is information only. This is still
subject to DOH approval.
Comment 5b: The proposed site developments require further refinement
relative to the location, size, rims and inverts of all existing storm water bet
management practices and oil water separator.
Response: Location size, rims and inverts of all existing storm water bet
management practices and oil water separator have been noted on the plans,
including drainage size and material type.
Comment 5c: The proposed site developments require further refinement
relative to which manholes are to remain and which are to be removed.
Response: The plans note which manholes are to remain and which are to be
removed (see Drawing 2, Site Plan.
Comment 5d: The proposed site developments require further refinement
relative to waste oil/fuel tanks, above-ground storage tanks, utilities, sanitary
and miscellaneous equipment.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 48
Page 5
Response: The plans show and note waste oil/fuel tanks, above-ground storage
tanks, utilities, sanitary and miscellaneous equipment, as directed (see Drawing 2,
Site Plan. There will be no new tanks, utilities, sanitary or miscellaneous equipment
Comment 5e: Compliance with Fire Apparatus Requirements in accordance
with the NYS Uniform Fire Prevention Building Code.
Response: The applicable sections of the NYS Uniform Fire Prevention Building
Code are: 503.1.1, 503.1.3, 503.2.1, 503.2.2, 503.2.3, 503.2.4, 503.2.5., 503.2.7,
503.2.8, 503.3, and 503.4. The current plan complies with all specific provisions of
the Code, and the Applicant will submit to modifications required by the Fire Code
Official, in compliance with sections 503.2.2.
Specifically, unless the building is sprinklered throughout with an automatic sprinkler
system installed in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Code, the basic code requirement is that a 20-foot-wide Fire Access Road should
extend to within 150 feet of all portions of the facility and all portions of the exterior
walls as measured by an approved route around the exterior of the building or
facility. In the subject instance, the property is accessed by a 20-foot-wide fire
access road from which all portions of the exterior walls can be accessed within 130
feet.
Comment 6: The previous application for the car wash and oil service change
included controls for storm water mitigation (water quality of impervious
surface) and the installation of an onsite water oil separator. Gray water from
washing activity was to be collected in a separate system, stored and re-used,
creating minimal discharge from the site. Plans shall be revised to accurately
depict the location of these practices.
Response: There is no requirement for storm water detention. The existing storm
water drainage system will remain as is. There is no increase in impervious surface.
The existing drainage flows through an existing oil water separator that shall remain,
and shall be maintained by the applicant.
Comment 7: Since the site is directly across from the Annsville Creek
(brackish estuary), it is strongly recommended that internal controls for
automotive fluids and waste oil be installed to capture any discharge. The
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 49
Page 6
intent of the original exterior controls was to capture pollutants and sediments
generated by storm event and limited car wash soap and oil that may have
escaped the service bays.
Response: Internal controls will be installed per NYS Plumbing Code for automotive
fluids and waste oil to capture any discharge.
Comment 7a: The report states the largest vehicle anticipated to be serviced is
a 24-ft trailer. Turning diagrams for this vehicle have not been provided. The
Applicant shall demonstrate graphically to scale the required turning
movements of a 24-ft tractor to determine if similar back-up and compound
turns are required to effectively enter and exit the bays and site.
Response: The vast majority of vehicle accessing the site will be Single-Unit (i.e. no
trailers) vehicles, 24 feet or less in length. To provide conservative analysis and to
be able to accommodate a larger vehicle, if it was ever needed, the site has been
designed to accommodate 30.65-foot-long tractor cabs. Circulation for most other
vehicles follows the same paths as shown on the turning drawings but with much
greater ease.
Comment 7b: Diagrams were provided for a 30.65-ft Lowboy tractor which
necessitates all vehicles to back-up into the repair and storage bays. While
the diagrams demonstrate there is enough space for maneuvering of this
vehicle, both the vehicle overhang and outside edge of tires come very close
to the front yard parking, building edge and curbing. The turning diagrams
provided also indicate the trailers will need to make a 3-point turn when
existing bays. There is little room for error.
Response: The facility layout has been modified to eliminate the need for even a
30.65 tractor cab to make any 3-point turns. The plans show that, if such a vehicle
were ever brought to the site for service, it could be accommodated. Circulation for
most vehicles visiting the site will be significantly easier, as described above.
Comment 7c: It is recommended to request of the Applicant clarification as to
how vehicle will be delivered to the site. As currently demonstrated, vehicles
would not be able to be delivered onsite by tow trucks or similar flat bed.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 50
Page 7
Response: The Applicant is willing to accept a condition that a strict policy be
placed on the facility that no towed vehicles will be accepted. All vehicles seeking
service and repair must be driven to the facility. All other or disabled vehicles will be
directed to one of the Applicant’s other facilities.
Comment 7d: Larger box and delivery trucks servicing the site will also be
limited in their ability to enter and exit. The Applicant shall provide narrative
and response as to how deliveries will occur and whether the intent is stage
within the NYSDOT right-of-way?
Response: All deliveries will be made by 30-foot or smaller trucks which will enter
the site, drive around the back of the building, deposit the delivery and then drive out
of the site, as shown on the SU-30 truck turning drawings.
Comment 8: On- and Off-site Landscaping
Response: Landscaping has been provided to meet the minimum interior
requirements of the zoning code. Off-site plantings are of such size and variety to
mitigate removal of vegetation originally associated with the disturbances generated
by the temporary off-site use of land on Camp Smith required to construct the site
improvements. Restoration of temporary disturbances are not credited towards
required onsite planting.
Comment 9: The Kimley Horn drawings indicate that for in order for trucks to
back into 1 NE bay, 2 NE bay, and 3 SW bay, they must drive over parking
spaces. Revise so trucks do not have to drive over parking spaces to exist the
site.
Response: The plan has been revised so that trucks do not have to drive over
parking spaces.
Comment 10: WCDOH, NYSODT and DMNA are all agencies having approval
jurisdiction. Prior to the approval of this site plan, it is recommended that
written comment, permitting and mitigation requirements be captured in the
resolution and reflected on the site plans.
Response: The applicant agrees that an approval shall include a requirement to
obtain all outside agency approvals and to comply with the requirements of those
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 51
Page 8
agencies. We will continue to keep the Town informed of progress with those
agencies.
Comment 11: Additional comments related to standard details and
construction improvement drawings will be made upon subsequent
submittals.
Response: Comment noted.
kimley-horn.com 1 North Lexington Avenue, Suite 505, White Plains, New York 10601 914-368-9200
Page 52
NB
b
Ca
ctor
Tra
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 53
Trac
tor
Cab
SB
SB
NB
SB
SB
SB
SB
NB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 54
Trac
tor
Cab
SB
SB
NB
SB
SB
SB
SB
NB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 55
Trac
tor
Cab
SB
SB
NB
SB
SB
SB
SB
NB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 56
SB
SB
Cab
ctor
Tra
NB
NB
SB
SB
SB
NB
SB
NB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 57
SB
Cab
ctor
Tra
SB
SB
NB
NB
SB
SB
SB
NB
NB
SB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 58
Cab
ctor
Tra
SB
SB
SB
NB
NB
SB
NB
NB
SB
SB
NB
NB
SB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 59
Cab
ctor
Tra
SB
SB
NB
NB
SB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 60
NB
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
TZ
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 61
NB
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 62
NB
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 63
NB
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 64
NB
SB
SB
NB
NB
SB
SB
NB
NB
PROJECT:70 ROA HOOK ROAD
DATE: 03-23-2026
DESIGNED BY: JC © 2025 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
DRAWN BY: 1 NORTH LEXINGTON AVENUE, SUITE 505
AD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 65
C:\Users\Gavin.Divincent\OneDrive - KH\Desktop\Lighting\Peterbilt\Electrical\references\Exhibit B (11x17).dwg
0.0 0.0
0.0
LEGEND 0.0 0.0
0.0 0.0
0.1 0.1 0.0
0.1 0.1
WALL MOUNTED LIGHTING FIXTURE 0.1 0.1 0.0
0.1 0.2 0.1
0.1 0.2 0.2
0.1 0.2 0.2 0.1
0.1 0.2 0.3
GENERAL NOTES 0.1 0.2 0.4 0.2
0.1 0.2 0.4 0.3
0.1 0.2 0.5 0.5 0.1
0.1 0.2 0.4 0.5
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL 0.1 0.2 0.4 0.7 0.2
0.0 0.2 0.5 0.8 0.5
CITY/COUNTY/STATE REGULATION AND CODES. 0.1 0.5 0.8 0.7 0.1
0.1 0.5 0.7 0.8
0.4 0.7 0.8 0.2
0.1 0.4 0.7 0.9 0.5
2. ALL PHOTOMETRIC VALUES SHOWN ON SITE PLAN IN 0.3 0.8 0.9
0.1 0.8 B B 0.1
TABLES ARE IN FOOTCANDLES (FC). 1FC = 10.76 LUX. 0.6 0.8 0.1
0.1 0.7 0.7 C 0.4
0.5 0.9 0.8
3. CALCULATED VALUES ARE DERIVED THROUGH A 0.2 1.1B B 0.1
0.6
COMPUTER BASED MODEL WITH LIGHT FIXTURE DATA 0.7
0.1 0.6 0.4
AS SUPPLIED BY MANUFACTURER THROUGH IES FILES. 0.3 0.7 0.1
B 0.9
4. ANY DEVIATION FROM SPECIFIED FIXTURE MODELS AND 0.1 0.7 C 0.3
0.4 0.6 0.1
MOUNTING HEIGHTS IN THIS EXHIBIT WILL DISCOUNT 0.1 1.0
THE VALIDITY OF THESE CALCULATIONS. 0.1 0.7 C 0.2
0.6 0.5 0.1
0.2 3.8A A 1.3
2.8 1.7
5. THE PHOTOMETRIC ANALYSIS EXCLUDES ALL EXISTING 3.8 0.1
0.1 0.8 4.2 0.4
PROPOSED OFF SITE STREET LIGHTING AND 0.6 4.5 0.1
0.3 1.0
LANDSCAPE LIGHTING. 4.1 1.9
3.5 2.8
0.1 0.9
C 3.3 0.3
0.7 3.2 0.6 0.1
6. PROPOSED BUILDING MOUNTED LIGHTS ARE SHOWN 0.4 A 3.8 1.0
MOUNTED AT 12'. 3.8 1.3
0.1 0.7 1.6 0.1
0.5 2.1 0.3 0.1
0.2 2.9 0.5
3.4 0.6
0.1 2.5 0.7
0.9 1.1 0.0
0.5 1.9 0.2
0.2 2.7 0.2
2.9 0.2
0.1 0.9C A 0.5 0.0
0.6 1.1 0.1
0.3 1.9 0.1
0.1 1.5 0.1
0.6 0.3 UND
0.6 0.7 0.0 E FO OP.
0.3 1.1 N PIP
IRO NE OF
PR
T
1.0 '
0.66 NER HAL
ASP
0.1 0.2 COR E OF
EDG
0.3
0.7
0.4
0.3 0.00.0
0.1 C 0.3 0.0
0.1 0.1 0.0
0.6 0.0
0.3 0.0 0.0
0.1 0.1 0.1 0.0
0.1 0.1 0.0 0.0
0.4 0.0 0.0
0.0
0.1 0.0
0.0
0.0
0.0 0.0 LINE
FOG
Saved Wednesday, March 25, 2026 12:51:50 PM GAVIN.DIVINCENT Plotted Wednesday, March 25, 2026 12:52:47 PM Divincent, Gavin
0.0
0.0 0.0
IRON ROD
0.0
FOUND ON
PROP. CORNER
0.0 0.0
0.0
D
0.0 OA
O KR
A HO IDGE
AS
PH
AL
T
RO I LLE
BR
OF E9 SV
T GE UT -ANN
AL ED
R O L L
PH US KSKI
AS E
PE
KHA PROJECT: 122233000
Leal Peterbilt DATE: 03-25-2026 NORTH
70 Roa Hook Road
Town of Cortlandt, New York
SITE PLAN DESIGNED BY:
DRAWN BY:
GAD © 2021 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
1 NORTH LEXINGTON AVENUE, SUITE 505
GAD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 66
C:\Users\Gavin.Divincent\OneDrive - KH\Desktop\Lighting\Peterbilt\Electrical\references\Exhibit B (11x17).dwg
Saved Wednesday, March 25, 2026 12:51:50 PM GAVIN.DIVINCENT Plotted Wednesday, March 25, 2026 12:52:47 PM Divincent, Gavin
KHA PROJECT: 122233000
Leal Peterbilt DATE: 03-25-2026
70 Roa Hook Road
Town of Cortlandt, New York
DETAILS DESIGNED BY:
DRAWN BY:
GAD © 2021 KIMLEY-HORN ENGINEERING AND
LANDSCAPE ARCHITECTURE OF NEW YORK, P.C.
1 NORTH LEXINGTON AVENUE, SUITE 505
GAD
WHITE PLAINS, NY 10601
PHONE: 914-368-9200
CHECKED BY: JC WWW.KIMLEY-HORN.COM
Page 67
JOHN J
9'
8' x 20' wood stockade fence GILCHRIST
Zoning Schedule 166.8
recycling & dumpster enclosure
AWE-2 Annsville Waterfront Enhancement District Ordinance Approved Proposed N49°
05' 00"E 32.0'
ALT
ARCHITECT
9.0'
H
32.0' ASP
A Professional Corporation
B. (1) Dimensional requirements
32.0'
Table of Required
32.8'
(a) Minimum Lot Area 7,500 28,061 28,061 one story addition
22.5'
32.0'
(b) Minimum Lot Width 50 173 173
376 sq ft
Permits
22.0'
34.6'
(c) Maximum Building Coverage 30% 16.6% 23.5% 1. Town of Cortlandt Site Plan
HAL
T MEN
T Approval, Steep Slope Permit, Tree
10.0'
S27°24'00"E
ART
(d) Yards ASP
CNC. E DEP Removal Permit & Building Permit
UTIV
22.0'
S EXEC 2. Westchester County Department
NY 2-1
Required Front Yard 10 50.6 24
22.0'
30.1' N/F 22.15- of Health Well & Septic approvals
TRAVELED TA X #
WAY 3. New York Department of
40.0'
Required Side Yard 10 34.1/30.1 30.1/30.1 Transportation Road Opening
30.0'
30.1' Permit
162.08'
Required Rear Yard 10 30.0 32.8 20.1' 9.4'
CNC.
Index
22.0'
(HC District) Buffer to ROW 25 0 0
22.0'
1. Zoning Plan
4.0'
(e) Maximum Height (stories) 2.5 1 1 CNC.
2. Site Plan
CNC.
1 STORY
STRUCTURE #70 CNC.
(f) Maximum Height (feet) 35 35 26 3. Landscaping Plan
1.0' 9.0' 20.1' 4.0' 98.0' 30.1' 4. Floor Plans
22.0'
4.0'
34.1'
E. (7) (b) Suggested pervious, landscaped areas 25% 11.3% 11.3% portion of building to remain 5. Building Elevations
N/F NYS EXECUTIVE DEPARTMENT
3,356 sq ft ASPHALT
6. Site Details
22.0'
13.5' 8.0' 8.0'
4" wide white epoxy paint
7. Septic Plan
Existing Floor Area 4,649 4,649 striping typical
AREA=28060.8445±SQ.FT.
22.0'
Demolition -1,290
75.0'
ACRES=0.6442±
TAX#22.20-2-1
CNC.
CNC.
E
Additions 3,241 4"
2 STORY
59.4'
N27°24'00"W 190.08'
'
0 '2
portion of building to be removed
2 °1 .89
Total Building Area 4,649 6,600 one story addition
1,290 sq ft
NYS DISK
FOUND N2 60
2,865 sq ft
Parking “Other automobile repair & services”
22.0'
44.0'
50.6
ND
FOU
IPE PROP.
'
1 per employee 6 6 ASPHALT
N P
IRO NE OF
' HAL
T
0.66 NER F ASP
COR EO
1 per 150 square feet of gross floor area 8 EDG
4.5'
44
162 sq ft
Total Parking 50 12 14 TRAVELED revised per review
22.0'
3–25-26 JJG
WAY letters
Lot Coverage 24,890 24,890
12.0'
0
24'
1–22-26 for review JJG
0.0% new 56 square feet wall
9-29-25 for review JJG
mounted business
4"W
identification sign 07'2
43°
new 24 square feet 1 2.78
' S
FO
GL
INE SB Date Issue Initial
W1 NB
RO LINE
freestanding business
FOG
Zoning Plan
identification sign
0'
16.
SB
'22"W NB
4 °52
IRON ROD S3
SIGNATURE BLOCK FOUND ON
.2 0'
Required for Subdivisions and Site Plans PROP. CORNER 63 NB
W
RO
A D New Sales & Service Building
The Department Head signatures indicate that this drawing or set of drawings is consistent
K RO for
with the Planning Board resolution of approval and with the general requirements and O NB
policies of the Town of Cortlandt for which the Department Head is responsible. The SB
A HO RID
GE R3-2 "No Left Turn" Leal Peterbilt
project design including all public health and safety considerations are solely the
PH
ALT
RO I LLE
B NYR7-5P "7 AM - 9 AM
responsibility of the design professional who has signed and sealed the drawings. EO
F AS
E 9 NNSV 4 PM - 6 PM WEEKDAYS" 70 Roa Hook Road
T G U T Town of Cortlandt
AL
ED
SB RO ILL-A Note: If safety or operational issues arise the
Reviewed by the Department of Environmental Services1 P H U S K Westchester County
AS TRY E KS 0) time restriction on NB left turn entering may
PE . 185 be removed & all left turns prohibited New York
EN Y H
WA (S. Lot 1 Block 2 Section 22.20
__________________________________ _________________________
NB
Director Date
PLAN
E
Zoning Plan NORTH
LIN
NB
Reviewed by the Department of Planning & Community Development
SB FO
G
Scale: 1" = 20.0'
E
__________________________________ __________________________
OG
LIN
R E EK 0 10' 20' 40'
F SB C
LE
Director Date Prepared with information taken from
C. S E VIL "Property Survey & Topography 70 Roa Hook
ANN
N Rd (US RT 9) Cortlandt Manor, New York
CO RB Prepared for Steven Auth" by Rowan Land
Reviewed by the Planning Board Engineer CU NB
Surveying, PLLC dated October 14, 2017
AL
MET D
NB
__________________________________ ___________________________ A R
GU
L
Engineer Date RAI
IL
RA
8'-0"
D
AR
existing 45MPH SPEED LIMIT
GU sign to be relocated 250' east
NY 024343-01 exp 03-31-2027
AL
Approved by Resolution No.______ of the Planning Board of the Town of Cortlandt, New
ET It is a violation of the law for any person, unless
3'-3"
York on the ______day of ________________, subject to all requirement and conditions of
M acting under the direction of the licensed architect,
said Resolution. Any change, erasure, modification or revision in this plat or site to alter any item in the plans, specifications or
development plan, after the above date, shall void this approval. reports to which the seal of the architect has been
applied in any way. If an item bearing the seal of an
architect is altered, the altering architect shall affix
Signed this _______ day of ___________________, 20____ by aluminum frame w/ to this item the seal and the notation "altered by"
polycarbonate faces internally followed by the architect's signature and the date of
such alteration and a specific description of the
illuminated double faced sign alteration.
PQ
20 square feet
___________________________________
John J Gilchrist
16'-0"
Chairperson of the Planning Board
Stephen Ferreira, P.E., Director DES
Chris Kehoe, AICP, Planning Director
737-0100
734-1080 steel pole
Architect
Planning Board Engineer 734-1080 A Professional Corporation
8 Coach Lane
concrete base Upper Saddle River
Sources: Esri, HERE, DeLorme, Intermap, increment P Corp.,
New Jersey 07458
GEBCO, USGS, FAO , NPS , NRCAN, G eoBase, IGN, Kadaster NL,
Ordnance S urvey, Esri Japan, METI, Esri China (Hong Kong),
swisstopo, MapmyIndia, © O penS treetMap contributors, and the GIS
Phone 201 573 1877
JJGAPC@gmail.com
Freestanding Sign Detail
User Community
Site Location Plan 1" = 20.0'
Peterbilt
1 of 7
250311
Page 68
N/F NYS EXECUTIVE DEPARTMENT
25.1
JOHN J
CLEARED
GILCHRIST
TAX# 22.15-2-1
GRAVEL
AREA
General Notes 20 17 ARCHITECT
20
a. Prior to any construction beginning, the Applicant shall obtain a building 28.6
25 22.8
A Professional Corporation
20
permit administered through the Department of Technical Services – Office of 18.3
Code Enforcement.
16.6 15.2
PQ
b. Prior to the issuance of a building permit, the Applicant shall submit all third 36.4
27.2
16
party permits and approvals.
14.5
35
15 14.6
c. The Applicant shall organize a pre-construction meeting with representatives 33.2
30
17
34.6 19.0
16
34.8
of the Town of Cortlandt and NYSDOT. 15.6
IRON ROD existing bollards
15
34 16.6
FOUND ON
25 PROP. CORNER 13
d. Prior to the issuance of a building permit, the Applicant’s Contractor shall 20 IR F 14
15.3 I
RF existing domestic water well
submit a clearing and grading stakeout sketch as prepared by a licensed 30
15.7
1.2' 15.6 13.7
15.1 15.2
professional land surveyor that shall delineate the approved work area. All silt 0.3' 8' x 20' dumpster & recycling area
10'
27.8 15.4 15.7
fencing shall be installed along this line and proper erosion and sedimentation 9' 10'
17.4
26
25.6
166.814.9
22.5 15.5
14.9 U 12
garbage & recycling is the responsibility of
25
controls shall be installed and inspected. 22
WELL
the Owner through private carting services
32.0'
17.7
00"E
9°05'
15
15
12
N4
CC 14.6
T
e. No construction debris or recycled material is permitted on site. All imported 15.2 HAL
9.0'
17 ASP
32.0'
24.6
25 14.8 15.4
to well
10
fill shall be laboratory tested and determined to be clean fill in accordance with 20 X CC 15.7 15.6 9.7
applicable NYSDEC guidelines for residential and commercial fill. 16.2 CRW
0.7'
14.3 CC 12.6
32.0'
24.8 A
15.2
32.8'
1.36' RIM:14.41' 12.5
IRF B
inimum
f. Garbage and recycling is the responsibility of the Owner through private INV A: 12.97' 4"PVC 14.8 9.7
22.5'
14.4
15
13
32.0'
24.4 INV B: 11.21' 15"CPP
carting services. 16.3 A
12
15.7
22.0'
14.1 14.8 15.2
RIM: 14.2'
Sources: Esri, HERE, DeLorme, Intermap, increment P Corp.,
34.6'
Site Location Plan
100' m
B
g. The Owner/Applicant is advised that no blasting is permitted onsite without
INV A: 10.68'
14.5 rainwater storage 14 13.4N/F NYS EXECUTIVE
INV B: 10.68'
GEBCO, USGS, FAO , NPS , NRCAN, G eoBase, IGN, Kadaster NL,
17
15"CPP 14.2 tank to be abandoned 15.1 15.1 15.1 15.2 rain15.3
water storage
13.6 tank to be abandoned
an approved rock removal and blasting plan as approved by the Department of 23.8
CRW
14.8
15.1 15.6
11.4
DEPARTMENT Ordnance S urvey, Esri Japan, METI, Esri China (Hong Kong),
15 15
Technical Services. T
SR
LT 12.7
EN swisstopo, MapmyIndia, © O penS treetMap contributors, and the GIS
PHA
10.0'
RTM
S27°24'00"E
W
23
AS 15.1 CNC.
15.4 12.5 TAX# 22.15-2-1 DEP
A
User Community
TIVE
16.2 15.0 15.7
W 15.5
ECU
22.0'
15.1
h. At the completion of construction a comprehensive as-built survey is required SR
15.2 U
14.3 E X
NYS
14.7
2-1
22.0'
and shall be prepared by a NYS licensed land surveyor.
14.4 U U
15.1 30.1' rain water storage tank to be abandoned N/F 22.15-
TRAVELED U 15.2 15.7 15.7
TA X #
N
BASI
WELL 15.0 :
LET '
CHAMBERS
WAY CHAMBERS
E IN
40.0'
X UNDER14.9 15.3
PIP PP: 12.
5
CH
CAT '
UNDER
i. At the completion of construction, the Applicant’s Engineer shall certify that 18
: 7.38 "CMP
22.8
24"C L
22.6
E
30.0'
all retaining structures were built in accordance with the approved plans on file 30.1' M
RI ' 12
FFE
U
: 6.23 " PIPE
162.08'
.19
24"C
1
=15.5
with the Town and that all factors of safety for sliding, overturning and 15.5
20.1' 9.4'
16.4
IN V '8
15
20
CNC.
: 3.63 CP
15.6
E=
22.0'
INV 2 .63' 24" R
8
settlement have been met. ROOF
PP
FF
14.6 21.4
DRAIN
22.0'
:3
15
INV 3
(TYPICAL)
FF
14.9
15.1
E=
20
j. A foundation survey is required to be submitted to the Department of Technical 15.2
1
4.0'
16
5.2
22.3 22 16.3
7
16.0
Services upon completion which shall verify that all footings and setbacks including CNC. 17.5 27.4
2
CNC.
15.0 15.2 15.3
1 STORY 15.2 15.1 28.1
15
14.2 CO U U U
granted variances have been met STRUCTURE #70 CNC.
U U
18.6'
U
1
21.0'
15.0 25
1.0' 9.0' 20.1' 4.0' 98.0' 30.1'
15.0
3
22.0'
k. Copies of permit & approved plans shall always be on the work site during
4.0'
34.1' 15.2 15.1
15 P revised per review
" CM
A U
construction four
15 low boy settling tanks w/ wiers
14.5
3–25-26 JJG
12
21.8
21.5 RIM: 14.10'
14.8
be abandoned16.7
wash water recycling system to23.5 21.5 7.76 letters
20
N/F NYS EXECUTIVE DEPARTMENT 20
20
INV A: 10.26' U U ASPHALT
SB
B
22.0'
TAX# 22.15-2-1
4.0'
10.8'
INV B: 10.26' U
l. Excess cut soil shall be legally disposed of off site. No rock crushing is proposed. 1–22-26 for review JJG
17
15"CPP
15.2 13.5' 8.0' 8.0'
rainwater collection tanks to be removed 14.8
14.7 SB SSB
CHAMBERS B
18
EOA
UNDER 16.1
m. On site soil to be used for any purpose on site shall be certified by the design U 15.2 14.4 9-29-25 for review JJG
21.6 15.3 CRW 15.0 15 10 9
professional and approved by town engineer. AREA=28060.8445±SQ.FT. 8 SB
22.0'
14.5 14 13.5
75.0'
15 ACRES=0.6442±
Date Issue Initial
FF 13.4 14
14.1 U E=
15
.2 5 TAX#22.20-2-1 12.5
SB
CNC.
CNC.
E 12.4 10
4"
0.2' 2 STORY 13.5 CC
13.7
13.7 15 9.30
59.4'
10.3
N27°24'00"W
2
Site Plan
20.9 U ' SRW 8.5
10 9'
21
13
14.6 14.8 14.6
2 2° 0.8 8.6
NE SB NB
NYS DISK
LI
14.7
N 6
8.8
FOG
14.9
13.4 12.2 FOUND 10
8.5 9.6
21.5 12.4 8.9
22.0'
CC 12.4
12
44.0' SB
50.6
12 9.6
9.6
15 190.08'
ND 9.22
FOU .
PIPE PROP
8.8
NB
'
14.3
NB
22.2 N
IRO NE OF ALTT 8.16
ASPHALT HAL
9.6
14 '
0.66 NER SPH 9.7
ET:
22 IIRF
RF R 9.5 E O ASP
FF A UTL 9
DG E O E O 9.2'
21.5 O
12.1 C
EDG P
SB
14.2 E I
4.5'
13.8 13.5
10.0 10.3
IIPF 10.3 P PP:
PF 9.7
N/F NYS EXECUTIVE CC 9.7
9.6
9.9 9.57 24"C
New Sales & Service Building
NB
12.3
10 10
for
9.7
DEPARTMENT TRAVELED
CC 9.7
22.0'
9.9
9.8 10.27
Leal Peterbilt
10.2 GRAVEL
13 RIM: 11.77' SRW 9.6
WAY RIM: 13.73' 13.6
INV A: 7.33' 15"CPP RIM: 9.35' 9.6
6' curb terminal
NB
TAX# 22.15-2-1 21.4 11.1
12.0'
A INV A: 9.45' INV: 7.58'
14.5 CC
5
24'
INV B: 9.17' 4"PVC CC
INV B: 9.35' 15"CPP 10' external curb extension
20 15"CPP
INC C: 7.2' 15"CPP
B
12.8 9.84
70 Roa Hook Road
12.2 A
B
CC C new pavement 8.53 6.71
10.1
13.9 13.2
CC
"W
10.7 9.5
GRAVEL 10.18
NB
Town of Cortlandt
12.6
7'2 411.7 Flood Linesawcut pavement 2' from white line
new 100 Year10.2 Westchester County
3°0
A B CC
4
8' S
13.5 Elev. 10.5 NGVD 1929
SB New York
D 1
RIM: 13.51' 3 10 INE
GL
12.7
15.5 10.2
INV A: 6.21' C 12.5
FO 8
13 INV B: 6.21'
W1 10.2
NB NE
5.63 Lot 1 Block 2 Section 22.20
Oil15Water Separator 12.5 INC C: 6.0'
RO11.5 10.3 9.9
8.80
G LI
top 10.5
FO RAI
L
15"CPP
10.19
'
90.8
0
RD
see detail on drawing 7
16. 10.2 10 B
"W 100 YearSFlood Line
AL GUA
'
NB
A
12.4
2 MET
2'2
10.4
11.7 Elev 10.5 NGVD 1929
4°5
12 10.51
(Elev 9.5 NAVD) 7.10
S3
B
CC
IRON ROD
' 10.4
.20
FOUND ON 11.6
11.7 9.13
PROP.
12.2 CORNER IPF 63 NB
W 10.38
RO
D
RIM: 9.59' 10.5
OA
11
INV A: 5.72' 15"CPP 8
R
INV B: 5.44' 24"RCP
K
IRF
O NB
HO
10.8 IRF
SB GE 7.35 5
OA
11.5
RID
24
11.2 10.9 10.6
11.4 10.36 T
R EB
"R
AL
ILL
11.3 H
CC
SP
99.
10.7
FA 9.36
E9 S V
CP
10.8 O
T N 2
7'
GE
AL
T ED
SB R OU LL-AN
PH US KSKI
AS TRY 10.86 10.7 E
PE . 185
0)
EN Y H
(S.
10.66
WA
10.9
11.1
11
CC
97
10
NB
.1'
PLAN
NY 024343-01 exp 03-31-2027
10.8
7.84
Site Plan NORTH It is a violation of the law for any person, unless
INE
10.9
5 acting under the direction of the licensed architect,
L
SB NB FO
G
Scale: 1" = 20.0'
to alter any item in the plans, specifications or
reports to which the seal of the architect has been
applied in any way. If an item bearing the seal of an
E
11.54
G
LIN 9.59
R E EK 0 10' 20' 40' architect is altered, the altering architect shall affix
to this item the seal and the notation "altered by"
FO SB C
LLE
7.68 Prepared with information taken from followed by the architect's signature and the date of
.
10.8
E V I "Property Survey & Topography 70 Roa Hook such alteration and a specific description of the
NC S alteration.
ANN
10.76 R 24" RCP Rd (US RT 9) Cortlandt Manor, New York
O
C RB ATE RK)
John J Gilchrist
W A EL: 1.3' Prepared for Steven Auth" by Rowan Land
CU NB E OF ER M
G T Surveying, PLLC dated October 14, 2017
ED H WA
Architect
G
AL
MET D (HI
NB U A R
G
IL
RA
9.72 9
RA
IL A Professional Corporation
SB RD
LG
U A
8 Coach Lane
TA
SB M E Upper Saddle River
11.43 8.20
New Jersey 07458
7.22
Phone 201 573 1877
NB
10.80
.
NC B JJGAPC@gmail.com
CO UR 7 Peterbilt
C
NB LINE 1" = 20.0'
2 of 7
OG
F
250311
Page 69
JOHN J
Permanent Seeding: Tree Removal & Protection Notes GILCHRIST
Permanent seeding will be applied immediately after the final 1. All removal of trees on property are to be minimized
ARCHITECT
design grades are achieved at the site but no later than 14 days & shall be tagged by the contractor & inspected by the A Professional Corporation
N/F NYS EXECUTIVE DEPARTMENT
after construction activities have permanently ceased. After Town of Cortlandt prior to cutting. Tree wells shall be CLEARED TAX# 22.15-2-1
25.1
the entire site is stabilized, any sediment that has accumulated constructed around all trees that would be impacted as GRAVEL
AREA
will be removed and hauled off site to a licensed landfill a result of cutting & filling 20 17
facility. Construction debris, trash, and temporary BMP’s will
20
25 22.8
28.6
also be removed in areas disturbed during removal will be 2. All trees designated for preservation shall be clearly 20
18.3
seeded immediately. marked w/ a bright colored ribbon or other easily 16.6 15.2
27.2
discernible method. 36.4 16
Seedbed Preparation: 35
14.5
15 14.6
30
33.2
17
34.6 19.0
16
34.8
a. Topsoil will be spread over final graded areas at a minimum 15.6
15
34 16.6
depth of four inches. 25
20 IRF 13 14
15.3 I
RF
b. The seedbed will be free of rocks, woody debris and other 30
15.7
1.2' 15.6 13.7
objectionable material. 15.1 15.2
0.3'
27.8 15.4 15.7
17.4
c. Fertilizer will be applied to the seedbed as specified in the
26
25.6 22.5 15.5
14.9 14.9 U 12
25 WELL
appendix. 22 42 RJ 32.0' 15
17.7
15
12
CC 14.6
d. Topsoil will be loosened by raking, tilling or other suitable 15.2 HAL
T
9.0'
17 ASP
32.0'
24.6
methods. 25 14.8 15.4
10
15.6 9.7
20 CC 15.7
Installation schedule: Portions of the site where construction
0.7'
14.3
16.2 CRW CC 12.6
32.0'
24.8 A
15.2
32.8'
1.36' RIM:14.41' 12.5
IRF B
activities have permanently ceased will be stabilized, as soon INV A: 12.97' 4"PVC 14.8 9.7
22.5'
14.4
15
13
32.0'
24.4 INV B: 11.21' 15"CPP
16.3 A
376 sq ft
12
15.7
22.0'
as possible but not later than 14 days after construction ceases. 14.1
RIM: 14.2' 14.8 15.2
34.6'
B INV A: 10.68'
INV B: 10.68' 14.5 14 13.4
17
13.6
Maintenance and Inspection: All seeded areas will be inspected 23.8
CRW
15"CPP 14.2
14.8
15.1
15.1 15.1 15.1 15.2
15.6
15.3
11.4
15 15
NT
SR
T 12.7
E
HAL
10.0'
weekly during construction activities for failure until a dense RTM
W
ASP
23
15.4 EPA
VE D
16.2 15.0 15.1 CNC. 15.7 12.5
W 15.5 I
CUT
22.0'
15.1
SR
15.2
EXE 1
14.3 U
cover of vegetation has been established. If failure is noticed 14.7
N Y S 2-
22.0'
14.4 U U
15.1 30.1' N/F 22.15-
TRAVELED WELL
U
15.0
15.2 15.7 15.7
TAX #
:
LET '
CHAMBERS
on the seeded area, the area will be seeded, fertilized and WAY CHAMBERS
E IN
40.0'
UNDER14.9 15.3 5
22.8
UNDER PIP PP: 12. 18
22.6 24"C revised per review
30.0'
30.1' U
3–25-26 JJG
mulched immediately. After construction is complete at the site letters
24"C
16.4
15.5
20.1' 9.4'
20
CNC.
15.6
22.0'
permanent stabilization measures will be monitored until final landscaped areas to be mulched w/ ROOF
landscaped areas to be mulched w/ 1–22-26 for review JJG
P
14.6
P
DRAIN 21.4
22.0'
3" of hemlock bark mulch 15
(TYPICAL) 14.9 3" of hemlock bark mulch
15.1
20
stabilization is reached. 15.2
9-29-25 for review
4.0'
JJG
16
limit of disturbance
22.3 22 16.0
16.3
CNC. 17.5 27.4
CNC.
15.0 15.2 15.3
1 STORY 15.2 15.1 28.1
15
Date Issue Initial
14.2 U U U U U
STRUCTURE #70 CNC.
U
15.0 25
1.0' 9.0' 20.1' 4.0' 98.0' 30.1'
15.0
22.0'
4.0'
Landscaping Plan
A 34.1' U 15.2 15.1
15
Plant List 15
21.8 14.5 14.8
21.5 RIM: 14.10' 16.7 21.5
20
N/F NYS EXECUTIVE DEPARTMENT 23.5 20
20
B
INV A: 10.26' U U 3,356 sq ft ASPHALT
22.0'
TAX# 22.15-2-1 INV B: 10.26' U
17
Key Scientific Name Common Name Quantity Size 15"CPP
15.2
14.8
13.5' 8.0' 8.0'
14.7 SB SSB
4" wide white epoxy paint CHAMBERS B
18
DW Cornus Sericea "Flaviramea" Yellow Twig Dogwood 6 2 1/2”caliper striping typical U 15.2
UNDER
14.4
16.1
21.6 15.3 CRW 15.0
AREA=28060.8445±SQ.FT. 15
22.0'
RJ Juniperus Horizontalis "Wilton" Wilton's Blue Rug Juniper 14 2 gallon 14.5 14 13.5
75.0'
15 ACRES=0.6442± 13.4 14
14.1 U 12.5
TAX#22.20-2-1
ML Kalmia latifolia Sarah Sarah Mountain Laurel 4 2 gallon New Sales & Service Building
CNC.
CNC. 12.4 10
0.2' 2 STORY 13.5 CC
13.7
13.7 15
59.4'
10.3
GC Chamaecyparis pisifera Golden Cyprus 4 2 gallon 20.9 U SRW 8.5
for
21
13
BS Picea pungens Waldbrunn Waldbrunn Dwarf Blue Spruce 4 5 gallon
Leal Peterbilt
14.6 14.8 14.6 8.6
14.7 NYS DISK 8.8
14.9 1,290 sq ft 12.2 FOUND 8.5 9.6
WA Azalea Delaware Valley White White Azalea 4 5 gallon 13.4
12.4 10
21.5 2,865 sq ft 8.9
22.0'
70 Roa Hook Road
CC 12.4
12
44.0' 2DW SB
50.6
12 9.6
R Rhododendron Northern Starburst Rhododendron 4 3 gallon 9.6
15
ND 9.22
FOU .
PIPE PROP
8.8
Town of Cortlandt
'
14.3
AV Thuja plicate “Green Giant” Green Giant Arborvitae 6 6’ height 22.2
ASPHALT 14 50
8 RJ
N
IRO NE OF LT 9.6
Westchester County
PHA
' 9.7
22 IIRF 0.66 NER F AS
ET:
RF UTL 9
R
New York
9.5 O E O 9.2'
21.5 O
Off Site Planting DGE
14.2 12.1 C I P
4.5'
13.8 13.5
10.0 10.3
IIPF 10.3 E P PP:
PF 9.7
24"C Lot 1 Block 2 Section 22.20
9.6
18 RJ 12.3
CC 9.7 9.9 9.57
6 AV 162 sq ft 10 9.7 10
RJ Juniperus Horizontalis "Wilton" Wilton's Blue Rug Juniper 60 2 gallon TRAVELED
CC 9.7
22.0'
9.9
13 RIM: 11.77' SRW
10.2 9.8 GRAVEL 9.6 10.27
21.4 WAY RIM: 13.73' 13.6
INV A: 7.33' 15"CPP
6 RJ CC 11.1
RIM: 9.35' 9.6
NB
12.0'
14.5 A INV A: 9.45' INV: 7.58' CC
24'
INV B: 9.17' 4"PVC
INV B: 9.35' 15"CPP
20 15"CPP
INC C: 7.2' 15"CPP
B
12.8 12.2 A 9.84
B
CC C 8.53
10.1
new 56 square feet wall CC 10.7 9.5
10.18
NB
13.9 13.2 GRAVEL
mounted business 12.6 11.7
10.2
identification sign
13.5
A B 4BS CC
INE SB
D 13
RIM: 13.51' 10
15.5
INV A: 6.21' C 2,246 sq ft
10.2
GL
new 24 square feet 12.5
FO 8
INV B: 6.21' 4 WA 10.2
NB
LINE
freestanding business
15 13 INC C: 6.0' 8.80
12.5 11.5
4R
FOG
10.3 9.9
identification sign 15"CPP
10.19
0' 10
16.
4 DW SB
REMOVE ENOUGH WHOLE BRANCHES TO REDUCE 10.2
FOLIAGE BY 1/3 (ALWAYS PRUNE TO NODE OR
NB
12.4 A
CROTCH RETAINING NORMAL PLANT SHAPE, DO DO NOT CUT LEADER 10.4
11.7
NOT CUT LEADER) 12 10.51
4 GC B 7.10
REMOVE ENOUGH WHOLE BRANCHES TO REDUCE
CC
IRON ROD 10.4
landscaped areas to be mulched w/
FOLIAGE BY 1/3 (ALWAYS PRUNE TO NODE OR 11.7 FOUND ON 11.6 3" of hemlock bark mulch 9.13
12.2 CORNER 4 ML
NB
CROTCH RETAINING NORMAL PLANT SHAPE, DO
PROP. IPF
NOT CUT LEADER)
10.38
AD
RIM: 9.59' 10.5
11
8
O
INV A: 5.72' 15"CPP
KR
INV B: 5.44' 24"RCP
2 STRANDS NO. 12GA GALVANIZED ANNEALED IRF
O NB
STEEL WIRE-TWISTED IN NEW RUBBER HOSE
HO
10.8 IRF
SB GE
5
6' MAX. MINOR TREE
7' MIN. MAJOR TREE
7.35
OA
11.5
RID
2 STRANDS DOUBLE
11.2 10.9 10.6 R3-2 "No Left Turn" NY 024343-01 exp 03-31-2027
R
WRAPPED AND TWISTED
11.4 10.36 T B
H AL
LE NYR7-5P "7 AM - 9 AM It is a violation of the law for any person, unless
VIL
CIRCLED WATERPROOF TREE WRAPPING 11.3
CC
SP
MULCH (3" LAYER) AS SPECIFIED
PAPER 4" SIDE-50% OVERLAP-TIED 10.7
FA 9.36 9 S 4 PM - 6 PM WEEKDAYS" acting under the direction of the licensed architect,
O
TE NN
2
WITH STOUT HEMPCORD AT TOP OF 10.8
GE U
OVER ENTIRE BED
T
6' MAX. MINOR TREE
SB A
BALL AND AT HEIGHT OF 2-ND BRANCHES
7' MIN. MAJOR TREE
to alter any item in the plans, specifications or
AL
ED O -
R LL Note: If safety or operational issues arise the
US KSKI
PITCH AWAY FROM TREE TRUNK
FORM 3" HIGH TOPSOIL LIP AROUND EACH
PH time restriction on NB left turn entering may
reports to which the seal of the architect has been
AS TRY 0)
applied in any way. If an item bearing the seal of an
SHRUB TO PROVIDE WATERING SAUCER FORM 4" HIGH TOPSOIL LIP EDGE
E
OF TREE PIT TO FORM WATERING 10.86 10.7
PE . 185 be removed & all left turns prohibited architect is altered, the altering architect shall affix
SAUCER
EN Y H
(S.
10.66 to this item the seal and the notation "altered by"
WA
10.9
6" 11.1 followed by the architect's signature and the date of
11
4" TREE BALL 4"
CC
ROOT BALL such alteration and a specific description of the
10
VARIES
alteration.
TOPSOIL MIX BACKFILL VARIES TOPSOIL MIX BACKFILL
NB PLAN
CUT AND REMOVE BINDING FROM TRUNKS
CUT AND REMOVE BINDING FROM TRUNK 10.9
10.8
E
7.84
Landscaping Plan NORTH
John J Gilchrist
LIN
AND AS MUCH BALL AS POSSIBLE 6"
AND AS MUCH BALL AS POSSIBLE 5
SB NB
CUT AND REMOVE BURLAP AT UPPER 1/3 CUT AND REMOVE BURLAP AT UPPER 1/3
G
FO
Architect
6" OF BALL OF TREE BALL
Scale: 1" = 20.0'
NE
16" TAMPED TOPSOIL MIX CUSHION 6"
LI EK 0 10' 20' 40'
TAMPED TOPSOIL MIX CUSHION 6"
11.54
FO
G 9.59
C R E A Professional Corporation
SB
ILLE
CEDAR STAKES MIN. 3" DIA., 3'-0" LENGTH
6" VARIES 6" 12" VARIES 12" 3 STAKES @ 120 DEG. PER TREE
7.68 Prepared with information taken from
V 8 Coach Lane
STAKES TO BE DRIVEN IN AFTER
10.8
. "Property Survey & Topography 70 Roa Hook
SE
ATTACHING TENSION WIRE TO TREE
NC 10.76
N Rd (US RT 9) Cortlandt Manor, New York
O
C RB A N
NOTES:
1. CONTRACTOR SHALL HAVE THE OPTION OF PLANTING SHRUBS IN INDIVIDUAL
PITS AS SHOWN OR IN UNINTERRUPTED EXCAVATION FOR ENTIRE BED, IN
NOTES:
1. PROVIDE 3" LAYER OF MULCH AS SPECIFIED OVER ENTIRE WATERING SAUCER AT ALL
CU NB
Prepared for Steven Auth" by Rowan Land
Surveying, PLLC dated October 14, 2017 Upper Saddle River
New Jersey 07458
EITHER CASE BACKFILL WITH TOPSOIL MIX AS SPECIFIED. TREE PITS OR OVER ENTIRE TREE BED.
AL
MET D
NB
R
Phone 201 573 1877
G U A
DECIDUOUS TREE N.T.S. I L
SHRUB PLANTING N.T.S. RA
9.72 9 IL
RA JJGAPC@gmail.com
D
UAR Peterbilt
G
AL 1" = 20.0'
MET 3 of 7
250311
1
Page 70
JOHN J
GILCHRIST
ARCHITECT
A Professional Corporation
4'-0" 8'-0" 7'-8" 34'-8" 16'-4" 31'-4"
addition
addition to service bays
10'-0"
existing office area to remain
addition
12'-0"
no part of this existing attic will
Storage Storage Mech'l
10'-0"
have ceiling height more than 7' 12'-0"
addition
40'-0"
new ADA restroom
28'-0"
Storage
existing restroom
19'-4"
open to below Office
existing stair Office
22RISE(6 29/32")
UP
21RUN(11")
steel stair
1
2
DOWN
3
10
12
13
14
15
16
17
18
19
20
21
22
11
4
5
6
7
8
9
revised per review
3–25-26 JJG
letters
Parts 1–22-26 for review JJG
9-29-25 for review JJG
15'-8"
three existing car wash bays to be used as service bays
PLAN PLAN
NORTH
4'-0"
NORTH Date Issue Initial
existing wash bay to be used as parts storage
portion of existing mezzanine w/ ceiling height of 7' or more
422 sq ft
Floor Plans
portion of mezzanine to be removed
New Sales & Service Building
two wash bays to be demolished
for
addition
815 sq ft
Leal Peterbilt
95'-0"
70 Roa Hook Road
Town of Cortlandt
Westchester County
New York
Lot 1 Block 2 Section 22.20
four new service bays
59'-4 1/2"
NY 024343-01 exp 03-31-2027
It is a violation of the law for any person, unless
acting under the direction of the licensed architect,
to alter any item in the plans, specifications or
reports to which the seal of the architect has been
applied in any way. If an item bearing the seal of an
architect is altered, the altering architect shall affix
to this item the seal and the notation "altered by"
followed by the architect's signature and the date of
such alteration and a specific description of the
alteration.
44'-0"
addition John J Gilchrist
Mezzanine Architect
Floor Plan A Professional Corporation
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0" 8 Coach Lane
Upper Saddle River
New Jersey 07458
Phone 201 573 1877
JJGAPC@gmail.com
Peterbilt
1/8" = 1'-0"
4 of 7
250311
Page 71
JOHN J
GILCHRIST
ARCHITECT
A Professional Corporation
revised per review
3–25-26 JJG
letters
1–22-26 for review JJG
9-29-25 for review JJG
Date Issue Initial
Building Elevations
60 square foot wall mounted sign
new construction
service bays addition aluminum frame w/ polycarbonate light grey corrugated metal roofing
existing to remain face & internal LED illumination
new construction New Sales & Service Building
portion of existing building to remain
for
Leal Peterbilt
70 Roa Hook Road
Town of Cortlandt
26'-0"
Westchester County
New York
Lot 1 Block 2 Section 22.20
light grey corrugated metal siding
North (Rear)Elevation South (Facing Rt 9) Elevation
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
NY 024343-01 exp 03-31-2027
It is a violation of the law for any person, unless
acting under the direction of the licensed architect,
new service bays newe serive bats portion of existing building to remain to alter any item in the plans, specifications or
reports to which the seal of the architect has been
applied in any way. If an item bearing the seal of an
architect is altered, the altering architect shall affix
to this item the seal and the notation "altered by"
followed by the architect's signature and the date of
service bay such alteration and a specific description of the
existing to remain addition alteration.
John J Gilchrist
Architect
A Professional Corporation
8 Coach Lane
Upper Saddle River
New Jersey 07458
Phone 201 573 1877
JJGAPC@gmail.com
West (Left Side) Elevation East (Right Side) Elevation Peterbilt
5 of 7
SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" 250311
Page 72
access frame & lid to be removed
JOHN J
6" SDR35 PVC roof drain leader
pavement to be removed & replaced
Tee w/ perforated opening guard
GILCHRIST
concrete cover to be removed or broken up
ARCHITECT
A Professional Corporation
roof drainage to be redirected
precast concrete tank
to onsite drainage system tank to be cleaned of any sediment
H-20 load rating
& filled w/ recycled concrete &
1" x 4" pressure treated
bituminous crushed stone wood stockade fencing
waterproofing
Tank Abandonment Detail 4" galvanized steel posts 6' oc
2" ASPHALT CONCRETE NYSDOT ITEM 403.16
6" concrete pad w/ #5
rebar 12" oc each way
concrete to be 3,000 psi
compressive strength @
28 days
TACK COAT SYSDOT ITEM 407.0101
fence posts set in 12" x
4" ASPHALT CONCRETE NYSDOT ITEM 403.13
36" concrete footings
4" SUBBASE NYSDOT ITEM 304.05
ORIGINAL SUB-GRADE TO BE COMPACTED
NOTE
THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ALL ROAD
COURSES ARE COMPACTED WITH A TEN TON ROLLER AND MEET THE
Dumpster Enclosure Detail
FOLLOWING DOT COMPACTION STANDARDS:
SUBBASE COMPACTION: ITEM 203-3.12
ASPHALT COMPACTION: ITEM 401-3.12
ON-SITE PAVEMENT SECTION 3–25-26
revised per review
letters
JJG
1–22-26 for review JJG
galvanized steel cap 9-29-25 for review JJG
FINAL GRADE Date Issue Initial
Site Details
ITEM 4 OR CLEAN SUITABLE MATERIAL VARIES
NO LARGE STONES OR 18" MIN
ORGANIC MATTER 12" 12"
4" diameter galvanized steel
Curb & Sholder Detail
3.0'
MIN MIN pipe bollard filled w/ concrete
ITEM 4 OR SUITABLE
POROUS FILL BEDDING
MATERIAL TO TOP OF PIPE
New Sales & Service Building
for
PROPOSED REINFORCED
Leal Peterbilt
CONCRETE DRAINAGE PIPE
70 Roa Hook Road
UNDISTURBED EARTH INSTALLED PER MANUFACTURERS Town of Cortlandt
WRITTEN INSTRUCTIONS 18" diameter concrete Westchester County
2.5'
New York
Lot 1 Block 2 Section 22.20
DRAINAGE PIPE TRENCH N.T.S.
1.5'
Bollard Detail
EXPANSION JOINT 6"
sign per schedule WHEN CURB MEETS
SIDEWALK OR PVMT
1"R
6"
1 % MIN PITCH NY 024343-01 exp 03-31-2027
flanged channel It is a violation of the law for any person, unless
post per NYSDOT acting under the direction of the licensed architect,
to alter any item in the plans, specifications or
reports to which the seal of the architect has been
18" applied in any way. If an item bearing the seal of an
architect is altered, the altering architect shall affix
to this item the seal and the notation "altered by"
followed by the architect's signature and the date of
7'-0"
such alteration and a specific description of the
alteration.
4"
John J Gilchrist
Architect
A Professional Corporation
8"
3/4" CRUSHED STONE
UNDISTURBED EARTH
8 Coach Lane
Upper Saddle River
12" concrete NOTE: New Jersey 07458
footing 36" below
grade - 3,000 psi @
PROVIDE 1/2" EXPANSION JOINT IN CONC CURB EVERY TEN FEET.
CONSTRUCT CURB WITH CLASS A CONCRETE (3000 PSI @ 28 DAYS)
Phone 201 573 1877
28 days JJGAPC@gmail.com
ON-SITE CURB DETAIL N.T.S. NTS
Peterbilt
6 of 7
External Oil Water Separator Traffic Sign Detail 250311
Page 73
16
Septic System & Well 35
15 JOHN J
General Notes 30
17
GILCHRIST
16
existing bollards
15
34
25 13
There shall be no trees within 10 feet of the OWTS 20 IRF 14
ARCHITECT
SoilAir Systems
IRF existing domestic water well
30
There are no wells within 200’ of OWTS unless Model RF-3952TB 1.2'
0.3'
10'
otherwise shown on plan. There are no OWTS junction boxes to controls located within building
underground 2" ASPHALT CONCRETE NYSDOT ITEM 403.16
9' 10'
A Professional Corporation
electric to building
within 200’ of well unless otherwise shown on
plan. underground connection to electric panel
25 166.8 WELL
U 12
22
32.0'
'00"E
05 Soil Investigation
15
N49°
15
12
CC
The proposed OWTS area shall be isolated and PHA
LT
9.0'
17
protected against damage by erosion, storage of 32.0' AS
o well
10
20 TP1
earth or materials, displacement, compaction or 0.7'
CC
Deep Test Pits TP-3 & TP-4 (locations
other adverse physical change in the in from building out to leachfield A
CRW
32.0' TP2
CC
shown on plan)
characteristics of the soil or in the drainage of the
imum t
1.36' RIM:14.41'
IRF B
area. INV A: 12.97' 4"PVC
0"-2" topsoil organic
22.5'
15
13
32.0'
INV B: 11.21' 15"CPP
A
376 sq ft 2"-84" sands & silts
12
If for any reason the approved construction plan
22.0'
72" water encountered
in
RIM: 14.2' SoilAir control panel
34.6'
can not be followed, a revised plan must be
100' m
B INV A: 10.68'
INV B: 10.68' rainwater storage underground electric to SoilAir control 14 no rock
prepared, submitted, and approved by WCDH.
17
15"CPP tank to be abandoned rain water storage tank to be abandoned
CRW
TACK COAT SYSDOT ITEM 407.0101
15 15 Percolation Tests 1 & 2:
SR
The design professional shall supervise the ALT
S27°24'00"E
SPH 1 to 5 minutes per inch
W
23
construction of the OWTS and make an open 1,000 gallon ST-1000 H20 septic tank see detail 4" ASPHALT CONCRETE NYSDOT ITEM 403.13 A
CNC.
W
22.0'
works inspection. minimum 3" bedding layer of sand or pea gravel
U
SR
Hydraulic Loading: 90 gpd
22.0'
4" SUBBASE NYSDOT ITEM 304.05 U U U rain water storage tank to be abandoned
Within 24-hours of the completion of the OWTS, WELL :
Application Rate: 1.2
LET '
CHAMBERS
the design professional must notify the UNDER CHAMBERS
E IN 5 Septic Area 75 sf
ORIGINAL SUB-GRADE TO BE COMPACTED UNDER PIP PP: 12. 18
Westchester County Department of Health 24"C Required length of infiltrators 20', 24'
NOTE 30.1'
(WCDH) that the OWTS is ready for inspection by
U
provided. Existing surface grade in
162.08'
THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ALL ROAD
24"C
submitting a completed request for an open works 20.1' 9.4' area of diffusers is approximately
20
CNC.
COURSES ARE COMPACTED WITH A TEN TON ROLLER AND MEET THE
22.0'
inspection on the appropriate form to WCDH. ROOF 2.5%
PP
FOLLOWING DOT COMPACTION STANDARDS: 4" SDR35 PVC sewer DRAIN
22.0'
15
(TYPICAL) Property is in the Hudson Watershed
That no backfilling of a completed OWTS can SUBBASE COMPACTION: ITEM 203-3.12
Basin
20
4.0'
16
ASPHALT COMPACTION: ITEM 401-3.12
7.0'1.1'
occur until after it has been inspected and SoilAir Systems CNC.
CNC.
accepted by the Westchester County Department Model1 STORY
RF-3952TB There are no existing or WCDH
15
CO U U U U U
of Health. The diffusers shall be installed just STRUCTURE #70 CNC.
air pump & controls
approved wells or OWTS within 200
ON-SITE PAVEMENT SECTION
18.6'
U
21.0'
before the final asphalt top course is ready to be 25
feet of the proposed OWTS or well.
placed in the parking and drive areas (ie all
22.0'
12.9'
4.0'
34.1' TP4
pavement areas). No vehicular traffic shall be A U 15 four
15 low boy settling tanks w/ wiers
underground air line TP3
allowed to traverse within 3ft of the perimeter of RIM: 14.10' wash water recycling system to be abandoned
20
20
B
INV A: 10.26' U U 3,356 sq ft PT2 ASPHALT
the 48 ft by 4ft present and future area where the
22.0'
4.0'
10.8'
INV B: 10.26' U
PT1
17
diffusers are to be located anytime during
15"CPP
13.5' 8.0' 8.0'
construction until this area has been backfilled and CHAMBERS SB SSB
B Current Property Owner:
18
UNDER
the final asphalt top course has been placed over CRW
U
10.0' 6.0' 5.0' 24.0'
AREA=28060.8445±SQ.FT.
20.0' Valerio Santucci
this area. This area will be isolated with traffic
22.0'
Roof Rebar:
15 ACRES=0.6442±
14
future leach field 4' x 20' 14 37 Croton Dam Road
barrels as directed by the engineer and shall
Ossining NY 10562
Top layer (2" cover) U
#4 Bar @ 12" oc both ways TAX#22.20-2-1
remain in place until the final asphaltic surface is existing leach field 4' x 20' top of chamber el 14.25
CNC.
CNC.
E
4"
15
Bottom layer (1" cover)
info@VSConstructionCorp.com
0.2' 2 STORY
12" of 1" crushed stone under CC
installed.
N27°24'00"W
#5 Bar @ 12" oc long way,
2
50'
Top View #5 at 6"oc short way
chambers & along the sides U deep test pits witnessed by
13
'
0 '
SRW
of the chambers not shown
representative of WCDOH
°1 .89
m
The installation of the OWTS shall be in 2
N2 60
existing 1,000 gallon septic tank NYS DISK
in t
33-1/2" 60" 35-1/2"
1,290 sq ft
accordance with the Rules and Regulations for the FOUND 10
os
Design and Construction of Residential
(4)4 ton anchors in roof 2,865 sq ft
22.0'
CC
(2) 24" Covers 12 12
tor
Subsurface Sewage Treatment Systems and
15 190.08'
ND
FOU .
Drilled Wells in Westchester County, NY. PIPE PROP
mw
N
ASPHALT IRO NE OF LT revised per review
14 '
0.66 NER PHA :
IIRF
RF F AS LET 3–25-26 JJG
OUT 2'
4"
60" 71"
ate
All pipes connecting to tank and boxes shall be cut Inlet
COR
EDG
EO E
PIP PP: 9.
letters
4.5'
IIPF
flush with the inside wall of box. PF 24"C
r in
CC
10
1–22-26 for review JJG
(4)4 ton anchors in floor
162 sq ft 10
let
TRAVELED
CC
The proposed OWTS shall be installed by a
22.0'
38" 77"
Pictorial View 13 RIM: 11.77' SRW GRAVEL
9-29-25 for review
Westchester County licensed septic contractor. WAY RIM: 13.73' INV A: 7.33' 15"CPP RIM: 9.35' JJG
12.0'
35-1/2" 60" 33-1/2" A INV A: 9.45' INV B: 9.17' 4"PVC INV: 7.58' CC
INV B: 9.35' CC
INC C: 7.2' 15"CPP 15"CPP
Date Issue Initial
4"
Prior to any excavation all underground utilities Outlet
B
15"CPP
CC C
B
A
must be located. Call 1-800-962-7962. outlet tee w/ effluent filter &
129"
Side View B4 ' * + +0 5 - CC
float control per SoilAir detail W
'24"
8" GRAVEL
The Westchester County Health Department °07 New Septic System
1 C +0 3 3 3 1 - + / A new 100 Year Flood Line
provide side discharge opening B
3 CC
34
1S
approval expires one year from the date on the Elev. 10.5 NGVD 1929
LIN SB
D
> &! - ,1$ 10 E
manufacturer to increase RIM: 13.51'
8'
12.7
INV A: 6.21' C G
approval stamp and is required to be renewed on 1 FO 8
NB
top of chamber thickness
13 INV B: 6.21'
W
or before the expiration date. The approval is RO
Concrete: 4"
Bottom = 2.2 yards 4" Inlet 3@ ; by 2" due to shallow cover >- + = > INC C: 6.0'
revocable for cause or may be amended or 15"CPP
Outlet
weight = 9,000 lbs
0' 10
modified when considered necessary by the 21" 16. B
100 YearSFlood Line
Top = 2.8 yards Septic = 18"
4"
"W
&/!A A
department. weight = 11,000 lbs
NB
Grease = 24" A
57"
2 '22 Elev 10.5 NGVD 1929
4°5
!A 12
(Elev 9.5 NAVD)
There are no unprotected sources of S3
38" B
New Sales & Service Building
35" 10"
40" 43" A
IRON ROD
contamination within 200 feet of the proposed well. $? ?? ? ??
'
20" FOUND ON
.20 for
PROP. CORNER IPF 63 NB
Leal Peterbilt
4"
The minimum well yield is 5 gpm; yields less than W
RO
5" 5-1/2" ? ??
5 gpm must be immediately reported to the &' ) ?? 1'-9" RIM: 9.59'
A D
11
? (??
8
RO
INV A: 5.72' 15"CPP
department. INV B: 5.44' 24"RCP
70 Roa Hook Road
OK
Wall & Floor Rebar: IRF
NB
#4 Bar, 12" oc both ways
O
#? ?? IRF
Town of Cortlandt
' 2;Important Note: Inlet and outlet baffles are not
SB H GE
5
with 3" cover
included and must be added after installation. + , +
Use sanitary tee with pipe extension to depth
A RID
RO Westchester County
as shown. minimum 3" bedding layer of sand or pea gravel 12" of 1" crushed stone under
LT B
LE
& along sides of chambers
$?? HA
CC
FA
SP
9 S V I L New York
SPECIFICATIONS ST-1000 H20 GE
O
U TE NN
2
Lot 1 Block 2 Section 22.20
1'-9" LT ED
SB O -A
A R LL
1,000 GALLON SEPTIC TANK
? (??
H US KSKI
' ) ??
Concrete Min. Strength: 4,000 psi at 28 days P
AS TRY
OR GREASE TRAP
E 0)
PE . 185
Reinforcement: #4 & #5 Rebar / ASTM A615
Air Entrainment: 6% + @ ; EN Y H
(S.
@ ;
WA
+ 0- 4 - + 33
Construction Joint: Butyl Rubber Sealant Woodard's Concrete Products, Inc.
629 Lybolt Road, Bullville, NY 10915 12" of 1" crushed stone under 12" of 1" crushed stone under
Pipe Connection: Polylok Seal & along sides of chambers & along sides of chambers
10
(845) 361-3471 / Fax 361-1050
Weight = 20,000 lbs
Load Rating: HS20-44 + 30% / ASTM C857 NB PLAN
4/29/14
NORTH
www.woodardsconcrete.com
+,- . +/ - +0 12 $ 34 # 4 !"#$ % & L INE 5
Septic Plan
+5 -, 6 + 2 7$ -) . ! SB NB FO
G
Scale: 1" = 20.0'
6" asphalt pavement
- + - +6 + 2 !8
E
EK
4" schedule 40 perforated PVC pipe
3 , 9 & 0 +4 : 01 9 ! 4 LIN ! 0 10' 20' 40'
6" base course ; - 9 $ 4< - 5 G
* &FO' !
C RE
SB
ILLE
+02 = ) . #!(
"#$!% & '&$( )
Prepared with information taken from
C. 0 > ) ) $
SE V "Property Survey & Topography 70 Roa Hook
O N
B
A N N Rd (US RT 9) Cortlandt Manor, New York
2"
C R Prepared for Steven Auth" by Rowan Land
;;;/; CU /, 6
- 4, +,- NB
Surveying, PLLC dated October 14, 2017
1'-6"
4"
AL
MET D
NB A R
GU
L
I
NY 024343-01 exp 03-31-2027
6"
R A
IL
RA It is a violation of the law for any person, unless
RD
acting under the direction of the licensed architect,
A to alter any item in the plans, specifications or
L GU reports to which the seal of the architect has been
2'-0"
3/4" crushed stone E TA applied in any way. If an item bearing the seal of an
M architect is altered, the altering architect shall affix
to this item the seal and the notation "altered by"
followed by the architect's signature and the date of
Service Line to Septic Tank such alteration and a specific description of the
alteration.
Well Detail invert @ building 14.03
invert into chamber 13.46
SoilAir air line in
John J Gilchrist
invert out 13.58
Architect
6" pavement
20 lf 4" SDR35 PVC @ 1% invert in 13.83 15.05 precast leaching chambers 3@ 8'
sub base thickness varies top of chamber 14.25 6" pavement PQ
3 1/2"
bottom of chamber 12.50 14.75 1'-0" 4'-0" 1'-0"
existing grade
A Professional Corporation
6"
8"
6"
14.75
8 Coach Lane
1'-9"
1'-9"
Upper Saddle River
4'-9"
3'-9"
1'-0"
New Jersey 07458
3'-0" 1'-0"
Phone 201 573 1877
3'-0"
4"
10'-0" 5'-11" 4'-1" 8'-0" 8'-0" 8'-0" 1'-0"
JJGAPC@gmail.com
Peterbilt
1" = 20.0'
minimum to building 12" of 1" crushed stone under chambers
12" of 1" crushed stone under chambers 36" minimum native silty sand treatment area water table 8.5 & along the sides of the chambers
7 of 7
Model LB-1,000 septic tank see detail Sources: Esri, HERE, DeLorme, Intermap, increment P Corp.,
Site Location Plan
top of tank 15.00 minimum 3" bedding layer of sand or pea gravel GEBCO, USGS, FAO , NPS , NRCAN, G eoBase, IGN, Kadaster NL,
250311
Ordnance S urvey, Esri Japan, METI, Esri China (Hong Kong),
Septic System Profile
swisstopo, MapmyIndia, © O penS treetMap contributors, and the GIS
User Community
SCALE: 1/4" = 1'-0"
Page 74
Page 75
March 25, 2026
Hon. Steven Kessler
Chairman of the Town of Cortlandt Planning Board
and Members of the Planning Board
1 Heady Street
Cortlandt Manor, New York 10567
Re: VS Construction Corp. – Evergreen Manor Parcel 3 – Pharmacy & Medical Office
2003 Crompond Road
Dear Chairman Kessler and Members of the Planning Board:
On behalf of VS Construction Corp, owner of the above-referenced Property, we hereby submit the
enclosed updated drawing set and offer the following responses to comments received from
Department of Planning & Community Development, dated March 5, 2026.
Additional Information Required
1. Comment: Subdivision: The applicant shall explain to the Planning Board how they
intend to proceed with the additional required subdivision of Lot 2 (to create
lots for the townhomes and this commercial building) since the Planning
Board cannot grant final site plan approval without completion of those
subdivisions. Related to the creation of a separate lot for this commercial
building, the size of the parcel proposed for the 9,600 sq. ft. building shall be
added to the plan based on a metes and bounds survey of the lot, and all
dimensions of each proposed front, side and rear lot line shall be shown on the
subject drawing.
Response: The Applicant is currently working with the Town’s Department of Technical
Services related to the Westchester County Department of Health review of
the conditionally approved two-lot subdivision to create the planned Assisted
Living Facility parcel (Parcel 1). The Applicant will file a separate subdivision
application to amend the conditionally approved two-lot subdivision to create
parcels for the planned residential townhome development (Parcel 2) and the
Page 76
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 2
subject commercial building (Parcel 3) so that site plan approval can be
granted for each, as noted.
2. Comment: Site Circulation: There does not appear to be enough space for a large truck to
turn/maneuver on the site. A site circulation plan with turning templates for
emergency vehicles shall be provided that illustrates how vehicles, particularly
fire, garbage and delivery trucks, will maneuver around the site. This parcel is
within the Lake Mohegan Fire District; the applicant should reach out
directly to the fire district to determine which apparatus is likely to be the
largest one to respond to a call at this site.
Response: The enclosed site plan drawing set includes vehicle maneuvering plans
illustrating that a front-loading refuse truck (see SP-12.1) and an SU-30
delivery truck (see SP-12.2) can access the site from the main access road and
turn around within the commercial parcel to exit. Drawing SP-12.0 is also
included showing that the Lake Mohegan aerial fire truck will be able to
maneuver through the site. Emergency vehicles can enter and exit the site
from either the main access road or through an emergency driveway to/from
Lafayette Avenue. Based on discussions with building and fire officials the
emergency driveway will provide a twenty-foot-wide stabilized access/egress
route constructed with a mix of asphalt paving and stabilized shoulders. The
entry/exit through the emergency access driveway will be limited to
emergency service vehicles only and will be secured with a siren-operated gate
control.
3. Comment: Lighting: All proposed outdoor lighting shall comply with the Town’s Outdoor
Lighting Standards (§307- 12.3). Per §307-12.3-E, the applicant shall
provide a separate photometric plan and luminaire schedule. Complete
manufacturer’s cut sheets of each fixture shall also be provided, including
details on which fixture specifications are proposed for this project. Per §307-
12.3-F-2(c), fixtures located near wooded or natural areas shall have a CCT
of no higher than 2200K and a backlighting rating of zero.
Response: A Site Lighting Plan (SP-5.1) with photometrics and lighting schedule, and
Site Lighting Details (SP-5.2) with cut sheets have been added to the plan
set. The post top mounted fixtures along the access driveway adjacent to the
existing wetland to remain will feature amber lighting (see specifications on
Page 77
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 3
SP-5.2). The LED is mounted within the top of the fixture without any up-
light, instead of within a globe.
4. Comment: Wetland and Buffer Impacts: The proposed building and associated parking
as designed would require disturbance to a wetland and wetland buffer for the
access drive and parking area. Wetland disturbance and wetland buffer
disturbance were analyzed by the Town Board as part of their review of the
overall MOD and specific findings were made that there would be no
significant adverse environmental impacts related to surface water and
wetlands. Confirmation of wetland disturbance and mitigation measures
must be finalized by the Planning Board as part of their review of this
application. The applicant shall confirm for the Planning Board that the
amount of wetland and wetland buffer disturbance is not greater that what
was analyzed in the findings statement. Per §179 of the Town code a permit
for disturbance to the wetland and wetland buffer is required to be issued by
the Planning Board. The applicant shall quantify the amount of direct
wetland and wetland buffer disturbance proposed as part of this commercial
building project. Consideration should be given to reducing impacts to
wetlands and wetland buffer where possible. Wetland mitigation areas for the
proposed wetland disturbance, specifically associated with this phase of
development, must be shown on the overall site plan.
Response: The wetland and wetland buffer disturbances that would result from the
construction of the Parcel 3 driveway and parking lot are consistent with the
disturbances evaluated during the SEQR review process. The plan studied
during the SEQR review would have resulted in approximately 6,500 square
feet of wetland disturbance and 23,000 square feet of wetland buffer
disturbance. The current site plan would result in a wetland disturbance of
approximately 6,000 and a wetland buffer disturbance of 19,000. The
Applicant will set up a meeting with Town staff to discuss the
implementation of the wetland mitigation plan.
5. Comment: Tree Inventory: The applicant is advised that as per Chapter 283 (Trees) of the
Town Code, all trees located within 50 feet of any proposed disturbance must
be field located and inventoried and a report as to the tree size, species and
health must be submitted. The inventory can be submitted by the applicant
Page 78
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 4
but must be reviewed by a Town-approved arborist. The Planning Board will
make a determination on the granting of the tree removal permit as per
Section 283-7 of the Town Code.
Response: A tree inventory by a Town-approved arborist is currently being coordinated
with planning staff and will be submitted to the Planning Board upon
completion.
6. Comment: Landscaping: The Conceptual Landscape Plan (sheet SP-4.1) shows plant
categories, notes the total number of plants proposed in each category, and lists
specific plants that may be selected for that category. However, a precise list
and corresponding key to the landscape plan is not shown. A standard
planting schedule is required and shall include the name, quantity, and size
at planting of each plant material selected, along with a plant-specific key to
the landscape plan. The applicant shall note the Town’s preference for
native/indigenous plant materials wherever possible.
Response: The Site Landscape Plan (SP-4.1) has been updated to provide a plant
schedule with a name, quantity and size corresponding to the plan labels. The
majority of the proposed plant material is native to the northeast United
States.
7. Comment: Walls/Fencing: Renderings and details of the wall and fence along the access
drive shall be included with the site plan set.
Response: Representative details of the proposed retaining wall supporting the Parcel 3
access driveway have been added to the plan set (see Drawings SP-6.4 and
SP-6.5). Drawing SP-6.4 also includes an elevation view of the wall as would
be seen from standing within the adjacent Crompond Road wetland area.
There will be a black vinyl chain link fence at the top of the wall for fall
protection as required by code. The wall will be located between
approximately 150 feet to over 250 feet from the edge of Crompond Road,
with intervening trees within the wetland area that will remain
8. Comment: Signage: Dimensioned graphics and all associated details shall be provided for
all exterior signs associated with this commercial site, including the wall-
mounted sign shown on the architectural elevations.
Page 79
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 5
Response: The proposed conceptual signage locations are shown on the enclosed
elevation drawing and a dimension of the blade sign has been added. The
Applicant will continue to refine the proposed signage to provide additional
dimensions and details consistent with Town Code Chapter 245 Signs and
Zoning Ordinance section 307-96.2C(7)(b) Medical-Oriented District
guidelines for the Town’s review once specific tenants are identified.
Site Design
9. Comment: The proposed retaining wall at the rear of the building sits on the 30-foot non-
disturbance line with the adjacent residential parcel, and it appears
construction (clearing and grading) for the retaining wall behind the
building would result in encroachments into the 30-foot non-disturbance
area. Per §307- 96.2. C(5)(a) and (b) “the non-disturbance area shall not be
varied or modified by the Zoning Board of Appeals or the Planning Board.”
Response: The building and retaining wall have been shifted forward to provide
additional space between the proposed building and associated retaining wall
and the 30-foot non-disturbance area to allow for construction.
10. Comment: The applicant should consider reducing the building footprint to allow for
better site design, circulation, and overall functional safety. Under the present
layout, it appears trucks would have difficulty maneuvering around the site. A
reduction in the building footprint could also reduce impacts to
wetlands/wetland buffers and alleviate the likely encroachment into the 30’
non-disturbance area.
Response: The site layout has been adjusted to improve vehicular circulation and
provide additional separation between the proposed development and the 30-
foot non-disturbance area. Refer to the Site Layout Plan, Drawing SP-1.0
and the included vehicle maneuvering plans for refuse trucks, delivery trucks,
and emergency vehicles (see Drawings SP-12.0 through SP-12.2).
11. Comment: The proposed location of the refuse container would not be easily accessible for a
garbage truck and should be relocated. It appears that the proposed location of
the refuse container would require a truck to back in from the access drive.
Further, the proposed location at the rear of the parking lot would not be
Page 80
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 6
accessible if there are vehicles parked in the adjacent parking spaces. The
applicant shall relocate the refuse container to an area that eliminates such
conflicts and allows a garbage truck to access the dumpster and easily
maneuver around the site. In addition, per §154 of the Town code, the
dumpster area shall include a properly designed enclosure, and details of the
enclosure shall be provided by the applicant.
Response: The enclosed updated site plan drawing set includes vehicle maneuvering
plans illustrating that a front-loading refuse truck (see SP-12.1) can access the
refuse enclosure and turn around within the identified Service and Delivery
Loading Area identified on the plans. The refuse enclosure area will be
surrounded by a 6’ high black vinyl chain link fence with privacy slats.
12. Comment: A loading zone for delivery vehicles should be shown on the site plan.
Response: A Service and Delivery Loading Area is shown on the Site Layout Plan,
Drawing SP-1.0 (see hatched area at the western end of the parking lot on
the enclosed site plan).
13. Comment: The purpose of the hatched area located immediately south of the emergency
access drive should be noted on the plan.
Response: The hatched area is a proposed Service and Delivery Loading Area. This area
has been relocated and expanded from the last submission to provide for
more efficient vehicle maneuvering. The area is designed to serve as both a
turnaround area for both the refuse truck and delivery vehicles as well as
providing for the temporary parking of delivery vehicles during unloading
activities.
14. Comment: The subject drawing shows an “asphalt path” located along the access road to
the commercial parcel. Planning staff recommends that this be a concrete
sidewalk.
Response: The Site Layout Plan (SP-1.0) has been updated to note a concrete sidewalk.
Page 81
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 7
Architecture
15. Comment: As mentioned above, the applicant should consider reducing the building
footprint. A 2-story alternative was mentioned previously by the applicant;
that may present the best building solution for this tight site.
Response: The Applicant has since determined the proposed retail pharmacy use is not
conducive to a two-story operation/design and that a one-story structure is
better suited for the proposed mixed-use development consisting of retail use
(8,000 square feet) and limited amount of medical office space (1,600 square
feet).
16. Comment: The applicant shall provide a perspective view into the site from the vantage
point of someone heading east on Route 202 in the vicinity of the intersection
with Lafayette, to show how people will actually see the commercial site whether
they’re on foot or in a passing vehicle.
Response: The Applicant is preparing a perspective view and will submit it in advance of
the upcoming Planning Board meeting and have it available for presentation.
Site cross sections showing the relationship of the proposed structure from
both Crompond Road and Lafayette Avenue have been added to the drawing
set (See Drawing SP-2.2).
17. Comment: The applicant shall provide floor plans that demonstrate how the interior space
will be used; this will help inform expected parking needs. Floor plans shall be
provided showing any basement, if proposed. All means of ingress and egress to
the building shall be shown as well as all required accessible paths.
Response: A preliminary floor plan is enclosed (see Architectural Drawing 03A)
showing the proposed retail and medical office spaces. No basement is
proposed. Ingress and egress from the building will be via a 6-foot-wide walk
surrounding the building. Accessible routes to both uses will be via this walk
and the surrounding parking area servicing the building.
Page 82
Chairman Kessler and Members of the Planning Board March 25, 2026
Re: Evergreen Manor Parcel 3 Page 8
We look forward to continuing the review of this application with the Planning Board.
Very truly yours,
DTS PROVIDENT DESIGN ENGINEERING, LLP
Matthew N. Steinberg, AICP
Senior Associate
Enclosure(s)
cc: VS Construction, Zarin & Steinmetz, BHC Architects
Page 83
2026.03.25
11'-7"
11'-7"
Page 84
Page 85
2003 Crompond Road
(TAX LOT: 33.12-2-7, 33.12-2-1)
Town of Cortlandt, New York
Site Plan Application - Parcel 3
January 21, 2026
February 18, 2026
March 25, 2026
LOCATION MAP ZONING TABLE LIST OF DRAWINGS
REQUIRED/
PROPOSED No. Name By Scale Date
Code Section MEDICAL ORIENTED DISTRICT (MOD)
PERMITTED Lot 3 Evergreen Manor COVER SHEET DTSP 03/25/26
307-96.2 Medical Oriented District (MOD) SP-1.0 SITE LAYOUT PLAN DTSP 1" = 30' 03/25/26
C(1)(a) Dimensional Requirements
Minimum lot area (SF)
(1)
100,000 N/A 1,235,294
SP-2.0 SITE GRADING AND DRAINAGE PLAN DTSP 1" = 30' 03/25/26
Minimum lot width (ft) 100 167 -- SP-2.1 CROSS SECTION DTSP AS NOTED 03/25/26
Setbacks
Front (ft) SP-2.2 CROSS SECTIONS DTSP AS NOTED 03/25/26
Crompond Road (Route 35/202) 30 89.3 -- SP-3.0 SITE UTILITY PLAN DTSP 1" = 30' 03/25/26
Lafayette Avenue 30 119.9 --
Side (ft) Crompond Road (Route 35/202) 30 N/A -- SP-4.1 SITE LANDSCAPE PLAN DTSP 1" = 30' 03/25/26
Side (ft) Lafayette Avenue 30 N/A
Rear (ft) 30 35.3 --
SP-4.2 LANDSCAPE DETAILS DTSP AS NOTED 03/25/26
Maximum Lot Coverage (%) (2)
60 N/A 36% (3) SP-5.1 SITE LIGHTING PLAN DTSP 1" = 30' 03/25/26
Height (ft) 45 20.5 --
C(3)(b) Parking Requirement SP-5.2 SITE LIGHTING DETAILS DTSP AS NOTED 03/25/26
Pharmacy (not accesory to hospital) - 1 space for every 250 square feet 32 (for 8,000 sf) 32 -- SP-6.1 SITE AND UTILITY DETAILS DTSP AS NOTED 03/25/26
Office Medical - 1 space for every 150 square feet 11 (for 1,600 sf) 11 --
Total 43 43 SP-6.2 SITE DETAILS DTSP AS NOTED 03/25/26
Minimum Area of Nondisturbance (ft)
C(5)(a)
Minimum from nearest lot line of a parcel on Cypress Lane, Nancy Lane, Ridge SP-6.3 SITE DETAILS DTSP AS NOTED 03/25/26
100 538 100
Road, Tamarack Drive SP-6.4 SITE DETAILS DTSP AS NOTED 03/25/26
Minimum from nearest lot line of a parcel on any other adjacent street with
an existing residential unit
30 35.3 30
SP-6.5 SITE DETAILS DTSP AS NOTED 03/25/26
SP-12.0 EMERGENCY SERVICE VEHICLE MANEUVERING PLAN DTSP 1" = 30' 03/25/26
(1) Per § 307-96.2C(4)(a) The creation of internal property subdivisions within a mixed-use development is permitted to allow for multiple ownership of SP-12.1 FRONT LOADER GARBAGE TRUCK MANEUVERING PLAN DTSP 1" = 30' 03/25/26
properties/uses. Any eligible site hereunder may, for purposes of dedication, the creation of rights-of-way, sale, lease, mortgage, or other disposition or
financing, be subdivided or re-subdivided, converted to condominium or cooperative ownership, or otherwise divided into lots, parcels or tracts, which SP-12.2 DELIVERY TRUCK MANEUVERING PLAN DTSP 1" = 30' 03/25/26
may be sold, leased, mortgaged, or otherwise alienated or encumbered, without regard to minimum lot area provided that at least one development
from the original lot prior to subdivision is developed as a medical use.
(2) Per § 307-96.2C(4)(b) If a site meets the eligibility requirements above, then all determinations relating to lot coverage and building coverage for any lot
LEGEND
or lots subject to internal property subdivision hereunder shall be made treating the entire site as a single unit; provided, however, that access and DTSP DTS PROVIDENT DESIGN ENGINEERING, LLP
infrastructure shall be shared by any lot approved under this section. Reciprocal easements and/or agreements that address common access, shared TCM DANIEL T. MERRITTS, PLS
parking, stormwater systems, and utilities shall be developed to ensure the future operation and maintenance of the infrastructure servicing any lot or
lots approved hereunder.
BASE MAP SOURCE: WESTCHESTER GIS (3) Lot coverage calculated based on Site Development Plan applications for Lot 1 (assisted living residence) and Lot 3 (commercial) and master plan for Lot 2
(townhouses)
NOTE:
THERE SHALL BE NO DEVIATION OF THE APPROVED PLANS WITHOUT PRIOR
WRITTEN AUTHORIZATION BY THE DIRECTOR OF TECHNICAL SERVICES OR
OTHER AUTHORIZED INDIVIDUALS FAILURE TO COMPLY WILL BE GROUNDS
FOR THE ISSUANCE OF A "STOP WORK ORDER"
OWNER / APPLICANT PLANNER & CIVIL ENGINEER ARCHITECT LAND USE ATTORNEY SURVEYOR
V.S. CONSTRUCTION CORPORATION BEATTY HARVEY COCO ARCHITECTS ZARIN & STEINMETZ DANIEL T. MERRITTS, PLS
37 CROTON DAM ROAD DTS PROVIDENT
1300 WALT WHITMAN ROAD 81 MAIN STREET 394 BEDFORD ROAD
OSSINING, NY 10562 Intelligent Land Use MELVILLE, NY 11747 WHITE PLAINS, NY 10601 PLEASANTVILLE, NY 10570
DTSProvidentDesignEngineering,LLP
OneNorthBroadway
WhitePlains,NY10601
P:914.428.0010
F:914.428.0017
Page 86
EVERGREEN MANOR
Town of Cortlandt, New York
OWNER / APPLICANT
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
OSSINING, NY 10562
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
R-40
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
WHITE PLAINS, NY 10601
SURVEYOR
DANIEL T. MERRITTS, PLS
394 BEDFORD ROAD
PLEASANTVILLE, NY 10570
WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
PROPERTY LINE,
TYP. 10 NORTH STREET
COLD SPRING, NY 10516
6 FT. HIGH SOLID VINYL FENCE
PARCEL 2 ON TOP OF RETAINING WALL
PROPOSED RETAINING WALL, TYP.
PROPERTY LINE,
(TYP.)
ASPHALT PAVEMENT (TYP.) 30' SIDE YARD SETBACK/
CONCRETE CURB (TYP.) NONDISTURBANCE AREA
Λ Λ
CONCRETE WALK Λ
Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ
PROPERTY LINE
Λ Λ Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ Λ
ELECTRIC VEHICLE
Λ
22.0'
Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ
PARKING (TYP. OF 2)
Λ Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
ACCESS DR
Λ
Λ
Λ Λ Λ Λ
IVE
Λ Λ Λ Λ Λ
Λ Λ
DUMPSTER
Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ
CONCRETE
Λ
(1,60 OFFICE
Λ Λ
Λ
Λ
ENCLOSURE
Λ
PARCEL 2
Λ
Λ
Λ
Λ Λ
Λ Λ Λ
7 WALK
Λ Λ
Λ Λ Λ Λ
Λ
Λ
0 SF)
Λ
6.0 '
Λ Λ Λ
EV
Λ
MOUNTABLE CURB
Λ Λ
TYP.
Λ Λ Λ Λ
WOODEN GUARDRAIL
Λ
Λ
Λ
7
'
Λ Λ
ICAL
68.9
Λ Λ Λ
Λ Λ
25.0
Λ Λ
Λ
EV
Λ Λ
Λ
'
Λ Λ Λ
Λ
PROPOSED 1-STORY BUILDING
Λ
Λ Λ
MED
Λ Λ
Λ
Λ Λ Λ
E
Λ Λ
Λ Λ
EXTEND EXISTING WALL
ENU
Λ
Λ
Λ
RETAIL (8,000 SF)
Λ Λ Λ
Λ Λ
Λ Λ Λ
Λ Λ
Λ
Λ Λ
4FT HEIGHT FENCE
E AV
Λ Λ Λ Λ
FLAGGED WETLAND BOUNDARY,
Λ Λ Λ
Λ
Λ
Λ Λ Λ Λ
Λ
TYP. 18.0
Λ Λ
STABILIZED TURF
Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
Λ
YETT
Λ Λ
Λ
' PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
Λ Λ Λ
Λ
1-800-962-7962 OR 811
Λ
FLUS
Λ Λ
Λ
Λ Λ
CUR H
Λ
LAFA
Λ
Λ
Λ
Λ
6.0'
B
FLA
Λ
Λ
Λ
Λ
WE
Λ
'
27.0
Λ
Λ
6.0'
G ABE AGG
TYP.
Λ
FC
Λ
T
Λ
R10.0 '
0'
3 Λ
25'
Λ
L
Λ
Λ
G
Λ
FC
18.
Λ Λ
A
Λ
Λ Λ
Λ
L S FL
PAVEMENT
ED J LLA
Λ
Λ
9.0 '
ND
Λ
12'
Λ
Λ
STRIPING (TYP.)
Λ
'
Λ
20.0
Λ
X
Λ
Λ
Λ
5
Λ
43 SPACES
Λ
U
Λ
Λ
PARCEL 1
X
Λ
EMERGENCY ACCESS GATE NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
L
Λ
Λ
Λ
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
WITH HORN ACTIVATED
Y
Λ
119
X
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
.9 ' ' OPENER AND NO PARKING ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
Λ
14
0.0
Λ
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
R1 SIGN BOTH SIDES WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
Λ
Λ
,
100' WETLAND
Λ
2
MOUNTABLE CURB WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
E
BUFFER, TYP.
Λ
025
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Λ
D
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
EMERGENCY ACCESS
Λ
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
89.3 '
Λ
BY
Λ
PROPERTY LINE (ASPHALT PAVEMENT) SHOWN BY THESE DRAWINGS.
Λ
Λ
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
Λ
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Λ
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
Λ
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Λ
Λ
Λ
30' FRONT YARD SETBACK PARCEL 3
Λ
Copyright DTS Provident Design Engineering, LLP 2025
Λ
All rights reserved.
Λ
Λ
NOT FOR CONSTRUCTION
Λ
30' FRONT YARD SETBACK SERVICE & DELIVERY
Λ
LOADING AREA
Λ
Λ
Λ
Λ
Λ
1 01/21/2026 SITE PLAN APPLICATION
Λ
Λ
Λ
Λ
2 02/18/2026 ISSUE TO PLANNING BOARD
Λ
Λ
4
Λ
Λ
1 03/25/2026 ISSUE TO PLANNING BOARD
Λ
Λ 3
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Co
MOD
n
Λ
c rete
Λ
Pad
Λ
AD
RO
Λ
D 02
ON
MP E 35/2
Λ
O
CR OUT
R
Λ
PARCEL 3 -
Λ
Λ
SITE LAYOUT PLAN
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
SP-1.0
CONKLIN
AVENUE
PROPERTY LINE
(TYP.)
Page 87
S
0" E
N 18° 07' 0
40 8
NEW FIRE HYDRANT
AND FUTURE WATER
MAIN EXTENSION, TYP.
8" DIP, CL 54
39
(CAP END)
6
EVERGREEN MANOR
39
2
Town of Cortlandt, New York
WET
LAN
DB
UFF FUTURE SANITARY SEWER
ER MAIN EXTENSION, TYP.
8" DIP, SDR-35
(CAP END)
MATCHLINE (SEE SHEET SP-2.1)
FUTURE
394
MAIN SANITARY SEWER OWNER / APPLICANT
EXTENSION 00 4 V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
8 OSSINING, NY 10562
39
NEW 8"
GATE VALVE, TYP. PLANNER, CIVIL ENGINEER, LANDSCAPE
S ARCHITECT
400
DTS P O DENT
430.41'
ntelligent Land se
400
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
390
100' WETLAN
White Plains, NY 10601
P: 914.428.0010
F: 914.428.0017
388 ARCHITECT - PARCEL 3
38
8
388 BEATTY HARVEY COCO ARCHITECTS
D BUFFER
382 1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
396
396 1+00386 1+55 LAND USE ATTORNEY
394
ZARIN & STEINMETZ
81 MAIN STREET
WHITE PLAINS, NY 10601
FUTURE WATER MAIN
EXTENSION SURVEYOR
FUTURE SANITARY SEWER DANIEL T. MERRITTS, PLS
S
MAIN EXTENSION 394 BEDFORD ROAD
LAF
PLEASANTVILLE, NY 10570
WETLAND CONSULTANT
A
TIM MILLER ASSOCIATES, INC.
Y
10 NORTH STREET
' 00" E
80.44'
S 68° 33' 00" E
E
37.31' COLD SPRING, NY 10516
0
0+0
T
PROPERTY LINE,
N 19° 38
TYP.
T
390
R-40
AVE E
N
PROPERTY LINE,
U
(TYP.) N 60
E
° 49
' 00
386 "W 30' SIDE YARD SETBACK/
TW 384.0 NONDISTURBANCE AREA
BW 371.8 160
37 .05'
3766..275 TC
Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ
5
Λ Λ
+ BC
Λ Λ Λ
RW-BEND
Λ Λ
38
Λ Λ Λ
TW 380.7
Λ Λ
4
Λ Λ Λ
TW 382.5
Λ
Λ
Λ
Λ Λ
384
Λ
BW 366.0
Λ
402
Λ Λ
RW-BEND
Λ
Λ
BW 368.5
400
S Λ Λ
Λ
Λ
Λ Λ
376.75 TC
Λ Λ
TW 382.5
382
Λ
378
Λ Λ
376.25 BC
Pitch
Λ
Λ
Λ
380
Λ
+ N5
Λ
BW 370.0
376
Λ
5°
Λ
+34900.0Tw
TW 390.0
Λ
w
14
376
Λ
Λ
' 20
Λ
Λ
Λ
382
376
Λ Λ Λ
2.5B
h
BW 374.0
Λ Λ
tc
Λ
"W
Λ Λ
Λ
Pi
Λ
8
Λ
Λ
Λ Λ
375.5 TC
Λ
36
Λ Λ Λ
Λ
378
Λ
375.0 BC
Λ Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ
+
Λ
Λ
Λ Λ
38 7
Λ
400
Λ Λ Λ
0
Λ
Λ Λ Λ
Λ
Λ Λ Λ
8
Λ Λ
Λ
Λ
7
Λ
37
Λ Λ Λ
Λ
Λ Λ Λ
16
Λ
384.67 TC N2
Λ
+33892.0Tw
9.9
Λ
w
Λ
TW 380.0
Λ
Λ
2'
9° 0
Λ
Λ
383.97 BC
Λ
TW 376.0
UPo
6
5.0B
E
Λ
5 BW 370.0
Λ
ENU
Λ
37
6' 1
Λ
Λ
Λ Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
BW 363.0
Λ
Λ Λ
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
le
S
9
Λ
Λ
Λ
1-800-962-7962 OR 811
Λ
34. " E
E AV
TW 379.0
Λ Λ
FINIS
Λ Λ
3
Λ
Λ Λ
HED
0
BW 369.0
Λ Λ
65'
38
376.5
FLOO
YETT
Λ Λ
Λ
+ TW 375.0
Λ Λ
375.0 +
3
R: 37
Λ
37855..5Tw+ 37
Λ
TW 377.5
Λ
8
+ 3756..725 TC
Λ
7.0 BW 373.0
37
Λ
37
LAFA
0Bw
Λ
8.4% 0 BW 369.4 5 BC 37 5.75 T
Λ
Λ
Λ
37 + 5.25 BCC
S
F
Λ
TW 377.0
ton
37 377.0
Λ
Λ
L
Λ
W
+
Λ
4
A
BW 368.5
Pit
5
Pitch
Λ
ch
e
Λ
E
GG ABELLA GED B
MO OSED
6
Wa
PRO
37
T
Λ
37
Λ
3755..05 TC
LAN
4
0 N)
376
Λ
+
Λ
BC
37
0
.0 SI
4
ll
37
E
N
36
377.0 37 6.25 T
Λ
59 BA
37
Pitch +
37 2
2
D
+ 5.75 BCC
Λ
L
Pitch
P
Λ
S
U
.3 F
37
D
EV O
E)
1
Λ
Λ
M
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
J
ELTOM
3 +
37745.0 TC
E LIN
Λ
S
ULY
376.5 BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
X
9 37 +
Λ
Λ
ENT
35 .5 B 3755..75 TC
OT
5 DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
F
9 +
0
Λ
C
Pi
35
Pitch
1 1
LAG
25 B
(B
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
tc
Λ
37
36 36 N 45° 22' 53" E
Λ
(RIDG
8
h
C
X
Λ
6
S
37 SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
36
Λ
1
0 65.83'
Λ
36
0 WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
36
Λ
37
4
Pit
3756..61 TC
X
6
+371.0 37
Λ
ch
(RID
3756..50 TC
,
Pitc
37
TW 375.0 h BC WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
2
BC
376LINE)
Λ
100' WETLAND + MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
TW 370.0 TW 373.0
025
BW 374.0
GE
+
Pitc
37 +
Pitc DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
h
3767..0 TC
Λ
BUFFER, TYP.
h
BW 366.0 BW 366.0 ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
Ston
3 68 5 BC SHOWN BY THESE DRAWINGS.
Λ
ch
Pit
Y
eW
Pit
364
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
Λ
ch
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Stone
all
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
37
386
UPo
3767..725 TC 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Wire
37 + 5 BC
Wall
3756..0 TC
le
N 31° 41' 31" + E
Guy
Λ
5 BC
C
376
372 68.52' Copyright DTS Provident Design Engineering, LLP 2025
onc
Λ
All rights reserved.
Pad
rete
Λ
TW 367.0 NOT FOR CONSTRUCTION
BW 366.0 30' FRONT YARD SETBACK
+372.0Tw
S ENERGY 30' FRONT YARD SETBACK
DISSAPATOR, TYP.
UPo S 76° 13' 31" E 1 01/21/2026 SITE PLAN APPLICATION
109.88
le
UPole '
S 67° 5 2 02/18/2026 ISSUE TO PLANNING BOARD
UPole 4' 29"
R=47.00' +(355.9) TC E
S 77
(355.4)
L=51.51' WE
TC + 3 03/25/2026 ISSUE TO PLANNING BOARD
Post
Ligh
TLA UPole UPole
ND
OU B +(354.9
4
UPo
t
"E
UPo
Sign raffic
UPo
UPo
ND ) TC
' 43 1
UPo
ARY
° 37
360 2
Wire
le
le
4
le
al B
le
8°
T
le
Guy INV.B=346.83
N7
ox
+(35 INV.A=346.83
Pole l
W 4.4) RIM=350.53
' 03 7'
Sign
64.0
Traf
ER
100.00' BUFF a TC
18"RCP
373.0
DRAIN INLET
64.
te
UPo
a
fic
r
+Bw3
UPo
le
+Tw
le
"W
+(35
A
7
3.7)
B
PR UM
MO
TC
7' 18"RCP
3.6
Wire
Co
UPole
OP EN
UPole
25
Tra l Lid
Guy
Met
Con
urs
Ston
N
w
4.0B
f
Traf l Lid
Wire
Aspha
f
e
Met
OS T
ic
a
+37
UPole
cret
eW
Guy
Sign
fic S
0
a
0+0
Sign
e Pa
ED
lt Drive
all
(35
al B
igna
S .7) 2 UPole
T
d
C+
ox
Ston
Be
Box l
eM Signal Box
354
aso
gi
I NV UPo
MOD
nry Traffic
AD
20" =348.7 le
n: 0
Re
RO
tain
PARCEL 3 -
RC 0
D
T
P ing
02
S
ON
raffi
Wire
+00
Wa Con
MP E 35/2
S ll c. C UPole
Guy
Wire
O
c Sig
urb
CR OUT
Guy
SITE GRADING AND
.00
352 UPole
Traf
.5+
HOSPIT
R
Tw
n
fic S
EXIT
w
al B
RIM=353.63
2.0
DRAINAGE PLAN
.0B
RIM=348.04
PI:
i
DRAIN INLET
+37
gna
ox
R=34.00'
8
MANHOLE (CON-ED)
UPo
+35
AL
0+6
L=49.52'
Polel
RIM=347.41
0
le
Wire
4.6
0
Guy
MANHOLE (CON-ED)
1+
2
RI M
S DR =352 Traffic Signal Pole
AI N .1
PI
I NL 1
:1
NU ET
M
+0
DEE BER
30.0
4
7.
D
STA CO 91320
THE T E N
OF TRO 394 32 RI
IN MM=35
DR
A
'
L
LAN PEOP NEW AN 2.66
LE O YOR
8
DS HO
35
AC K LE
QU F THE RI M
362
I RE =
DB MA 353.0
0 0
2+0
SP-2.0
Y
36
NH 8
OL
E
PI:
Tra
ffic
1
Sto
CONKLIN
AVENUE
Sig
+86
nal
PROPERTY LINE
ne
UPo
35
le THE DEED Tra
ffic Pol
e
8
.38
PEO CO Sig
(TYP.) PLE NTR nal
Wall
OF O Box
THE L NUM
STA BER
TE O 4
F N 91320
EW 4
YO 4 1
Page 88
AYETTE AVENUE
EXISTING
RESIDENCE
#206
Ston
A
e
217.0
Wall
33.12-2-3
EVERGREEN MANOR
6'
Now or Formerly
Carlos & Kasmiry Rondon
Town of Cortlandt, New York
Edge of Asphalt
N 18°
07' 00
"E
EXISTING
RESIDENCE
(APPROXIMATE
LOCATION) OWNER / APPLICANT
#204
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
OSSINING, NY 10562
N 19°
,
LINE
S 68° 33' 00" E
TY
37.31'
ER PLANNER, CIVIL ENGINEER, LANDSCAPE
38' 00
O P
PR .
0
ARCHITECT
TYP - 4
N 19
R
"8W
Edge of Asphalt
0.44
DTS P O DENT
° 38'
33.12-2-2 ntelligent Land se
'
Now or Formerly
00" E
DTS Provident Design Engineering, LLP CA #: 0017846
Michael & Kathryn Parish
CK/
One North Broadway
B A
SET AREA
White Plains, NY 10601
EXISTIN
R D
A ANCE
G DRIV
LAFAYETTE AVENUE
EWAY P: 914.428.0010
E Y
ID B
F: 914.428.0017
30' S DISTUR
UPole
ARCHITECT - PARCEL 3
NON
UPole
80.44
N 55° 14' 20" W BEATTY HARVEY COCO ARCHITECTS
160.05' N 55° 14' 20" W
'
160.05' 162.9216 1300 WALT WHITMAN ROAD
' 9.92'
N 60° 49' 00" W MELVILLE, NY 11747
N 60° 49' 00" W
LAND USE ATTORNEY
N 29° 06' 19" E N 29° 06' 19" E 3 75.0 ZARIN & STEINMETZ
90.0 TW 373.0 81 MAIN STREET
3 34.634.565''
Stone Wall
3 84.0 TW 374.0 BW WHITE PLAINS, NY 10601
TW 371.8 BW
Stone Wall
BW
Edge of Asphalt
Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ
SURVEYOR
Λ Λ Λ Λ Λ
DANIEL T. MERRITTS, PLS
Λ Λ Λ Λ Λ
Λ Λ Λ
5 TBCC
Λ Λ Λ Λ
Λ Λ
7 S
Λ
6 . S 394 BEDFORD ROAD
Λ Λ
Λ
Λ Λ
Λ
376.75 TBCC
Λ Λ Λ Λ
3776.25 PLEASANTVILLE, NY 10570
376.25 3 + 375.75 TBCC
Λ
+ 375.25
Λ
+ WETLAND CONSULTANT
+
X
374
376.25 TBCC TIM MILLER ASSOCIATES, INC.
Λ
Pitch
375.75
ch
X
Pit
10 NORTH STREET
Λ
Pit
PROPOSED 1-STORY
Pit
ch
ch
372
5
6 COLD SPRING, NY 10516
Λ
DING
COMMERCIAL BUIL
37
X
375.5 TBCC
366
Λ
N 45° 22' 53" E
9,600 SF 375.0 +
368
370
X
65.83'
364
Λ
FINISHED FLOOR: 377.0
Λ
h
Pitc
Stone Wall
+
Λ
376.25 TBCC 375.75 TC
375.75
Λ
7 + 375.25 BC P
Pitch
Λ
Concrete
Λ
Λ
itch
.0
Λ
377+ 376.0 TC
Λ Λ Λ Λ Λ
Λ Λ Λ
Λ
UPole
Λ
Pad
7
375.5 BC+
Λ
.5
Λ Λ
Λ
376+ 376.1 TBCC
Λ Λ
Λ Λ
.5
Λ
375.6 +
Λ
376+
Λ Λ
Λ
Λ
Λ
Λ Wire
(R
Λ
Λ
37 LIN
Λ Guy
ID
+ .0
Λ
376
Λ
Pit
Λ
GE
378
377
6 E)
ch
Λ
Λ
SITE PLAN VIEW
Λ
Λ
Λ
.0
Λ
375+
Λ
(RIDGE LINE)
378
Λ
Pit
TC31" E
Λ
7.2541'
3N731° 1" = 20'
Λ
h ch
Pitc
376
Λ
C
376.75 B68.52'
Λ
ch
376
Pit
+
376
Pi
ACK
tc
h
E T B
372 DS
Λ Λ Λ Λ Λ Λ Λ
R
Λ Λ Λ Λ Λ Λ
YA
Λ Λ Λ Λ
Λ Λ Λ
376
Λ
T
Λ Λ
N
Λ Λ
Λ
RO
Λ Λ
Λ
TC
30' F
Λ
3755..50 BC
Λ
Λ
Λ
Λ
Λ
77.0
Λ
37 +
Λ
+
77.5
Pitch
Λ
Pitch
Λ
3
Λ
376.0 TC
Λ
3 TW 368.5
UPole
+
Λ
Λ
79.0
Λ
TW 369.4 375.5 BC
Λ
377.0 TC
Λ
+
Λ
3 BW
Λ
376.5 BC
Λ
TW 369.0
Λ
375.0 TC
BW
Λ
Λ Λ
INV.B
374.5 BC
Λ Λ
UPole
Λ Λ
INV.A =346.83 18"R
Λ
BW
Λ
Λ
Λ Λ Λ
CP THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
Λ Λ Λ Λ Λ Λ =3
1-800-962-7962 OR 811
Λ Λ
RIM= 46.83
Λ Λ Λ
3 76.0 DRA 350.53
TW 363.0 ND
IN IN
L A
LET
ET TYP.
Light
BW
Post
0 ' W 54' 29
"E
3 75.0 10 FFER, S 67°
BU
Traffic
Pole
TW 374.0
Signal
8' 1
B
109.8
BW
Metal Lid
A
Traffic Signal Box
18"RC
Signal Box
P
Stone W
WETLANDS FLAGGED BY
FLAGGED JULY 14, 2025
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
Traffic
A
UPole
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
UPole
S7 DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Metal Lid
Traffic Signal Box
UPole
6° 1 ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
Concrete Pad
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
all
' 31 3 WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
"E UPo MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
le DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ACK
LABELLA
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
UPo
ETB
le RIM SHOWN BY THESE DRAWINGS.
R D S =
MA 348.04 LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
T YA
UPo
le UPo RIM NHO YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
ON
le =34 LE ( DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
R 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
30' F
7.41 CO
N-E
D)
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
PROPERTY LINE
30' NON DISTURBANCE AREA
PROPERTY LINE
206 LAFAYETTE AVE
420 420 1 01/21/2026 SITE PLAN APPLICATION
PROPOSED 1-STORY COMMERCIAL BUILDING PROPOSED EVERGREEN & SHADE TREE 2 02/18/2026 ISSUE TO PLANNING BOARD
(SEE ARCHITECTURAL PLANS) (SEE SP-4.1 SITE LANDSCAPE PLAN) 3 03/25/2026 ISSUE TO PLANNING BOARD
410 410
SCHEMATIC BUILDING SHOWN
204 LAFAYETTE AVENUE
400 TOP OF HIGH PARAPET ELEV. = 397.5 400
EXISTING GRADE
TOP OF ROOF ELEV. = 392.0
390 390
20.5'
EXISTING GRADE CROSS SECTION NOTE:
6 FT. HIGH SOLID HOUSE ELEVATION SHOWN ON THIS CROSS
VINYL FENCE
PROPOSED PAVEMENT
SECTION IS FOR SCHEMATIC PURPOSES ONLY
PARCEL 3 -
SURFACE DRIVEWAY AREA CROSS SECTION THROUGH
380 GROUND FLOOR ELEV. = 377.0 380
EXISTING GRADE ADJACENT PROPERTIES
PROPOSED GRADE
370 PROPOSED RETAINING WALL 370
PROPOSED PAVEMENT PROPOSED CUT SECTION (DESIGNED BY OTHERS) CROSS SECTION A-A
SURFACE PARKING AREA SCALE: HORIZ 1"=10'
VERT. 1"=10'
360 360
SP-2.1
Page 89
N 19°
LI N E,
E RTY
38' 00
P
PRO .
TYP - 4 0
N 19
R
"8W
Edge of Asphalt
0.44
° 38'
33.12-2-2
'
Now or Formerly
00" E
Michael & Kathryn Parish
B A CK/
R D SET AREA EXISTIN
G DRIV
YA ANCE
LAFAYETTE AVENUE
EWAY
I D E B
30' S DISTUR
EVERGREEN MANOR
UPole
C
NON
UPole
80.44
N 55° 14' 20" W
160.05' N 55° 14' 20" W Town of Cortlandt, New York
'
160.05' 162.9216
' 9.92'
N 60° 49' 00" W
N 60° 49' 00" W
N 29° 06' 19" E N 29° 06' 19" E 3 75.0
90.0 34.65' TW 373.0
3 34.65'
Stone Wall
3 84.0 TW 374.0 BW
TW 371.8 BW
Stone Wall
BW
Edge of Asphalt
Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ
Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ
Λ Λ
TC
Λ Λ Λ Λ
Λ Λ
.755 BC S
Λ
6 S
Λ
OWNER / APPLICANT
Λ
Λ
Λ Λ
7
3 76.2
376.75 TBCC
Λ Λ Λ Λ
Λ
376.25 3 + 375.75 TBCC
Λ
+ V.S. CONSTRUCTION CORPORATION
375.25
Λ
+ 37 CROTON DAM ROAD
+ OSSINING, NY 10562
X
374
376.25 TBCC
Λ
Pitch
375.75
ch
X
Pit
Λ
P it
PROPOSED 1-STORY
Pit
ch
ch
372
5
6
Λ
DING
COMMERCIAL BUIL
37
PLANNER, CIVIL ENGINEER, LANDSCAPE
X
375.5 TBCC
366
Λ
N 45° 22' 53" E
9,600 SF 375.0 +
368
ARCHITECT
370
X
65.83'
364
Λ
B DTS P O DENT
FINISHED FLOOR: 377.0
Λ
itch
Stone Wall
P
+ ntelligent Land se
Λ
B 376.25 TBCC 375.75 TC
375.75
Λ
7 + 375.25 BC P DTS Provident Design Engineering, LLP CA #: 0017846
Pitch
Λ
Concrete
Λ
Λ
itch One North Broadway
.0
Λ White Plains, NY 10601
377+ 376.0 TC
Λ Λ Λ Λ Λ
Λ Λ Λ
Λ
UPole
Λ
Pad
7
375.5 BC+
Λ
.5
Λ Λ
P: 914.428.0010
Λ
376+ 376.1 TBCC
Λ Λ
Λ Λ
.5
Λ
F: 914.428.0017
375.6 +
Λ
376+
Λ
Λ
Λ
Λ
Λ
Λ Wire
ARCHITECT - PARCEL 3
(R
Λ
Λ
37 LIN
Λ Guy
ID
+ .0
Λ
376
Λ
Pit
Λ
GE
378
377 BEATTY HARVEY COCO ARCHITECTS
6 E)
ch
Λ
Λ
Λ
Λ
1300 WALT WHITMAN ROAD
Λ
.0
Λ
Λ
375+
(RIDGE LINE)
378
Λ
Pit MELVILLE, NY 11747
TC31" E
Λ
7.2541'
3N731°
Λ
h ch
Pitc
376
Λ
C
B68.52'
Λ
ch
37 6.7 5
376
Pit
+
376
Pi
K LAND USE ATTORNEY
tc
AC
h
S E T B
372 RD ZARIN & STEINMETZ
Λ Λ Λ Λ Λ Λ Λ Λ Λ Λ
Λ Λ Λ
A
Λ Λ Λ Λ
Y
Λ Λ Λ
376
Λ
T
Λ
81 MAIN STREET
Λ
RON
Λ Λ
Λ
Λ Λ
Λ
TC F
Λ
' WHITE PLAINS, NY 10601
3755..50 BC
Λ
0
Λ
Λ
3
Λ
Λ
77.0
Λ
37 +
Λ
+
77.5
Pitch
Λ
Pitch
Λ
3
Λ
376.0 TC
Λ
3 TW 368.5 SURVEYOR
UPole
+
Λ
Λ
79.0
Λ
TW 369.4 375.5 BC
Λ
377.0 TC
Λ
+
Λ
3 BW
Λ
376.5 BC
Λ
DANIEL T. MERRITTS, PLS
TW 369.0
Λ
375.0 TC
BW
Λ
Λ Λ
INV.B
374.5 BC
Λ Λ
UPole
394 BEDFORD ROAD
Λ Λ
INV.A =346.83 18"R
Λ
BW
Λ
Λ Λ Λ
Λ
Λ Λ Λ CP
PLEASANTVILLE, NY 10570
Λ Λ Λ Λ Λ =3
RIM= 46.83
Λ Λ Λ
3 76.0 DRA 350.53
TW 363.0 D
LAN P.
IN IN
LET WETLAND CONSULTANT
T
Light
BW E
Post
'W TY
"E
54' 29
75.0 100 FFER, S 67° TIM MILLER ASSOCIATES, INC.
3 BU 10 NORTH STREET
Traffic
Pole
TW 374.0
Signal
8' 1 COLD SPRING, NY 10516
B
109.8
BW
Metal Lid
A
Traffic Signal Box
18"RC
Signal Box
P
Stone W
WETLANDS FLAGGED BY
FLAGGED JULY 14, 2025
Traffic
UPole
UPole
S7
Metal Lid
Traffic Signal Box
UPole
6° 1
Concrete Pad
all
' 31 3
"E UPo
le
K
LABELLA
C
UPo
TBA
le
E
RIM
R D S =
MA 348.04
YA
UPo UPo
T
le RIM NHO
N
le =
RO
MA 347.41 LE (
30' F
NHO CO
C N-E
on LE ( D)
c. CO
N-E
UPo D)
Cu
le
rb
C
HOSPI
EXIT
UPo
le
TAL
Sign
Traf al Box
UPo fic Wire
UPo le
Guy RIM
SITE PLAN VIEW
le = THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
DRA 353.6 PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
IN IN 3 1-800-962-7962 OR 811
LET 1" = 20'
+(3
55.
TC 9) Traf
UP UPo fic S
ol le igna
e (35 l Po
5.4 le
TC )
400 400
+
PROPOSED PROPERTY LINE
TOP OF HIGH PARAPET ELEV. = 397.5 SCHEMATIC BUILDING SHOWN
EXISTING EDGE OF
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
PROPOSED EDGE OF
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
RIGHT-OF-WAY LINE
EXISTING PROPOSED 1-STORY COMMERCIAL BUILDING
PAVEMENT
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
TOP OF ROOF ELEV. = 392.0 SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
GRADE
PAVEMENT
390 390
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
PROPOSED CUT SECTION
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
SHOWN BY THESE DRAWINGS.
EXISTING GRADE
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
380 380
SIGHT LI Copyright DTS Provident Design Engineering, LLP 2025
GROUND FLOOR ELEV. = 377.0 NE All rights reserved.
NOT FOR CONSTRUCTION
PROPOSED SURFACE LAFAYETTE
370 PARKING AREA 370
CROSS SECTION B-B AVENUE
SCALE: HORIZ 1"=10' PROPOSED PAVEMENT SURFACE 1 01/21/2026 SITE PLAN APPLICATION
TURN AROUND AREA PROPOSED GRADE
VERT. 1"=10' 2 02/18/2026 ISSUE TO PLANNING BOARD
360 360 3 03/25/2026 ISSUE TO PLANNING BOARD
3.5 FT. ABOVE PAVEMENT
6 FT. HIGH FENCE
400 TOP OF HIGH PARAPET ELEV. = 397.5 400
SCHEMATIC BUILDING SHOWN
RIGHT-OF-WAY LINE
PROPERTY LINE
PROPERTY
PROPOSED CUT SECTION TOP OF ROOF ELEV. = 392.0
20.5'
LINE
390 390
EDGE OF PROPOSED
EXISTING GRADE 30' NON DISTURBANCE AREA
PAVEMENT
380 380 PARCEL 3 -
GROUND FLOOR ELEV. = 377.0 CROSS SECTIONS FROM
PROPOSED GRADE ROADWAYS
370 E 370
SIGH T LIN
CROMPOND ROAD CROSS SECTION C-C
ROUTE 35/202 Walk PROPOSED PAVEMENT SCALE: HORIZ 1"=10'
SURFACE PARKING AREA VERT. 1"=10'
360 360
PROPOSED CUT SECTION
PROPOSED GRADE
350
3.5 FT. ABOVE PAVEMENT
350
SP-2.2
Page 90
NEW FIRE HYDRANT
AND FUTURE WATER
MAIN EXTENSION, TYP.
8" DIP, CL 54
(CAP END)
EVERGREEN MANOR
100 Town of Cortlandt, New York
' WE
TLA
ND
BUF FUTURE SANITARY SEWER
F ER MAIN EXTENSION, TYP.
1 8" DIP, SDR-35
(CAP END)
FUTURE
MAIN SANITARY SEWER
EXTENSION
OWNER / APPLICANT
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
NEW 8" OSSINING, NY 10562
GATE VALVE, TYP.
PLANNER, CIVIL ENGINEER, LANDSCAPE
THRUST BLOCK,
THRUST BLOCK, TYP.
TYP.
ARCHITECT
DTS PROVIDENT
100
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
'
One North Broadway
W
White Plains, NY 10601
E T
P: 914.428.0010
L
F: 914.428.0017
A N
ARCHITECT - PARCEL 3
D
BEATTY HARVEY COCO ARCHITECTS
BUFFER
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
FUTURE WATER MAIN ZARIN & STEINMETZ
EXTENSION 81 MAIN STREET
WHITE PLAINS, NY 10601
FUTURE SANITARY SEWER
MAIN EXTENSION
SURVEYOR
L A
DANIEL T. MERRITTS, PLS
F
394 BEDFORD ROAD
A
PLEASANTVILLE, NY 10570
Y
WETLAND CONSULTANT
ETT
PROPERTY LINE, TIM MILLER ASSOCIATES, INC.
TYP. 10 NORTH STREET
R-40
E
COLD SPRING, NY 10516
VE A
N
PROPERTY LINE, MONUMENT
U
(TYP.) PROPOSED
10'-0" MIN.
E
SEPARATION,
TYP. 30' SIDE YARD SETBACK/
PROPOSED
NONDISTURBANCE AREA
Λ 4" DIP, CL54 FIRE LATERAL
3" DIP, CL54 DOM. LATERAL
Λ Λ Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ Λ
(SIZE TO BE CONFIRMED BY MEP)
Λ Λ Λ
Λ Λ Λ Λ Λ
Λ Λ
Λ
Λ Λ Λ Λ Λ Λ
Λ
Λ Λ Λ
Λ
Λ
NEW SMH-R2
Λ Λ Λ
Λ Λ Λ
Λ
Λ
RIM. 175.15
Λ
Λ
NEW FIRE HYDRANT
Λ
Λ
Λ
Λ
Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ Λ
PROPOSED
Λ Λ Λ
Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ
6" DIP SANITARY SEWER LATERAL
Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ Λ
Λ Λ Λ
(6" D.I.P., CL52) S=0.02 MIN.
Λ Λ Λ
Λ
Λ Λ Λ Λ
20'-0" WIDE
Λ Λ Λ Λ
Λ
Λ Λ Λ
WATER MAIN EASEMENT
Λ Λ Λ Λ Λ
Λ
Λ Λ
Λ
Λ
Λ
Λ
Λ
UPo
E
Λ
Λ
ENU
Λ
Λ
Λ Λ
Λ
Λ Λ
Λ
S
le
Λ
Λ
E AV
Λ Λ
Λ Λ
PROPOSED
Λ
Λ Λ
8" DIP WATERMAIN
Λ Λ
YETT
Λ Λ
Λ
Λ Λ
Λ Λ THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
Λ
NEW SMH-R1
Λ
1-800-962-7962 OR 811
Λ
LAFA
Λ
Λ
RIM. 363.84
Λ
Λ
S
FLA
Λ
ton
Λ
Λ
Λ
WE
Λ
NEW 8"
Λ
Λ
eW
G ABE
GATE VALVE, TYP.
Λ
Λ
T
3
L
Λ
G
Λ
a
A
Λ
Λ
L S FLAG
ll
ED LLA
S
Λ
ND
CONNECT NEW 8"
Λ
Λ
Λ
WATER MAIN TO
X
Λ
Λ
J
Λ
CAP 8" EXISTING WATER MAIN
U
Λ
Λ
X
Λ
WATER W/ NEW 8"x8"x8" TEE
LY 1
Λ
Λ
Λ
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
MAIN
X
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
Λ
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
4
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
G
Λ
,
Sto
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
202
Λ
E
n
8"
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
D
e
Λ
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Se
Wa
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
5
Λ
BY
RELOCATED ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
UPo
CONNECT
w
ll
SHOWN BY THESE DRAWINGS.
Λ
Wire
UTILITY POLE - LOCATION
e
8"C
TO EXIST 8" DIP Guy
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
Λ
r Pip
le
TO BE VERIFIED W/ UTILITY CO.
C
WATERMAIN STUB P YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
onc
IP
AP ER OL DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
Λ
Pad e
PRO D 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
e
ret
Λ
XIM SURV RIM=359.78
30' FRONT YARD SETBACK
ATE EY
SEW - NO SEWER MANHOLE
ER T FO Copyright DTS Provident Design Engineering, LLP 2025
MA UN All rights reserved.
NH D
NOT FOR CONSTRUCTION
OL RIM=356.16
30' FRONT YARD SETBACK
E
ENERGY UPo SEWER MANHOLE
DISSAPATOR, TYP. le
UPole
Pipe
ipe
8" Sewer P UPole 8" Sewer
1 01/21/2026 SITE PLAN APPLICATION
WE
Pos t
Lig
TLA UPole UPole
02/18/2026 ISSUE TO PLANNING BOARD
ND
2
h
BO
UPo
t
UPo
SignTraffic
UPo
UND
UPo
Wire ARY
3 03/25/2026 ISSUE TO PLANNING BOARD
le
le
le
al B
Guy INV.B=346.83
le
3
INV.A=346.8
ox
Pole al
W 50 .5 3
Sign fic
RI M =3
18"RCP
Traf
a DRAIN INLET
te
UPo
r UPo 16"CIP
le
le
A
B
IN
Wire 8"HP GAS MA 18"RCP
Co
UPole UPole 16"CIP
Guy
Traf tal Lid
M
Co
urs
Wire
e
Traf tal Lid
Aspha
Me
16"CIP
fic
n
UPole
e
c
Guy
fic S
rete
0
S
0+0
8"CIP
Sign
i gna
16"CIP
lt Drive
ign
UPole 8"CIP
Pad
Ston
l Bo
Be
al B
eM Signal Box
IN V
gin
UPo aso
x
MOD
Traffic
AD
20" =348 nrRye
ox
le 8"CIP
RO
t
: 0+
RC .70 ain
D
Traf
02
in
ON
P gW Wire Con
MP E 35/2
00.
all 8"CIP Guy c.C UPole
Wire
O
fic S
CR OUT
urb
Guy
16" UPole
Traf
00
CIP
HOSPIT
R
igna
fic
EXIT
RIM=353.63
PARCEL 3 -
RIM=348.04
PI:
DRAIN INLET
S
PROPOSED 6" DIP SANITARY
l
i
MANHOLE (CON-ED)
g
UPo
B
0
o
n
SEWER CONNECTION
AL
+64 le
PER OLD SURVEY - NOT FOUND
SITE UTILITY PLAN
al P.62
8"C
xG
RIM=347.41
00
Wire
IP
INV. OUT: 366.5
le
APPROXIMATE SEWER MANHOLE MANHOLE (CON-ED)
1+
o
uy
RI
Me
te DR M=35 Traffic Signal Pole
AIN 2.1
NU W a r Pi t PI IN L 1
DEEMBER
ter : 1+
ET
STA D C 491 07
THE TE O ONTR 32039 .3 D R R IM
2 AIN =3
RELOCATE
LAN PEO F NEWOL 4 MA 52.6
NH 6
FIRE HYDRANT
DS PLE
AC OF YORK RIM OL
E
QU THE
IR E MA =353.
0
2+0
DB NH 08
Y SEW RIM OLE
ER =35
PI:
8"C Tra MAN 3.18
ffic H
1+8
Sto
Sig OLE
CONKLIN
AVENUE 8" PIPE
16"PIPE
SP-3.0
IP
PROPERTY LINE
UPo D Tr n a
ne
THE EED aff
6.3
e l ic S l Po
PEO CO le
(TYP.) ign
8
PLE NTR
Wall
al B
R IM OF OL ox
TH NU
DR =355
AIN .65 LANE STATMBER
IN L Stre DS E O 491
ET AC F N 320
CR et S
i gn
QU EW 441
IR E Y O
OM D B RK
Y
PO
Page 91
•
3+00
•
• PLANT SCHEDULE
•
•
NEW FIRE HYDRANT
•
CODE QTY BOTANICAL / COMMON NAME CONT/SIZE REMARKS
•
AND FUTURE WATER
•
•
•
MAIN EXTENSION, TYP.
4+00
•
A. SHADE TREES
•
8" DIP, CL 54
•
•
•
(CAP END) AO 4 ACER RUBRUM 'OCTOBER GLORY' / OCTOBER GLORY RED MAPLE B&B/ 3" - 3-1/2" CAL. SINGLE STRAIGHT LEADER, BALANCED & FULL BRANCHING
•
0
2+0 LR 3 LIQUIDAMBAR STYRACIFLUA 'ROTUNDILOBA' / ROUND-LOBED SWEET GUM B&B/ 3" - 3-1/2" CAL. SINGLE STRAIGHT LEADER, BALANCED & FULL BRANCHING
•
3+00 402.49 QP 4 QUERCUS PALUSTRIS / PIN OAK B&B/ 3" - 3-1/2" CAL. SINGLE STRAIGHT LEADER, BALANCED & FULL BRANCHING
•
4+91
3+48 TR 5 TILIA AMERICANA 'REDMOND' / REDMOND AMERICAN LINDEN B&B/ 3" - 3-1/2" CAL. SINGLE STRAIGHT LEADER, BALANCED & FULL BRANCHING
EVERGREEN MANOR
•
0
2+0
•
3+00 UN 3 ULMUS AMERICANA 'NEW HARMONY' / NEW HARMONY AMERICAN ELM B&B/ 3" - 3-1/2" CAL. SINGLE STRAIGHT LEADER, BALANCED & FULL BRANCHING
1+
•
00
Town of Cortlandt, New York
•
3+00 B. EVERGREEN TREES
•
4+00
PC 14 PICEA PUNGENS / COLORADO SPRUCE B&B/ 8'-9' HGT. FULL, DENSE, AND BALANCED SHAPE
•
0
1 +0 FUTURE SANITARY SEWER
PG 19 PICEA GLAUCA / WHITE SPRUCE B&B/ 7'-8' HGT. FULL, DENSE, AND BALANCED SHAPE
PS2 11 PINUS STROBUS 'BENNETT'S FASTIGIATE' / BENNETT'S FASTIGIATE WHITE PINE B&B/ 7'-8' HGT. FULL, DENSE, AND BALANCED SHAPE
0
MAIN EXTENSION, TYP.
2+0
0 8" DIP, SDR-35
1 1+0 (CAP END) C. ORNAMENTAL TREES
2+00
AX 3 AMELANCHIER X GRANDIFLORA / APPLE SERVICEBERRY B&B/ 7'-8' HGT. BALANCED AND FULL BRANCHING
BD 9 BETULA NIGRA 'BNMTF' / DURA HEAT® RIVER BIRCH B&B/ 7'-8' HGT. BALANCED AND FULL BRANCHING
005
CO 7 CELTIS OCCIDENTALIS / COMMON HACKBERRY B&B/ 2" - 2-1/2" CAL. BALANCED AND FULL BRANCHING
2+20+
55++0001
FUTURE CV 6 CHIONANTHUS VIRGINICUS / WHITE FRINGETREE B&B/ 7'-8' HGT. BALANCED AND FULL BRANCHING
00
MAIN SANITARY SEWER 0+
EXTENSION
1+00 NATIVE RESTORATION SEED MIX 10,635 sf OWNER / APPLICANT
0+
00
WOODLAND RESTORATION AREA SEED MIX V.S. CONSTRUCTION CORPORATION
ERNMX-132-1 "RIGHT OF WAY NATIVE WOODS MIX WITH ANNUAL RYEGRASS" BY
37 CROTON DAM ROAD
ERNST CONSERVATION SEEDS (800) 873-3321 OR APPROVED EQUAL.
NEW 8" INCLUDES THE FOLLOWING:
OSSINING, NY 10562
1+00
0+00
GATE VALVE, TYP. ANNUAL RYEGRASS, DEERTONGUE, SWITCHGRASS, VIRGINIA WILD RYE
00
0+
SEEDING RATE: 30 LBS/ACRE PLANNER, CIVIL ENGINEER, LANDSCAPE
SEED AND MAINTAIN PER SEED SUPPLIER`S SPECIFICATIONS.
THRUST BLOCK,
1+00
APPLICATION METHOD: HYDROSEED WITH MULCH TACKIFIER. ARCHITECT
TYP.
DTS P O DENT
ntelligent Land se
1+00
LAWN 8,066 sf DTS Provident Design Engineering, LLP CA #: 0017846
LAWN SEED MIX - SUN/SHADE One North Broadway
HARDSCRABBLE "ALL PURPOSE SUN/SHADE MIX" AS SUPPLIED BY White Plains, NY 10601
4+00
HARDSCRABBLE FARMS, INC. (914) 669-5633 OR APPROVED EQUAL. CONTAINS
THE FOLLOWING: P: 914.428.0010
30% SOPRANO PERENNIAL RYE, F: 914.428.0017
388.01
30% INTEGRA PERENNIAL RYE,
0
3+73
ARCHITECT - PARCEL 3
0+0
30% REBEL IV TALL FESCUE,
0+
10% PALOUSE KENTUCKY BLUEGRASS
BEATTY HARVEY COCO ARCHITECTS
00
1300 WALT WHITMAN ROAD
0+00
SEEDING RATE: 6 LBS/1,000 SF.
1+00 1+55 MELVILLE, NY 11747
0+00
LAND USE ATTORNEY
0+00
1+00 FUTURE WATER MAIN
ZARIN & STEINMETZ
389.99 81 MAIN STREET
EXTENSION 2+00
394.010+00 2+58 WHITE PLAINS, NY 10601
1+00 SANITARY SEWER 3+00
394.00 FUTURE 3+56
0+00
MAIN EXTENSION 2+00 SURVEYOR
0000
0+
3+00
1+00 3+ 0+72 DANIEL T. MERRITTS, PLS
394 BEDFORD ROAD
2+00
PLEASANTVILLE, NY 10570
0
1+0
WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
0
0+0
2+00 10 NORTH STREET
1+5
NEW FIRE HYDRANT COLD SPRING, NY 10516
4 AND FUTURE WATER
402.14
MAIN EXTENSION, TYP.
2+00 8" DIP, CL 54
2+00 (CAP END)
EXISTING TREE LINE
TO REMAIN
1+00
1+00
386
Λ Λ NEW INFILL TREE PLANTING
WITH EXISTING TREE LINE TO BE
Λ Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
DETERMINED BY TREE SURVEY
Λ Λ Λ
Λ
384.30
Λ Λ Λ
Λ Λ Λ
Λ
Λ
Λ Λ
FUTURE WATER 3840+
Λ Λ
SANITARY SEWER 0 POST TOP MOUNTED LIGHT
Λ
0
Λ
Λ
Λ Λ Λ
Λ
Λ
SERVICE LATERAL, TYP.
Λ Λ
ICE LATERAL, TYP. 12" MOUNTING HEIGHT 30' SIDE YARD SETBACK/
Λ Λ Λ
378
Λ Λ
Λ
Λ
8" DIP, CL 54 LAWN
Λ
WITH AMBER LIGHT
Λ
8" DIP, SDR-35 NONDISTRUBANCE AREA
Λ
376
Λ
Λ
(CAP END)
Λ
(CAP END)
376
Λ
Λ
Λ
Λ
13'-0"
Λ
382
376
Λ Λ Λ
Λ Λ Λ Λ Λ
Λ Λ
Λ
Λ
Λ Λ Λ
SEPARATION,
Λ
LAWN
Λ Λ
Λ
378
Λ Λ Λ Λ
Λ
Λ
Λ
Λ
3 AO
Λ
Λ
TYP. BUILDING MOUNTED
Λ
Λ
Λ Λ Λ Λ Λ Λ
Λ
Λ
DOWN LIGHT 15'
Λ Λ
Λ
Λ Λ Λ
378
Λ Λ
Λ
Λ
MOUNTING HEIGHT (TYP.)
Λ Λ Λ Λ
Λ
Λ Λ Λ
Λ
Λ
MULCHED
Λ
Λ
.00
Λ
Λ
Λ
Λ
1 AO ISLAND
Λ
UPo
6
E
0+
STABILIZED TURF
Λ
Λ
ENU
Λ
0+00
37
Λ
Λ
Λ
00
Λ
(TYP.) PARKING LOT DOWN LIGHT 15'
Λ
Λ Λ
le
Λ
S
Λ
Λ
Λ
MOUNTING HEIGHT (TYP.)
E AV
Λ Λ
Λ Λ
:
Begin
Λ
Λ Λ
4.96
Λ Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
CONCRETE
YETT
Λ Λ
Λ
1+0 PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
Λ Λ
0 3 CV
7
1-800-962-7962 OR 811
SIDEWALK
Λ Λ
Λ
PI: 0+
Λ
Λ
LAFA
0
Λ
Λ
1 TR
Λ
0+0
Λ
S
F
Λ
BIO-RETENTION AREA
ton
Λ
Λ
L
Λ
DEV 8 BR-8
W
Λ
A
MULCHED
Λ
(8,029 SF)
e
Λ
E
GG ABELLA GED B
ISLAND
Wa
T
Λ
Λ
LAN
376
(TYP.)
Λ
1 CO
Λ
3 TR
ll
E
Λ
D
0+
Λ
L
S
Λ
00 2 LR
D
5 PG
Λ
Λ
J
3 BD
Λ
S
ULY
X
Λ
Λ
8 PC
F
Λ
LAG
Λ
Λ
3 BD
0
0+
X
Λ
1 TR NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
1+0
00
Λ
1
Λ
0+50
Λ
1 CV 2 QP BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
4
3 BD
X
6
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
, 202
1 LR
37
NEW HEAVY DUTY 2 CV ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
0
376
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
1+0
ASPHALT PAV'T WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
Λ
(TYP.)
Ston
5
3 PG 1 AX WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
Y
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
eW
LAWN
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
Stone
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
all
Λ
3 PS2 1 CO 2 CO SHOWN BY THESE DRAWINGS.
UPo
Λ
5 PG 2 AX 3 PC LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
Wall
2 QP
le
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Λ
C
3 CO DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
376
372
onc
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
1+00
Λ
Pad
rete
Λ
EXISTING TREE LINE
TO REMAIN Copyright DTS Provident Design Engineering, LLP 2025
3 PS2 NATIVE WOODLAND All rights reserved.
3 PG RESTORATION MIX NOT FOR CONSTRUCTION
ENERGY UPo 3 PC
DISSAPATOR, TYP. le 1 UN 3 PG
UPole
2 UN
0
UPole
5 PS2
2+0
1 01/21/2026 SITE PLAN APPLICATION
0
2+0
02/18/2026 ISSUE TO PLANNING BOARD
Post
Ligh
PI : 2 2
UPole UPole
+05
.97
UPo
t
UPo
UPo
UPo
3 03/25/2026 ISSUE TO PLANNING BOARD
UPo
3.09
le
le
2+3
le
le
PI:
le
UPo
UPo
ENTRY ROAD
le
le
UPole UPole
9
5.3
Con
Ston
I : 2+7
Aspha
P UPole
cret
e
0
Wall
0+0
Sign
e Pa
lt Drive
0
UPole
0+0
d
Ston
Be
eM
aso
gi
UPo nry
AD
Beg
n: 0
le Re
RO
3+0
tain
D
in
ON 02
gW
in:
+00
Con
MP E 35/2
all
0
c. UPole
Cu
O
0+0
CR OUT
rb
.
UPole
00
0 R
0.0
1+0
PARCEL 3 -
.52
0
PI:
PI:
9
1+12 2
PI: 0+6
UPo
6.8
SITE LANDSCAPE PLAN
0+5
0+6
: 3+3
0
le
3+3
1.0
4.6
0
1+
: 1+
5
2
7
11.
PI
:1
3 9
+0
7.
32
PI:
SP-4.1
1+8
Sto
CONKLIN
AVENUE
n
6.3
e
8
Wall
CONNECT PROPOSED 8"
Page 92
TREE PIT DIAMETER AT PLANTING, PRUNE TREE PIT DIAMETER
BALL DIA. MIN. PIT WIDTH TREES ONLY TO REMOVE
BROKEN OR CROSSING BALL DIA. MIN. PIT WIDTH
UP TO 48" BALL DIA. +2'
BRANCHES AS DIRECTED UP TO 48" BALL DIA. +2' WOOD TREE STAKE
48" UP 1 3/4 x BALL DIA. WOOD TREE STAKE BY OWNER'S 48" UP 1 3/4 x BALL DIA. CLEAR OF ROOT BALL HYDROSEED (FOR SEEDED SLOPES)
EVERGREEN MANOR
CLEAR OF ROOT BALL REPRESENTATIVE AND TREE STAKE TIE OR EROSION CONTROL BLANKET ON
PIT DIAMETER IN COMPACTED SOIL AND TREE STAKE TIE (SEE NOTE #1) ALL EXPOSED SLOPES GREATER
(SEE NOTE #1) PIT DIAMETER IN COMPACTED SOIL
BALL DIA. MIN. PIT WIDTH THAN OR EQUAL TO 3:1
TOP OF ROOT COLLAR FLUSH BALL DIA. MIN. PIT WIDTH TOP OF ROOT COLLAR FLUSH
UP TO 48" BALL DIA. +5'
Town of Cortlandt, New York
WITH GROUND LEVEL; NO WITH GROUND LEVEL; NO PREVIOUS GROWING LEVEL AT
48" UP 2 x BALL DIA. UP TO 48" BALL DIA. +5'
MULCH WITHIN 6" OF TRUNK MULCH WITHIN 6" OF TRUNK FINISHED GRADE
48" UP 2 x BALL DIA.
2" DEEP MULCH 2" DEEP MULCH - NO MULCH
STAKING DIAGRAM SECONDARY 2" DEEP MULCH WITHIN 6" OF TRUNK
AFTER PLACEMENT REMOVE STAKING DIAGRAM SECONDARY
TREE NO. OF STAKE MAINTAIN 4" HIGH, 8" WIDE LIP ON
4'-0" MIN
ALL STRINGS, TWINES, AND TREE NO. OF STAKE 6" HIGH PLANTING SAUCER
CAL. STAKES LOCATION SAUCER BERM DOWNHILL SIDE ONLY
2"-4" 2 180 DEGREES LACINGS; REMOVE AT LEAST CAL. STAKES LOCATION
3 120 DEGREES TOP HALF OF ANY BURLAP OR 2"-4" 2 180 DEGREES GROUND LEVEL
EXTENT OF 4"-6" TOP OF ROOT COLLAR FLUSH
WIRE BASKET AFTER TREE IS EXTENT OF 4"-6" 3 120 DEGREES
ROOT BALL STABILIZED IN PIT TOPSOIL MIX WITH GROUND LEVEL; NO
2"
ROOT BALL MULCH WITHIN 6" OF TRUNK FEATHER OUT ON 1:1 GRADIENT
2"
SECONDARY
6'-0"
TREE PLANTING TIE 6" HIGH PLANTING SAUCER
STAKES TREE PLANTING TIE SECONDARY SCARIFY WALL AND
TO ALLOW SWAY 3" HIGH PLANTING SAUCER EXISTING SLOPE
0° TOPSOIL MIX TO ALLOW SWAY STAKES BOTTOM OF PIT ALL 3" DEEP MULCH
PRIMARY STAKE 12 0°
GROUND LEVEL 12 AROUND WITH SHARP TOOL TOPSOIL MIX UNDISTURBED SOIL
2"
PRIMARY STAKE REMOVE ALL STRINGS,
6"
3'-0"
GROUND LEVEL
3"
TWINES, AND LACINGS IF ANY
UNDISTURBED SUBGRADE
DIRECTION OF 12 SCARIFY WALL AND BOTTOM
0° DIRECTION OF 12
PREVAILING WIND TREE TRUNK OF PIT ALL AROUND WITH 0° SCARIFY WALL AND
PREVAILING WIND
SHARP TOOL
TREE TRUNK
VARIES - SEE BOX
AFTER PLACEMENT, REMOVE BOTTOM OF PIT ALL OWNER / APPLICANT
6"
SECONDARY
3'-0"
SECONDARY ALL STRINGS, TWINES AND AROUND WITH SHARP TOOL
6"
STAKES LACINGS; REMOVE AT LEAST
UNDISTURBED SUBGRADE STAKES
TOP HALF OF ANY BURLAP OR V.S. CONSTRUCTION CORPORATION
UNDISTURBED SUBGRADE
WIRE BASKET AFTER TREE IS 37 CROTON DAM ROAD
VARIES - SEE BOX STABILIZED IN PIT
NOTE:
1. STAKE ONLY WHERE TREES ARE EXPOSED TO STRONG
PLANTING MOUND; UNDISTURBED
NOTE: VARIES - SEE BOX OSSINING, NY 10562
OR TAMPED SUBGRADE PLANTING MOUND; PLANTING MOUND; UNDISTURBED
WINDS, PLANTED SLOPE IS GREATER THAN OR EQUAL TO 3:1 1. STAKE ONLY WHERE TREES ARE EXPOSED TO STRONG UNDISTURBED OR OR TAMPED SUBGRADE
OR AS DIRECTED BY OWNER'S REPRESENTATIVE; SEE WINDS, PLANTED SLOPE IS GREATER THAN OR EQUAL TO 3:1 TAMPED SUBGRADE NOTE: NOTE:
STAKING DIAGRAM. OR AS DIRECTED BY OWNER'S REPRESENTATIVE; SEE 1. SCARIFY ROOT BALL OF CONTAINER 1. PLANTS SET VERTICALLY, NOT PERPENDICULAR TO SLOPE.
2. SCARIFY ROOT BALL OF CONTAINER STOCK ALL AROUND STAKING DIAGRAM. STOCK ALL AROUND W/SHARP TOOL. 2. EROSION CONTROL BLANKET FOR SEEDED SLOPES TO BE "LANDLOK CS2" OR "PROPEX ECSC-2B" OR APPROVED EQUAL. PLANNER, CIVIL ENGINEER, LANDSCAPE
W/SHARP TOOL. 2. SCARIFY ROOT BALL OF CONTAINER STOCK ALL AROUND W/ 3. EROSION CONTROL BLANKET FOR PLANTED SLOPES TO BE JUTE MESH BLANKET OR APPROVED EQUAL.
SHARP TOOL. ARCHITECT
DTS P O DENT
DECIDUOUS TREE PLANTING EVERGREEN TREE PLANTING SHRUB PLANTING SLOPE PLANTING ntelligent Land se
1 2 3 4
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
WHITE PLAINS, NY 10601
SURVEYOR
DANIEL T. MERRITTS, PLS
394 BEDFORD ROAD
PLEASANTVILLE, NY 10570
WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
10 NORTH STREET
COLD SPRING, NY 10516
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
1-800-962-7962 OR 811
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
SHOWN BY THESE DRAWINGS.
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
1 01/21/2026 SITE PLAN APPLICATION
2 02/18/2026 ISSUE TO PLANNING BOARD
3 03/25/2026 ISSUE TO PLANNING BOARD
PARCEL 3 -
PLANT LIST AND
PLANTING DETAILS
SP-4.2
Page 93
DOWN LIGHT (DL) POLE AND FIXTURE SCHEDULE
# of Throw Fixture and Pole
ID # Fixtures Type Manufacturer Fixture Order Number Pole Order Number
DL1 1 T4M GARDCO DL1-P-A03-8272-T2M-HIS-AR-FAWS6-BK SRA-STB-4-188-12-D1-BK
DL2 1 T2M GARDCO DL1-P-A03-8272-T2M-WAL-FAWS6-BK
DL3 1 T4M GARDCO DL1-P-A03-8272-T4M-HIS-AR-FAWS6-BK SRA-STB-4-188-12-D1-BK EVERGREEN MANOR
DL4 1 T4M GARDCO DL1-P-A03-8272-T4M-WAL-FAWS6-BK Town of Cortlandt, New York
DL5 1 T3M GARDCO DL1-P-A03-8272-T4M-HIS-AR-FAWS6-BK SRA-STB-4-188-12-D1-BK
DL6 1 T2M GARDCO DL1-P-A03-8272-T2M-WAL-FAWS6-BK
DL7 1 T3M GARDCO DL1-P-A03-8272-T2M-HIS-AR-FAWS6-BK SRA-STB-4-188-12-D1-BK
DL8 1 T2M GARDCO DL1-P-A03-8272-T2M-WAL-FAWS6-BK
DL9 1 T3M GARDCO DL1-P-A03-8272-T2M-AR-FAWS6-BK SRA-STB-4-188-12-D1-BK
ALL DOWN LIGHTS INCLUDE A HOUSE SIDE SHIELD (HIS) OWNER / APPLICANT
V.S. CONSTRUCTION CORPORATION
POST TOP LIGHT (PT) POLE AND FIXTURE SCHEDULE 37 CROTON DAM ROAD
# of Throw OSSINING, NY 10562
ID # Fixtures Type Fixture and Pole Manufacturer Fixture Order Number Pole Order Number
PT1 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF PLANNER, CIVIL ENGINEER, LANDSCAPE
PT2 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF ARCHITECT
PT3 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF DTS P O DENT
ntelligent Land se
PT4 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
PT5 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF White Plains, NY 10601
PT6 1 T2 ARCHITECTURAL AREA LIGHTING PROV2-36L-325-AMB-T2-BLT-CL-HS DB12-4F14-188-BLT-PTF P: 914.428.0010
F: 914.428.0017
HS INDICATED THOSE POST TOP LIGHTS WITH A HOUSE SIDE SHIELD
PHOTOMETRICS FOR ENTRY DRIVE DO NOT REFLECT AMBER LIGHT USE OF IES FILES FOR AMBER LIGHTS ARE NOT AVAILABLE.
ARCHITECT - PARCEL 3
PHOTOMETRICS SHOWN ARE FOR CLOSEST COMPARABLE LIGHT. DTSP IS WORKING WITH LIGHT MANUFACTURERS TO OBTAIN BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
NOTES: MELVILLE, NY 11747
1. ALL LIGHTS HAVE A MAXIMUM MOUNTING HEIGHT OF 15'
2. ALL SITE LIGHTS ARE MOUNTED ON A 24" DIAMETER CONCRETE BASE. THE BASE FOR POST TOP LIGHTS IS 6" ABOVE LAND USE ATTORNEY
GRADE. THE BASE FOR PARKING LOT DOWNLIGHTS IS 24" ABOVE GRADE. ALL LIGHT POLE BASES EXTEND A MINIMUM
OF 5' BELOW GRADE. ZARIN & STEINMETZ
3. HIS = INTERNAL HOUSE SIDE SHIELD (NOT REFLECTED IN PHOTOMETRIC CALCULATIONS.) 81 MAIN STREET
4. PHOTOMETRIC CALCULATIONS INCLUDE BUILDING MOUNTED LIGHTS. WHITE PLAINS, NY 10601
5. THE PHOTOMETRIC PLAN AND LIGHTING DETAILS HAVE BEEN SUBMITTED TO AND APPROVED BY TOWN OF
CORTLANDT. SUBSTITUTIONS SUBMITTED FOR APPROVAL REVIEW BY PROJECT ENGINEER MUST HAVE SAME FIXTURE SURVEYOR
STYLE, WATTAGE, COLOR TEMPERATURE, AND CONSTRUCTION QUALITY AS THE SPECIFIED FIXTURE. PRIOR TO
SUBSTITUTION REQUEST, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PRODUCE A POINT BY POINT LIGHTING PLAN DANIEL T. MERRITTS, PLS
WITH STATISTICAL SUMMARY TABLE TO VERIFY THAT THE PROPOSED SUBSTITUTION ACHIEVES THE IESNA 394 BEDFORD ROAD
RECOMMENDATIONS AND/OR LIGHT LEVELS/STATISTICAL SUMMARY NOTED ON THE LIGHTING PLAN WITHOUT PLEASANTVILLE, NY 10570
REQUIRING CHANGES TO THE SITE PLAN, LIGHT LOCATIONS OR ARCHITECTURE, AND OBTAINS OWNER APPROVAL. THIS
POINT BY POINT PLAN AND STATISTICAL SUMMARY TABLE SHALL BE INCLUDED WITH THE SUBMITTAL. FAILURE TO
COMPLY WITH THIS REQUIREMENT WILL RESULT IN THE RETURN OF THE SUBMITTAL AS REJECTED. WETLAND CONSULTANT
6. THE CONTRACTOR SHALL ALSO OBTAIN WRITTEN VERIFICATION FROM THE MUNICIPALITY THAT THE CHANGES DO NOT
TIM MILLER ASSOCIATES, INC.
PROPERTY LINE, REQUIRE AN AMENDMENT OR REAPPROVAL OF THE APPROVED SITE PLAN AND/OR ARCHITECTURAL BUILDING PLAN
TYP. APPROVALS. 10 NORTH STREET
COLD SPRING, NY 10516
LIGHTING
CALCULATIONS
PARKING
AVERAGE 1.3
MAX 34
PROPERTY LINE,
0.0
(TYP.) 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0
MIN 3.4
UNIFORMITY
PT1 30' SIDE YARD SETBACK/ RATIO 2.6:1
4W NONDISTURBANCE AREA
0.1 0.2 0.2 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
PT2 ENTRANCE DRIVE
4W
Λ Λ
Λ
PT3
Λ Λ
Λ
Λ Λ
0.1 0.5 1.2 0.9 0.9 0.8 0.3 0.3 0.3 0.2 0.2 0.1Λ Λ 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.0Λ Λ 0.0 0.0 0.0 0.0 0.0 0.0 0.0
AVERAGE 0.7
Λ Λ Λ Λ
Λ
4W
Λ Λ Λ
PT4
Λ Λ Λ
Λ Λ Λ
Λ
Λ
Λ Λ
MAX 1.4
Λ
4W
Λ0.0
0.1 0.5 1.2 0.9 1.1 1.0 0.4 0.4 1.2 1.3 1.1 1.1 0.5 0.4 0.7 0.6 0.1 0.2 0.1 Λ 0.0 Λ 0.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.7 1.3 1.0 0.7 0.5 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Λ
Λ Λ Λ
Λ
Λ
PT5
Λ Λ Λ Λ
MIN 0.1
Λ Λ Λ
Λ
4W
Λ
Λ
Λ
0.0 0.1 0.4 0.5 0.5 0.6 0.7 0.3 0.4 1.0 0.9 0.9 1.1 0.4 0.4 0.9 1.2 1.1 1.4 0.6 0.2 0.3 0.9 0.8 0.2 0.3 0.1 0.1 Λ0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.8 1.9 1.3 0.9 0.7 0.7 0.7 0.5 0.0 0.0 0.0 0.0 0.0 0.0
Λ
UNIFORMITY
Λ
Λ
Λ
Λ
Λ
RATIO 7.0:1
Λ
Λ Λ Λ
Λ 0.1 Λ
PT6
0.0 Λ
0.1 0.1 0.2 0.2 0.3 0.2 0.3 0.4 0.4 0.4 0.7 0.3 0.3 0.8 0.7 0.8 1.1 0.5 0.2 0.4 1.0 1.0 1.1 1.3 0.5 0.3 0.6 0.8 0.2 0.2
Λ Λ Λ0.1 0.0 0.0 0.0 0.0 0.6 0.0 2.2 1.3 0.9 0.7 0.9 1.1 0.8 0.0 0.0 0.0 0.0 0.0
Λ Λ
Λ
Λ
Λ Λ
DL1
Λ Λ Λ Λ
4W Λ
Λ
Λ
ENTRANCE WALK
Λ Λ Λ
Λ
Λ Λ
Λ
T4M
Λ Λ
Λ
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Λ 0.2 Λ 0.1
Λ 0.2 0.3 0.3 0.3 0.5 0.3 0.1 0.3 0.7 0.6 0.7 1.0 0.4 0.3 0.7 1.3 1.2 1.4 0.7 0.2 0.1 0.0 0.3 0.6 1.6 1.9 1.2 0.9 0.9 1.4 2.0 0.0 0.0 0.0 0.0 0.0 0.0
Λ Λ Λ
AVERAGE 0.8
Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ Λ
Λ
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Λ 0.2 Λ 0.2Λ 0.2 0.3 0.4 0.2 0.3 0.7 0.7 0.9 1.2 0.6 0.3 0.6 1.2 0.7 0.8 1.6 1.5 1.1 0.8 1.2 2.4 3.3 0.0 0.0 0.0 0.0
MAX 1.8
Λ
Λ
Λ Λ Λ
Λ
DL2
Λ Λ
Λ
Λ
Λ
MIN 0.2
Λ
T2M
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.2 0.2 Λ 0.3 0.4 0.7 0.4 0.3 0.7 1.2 1.2 1.7 1.8 1.2 0.9 0.8 1.3 2.6 3.2 0.0 0.0 0.0 0.0
E
Λ
Λ
ENU
Λ
Λ
Λ
Λ
UNIFORMITY
Λ Λ
Λ Λ
Λ 0.2
Λ
Λ 0.5
RATIO 4:1
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.5 0.6 0.8 1.2 1.1 0.8 0.7 0.8 1.2 1.9 1.9 0.7 0.7 0.0 0.0 0.0 0.0 0.0
Λ
E AV
Λ Λ
Λ Λ
Λ
Λ Λ
Λ Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
YETT
Λ0.1 Λ 0.3
Λ
0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.7 0.8 0.8 0.8 1.0 1.4 1.2 1.6 1.0 0.6 0.4 0.4 0.0 0.0 0.0 0.0
DL4 PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
Λ Λ
1-800-962-7962 OR 811
Λ Λ
Λ
T2M
Λ
DL8
Λ
LAFA
Λ
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.9 1.0 1.0 1.3 1.4 1.8 2.1 2.8 0.0 2.8 1.3 0.7 0.5 0.5 0.4 0.3 0.1 0.0 0.0
Λ
Λ
T2M
Λ
Λ
Λ
Λ
Λ
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.7 1.2 1.4 1.4 1.4 1.5 1.7 2.1 3.3 3.4 2.2 1.0 3.0 3.2 1.5 0.8 0.8 0.8 0.7 0.3 0.1 0.0 0.0
Λ
Λ
Λ
Λ
DL6
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.7 1.6 2.1 2.0 1.6 1.5 1.3 1.4 2.1 2.1 1.7 1.2 0.8 0.7 0.8 2.3 1.9 1.1 0.9 1.4 1.6 1.2 0.3 0.1 0.0
T2M
Λ
Λ
Λ
Λ0.4
Λ
0.0 0.0 0.0 0.0 0.0 0.1 0.8 1.8 2.2 1.9 1.3 0.8 0.7 1.0 1.4 1.5 1.3 1.2 1.1 1.2 1.7 3.1 3.2 1.2 1.0 0.8 1.0 1.6 2.2 1.4 0.3 0.1 0.0
Λ
DL9
X
DL3
Λ
Λ
Λ
T4M T3M
Λ 0.5
Λ
0.0 0.0 0.0 0.1 0.1 0.3 0.8 1.3 1.0 0.6 0.6 0.9 1.4 1.8 1.7 1.5 1.2 1.2 1.5 2.4 3.2 2.5 1.3 1.0 0.9 0.7 0.8 1.1 1.7 2.4 1.1 0.2 0.1
X
Λ
NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
Λ
Λ
Λ
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
X
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.4 0.2 0.2 0.4 0.8 1.8 2.3 2.0 1.5 1.0 0.9 1.1 1.4 1.7 1.5 1.2 1.0 0.9 0.8 0.8 0.9 1.3 1.4 0.5 0.2 0.1
Λ
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.4 0.7 1.9 2.0 1.2 0.8 0.7 0.7 0.8 1.0 1.3 1.3 1.2 1.1 0.9 0.8 0.8 0.8 0.5 0.2 0.1 0.1
Λ
DL5
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.4 T3M
0.5 0.4 0.4 0.4 0.5 0.7 1.0 1.5 1.7 1.7 1.3 1.1 0.8 0.7 0.5 0.3 0.1 0.1
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
Λ
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.1 0.1 0.2 0.3 0.5 1.0 2.0 2.3 2.0 1.4 0.9 0.7 0.6 0.4 0.2 0.1 0.0 SHOWN BY THESE DRAWINGS.
Λ
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
DL7
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.2 0.4 0.9 1.9 1.8 1.1 0.7 0.5 0.4 0.2 0.1 0.1
T3M 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Λ
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.5 0.4 0.4 0.4 0.3 0.2 0.1 0.1 0.0
30' FRONT YARD SETBACK Copyright DTS Provident Design Engineering, LLP 2025
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0
All rights reserved.
0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0
NOT FOR CONSTRUCTION
30' FRONT YARD SETBACK
0.0 0.0 0.0 0.0 0.0
1 01/21/2026 SITE PLAN APPLICATION
2 02/18/2026 ISSUE TO PLANNING BOARD
3 03/25/2026 ISSUE TO PLANNING BOARD
AD
D RO
ON 02
O MP E 35/2
C R O UT
R
PARCEL 3 -
SITE LIGHTING PLAN
30.0
'
SP-5.1
CONKLIN
AVENUE
PROPERTY LINE
(TYP.)
Page 94
NOTES:
1. PER TOWN OF CORTLANDT ZONING CODESECTION 307-12.3 G.
(2):SHOULD ANY OUTDOOR LIGHTING FIXTURE OR THE TYPE OF
LIGHT SOURCE THEREIN BE CHANGED AFTER A LIGHTING
LIGHT POLES AND FIXTURES PERMIT AND/OR SITE PLAN APPROVAL HAS BEEN ISSUED, A
SHALL BE AS CHANGE REQUEST MUST BE SUBMITTED TO THE DIRECTOR OF
MANUFACTURED BY CODE ENFORCEMENT FOR REVISED APPROVAL.
ARCHITECTURAL LIGHTING AND
ARE AS NOTED: 2. THE PHOTOMETRIC PLAN AND LIGHTING DETAILS HAVE BEEN
SUBMITTED TO AND APPROVED BY TOWN OF CORTLANDT.
POLE MODEL: SUBSTITUTIONS SUBMITTED FOR APPROVAL REVIEW BY
DB12-4F14-188-BLT-PTF PROJECT ENGINEER MUST HAVE SAME FIXTURE STYLE,
WATTAGE, COLOR TEMPERATURE, AND CONSTRUCTION
EVERGREEN MANOR
DB12 DECORATIVE POLE
MOUNTING HEIGHT 10'-6" QUALITY AS THE SPECIFIED FIXTURE. PRIOR TO SUBSTITUTION
COLOR: BLACK REQUEST, IT IS THE CONTRACTOR'S RESPONSIBILITY TO
PRODUCE A POINT BY POINT LIGHTING PLAN WITH
FIXTURE: PROVIDENCE MEDIUM STATISTICAL SUMMARY TABLE TO VERIFY THAT THE
LAMP TYPE: 36 LED
FIXTURE COLOR: BLACK MATTE
PROPOSED SUBSTITUTION ACHIEVES THE IESNA
RECOMMENDATIONS AND/OR LIGHT LEVELS/STATISTICAL Town of Cortlandt, New York
LENS STYLE: CLEAR LENS SUMMARY NOTED ON THE LIGHTING PLAN WITHOUT
GLOBE MATERIAL: ALUMINUM REQUIRING CHANGES TO THE SITE PLAN, LIGHT LOCATIONS OR
SENSOR CONTROL TO TURN OFF ARCHITECTURE, AND OBTAINS OWNER APPROVAL. THIS POINT
BY POINT PLAN AND STATISTICAL SUMMARY TABLE SHALL BE
10' or 14'
AT DAWN AND ON AT DUSK
INCLUDED WITH THE SUBMITTAL. FAILURE TO COMPLY WITH
THIS REQUIREMENT WILL RESULT IN THE RETURN OF THE
SUBMITTAL AS REJECTED.
3. THE CONTRACTOR SHALL ALSO OBTAIN WRITTEN
VERIFICATION FROM THE MUNICIPALITY THAT THE CHANGES
BOLT PATTERN TO MATCH POLE DO NOT REQUIRE AN AMENDMENT OR REAPPROVAL OF THE
ANCHOR BOLT TEMPLATE APPROVED SITE PLAN AND/OR ARCHITECTURAL BUILDING PLAN
APPROVALS.
1-1/2" x 1-1/2" CHAMFER 4. SUBMIT CUT SHEETS/SHOP DRAWINGS OF FOOTINGS, POLES
CENTERLINE POLE CL AND FIXTURES TO PROJECT ENGINEER FOR REVIEW AND
18" PLANTED AREA APPROVAL PRIOR TO PLACEMENT OF ORDERS.
CONCRETE WALKWAY 5. POLES MUST BE CENTERED ON POLE BASES OR THEY WILL BE
REJECTED. OWNER / APPLICANT
6"
6" 6. ANY LIFTING POINTS OR OTHER BASE INDENTATIONS SHALL BE V.S. CONSTRUCTION CORPORATION
FILLED WITH CONCRETE AND SMOOTHED TO MATCH BASE.
CL 37 CROTON DAM ROAD
4000 PSI CIRCULAR 7. DO NOT ERECT POLES WITHOUT HAVING FIXTURES INSTALLED.
24" LONG ANCHOR BOLTS 24"
CONCRETE FOOTING
OSSINING, NY 10562
PER MANUFACTURER'S 8. FACTORY SUPPLIED TEMPLATES MUST BE USED WHEN
INSTALLATION INSTRUCTIONS SETTING ANCHOR BOLTS.
FOUNDATION - SEE DETAIL 5 COMPACTED SUBGRADE 9. SEE LIGHTING SCHEDULE FOR ADDITIONAL INFORMATION.
CONTRACTOR TO VERIFY THAT QUANTITIES AND TYPES OF PLANNER, CIVIL ENGINEER, LANDSCAPE
FIXTURES, POLES AND BASES IN THE SCHEDULE ARE IN
CONFORMANCE WITH WHAT IS SHOWN ON PLANS. ARCHITECT
DTS P O DENT
POST TOP LIGHT ntelligent Land se
3
SCALE: N.T.S.
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
P: 914.428.0010
GROUND LUG HANDHOLE - FUSED CONNECTION
AT EVERY POLE
F: 914.428.0017
ATTACHED TO POLE
BOND ALL CONDUITS TO POLE, POLE
BASE AND GROUND LUG ARCHITECT - PARCEL 3
ACORN NUTS, TYP. BEATTY HARVEY COCO ARCHITECTS
6"
COVER 1300 WALT WHITMAN ROAD
1" X 1" CHAMFER MELVILLE, NY 11747
POLE BASE FLANGE
ANCHOR BOLT, SIZE SPECIFICATION &
LAND USE ATTORNEY
30" FOR AREA
DOWNLIGHTS
TOP LIGHTS;
6" FOR POST
INSTALLATION AS RECOMMENDED BY
ZARIN & STEINMETZ
18"
MANUFACTURER.
1'-0" MIN.
81 MAIN STREET
FINISHED GRADE (TURF OR PAVEMENT)
WHITE PLAINS, NY 10601
INSULATED BONDING AND GROUNDING SURVEYOR
CAD WELD
BUSHING 2" GALVANIZED STEEL CONDUIT
2" PVC CONDUIT DANIEL T. MERRITTS, PLS
5'-0" MIN. BELOW FINISHED GRADE
18" BELOW GRADE, NUMBER OF CONDUITS
AS REQUIRED 394 BEDFORD ROAD
8" GRD WIRE
IN
PLEASANTVILLE, NY 10570
5/8" x 10' LONG
SEAL AFTER
COPPER CLAD
GROUND ROD
WIRING NOTES:
1. SUBMIT CUT SHEETS/SHOP DRAWINGS OF WETLAND CONSULTANT
FOOTINGS TO PROJECT ENGINEER FOR REVIEW
4000 PSI PRECAST AND APPROVAL PRIOR TO INSTALLATION. TIM MILLER ASSOCIATES, INC.
ROUND CONCRETE 2. VERIFY POLE BASE COVER DIMENSIONS AND
FOOTING NO. 4 REBAR ANCHORAGE PRIOR TO POLE BASE 10 NORTH STREET
LAPPED 24" FABRICATION. COLD SPRING, NY 10516
3. POLES NOT CENTERED ON BASE WILL BE
#4 REBAR REJECTED.
HOOP 4. SEE LIGHTING SCHEDULE FOR ADDITIONAL
2'-0" MAX POLE AND FIXTURE INFORMATION.
1'-0" O.C.
5. SEE SITE LIGHTING PLAN FOR POLE LOCATIONS.
6. SEE ELECTRICAL PLANS FOR CIRCUITRY
3"
INFORMATION.
4" GRAVEL BASE
COMPACTED SUBGRADE
24"
POST TOP LIGHT FIXTURE POST TOP LIGHT POLE LIGHT POLE FOUNDATION
1 2 4
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
LIGHT POLES AND FIXTURES SHALL BE AS
MANUFACTURED BY GARDCO LIGHTING
OR EQUAL AS APPROVED BY PROJECT ENGINEER
AND ARE AS NOTED:
POLE MODEL: SRA-STB-4-188-12-D1-BK
(12' SHAFT, 4" STRAIGHT ROUND ALUMINUM WITH
STEEL TENON BASE)
POLE COLOR: BLACK
FIXTURE: MODEL PUREFORM P15 SMALL SQUARE LED
LAMP TYPE: 2700K COLOR, 80 CRI
FIXTURE COLOR: BLACK
PER TOWN OF CORTLANDT ZONING CODE SECTION
307-12.3 G. (2):
SHOULD ANY OUTDOOR LIGHTING FIXTURE OR THE
TYPE OF LIGHT SOURCE THEREIN BE CHANGED
AFTER A LIGHTING PERMIT AND/OR SITE PLAN THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
APPROVAL HAS BEEN ISSUED, A CHANGE REQUEST 1-800-962-7962 OR 811
15'
MUST BE SUBMITTED TO THE DIRECTOR OF CODE
CENTERLINE POLE ENFORCEMENT FOR REVISED APPROVAL.
BOLT PATTERN TO MATCH POLE
ANCHOR BOLT TEMPLATE
CL
ANCHOR BOLTS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS 30"
PLANTED AREA
FINISHED GRADE FACE OF CURB NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
30"
OF PLANTED AREA CL BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
ASPHALT PAVEMENT DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
4000 PSI CIRCULAR WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
CONCRETE FOOTING FOUNDATION - SEE DETAIL 5 DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
COMPACTED SUBGRADE SHOWN BY THESE DRAWINGS.
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
24" YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
AREA DOWNLIGHT NOT FOR CONSTRUCTION
8
SCALE: N.T.S.
1 01/21/2026 SITE PLAN APPLICATION
ELECTRICAL SITE LIGHTING NOTES:
2 02/18/2026 ISSUE TO PLANNING BOARD
1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND WESTCHESTER
COUNTY RULES, LAWS AND REGULATIONS. 3 03/25/2026 ISSUE TO PLANNING BOARD
2. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE REQUIREMENTS OF THE WORK AS REQUIRED BY OSHA
REGULATIONS.
3. THE CONTRACTOR SHALL REVIEW ALL OF THE SITE CONDITIONS PRIOR TO THE SUBMISSION OF THEIR BID TO OWNER.
ANY CLARIFICATIONS REQUIRED BY THE CONTRACTOR SHALL BE SUBMITTED TO OWNER FOR RESPONSE, PRIOR TO
FINALIZATION OF BID SUBMISSIONS.
4. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE FULL SCOPE OF THE WORK, AND SHALL SUBMIT BIDS
THAT REFLECT THE REQUIRED SCOPE OF WORK TO COMPLETE THE WORK.
5. ALL NEW LIGHT POLE BASES SHALL BE PRECAST CONCRETE TYPE, SUITABLE FOR THE PROPOSED LIGHT POLE AND
FIXTURE ASSEMBLIES REQUIRED AT EACH LOCATION. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED
EXCAVATION, PAVEMENT REPAIR, AND REMOVAL OF SOIL SPOILS AS A PART OF THE WORK.
6. ALL NEW LIGHT POLES AND LIGHT FIXTURES SHALL BE GROUNDED, IN ACCORDANCE WITH THE NATIONAL ELECTRIC
CODE. GROUND CONDUCTORS WILL ALL TIE BACK INTO THE PANELBOARD GROUND BAR WHERE THE CIRCUIT IS
PARCEL 3 -
DERIVED.
SITE LIGHTING DETAILS
7. ALL NEW LIGHT FIXTURES SHALL BE EQUIPPED WITH FUSE CUT OUTS, ACCESSIBLE IN THE HAND HOLE OF EACH LIGHT
POLE. FIXTURES SHALL BE INDIVIDUALLY FUSED. CARTRIDGE FUSES SHALL BE PROVIDED FOR EACH INDIVIDUAL
FIXTURE, CARTRIDGE FUSES SHALL BE SIZED FOR 125% OF FULL LOAD CURRENT OF EACH FIXTURE.
8. PROVIDE A WARNING TAPE ABOVE ALL SITE LIGHTING CONDUIT PATHWAYS, YELLOW BACKGROUND, BLACK
LETTERING, 4" WIDE, STATING: WARNING ELECTRIC BELOW. WARNING TAPE SHALL BE EQUIPPED WITH COPPER
TRACING STRIP. INSTALL 12" BELOW FINISHED GRADE.
9. SEE ELECTRICAL DRAWINGS FOR LIGHTING CIRCUITS AND CONDUIT LAYOUT.
AREA DOWNLIGHT FIXTURE
SCALE: N.T.S.
5
AREA DOWNLIGHT FIXTURE
SCALE: N.T.S.
6
AREA DOWNLIGHT POLE
SCALE: N.T.S.
7
ELECTRICAL SITE LIGHTING NOTES
SCALE: N.T.S.
9 SP-5.2
Page 95
JOINT DETAIL
JOINT SEALANT 1/2 "
1/4" X 1/2" SCORED JOINT WITH TOOLED EDGES
EVERY 5 LINEAR FEET FOR 5' WIDE WALKWAYS OR
1/2"
EVERY 6 LINEAR FEET FOR 6' WIDE WALKWAYS OR
EXTEND ASPHALT BASE COURSE INTO EXISTING AS SHOWN ON PLANS
COMPACTED ASPHALTIC CONCRETE PAVEMENT DEPTH 3" OR MATCH EXISTING 3/4" 12" 12"
5'-0" WALKWAY
TOP COURSE, NYSDOT ITEM NO.403.16 6" (OR AS SHOWN AS PLANS)
1 21" LIGHT DUTY
2" HEAVY DUTY NEW PAVEMENT OVERLAY DEPTH 1"
COMPACTED ASPHALTIC CONCRETE
2 21" LIGHT DUTY
3" HEAVY DUTY
EVERGREEN MANOR
BINDER COURSE, NYSDOT ITEM
NO.403.12
SAW CUT OR MATCH EXISTING 4000 PSI CLASS A CONCRETE
WITH LIGHT BROOM FINISH. 1 1
4" x 2" SCORED JOINT WITH 1/2" JOINT
6"
PITCH AS SHOWN TOOLED EDGES 6" FROM
6" X 6" - W2.0 X W2.0 WELDED DOWEL BAR
2 1/2"
ON PLANS 6" 3/4"
1" WIRE MESH (2" MIN. COVER) FACE OF CURB 1/2"
EXPANSION Town of Cortlandt, New York
18"
JOINT
X X X X
5"
PAVEMENT OR
6"
3" STRUCTURE
9" HEAVY DUTY
6" LIGHT DUTY
3'-0" MIN.
5"
12"
18"
8" 9"
EXISTING PAVEMENT NEW PAVEMENT
1'-0"
8" BEDDING COURSE
6"
(SEE DETAIL X ON CD-X.X)
3"
1'-6" MIN.
COMPACTED SUBGRADE 3"
NOTE:
NOTES: #4 BAR (3"MIN.
OWNER / APPLICANT
SUB-BASE COURSE DRAINAGE COURSE SAW CUT INTO EXISTING PAVEMENT APPLIES 1. EXPOSED SURFACES TO HAVE FLOAT FINISH. NOTES: CLEAR ALL SIDES)
V.S. CONSTRUCTION CORPORATION
NYSDOT ITEM NO.304.11 TO PAVEMENT REPLACEMENT AT UTILITY 1. EXPANSION JOINTS WITH JOINT SEALANT TO BE SPACED AT 20' O.C. 4" PERF. PVC UNDERDRAIN WHERE SHOWN
4" PERF. PVC 5' TRENCHES EXTENDING INTO R.O.W. FOR 5' WIDE WALKWAYS AND 24' O.C. FOR 6' WIDE WALKWAYS 37 CROTON DAM ROAD
2. PROVIDE 12" PREMOLDED EXPANSION JOINT AND SEALANT EVERY 20' O.C. 2. PROVIDE 1/2" EXPANSION JOINT WITH SEALANT BETWEEN ABUTTING ON PLANS OR WHERE DIRECTED BY
COMPACTED SUBGRADE MIN. @ CATCH
CONCRETE WALKWAYS, CONCRETE CURBS, BUILDINGS AND OTHER PROJECT ENGINEER OR WHERE AREAS OF OSSINING, NY 10562
BASIN
3. PROVIDE 12" PREMOLDED EXPANSION JOINT AND SEALANT WHEN CONCRETE PAVEMENT ABUTS CONCRETE CURB. STRUCTURES. GROUNDWATER ENCOUNTERED;
UNDERDRAIN WHERE SHOWN ON PLANS 3. INTEGRAL CURB AND SIDEWALK TO BE INSTALLED WHEREVER CONNECT TO STORM DRAIN
OR CONDITIONS OF GROUND WATER ARE CONCRETE CURB AND CONCRETE SIDEWALK ARE ADJACENT
OBSERVED AND OR WHERE DIRECTED BY 4. MOUNTABLE CONCRETE CURBS TO BE NYSDOT MODEL M150, 9" WIDE, 2" VERTICAL, 6" EXPOSED REVEAL HEIGHT, 18" TOTAL HEIGHT.
THE ENGINEER. TO BE CONNECTED TO
INCLUDING AT ACCESSIBLE RAMPS (WHERE CURB WOULD BE FLUSH
WITH GRADE PER PEDESTRIAN RAMP DETAILS). PLANNER, CIVIL ENGINEER, LANDSCAPE
THE STORM DRAIN SYSTEM.
ARCHITECT
DTS PROVIDENT
ASPHALT PAVEMENT - LIGHT/HEAVY DUTY SAWCUT PAVEMENT KEY-IN CONCRETE CURB CONCRETE SIDEWALK WITH INTEGRAL CURB Intelligent Land Use
1 2 3 4
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
NOTE:
FOR ALL SIDEWALKS AND RAMPS, P: 914.428.0010
SEE NYS DOT SHEET NUMBER 608-01 "SIDEWALK CURB RAMP F: 914.428.0017
DETAILS (TOTAL OF 9 SHEETS)" EFFECTIVE DATE 05/01/16.
NON-PAVED
ARCHITECT - PARCEL 3
1/4" X 1/2" SCORED JOINT WITH TOOLED EDGES EVERY 5 LINEAR 12" STRIPING (TYP.) SURFACE
FEET FOR 5' WIDE WALKWAYS OR EVERY 6 LINEAR FEET FOR 6' @ 2' SPACING 2'-0" (TYP.) BEATTY HARVEY COCO ARCHITECTS
WIDE WALKWAYS OR AS SHOWN ON PLANS DETECTABLE WARNINGS TO EXTEND 1300 WALT WHITMAN ROAD
4000 PSI CONCRETE
4000 PSI CLASS A CONCRETE WITH 6'-0" FULL WIDTH OF RAMPS. MELVILLE, NY 11747
HERCULITE CAST-IN-PLACE REPLACEABLE
12"
LIGHT BROOM FINISH. NON-PAVED
2% (TYP.)
DETECTABLE WARNINGS TO EXTEND TILES AS MANUFACTURED BY ARMOR-TILE
EDGE OF SURFACE
6" X 6" - W2.0 X W2.0 WELDED WIRE PAVEMENT
WALKWAY 1:13 MAX WALKWAY FULL WIDTH OF RAMPS. 1-800-682-2525 OR APPROVED EQUAL; LAND USE ATTORNEY
RAMP 7.5% MAX
6'-0"
1:13 MAX HERCULITE CAST-IN-PLACE REPLACEABLE 24" X 60" TILES; DARK GRAY COLOR;
MESH (2" MIN. COVER) TILES AS MANUFACTURED BY
6'-0" MIN.
ARMOR-TILE ALIGN DOMES IN SQUARE GRID IN ZARIN & STEINMETZ
BEDDING COURSE (SEE SOILS 1-800-682-2525 OR APPROVED EQUAL; PRIMARY DIRECTION OF TRAVEL.
81 MAIN STREET
7'-0"
JOINT DETAIL 24" X 60" TILES; DARK GRAY COLOR; ALL ADA DETECTABLE TACTILE DOMES
24"
MATERIALS NOTES DETAIL) ALIGN DOMES IN SQUARE GRID IN
COMPACTED SUBGRADE
PRIMARY DIRECTION OF TRAVEL. SHALL BE "MADE IN THE USA" AND BE RED WHITE PLAINS, NY 10601
ALL ADA DETECTABLE TACTILE DOMES IN COLOR.
JOINT SEALANT 1/2 " 7'-0" 5'-0" 7'-0"
SHALL BE "MADE IN THE USA" AND BE
2 1/2"
TYP.
24"
RED IN COLOR.
SURVEYOR
6"
UNLESS SHOWN
1/2"
12"
OTHERWISE ON PLANS
PLAN CONCRETE CURB
GRADE BREAK AT BOTTOM OF RAMP DANIEL T. MERRITTS, PLS
X X X X X 12" 12" 1'-0" (TYP.) 394 BEDFORD ROAD
5"
1'-0" (TYP.) (TRANSVERSE LINES)
CONCRETE DROP CURB
PLEASANTVILLE, NY 10570
5"
TOP OF CURB
COMBINED NOTES:
1/2" JOINT BOTTOM OF CURB
1. ALL CONCRETE WALKS AND 2'-0"
ROADWAY WETLAND CONSULTANT
DOWEL BAR TYPE LS
TYP.
RAMPS SHALL BE 4000 PSI PLAN VIEW
TIM MILLER ASSOCIATES, INC.
6"
1/2" EXPANSION ELEVATION CONCRETE.
JOINT DETECTABLE WARNING DETAILS 2. SEE CONCRETE WALK DETAIL(S)
10 NORTH STREET
RAMP WITHIN WALKWAY FOR ADDITIONAL INFORMATION. FLUSH
PAVEMENT OR CURB COLD SPRING, NY 10516
1.6"-2.4"
STRUCTURE NOTES: FLUSH
TOP DIAMETER 50-65% (BEYOND)
1. ALL CROSSWALK MARKINGS SHALL BE WHITE AND RETROREFLECTIVE REQUIREMENTS OF THE BASE DIAMETER
TOP OF CURB
BOTTOM OF CURB
2. CROSSWALK SHALL MEET NYSDOT STANDARD SPECIFICATIONS
BASE DIAMETER
0.2"
A ROAD CURB RAMP
0.9"-1.4"
ROAD CURB RAMP ELEVATION
NOTES: .65" min.
NOTES: 1.6"-2.4"
UNDERDRAIN WHERE CONDITIONS OF 1. ALL CONCRETE WALKS AND
1. EXPANSION JOINTS WITH JOINT SEALANT TO BE SPACED AT 20' O.C.
GROUND WATER ARE OBSERVED AND/OR RAMPS SHALL BE 4000 PSI
PLAN VIEW ELEVATION - ENLARGED
FOR 5' WIDE WALKWAYS AND 24' O.C. FOR 6' WIDE WALKWAYS. SECTION A
WHERE DIRECTED BY THE ENGINEER. TO CONCRETE.
2. PROVIDE 1/2" EXPANSION JOINT WITH SEALANT BETWEEN CONCRETE
BE CONNECTED TO THE STORM DRAIN
NOTE:
WALKWAYS AND CONCRETE CURBS AND STRUCTURES. 2. SEE CONCRETE WALK DETAIL(S) ALL ADA DETECTABLE TACTILE DOMES SHALL BE
SYSTEM SECTION A FOR ADDITIONAL INFORMATION. "MADE IN THE USA" AND BE RED IN COLOR
CONCRETE PAVEMENT (SIDEWALK) PEDESTRIAN CROSSWALK CURB RAMP CURB RAMP
5 6 7 8
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
NO. DESCRIPTION IMAGE MUTCD NO. SIZE
1 NO PARKING 1
3
2 SIGN #R7-1 2
SIGN
1
SIGN POSTS TO BE
STOP R1-1C 30"X30" PUNCHED FULL LENGTH PANEL
SIGN WITH NEW YORK
WITH 38" DIAM. HOLES, Z-BAR
STATE SYMBOL OF
1" ON CENTER, WITH STRINGER PLASTIC
ACCESSIBILITY, MUTCD
2
PAVED WALKWAY PEDESTRIAN FIRST HOLE 1" FROM TOP WASHER
#R7-8 ABOVE "VAN W11A-2 30"X30" 5
RAMP DOWN RAMP DOWN CROSSING 1'-16 "
ACCESSIBLE" SIGN #R7-8A
7.5% MAX TYP. EACH ACCESSIBLE 7.5% MAX SIGN
PARKING SPACE DOWNWARD POST
3
PER
DIAGONAL ARROW W16-7P 24"X12" 3'-21 " STANDARD
7'-0" 7'-0" CURB (PLAQUE)
FLUSH SHEET
RESERVED
DESIGN MOMENT: 1750 FT*LBS
PARKING PLAN BEND BOLTS STEEL
4
(1'-78" - 3 LB/FT
16" - 4 LB/FT
RESERVED PARKING/ 12"X18" & OR BLUR THREADS BOLT
SIGN POST)
BASE POST
R7-8 + R7-8P
VAN ACCESSIBLE 12"X6" THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
VAN SIGN PANEL CONNECTION PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
ACCESSIBLE 1-800-962-7962 OR 811
NO
5
1'-15
PARKING
NO PARKING ANY TIME ANY TIME R7-1 12"X18"
DO NOT CENTROID OF SIGN
6 DO NOT ENTER
ENTER
R5-1 30"X30"
SIGN
ASSEMBLY
4" WIDE BLUE POST 4" ALLOW. PROTRUSION
STRIPING (TYP) AT RESERVED ABOVE GROUND SURFACE SIGN POST
SIGNS SHALL BE MIN. 7'-0"
7
PARKING
45° ANGLE, 2' O.C. ELECTRIC VEHICLE 3 LB/FT
N/A 12"X18"
18'-0"
CLEAR TO THE BOTTOM OF PARKING ELECTRIC VEHICLE
CHARGING ONLY
RIB-BAK
SIGN; ACCESSIBLE SIGN
7'-0" MIN.
LOCKNUT
HEIGHT
SHALL BE A MIN. OF 70 NO NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
SQUARE INCHES.
8 NO PARKING FIRE
LANE
PARKING
FIRE
LANE N/A 12"X18"
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
2'
SYMBOL OF NEW YORK STATE WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
3'-0" ACCESSIBLE PARKING -
SHEAR WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
BLUE ON WHITE BACKGROUND
MARION PIN MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
NOTES: MINUTE MAN DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
BASE POST ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
CHANNEL SET REFLECTIVE TRAFFIC SAFETY PANELS IN ALL BREAKAWAY 4 LB/FT SHOWN BY THESE DRAWINGS.
3'-0"
PEDESTRIAN CROSSING AND STOP SIGN POSTS PER SYSTEM RIB-BAK
EMBEDMENT
BASE LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
MANUFACTURER'S INSTALLATION INSTRUCTIONS, REFLECTIVE
38" MIN.
ELEVATION YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
YELLOW PANEL FOR PEDESTRIAN CROSSING SIGNS; POST MARION MINUTE MAN CONNECTION DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
REFLECTIVE RED PANEL FOR STOP SIGNS 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
9'-0" 8'-0" MIN. 9'-0"
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
ACCESSIBLE PARKING WITH CURB RAMP SIGN SCHEDULE AND TRAFFIC SIGN POST NOT FOR CONSTRUCTION
10 11 12
SCALE: N.T.S. SCALE: N.T.S.
1 01/21/2026 SITE PLAN APPLICATION
2 02/18/2026 ISSUE TO PLANNING BOARD
3 03/25/2026 ISSUE TO PLANNING BOARD
PARCEL 3 -
SITE AND UTILITY DETAILS
9 13 14 15 SP-6.1
Page 96
B 2.1 SOIL MATERIALS (SEE SPECIFICATIONS FOR COMPETE SOIL MATERIAL AND EARTHWORK INFORMATION)
END SECTION RIPRAP PAD SIZING (TYP)
4'-0" A. GENERAL: PROVIDE BORROW SOIL MATERIALS WHEN SUFFICIENT SATISFACTORY SOIL MATERIALS ARE NOT AVAILABLE FROM EXCAVATIONS. La = LENGTH OF RIP RAP PAD
PAVEMENT
B. SATISFACTORY SOILS: SOIL CLASSIFICATION GROUPS GW, GP, GM, SW, AND SP ACCORDING TO ASTM D 2487, OR A COMBINATION OF THESE (SEE DETAIL 3/DWG SP-4.1) d = PIPE DIAMETER
GROUPS; FREE OF ROCK OR GRAVEL LARGER THAN 3 INCHES IN ANY DIMENSION, DEBRIS, WASTE, FROZEN MATERIALS, VEGETATION, AND OTHER w = 3*D + LA
A A DELETERIOUS MATTER.
COMPACTED GRANULAR SUBBASE
(SEE DETAIL 4/DWG. SP-4.1) La = 10'
C. UNSATISFACTORY SOILS: SOIL CLASSIFICATION GROUPS SM, GC, SC, CL, ML, OL, CH, MH, OH, AND PT ACCORDING TO ASTM D 2487, OR A
d= 1.25'
EVERGREEN MANOR
COMBINATION OF THESE GROUPS.
C.A. UNSATISFACTORY SOILS ALSO INCLUDE SATISFACTORY SOILS NOT MAINTAINED WITHIN 2 PERCENT OF OPTIMUM MOISTURE CONTENT AT TIME TOPSOIL OR REINFORCED TURF w= 13.75, BUILD AS 14.00'
OF COMPACTION PITCH AS SHOWN ON PLANS (SEE DETAIL 3/DWG /SP-4.1)
D. SUBBASE MATERIAL: NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, AND NATURAL OR
CRUSHED SAND; ASTM D 2940; WITH AT LEAST 90 PERCENT PASSING A 1-21" (37.5-MM) SIEVE AND NOT MORE THAN 5 PERCENT PASSING A NO. 200
PITCH AS SHOWN ON PLANS Town of Cortlandt, New York
B (0.075-MM) SIEVE.
PLAN
E. BASE COURSE: NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, AND NATURAL OR CRUSHED
SAND; NYSDOT ITEM 304.11. RECYCLED MATERIAL (BUILDING AND ROAD DEMOLITION MATERIAL AND RECYCLED MATERIAL CONSISTING OF BRICK,
MIN. COVER
TOP OF CASTING LEVEL CEMENT CONCRETE, OR OTHER MATERIALS) MAY NOT BE USED WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER.
WITH TOP OF CURB GEOTEXTILE FABRIC ENCIRCLING
2'-0"
F. ENGINEERED FILL: NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, AND NATURAL OR STONE SURROUND MIRAFI 140 N
6"
4'-0" CONC. CURB
CRUSHED SAND; ASTM D 2940; WITH AT LEAST 90 PERCENT PASSING A 1-21" (37.5-MM) SIEVE AND NOT MORE THAN 12 PERCENT PASSING A NO. 200 6" DIAMETER PERFORATED SDR-35
(0.075-MM) SIEVE. PVC PIPE CENTERED IN 6" OF
CRUSHED STONE; SLOPE TO DRAIN
2 COURSES MASONRY BRICK G. BEDDING COURSE: NATURALLY OR ARTIFICIALLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, AND NATURAL OR (AS PER PLAN OR DIRECTED BY
FOR LEVELING PURPOSES CRUSHED SAND; ASTM D 2940; EXCEPT WITH 100 PERCENT PASSING A 1-INCH (25-MM) SIEVE AND 0 TO 5 PERCENT PASSING A NO.8 (2.36-MM) SIEVE. PAVEMENT THE TOWN ENGINEER) PAINTED AREA
PLASTIC COATED
STEEL STEPS H. DRAINAGE COURSE: NARROWLY GRADED MIXTURE OF WASHED CRUSHED STONE, OR CRUSHED OR UNCRUSHED GRAVEL; ASTM D 448;
INVERT CONFORMING TO NYSDOT COARSE-AGGREGATE GRADING SIZE 57; WITH 100 PERCENT PASSING A 1-21 " (37.5-MM) SIEVE AND 0 TO 5 PERCENT PASSING A NO.8 (2.36-MM) SIEVE. 12" x 12" - DRAINAGE
SECTION 725-02 MATERIAL OWNER / APPLICANT
12"
6"
I. FILTER MATERIAL: NARROWLY GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, OR CRUSHED STONE AND NATURAL SAND; ASTM D 448;
OUTLET PIPE
COARSE-AGGREGATE GRADING SIZE 67; WITH 100 PERCENT PASSING A 1" (25-MM) SIEVE AND 0 TO 5 PERCENT PASSING A NO.4 (4.75-MM) SIEVE.
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
SUMP
J. TRAP ROCK: NARROWLY GRADED MIXTURE OF WASHED CRUSHED STONE ASTM D 448; CORASE-AGGREGATE GRADING SIZE 1; WITH 100 PERCENT
18"
PASSING A 4-INCH (100-MM) SIEVE AND 0 TO 15 PERCENT PASSING A 1-21" (37.5-MM) SIEVE. NOTE: OSSINING, NY 10562
INSTALL WHERE SHOWN ON THE PLANS OR AS DIRECTED BY THE TOWN ENGINEER
K. SAND: ASTM C 33; FINE AGGREGATE.
12" BEDDING COURSE 6" 3'-0" 6" #4 BARS
L. IMPERVIOUS FILL: CLAYEY GRAVEL AND SAND MIXTURE CAPABLE OF COMPACTING TO A DENSE STATE.
(COMPACTED CRUSHED STONE BASE) 8" O.C.
BOTHWAYS
PLANNER, CIVIL ENGINEER, LANDSCAPE
M. TOPSOIL: SEE SPECIFICATION.
UNDISTURBED SUBGRADE MATERIALS ARCHITECT
SECTION A-A
SCALE: N.T.S.
DTS PROVIDENT
SOIL MATERIAL UNDER DRAIN RIPRAP OUTLET PROTECTION/ENERGY DISSIPATOR Intelligent Land Use
2 3 4
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
DTS Provident Design Engineering, LLP CA #: 0017846
FRAME AND GRATE PATTERN NO. 2540 One North Broadway
FOR CATCH BASIN AS MANUFACTURED White Plains, NY 10601
BY CAMPBELL FOUNDRY, HARRISON,
NEW JERSEY OR APPROVED EQUAL 3'-8" YD P: 914.428.0010
SEE PLAN FOR RIM ELEVATION) CASTING AND COVER SHALL BE EQUAL TO PATTERN
4'-2" DI NO. 1012B AS MANUFACTURED BY CAMPBELL
F: 914.428.0017
2 COURSES MASONRY BRICK 3'-0" YD FOUNDRY CO. HARRISON, N.J. OR APPROVED EQUAL
4"
FOR LEVELING PURPOSES 3'-6" DI TOP OF CASTING = AND STAMPED "DRAIN" ARCHITECT - PARCEL 3
6"
FINISH GRADE
PRECAST REINFORCED CONCRETE
PAVEMENT CONTAINING 4,500 PSI CONCRETE 2 COURSES OF BRICK BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
6"
2' - 11"
8"
#4 BARS
12" O.C. 8" MELVILLE, NY 11747
2'-0" YD
3'-0" YD
2'-6" DI
3'-6" DI
AREA OF CIRCUMFERENTIAL 3'-0" DIA.
BOTHWAYS STEEL 12" SQ. IN / LIN. FT. S.W.D.
PLASTIC COATED STEEL
6"
LAND USE ATTORNEY
6"
6" STEPS CONFORMING TO
6"
NYSDOT SECTION 725-02 ZARIN & STEINMETZ
OUTLET
12"
PIPE
PAVEMENT OR TOPSOIL, SEE PLANS PRECAST CONCRETE RISER 81 MAIN STREET
SECTION AS NEEDED WHITE PLAINS, NY 10601
4"
SUMP WITH GRAVEL PLAN HEAVY DUTY
POCKET FRAME AND GRATE AS
12" BEDDING COURSE
(COMPACTED CRUSHED OUTLET PIPE
MANUFACTURED BY
SEE DTL. "A"
SURVEYOR
CAMPBELL FOUNDRY CAT.
6" 2'-6" 6" STONE BASE)
DANIEL T. MERRITTS, PLS
4'-0" MIN., SANITARY SEWER
NO. 2129B YD / 2816 DI SELF SEALING
2'-0" MIN., STORM DRAIN
4'-6" MIN., WATER MAIN
4 21" DI
4" YD
(H-20 LOADING)
UNDISTURBED
MATERIALS
4'-0" DIA. MIN. 5" RUBBER GASKET 394 BEDFORD ROAD
(TWO PROJECTIONS) DETAIL "A"
ASTM C44360T PLEASANTVILLE, NY 10570
12" MIN.
VARIES
SUMP
18" TO 48"
PIPE
SECTION B-B
WETLAND CONSULTANT
VARIES
PIPE COVER
6" MINIMUM
TOWN OF CORTLANDT CATCH BASIN STANDARD NOTES: 2 COURSES OF BRICK FOR TIM MILLER ASSOCIATES, INC.
8"
A. PRE-CAST WITH MINIMUM INSIDE DIMENSION OF 48” WIDTH AND 30” SUITABLE FOR A CAMPBELL FOUNDRY HEAVY DUTY 7"
BICYCLE SAFE / ADA ACCESSIBLE GRATE (CURB 2617 OR 3407)
FINAL ADJUSTMENT
PIPE O.D. PIPE PIPE O.D. PRECAST CONCRETE 10 NORTH STREET
12" CRUSHED STONE
6" PRECAST CONCRETE BASE RISER SECTION COLD SPRING, NY 10516
6" YD
B. NO MORE THAN 2 COURSES OF SEWER GRADE BRICK AND MORTAR
18"DI
(12" MIN.) (12" MIN.)
MIN.
(TYP.) 0.D. BEDDING COURSE
C. COMPRESSIVE STRENGTH OF ALL CONCRETE STRUCTURES SHALL BE NO LESS THAN 4000 PSI AND HAVING AN AIR 12" COMPACTED CRUSHED " STL. REINF. RODS AT
ENTRAINMENT OF 5% MINIMUM. MINIMUM LOADING SHALL BE AASHTO HS-20 WITH H-25 PROPOSED TO MEET THE 4" 4" UNDISTURBED SUBGRADE
STONE (BEDDING COURSE) 8" O.C. BOTH WAYS
REQUIREMENTS OF A 75,000-POUND FIRE TRUCK AND SIMILAR HEAVY VEHICLES. 6' DIA. MATERIAL
D. MINIMUM DRAINAGE SIZE 15” HDPE PIPE. UNDISTURBED SUBGRADE
MATERIALS
8"
E. BACKFILL / BEDDING (6” ABOVE PIPE) VIRGIN ITEM-4, MEETING NYSDOT MATERIAL SPECIFICATION AND GRADATION
NOTE: NOTE:
REQUIREMENTS. INSITU MATERIAL MAY BE USED AS BACKFILL ABOVE BEDDING AND BELOW FULL DEPTH PAVEMENT.
1. ALL STRUCTURES TO SUPPORT H20 LOADING 6" SQ. 1. ALL STRUCTURES TO SUPPORT H20 LOADING
F. ALL STRUCTURES TO BE DEDICATED TO THE TOWN OF CORTLANDT SHALL HAVE A 12-INCH BEDDING LAYER. SECTION 2. CONCRETE SHALL BE A MINIMUM 4,500 PSI
2. CONTRACTOR TO SUBMIT FABRICATION SHOP
H. CONTRACTOR TO SUBMIT FABRICATION SHOP DRAWINGS FOR APPROVAL 3. CONTRACTOR TO SUBMIT FABRICATION SHOP DRAWINGS
DRAWINGS FOR APPROVAL
FOR APPROVAL
PIPE BEDDING
IMPORTED BEDDING
6" MINIMUM
UNDISTURBED GROUND /
VIRGIN SOIL COURSE MATERIAL
STORM / SEWER / WATER
PIPES
CATCH BASIN CURB TYPE (CB) DRAIN INLET (DI) / YARD DRAIN (YD) STORMWATER PRECAST MANHOLE
1 5 6
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
VINYL COATED CHAIN LINK
LOCKING MECHANISM PROVIDED FOR GATES WITH PRIVACY SLATS
OPEN & CLOSED POSITIONS (TYP) & EXPANSION JOINTS
VINYL COATED CHAIN LINK NOTE:
6'-0" MINIMUM
GATES WITH PRIVACY SLATS PROVIDE FENCE AND GATE SHOP
& EXPANSION JOINTS DRAWINGS TO ENGINEER FOR TOWN NOTES:
±9"
CURB LINE APPROVAL PRIOR TO FABRICATION. 1. WHEN PIPES ARE TO BE INSTALLED IN FILL SECTIONS, THE CONTRACTOR SHALL INSTALL CRUSHED STONE, GRAVEL OR APPROVED
STRUCTURAL FILL.
INSTALL PER MANUFACTURER 2. BACKFILL TO 95% RELATIVE MATERIAL COMPACTED DRY DENSITY AT OPTIMUM MOISTURE UNDER PAVED AREAS AND 90% UNDER
SPECIFICATIONS LANDSCAPED AREAS (TYP.)
3. BACKFILL WITH 90PSI FLOWABLE CONCRETE IN TOWN R.O.W. (K-CRETE)
4. K-CRETE BACKFILL SHALL BE USED IN ALL TRENCHING (SANITARY SEWER AND WATER MAIN) LOCATED WITHIN THE EXISTING
CLEAR PAVEMENT. PRIOR TO THE PLACEMENT OF THE K-CRETE BACKFILL, THE PIPE SHALL BE SURROUNDED WITH A MINIMUM OF 12-INCHES
OF NYSDOT ITEM 304.05 OR CLEAN SAND AS DIRECTED BY THE UTILITY OWNER. THE REMAINDER OF THE TRENCH (UP TO THE BOTTOM
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
OF PAVEMENT SECTION) SHALL THEN CONSIST OF K-CRETE.
DEPTH (SEE PLAN)
STRUCTURAL CONCRETE PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
STRUCTURAL CONCRETE MAT SLAB 5. REFER ALSO TO DETAIL 5, DWG. SP-4.1 (SAW-CUT PAVEMENT KEY-IN) FOR TRENCHING WITHIN EXISTING PAVEMENT. 1-800-962-7962 OR 811
6'H CHAIN LINK MAT SLAB
CLEAR
6. CONTRACTOR SHALL SURROUND THE NEW PIPE WITH 6-INCHES OF NYSDOT ITEM 304.14 ALL AROUND THE OUTSIDE OF THE PIPE.
FENCE WITH 7. WHEN DETERMINED BY ENGINEER OR DOTS, AND AS DIRECTED, REMOVE UNSUITABLE MATERIAL AND BACKFILL WITH NYSDOT ITEM
PRIVACY SLATS FRONT ELEVATION 304.14 OR ¾" WASHED GRAVEL AND CRUSHED STONE, COMPACT IN 6- INCH LIFTS.
6" DIA CONCRETE 8. FOR CL-54 CEMENTED LINED DIP WATER MAIN AND CI-52 CEMENT LINED DIP SEWER MAIN, TRENCH SHALL BE 30-INCHES PLUS THE O.D.
FILLED STEEL BOLLARDS OF PIPE, AND PIPE SHALL BE IN CENTER OF THE TRENCH.
REINFORCED CONCRETE 6'H CHAIN LINK FENCE
WITH PRIVACY SLATS 9. REMOVE ALL BEDROCK WITHIN 6-INCHES OF PIPE.
LOADING AREA PAD
BOLLARD 10. THE CONTRACTOR SHALL FOLLOW ALL GUIDELINES ESTABLISHED BY OSHA (TITLE 29 PART 1926.650-652 (SUBPART-P) FOR TRENCHING
(TYP.) OPERATIONS. TRENCHES GREATER THAN 5-FEET IN DEPTH REQUIRE A PROTECTIVE SYSTEM, PRIOR TO ANY WORK, CONTRACTOR
4000 PSI CONCRETE PAD SHALL SUBMIT TO DOTS FOR REVIEW A TRENCHING PLAN.
11. RECYCLED FILL/ITEM 4 IS NOT PERMITTED AS BACKFILL.
FOR FINISHED GRADE 12. CONTRACTOR SHALL SURROUND THE NEW PIPE WITH 6-INCHES OF NYSDOT ITEM 304.14 ALL AROUND THE OUTSIDE OF THE PIPE.
LENGTH (SEE PLAN) 13. WHEN DETERMINED BY ENGINEER OR DOTS, AND AS DIRECTED, REMOVE UNSUITABLE MATERIAL AND BACKFILL WITH NYSDOT ITEM
SEE DRAWINGS NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
304.14 OR ¾” WASHED GRAVEL AND CRUSHED STONE, COMPACT IN 6-INCHLIFTS. BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
14. FOR CL-54 CEMENTED LINED DIP WATER MAIN AND CI-52 CEMENT LINED DIP SEWER MAIN, TRENCH SHALL BE 30-INCHES PLUS THE O.D. DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
PLAN VIEW OF PIPE, AND PIPE SHALL BE IN CENTER OF THE TRENCH. ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
15. REMOVE ALL BEDROCK WITHIN 6-INCHES OF PIPE. THE CONTRACTOR SHALL FOLLOW ALL GUIDELINES ESTABLISHED BY OSHA (TITLE WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
29 PART 1926.650-652 (SUBPART-P) FOR TRENCHING OPERATIONS. TRENCHES GREATER THAN 5-FEET IN DEPTH REQUIRE A
NOTES: PROTECTIVE SYSTEM, PRIOR TO ANY WORK, CONTRACTOR SHALL SUBMIT TO DOTS FOR REVIEW A TRENCHING PLAN. WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
8"
1. ALL POSTS, RAILS, AND ACCESSORIES SHALL BE POWDER COATED; COLOR TO MATCH MESH COLOR. 16. RECYCLED FILL/ITEM 4 IS NOT PERMITTED AS BACKFILL. DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
8"
2. TERMINAL POSTS SHALL CONSIST OF END, CORNER, ANGLE AND PULL POSTS. ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
6" X 6"
12"
3. FABRIC SHALL BE INSTALLED ON THE OUTSIDE. AGGREGATE SUBBASE SHOWN BY THESE DRAWINGS.
4. REFUSE AREA ENCLOSURE: FOR ALL FENCES AND GATES, PROVIDE PVC 'LOCK TOP' PRIVACY SLATS W4.0 X W4.0 WWF
(WITHOUT WINGS) IN REDWOOD COLOR AS PROVIDED BY HOOVER FENCE CO. 1-800-355-2335 OR APPROVED COMPACTED LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
12" SUBGRADE YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
APPROVED EQUAL DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
5. SUBMIT SHOP DRAWINGS TO PROJECT ENGINEER FOR APPROVAL PRIOR TO FABRICATION. PROFILE VIEW 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
REFUSE ENCLOSURESCALE: TRENCH DETAIL (STORM / SEWER / WATER) NOT FOR CONSTRUCTION
7 8
N.T.S. SCALE: N.T.S.
1 01/21/2026 SITE PLAN APPLICATION
2 02/18/2026 ISSUE TO PLANNING BOARD
3 03/25/2026 ISSUE TO PLANNING BOARD
PARCEL 3 -
SITE DETAILS
SP-6.2
Page 97
PIPE REMOVED
FROM SERVICE WATER LINE
WATER MAIN NOTES:
1. ALL PIPE SUPPLIED IS UNITED PIPE AND FOUNDRY “TYTON JOINT” WITH PUSH ON RUBBER GASKETS
ENCASE IN
BLOCK DIMENSIONS THRUST BLOCK
WITH TWO (2) BRONZE WEDGES PER JOINT, DOUBLE CEMENT LINED CLASS 54 DUCTILE IRON PIPE
C 3,500 PSI CONC. PIPE WITH A PRESSURE RATING OF 350 PSI;
CONC. CONC. 3,500 PSI CONC.
18" MIN.
2' MIN. D.I.P. BEND
DIA. BEND A (FT.) B (FT.) C (FT.)
(CF) (CY)
2. ALL FITTINGS SHALL BE FULL BODY, MECHANICAL JOINT WITH RETAINER GLANDS, DOUBLE CEMENT
(IN.) NO CONC. SHALL BE BLOCK DIMENSIONS SEWER OR LINED, DUCTILE IRON PIPE AS MANUFACTURED BY UNITED STATES PIPE AND FOUNDRY COMPANY,
BRANCH DRAIN LINE
90 10.9 6.0 2.0 130.8 4.9 POURED AGAINST JOINTS CONC. CONC. MADE IN THE U.S.A. OR APPROVED EQUAL.
SIZE A (FT.) B (FT.) C (FT.)
3. THE PIPE AND FITTINGS SHALL BE CEMENT MORTAR LINED TO TWICE THE STANDARD THICKNESS IN
'B'
45 7.9 4.5 2.0 71.1 2.7 (CF) (CY)
EVERGREEN MANOR
UNDISTURBED (IN.)
'B'/2
16
22 21 6.0 3.0 2.0 36.0 1.3 TRENCH WALL
6 2.0 2.0 14.8 0.5 10' MIN. 10' MIN. ACCORDANCE WITH ANSI A21.4 (AWWA C104) EXCEPT AS NOTED.
3.7
C
11 41 3.6 2.5 2.0 18.0 0.7 DEFLECTION OF PIPE AS PER 4. ALL CHANGES IN PIPE DIRECTIONS, REQUIRING FITTINGS BOTH VERTICAL AND HORIZONTAL, SHALL
SECTION VIEW 8 5.0 2.5 2.0 25.0 0.9 MANUFACTURER'S RECOMMENDATIONS BE SECURED WITH RETAINER GLANDS AND THRUST BLOCKED WITH CONCRETE AGAINST
90
45
9.4
5.8
4.0
3.5
2.0
2.0
75.2
40.6
2.8
1.5 10 6.3 3.0 2.0 37.8 1.4
OR AS REQUIRED BY
THE WATER DEPARTMENT UNDISTURBED EARTH. Town of Cortlandt, New York
12 5. ALL BENDS, TEES AND SOLID SLEEVES SHALL BE MECHANICAL JOINT WITH RETAINER GLANDS,
22 21 4.2 2.5 2.0 21.0 0.8 12 6.7 4.0 2.0 61.6 2.3 PRESSURE CLASS 350, DUCTILE IRON AS MANUFACTURED BY UNITED STATES PIPE AND FOUNDRY
11 41 2.6 2.0 2.0 10.4 0.4
16 10.3 4.5 2.0 92.7 3.4 20' MIN. COMPANY OR APPROVED EQUAL. SOLID SLEEVES SHALL BE A MINIMUM 12” IN LENGTH.
90 6.7 4.0 2.0 53.6 2.0
6. ALL FITTINGS SHALL CONFORM TO THE FOLLOWING OR LATEST SPECIFICATIONS:
45 5.8 2.5 2.0 29.0 1.1 DUCTILE IRON FITTINGS: ANSI/AWWA C110/A21.10
10
22 21 3.7 2.0 2.0 14.8 0.5 ANSI/AWWA/C104/A21.04
8" MIN. PLAN VIEW
11 41 2.5 1.5 2.0 7.5 0.3
90 5.1 3.5 2.0 35.7 1.3 FITTING JOINTS: ANSI/AWWA C111/A21.11
18" MIN.
45 3.8 2.5 2.0 19.0 0.7 SANITARY SEWER OR
2' MIN.
8 WATER LINE 7. GATE VALVES SHALL BE MUELLER IRON BODY, NON-RISING STEM CONVENTIONAL PACKING,
22 21 3.3 1.5 2.0 9.9 0.4 A STORM DRAIN
C
11 41 5.0 0.2
(PRESSURE PIPE) RESILIENT SEATED, MECHANICAL JOINT WITH RETAINER GLANDS, PRESSURE CLASS 350, OPENING
2.5 1.0 2.0 THRUST BLOCK AT CAP
10' MIN. 10' MIN. LEFT (CCW) AND OPERATION SHALL BE BY 2” SQUARE WRENCH NUT. ALL GATE VALVES SHALL
90 4.1 2.5 2.0 20.5 0.8
'A' 2.8 2.0 2.0 11.2 0.4
CONFORM TO THE LATEST SPECIFICATIONS OF ANSI/AWWA C509. OWNER / APPLICANT
8. ALL VALVE BOXES SHALL BE MADE IN THE USA AND SHALL CONFORM TO THE LATEST
B
45
6 NOTE:
PLAN VIEW 22 21 2.8 1.0 2.0 5.6 0.2 BLOCK DIMENSIONS 1. FOR ANY CONDITIONS OTHER THAN SHOWN AT RIGHT, THE FOLLOWING REQUIREMENTS SHALL BE MET. THE JOINTS OF THE SANITARY SEWER OR SPECIFICATIONS OF ASTM A-48. VALVE BOXES SHALL BE MANUFACTURED BY TYLER UNION, MODEL V.S. CONSTRUCTION CORPORATION
11 41 1.4 1.0 2.0 2.8 0.1 PIPE
CONC. CONC.
STORM DRAIN SHALL BE A MINIMUM OF 10' FROM THE POINT OF CROSSING. THE SANITARY SEWER SHALL BE CLASS 150 PRESSURE PIPE AND THE 6855 SLIP TYPE, CAST IRON – 2 PIECES WITH AN EXTENSION HEIGHT BETWEEN 39”-60”. LIDS SHALL 37 CROTON DAM ROAD
DIA. BEND A (FT.) B (FT.) C (FT.) STORM DRAIN SHALL BE LOCK JOINT PRESSURE PIPE. WHERE THE ABOVE CONDITIONS CANNOT BE MET, THE WESTCHESTER COUNTY DEPARTMENT BE MARKED “WATER”.
SECTION VIEW (IN.)
(CF) (CY)
OF HEALTH WILL BE NOTIFIED AND THEIR APPROVAL WILL BE REQUIRED. OSSINING, NY 10562
2. WHERE THE WATER LINE PASSES BENEATH THE SEWER LINE OR STORM DRAIN, THE JOINTS OF THE PIPE SHALL BE A MINIMUM OF 10' FROM THE 9. RETAINER GLANDS ARE “MEGALUG” SERIES 1100 MECHANICAL JOINT RESTRAINT FOR DUCTILE IRON
(BACK OF THRUST BLOCK) 90 12.0 8.3 6.3 313.7 11.5
POINT OF CROSSING. SEWER PIPE SHALL BE CLASS 150 PRESSURE PIPE AND THE STORM DRAIN SHALL BE LOCK-JOINT PRESSURE PIPE. PIPE AS MANUFACTURED BY EBAA IRON, INC. THEY SHALL BE CONSTRUCTED OF ASTM A536
45 12.0 7.5 5.0 225.0 8.3 3. REQUIREMENTS AS STATED IN TWO CONDITIONS ABOVE WILL ALSO APPLY WHEN HORIZONTAL SEPARATION BETWEEN THE SEWER AND WATER IS DUCTILE IRON AND APPROVED FOR USE ON POTABLE WATER PIPE LINES SUBJECT TO HYDROSTATIC
16
22 21 11.5 7.0 3.0 120.8 4.5 LESS THAN 10' AND VERTICAL SEPARATION IS LESS THAN 18". WHERE THE ABOVE CONDITIONS CANNOT BE MET, THE WESTCHESTER COUNTY
DEPARTMENT OF HEALTH WILL BE NOTIFIED AND THEIR APPROVAL WILL BE REQUIRED IF NOT PREVIOUSLY APPROVED.
PRESSURE AND TESTED IN ACCORDANCE WITH EITHER AWWA C600 OR ASTM D2774. PLANNER, CIVIL ENGINEER, LANDSCAPE
THRUST BLOCK AT HORIZONTAL BEND 11 41 9.0 4.5 3.0 60.8 2.3 10. THRUST BLOCKS SHALL HAVE A COMPRESSIVE STRENGTH OF FC = 3,500 PSI (MINIMUM) AT 28 DAYS ARCHITECT
90 10.0 6.5 5.5 178.8 6.6 AND SHALL BE FORMED AND POURED AGAINST UNDISTURBED EARTH.
11. AFTER THE TRENCH HAS BEEN BACKFILLED, HYDROSTATIC ACCEPTANCE TESTS, CONSISTING OF A
12
45
22 21
9.5
9.0
6.5
5.0
4.3
3.0
132.8
67.5
4.9
2.5 PRESSURE TEST AND A LEAKAGE TEST, SHALL BE PERFORMED ON ALL SECTIONS OF WATER MAINS DTS PROVIDENT
TITLE TITLE CROSSING OF WATER LINE AND STORM / SANITARY SEWER INSTALLED. LEAKAGE TEST 2000 FT (MAX.). Intelligent Land Use
11 41 8.0 4.5 3.0 54.0 2.0 2
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. 12. AFTER ALL TESTS AND INSPECTIONS HAVE BEEN PERFORMED EVIDENCE OF COMPLIANCE SHALL BE
90 11.0 6.25 3.75 128.9 4.8 DTS Provident Design Engineering, LLP CA #: 0017846
EYEBOLTS SET
45 10.0 5.0 3.75 93.8 3.5
FORWARDED TO THE OWNER/ENGINEER AND THE MUNICIPALITY PRIOR TO ACCEPTANCE. One North Broadway
BLOCK DIMENSIONS
BRANCH
IN CONCRETE 10 13. ALL WATER FOR TESTS SHALL BE FURNISHED AND DISPOSED OF BY THE CONTRACTOR AT THE White Plains, NY 10601
CONC. CONC. 22 21 8.0 4.5 3.0 54.0 2.0
POUR THRUST BLOCK SIZE A (FT.) B (FT.) C (FT.) ANCHOR RODS
HYDRANT SHALL BE
CONTRACTOR'S EXPENSE. SOURCE AND/OR QUALITY OF WATER WHICH THE CONTRACTOR
(CF) (CY) EDGE OF TRENCH (SEE SCHEDULE BELOW) 11 41 8.0 4.5 3.0 54.0 2.0 P: 914.428.0010
AGAINST UNDISTURBED SOIL (IN.)
NOTE: "MUELLER" SUPER CENTURION 350 PROPOSES TO USE IN TESTING LINES SHALL BE ACCEPTABLE TO THE DEPARTMENT OF TECHNICAL F: 914.428.0017
90 9.5 4.5 4.0 85.5 3.2 MODEL #A423HP, WITH SAFETY SERVICES.
6 3.7 2.0 2.0 14.8 0.5 1. PUMPER OUTLET SHALL FACE STREET; 2'-6" MAX.
'A'
45 9.5 4.0 3.3 62.7 2.3 HOSE OUTLETS SHALL BE PARALLEL TO BREAKAWAY FLANGE, 3-WAY, OPENING 1'-6" MIN. 14. HYDROSTATIC PRESUMPTIVE TESTS MAY BE PERFORMED WHEN SYSTEM IS PARTIALLY BACKFILLED
EDGE OF
18" MIN. 8 5.0 2.5 2.0 25.0 0.9 8
22 21 8.0 4.5 3.0 54.0 2.0 STREET. LEFT (CCW). THE PUMPER NOZZLE/MAIN
TO SIMPLY CHECK WORK, BUT ACCEPTANCE OF SYSTEM SHALL BE BASED ON HYDROSTATIC TESTS ARCHITECT - PARCEL 3
2. PLUMBNESS OF HYDRANT TO BE VALVE SHALL BE 5 41" , THE TWO HOSE
TRENCH 10 6.3 3.0 2.0 37.8 1.4 11 41 8.0 4.5 3.0 54.0 2.0 RUN ON FINISHED SYSTEM AFTER IT HAS BEEN COMPLETELY BACKFILLED. BEATTY HARVEY COCO ARCHITECTS
2' MIN.
CHECKED IN TWO DIRECTIONS, 90^ NOZZLES SHALL BE 2 21".
APART. 15. FOR THE PRESSURE TEST, THE SYSTEM SHALL BE PRESSURIZED AND MAINTAINED AT 1.5 TIMES THE 1300 WALT WHITMAN ROAD
C
4.5 54.0
B
12 6.7 4.0 2.0 61.6 2.3 90 8.0 3.3 2.0
3. RODDING SHALL CONSIST OF TWO 43" WORKING PRESSURE TO A MINIMUM OF 225 POUNDS PER SQUARE INCH AND CORRECTED TO THE
16 10.3 4.5 2.0 92.7 3.4 A 45 8.0 4.5 3.3 54.0 2.0
THREADED RODS CAREFULLY COATED ELEVATION OF THE GAUGE. PROVISIONS SHALL BE MADE TO RELIEVE AIR TRAPPED AT HIGH POINTS
MELVILLE, NY 11747
6 EDGE OF
22 21 8.0 4.5 3.0 54.0 2.0 WITH BITUMASTIC PAINT. RODDING PAVEMENT OR CURB IN THE SYSTEM THROUGH ADJACENT HYDRANTS OR THROUGH TAPS AND CORPORATION STOPS
FINISHED GRADE
MAY BE OMITTED BETWEEN THE MAIN
MIN. 2 CY OF
11 41 8.0 4.5 3.0 54.0 2.0
AND LATERAL VALVE ONLY WHERE A WHEN DIRECTED
INSTALLED FOR THIS PURPOSE BY THE CONTRACTOR. AFTER SAID PRESSURE HAS BEEN MAINTAINED LAND USE ATTORNEY
CONC. THRUST TAPPING VALVE OR HYDRANT VALVE DRAIN HOLES SUCCESSFULLY FOR A PERIOD OF AT LEAST TWO HOURS, AND NO LEAKAGE HAS BEEN OBSERVED,
BLOCK GRAVITY BLOCKS ANCHORING TEE IS USED. TO BE PLUGGED THE SECTION UNDER TEST SHALL BE CONSIDERED TO HAVE PASSED THE PRESSURE TEST. ZARIN & STEINMETZ
3,500 PSI CONC. NOTES: VERTICAL UP
SPLIT COLLAR W/ 34"
4. 1 12" STONE SHALL BE PLACED AROUND IN AREAS OF 16. IF LEAKAGE IN SYSTEM IS OBSERVED, THE CONTRACTOR SHALL, AT NO ADDED COST TO THE OWNER, 81 MAIN STREET
1. ALL THRUST BLOCKS SIZED IN ACCORDANCE WITH AWWA GRAVITY BLOCKS SHALL REQUIRE A MINIMUM OF 2 CY HIGH GROUND WATER. 6" VALVE AND
THE HYDRANT FROM THE BOTTOM OF LOCATE, REPAIR, AND/OR REPLACE DEFECT(S) AND RE-TEST PIPING SYSTEM. WHITE PLAINS, NY 10601
PLAN VIEW DUCTILE IRON PIPE AND FITTINGS, AWWA MANUAL M41 THREADED RODS W/ CONCRETE PER INSTALLATION. (SEE NOTE 5) VALVE BOX TO BE
D.I.P. TEE THE TRENCH, BUT AT LEAST 6" BELOW
SECOND EDITION - DUCTILE IRON PIPE RESEARCH ANCHOR RODS
WASHERS AND NUTS
THE BASE OF THE HYDRANT TO 6" MUELLER CAT. NO. 2380 17. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAINS AND SEWER PIPE SHALL BE 18 INCHES
AS ANCHOR BOLTS IMBEDDED REFER TO "GRAVITY BLOCK RESTRAINT INSTALLATION DETAIL". 2 LAYERS OF TARPAPER
THRUST RESTRAINT DESIGN FOR DUCTILE IRON PIPE. (SEE SCHEDULE BELOW) IN THE THRUST BLOCK (AS
ABOVE THE WASTE OPENING AND TO A OR APPROVED EQUAL MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD SURVEYOR
OVER 1 21" STONE
2. CALCULATIONS APPLY A 1.5 SAFETY FACTOR.
PART OF THRUST BLOCK REFER TO "THRUST BLOCK NOTES" FOR INSTALLATION
DISTANCE OF 12" AROUND THE ELBOW. RODDING BETWEEN LAYING LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH
3. CALCULATIONS BASED UPON MINIMUM PRESSURE CLASS 5. HYDRANTS WITH PLUGGED DRAINS
OF PIPE WITH STANDARD CEMENT-MORTAR LINING. ITEM) REQUIREMENTS WHERE APPLICABLE. SHALL HAVE A 3" BLACK CIRCLE PAINTED
STONE, CONCRETE TEE AND VALVE JOINTS WILL BE AS FAR FROM THE SEWER LINE AS POSSIBLE. IN ADDITION, WHEN THE WATER MAIN DANIEL T. MERRITTS, PLS
AND BETWEEN PASSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECT FILL) SHALL BE
4. CALCULATIONS BASED UPON A SOIL BEARING PRESSURE EYEBOLTS SET ANCHOR SCHEDULE FOR GRAVITY BLOCKS
DIRECTLY UNDER THE PUMPER OUTLET. OR CONCRETE BLOCK,
MINIMUM 6" THICK VALVE AND HYDRANT
394 BEDFORD ROAD
OF 1,000 LBS. PER SQUARE FOOT. IN CONCRETE 6. HYDRANT DRAINS TO BE PLUGGED
AND 12" SQUARE
PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE PLEASANTVILLE, NY 10570
C 5. CALCULATIONS BASED UPON A 130 PSI TEST PRESSURE,
PIPE DIAMETER RODS MIN. EMBEDMENT LENGTH
WHERE THE WATER TABLE IS WITHIN 7' (SEE NOTE 3) SEWER PIPE ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL
MIN. 2 CY OF
B
2' MIN. MAXIMUM OF FINISHED GRADE. WHEN THE DRAINS THRUST BLOCK
CONC. THRUST 3 - #4 4,000 PSI CONCRETE WATER MAINS AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET
6. DIMENSIONS ESTABLISHED BASED UPON TRUNCATED
TRIANGULAR SHAPED THRUST BLOCK GEOMETRY BLOCK
16"
12" 3 - #4
24"
18"
ARE PLUGGED, THE BARRELS MUST BE
PUMPED DRY AFTER USE DURING
OR STONE ANCHORAGE
MEASURED FROM THE OUTSIDE OF THE PIPES, MANHOLES OR VAULTS. WETLAND CONSULTANT
6" 2 - #5 12" AGAINST
7. ALL CONCRETE SHALL BE A MINIMUM 3,500 PSI OR A EDGE OF TRENCH FREEZING WEATHER. WHERE HYDRANT UNDISTURBED EARTH 18. ALL WATER MAINS SHALL HAVE A MINIMUM OF FOUR FEET OF COVER FROM THE TOP OF THE MAIN TIM MILLER ASSOCIATES, INC.
'B'
8" 2 - #5 12"
GREATER AT 28 DAYS DRAINS ARE NOT PLUGGED, A GRAVEL TO FINISHED GRADE. THE CONTRACTOR SHALL CHECK ALL FINISHED GRADE STAKES BEFORE
'B'/2
8. ALL THRUST BLOCKS SHALL BE POURED AGAINST NOTE: POCKET OR DRY WELL SHALL BE LIMITS OF
TRENCHING TO ENSURE THAT ALL INSTALLED WATERMAINS WILL HAVE THE REQUIRED COVER.
10 NORTH STREET
UNDISTURBED SOILS 1. ALL EMBEDDED RODS SHOULD HAVE STANDARD ACI PROVIDED UNLESS THE NATURAL SOILS 1 21 " STONE COLD SPRING, NY 10516
9. NO CONCRETE SHALL BE POURED AGAINST PIPE JOINTS HOOKS. WILL PROVIDE ADEQUATE DRAINAGE. FOR DRAINAGE.
6" 19. THE SUPPLIER OF WATER MUST RECEIVE AT LEAST 48-HOUR ADVANCE NOTIFICATION REQUESTING
SECTION VIEW 10. THRUST BLOCK SHOWN ARE MINIMUM SIZES 2. IN SOME CASES, IT WILL BE NECESSARY TO INCREASE HYDRANT DRAINS SHALL NOT BE (SEE NOTE 4) SAMPLING SERVICES. SAMPLING WILL NOT BE PERFORMED PRIOR TO RECEIPT FROM A NEW YORK
11. THRUST BLOCK FOR 90 DEGREE BENDS SHALL ONLY BE THE MINIMUM DIMENSIONS SHOWN TO ATTAIN THE CONNECTED TO OR LOCATED WITHIN 10' STATE LICENSED OR REGISTERED DESIGN PROFESSIONAL (ENGINEER, ARCHITECT, OR LAND
PERMITTED ON FJ TO FJ CONNECTIONS. MINIMUM CONCRETE VOLUMES. OF SANITARY SEWERS OR STORM
NOTE: 12. ALL WORK TO CONFORM TO WESTCHESTER JOINT WATER VERTICAL DOWN DRAINS. SURVEYOR WITH A SPECIAL EXEMPTION UNDER SECTION 7208(N) OF THE EDUCATION LAW)
THRUST BLOCK AT TEE
NO CONC. SHALL WORKS AND TOWN OF HARRISON STANDARDS AND THRUST BLOCK AT HORIZONTAL BEND 6" LATERAL CERTIFYING THAT THE WATER SUPPLY IMPROVEMENTS, TESTING AND DISINFECTION PROCEDURES
BE POURED SPECIFICATIONS. WERE COMPLETED IN ACCORDANCE WITH THE APPROVAL PLANS, REPORTS, SPECIFICATIONS AND
AGAINST JOINTS
ANY APPROVED AMENDMENTS. A NYSDOH CERTIFIED LABORATORY WILL COLLECT SAMPLES FOR
FREE CHLORINE RESIDUAL, TOTAL AND FECAL COLIFORM AND 24-HOUR BACTERIAL PLATE COUNT.
THE CERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE WATER MAINTENANCE SUPERVISOR
AS A CONDITION OF APPROVAL FOR OPERATION.
20. THE CONTRACTOR SHALL COORDINATE THE TESTING WITH THE WATER DEPARTMENT SO AS TO
THRUST BLOCK HYDRANT SETTING MAINTAIN THE AMOUNT OF SERVICE INTERRUPTION TO EXISTING USERS TO THE LEAST EXTENT
SCALE: N.T.S. 1 3 PRACTICABLE. WATER MAIN INSTALLATION AND TESTING SHALL BE PERFORMED UNDER THE
SCALE: N.T.S.
SUPERVISION OF THE PROJECT ENGINEER OR HIS DESIGNEE.
21. THE WATER MAIN SHALL BE DISINFECTED EQUAL TO AWWA STANDARD FOR DISINFECTING WATER
TOP OF CASTING FINISH HEAVY DUTY CASTINGS AND COVERS MAINS DESIGNATION C651 (LATEST REVISION). FOLLOWING DISINFECTION, THE WATER MAIN
GRADE; SEE PLANS FOR MANUFACTURED BY CAMPBELL FOUNDRY CO. SHALL BE FLUSHED UNTIL THE CHLORINE CONCENTRATION IN THE WATER LEAVING THE MAIN IS NO
ELEVATION PATTERN NO. 1041B WITH LETTERING "SEWER" OR
APPROVED EQUAL
HIGHER THAN THAT GENERALLY PREVAILING IN THE SYSTEM. THE PROJECT ENGINEER OR HIS
2 COURSES OF BRICK UNDISTURBED DESIGNEE, AND TOWN OF CORTLANDT SHALL ALSO WITNESS DISINFECTION AND FLUSHING.
2-11" 12" SIDES OF 12"
3" CLEAR FROM UNDERSIDE
LABEL CL TRENCH
12" 22. THE SAMPLING POINT(S) MUST BE DECONTAMINATED BY FLAMING.
OF COVER TO TOP OF CAP. 23. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS.
8" 3' - 0" 24. THE WATER LINE SHALL BE INSTALLED AT A CONTINUOUS GRADE WITH NO ABRUPT HIGH POINTS
8"
12"
AREA OF CIRCUMFERENTIAL FINISHED GRADE
CLEAN-OUT FRAME AND COVERS SHALL BE PIPE OR LOW POINTS.
STEEL 12" SQ. IN / LIN. FT. PATTERN NO. 4153 OR AN APPROVED EQUAL 25. FINAL WATER DISTRIBUTION SYSTEM IS SUBJECT TO REVIEW, REVISION AND APPROVAL BY THE
6"
(PAVEMENT AREAS) AS MANUFACTURED BY CAMPBELL FOUNDRY COMPANY.
PLASTIC COATED STEEL (See notes Below). PIPE DEPARTMENT OF TECHNICAL SERVICES.
1'
STEPS CONFORMING TO 26. THE WATER MAIN SHALL NOT BE PLACED INTO SERVICE UNTIL SO AUTHORIZED BY THE TOWN OF
FINISHED GRADE
NYSDOT SECTION 725-02
(NON-PAVEMENT AREAS) THREADED CAP CORTLANDT.
27. ALL WATER SERVICE CONSTRUCTION SHALL BE SUBJECT TO INSPECTION BY THE DEPARTMENT OF
12"
SELF SEALING
BUTYL RUBBER GASKET TECHNICAL SERVICES PRIOR TO BACKFILLING. BEDDING, PIPE ZONE, AND TRENCH BACKFILL
TYP. (TWO PROJECTIONS) THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
MATERIAL SHALL BE COMPOSED OF CRUSHED STONE OR LIGHT GRAVEL HAVING A GRADATION PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
ASTM C44360T CONCRETE ANCHOR 1-800-962-7962 OR 811
PRECAST CONCRETE RISER DETAIL "A" LIMIT OF 3/4" MINUS. AN ACCEPTABLE MATERIAL SHALL MEET THE FOLLOWING REQUIREMENTS:
SECTION AS NEEDED MIN. 3,000 PSI.
(HEIGHT VARIES) 4"-6" MIN. 3/4" WASHED
SEE DTL. "A" GRAVEL OR CRUSHED STONE Sieve designation % passing
USE FLEXIBLE BASE UNDER CLEAN-OUT PVC OR DIP ¾” 100%
RUBBER BOOT, TYP. NOTE: FRAME AND COVER. No. 40 0-70%
(ALL PIPE 4'-0" DIA. MIN. NOTES:
1. ALL STRUCTURES AND CASTINGS TO SUPPORT H20 LOADING No. 200 0-10%
CONNECTIONS, (5'-0" DIA ≥ 10' DEEP) 2. CONTRACTOR TO SUBMIT FABRICATION SHOP DRAWINGS 1. PIPE ANCHORS SHALL BE INSTALLED AS FOLLOWS:
IN AND OUT) 5" FOR APPROVAL. GRADE 20% TO 35% - 36ft C TO C MAX.
3. CONCRETE SHALL BE A MINIMUM OF 4,500 PSI. 28. THE SITE UTILITY CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BURIED PIPING TO THE LOCATION
PIPE
4. APPLY 2-2 MILS OF BITUMINOUS MATERIAL "INERTOL No.
PVC OR DIP
GRADE 35% TO 50% - 24FT C TO C MAX. OF THE PROPOSED BUILDING CONNECTION POINT (I.E. INSIDE THE BUILDING). THIS INCLUDES THE
SLOPE 1" PER 1' 49 KOPPERS SUPER SERVICE", BLACK OR APPROVED 45° BEND GRADE OVER 50% - 16FT C TO C MAX. TESTING AND CERTIFICATION OF ALL WATER SERVICE WORK FROM THE TOWN WATER
18" TO 48"
EQUAL. APPLY IN ACCORDANCE WITH MANUFACTURER'S NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
SPECIFICATIONS. 2. ALL PIPES WITH A GRADE OF 20% OR GREATER SHALL HAVE AT LEAST ONE (1) PIPE ANCHOR CONNECTION POINT TO THE PROPOSED BUILDING’S INTERIOR CONNECTION POINT. BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
7" DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
29. INDICATOR TAPE SHALL BE PLACED AT 12 INCHES BELOW FINISHED GRADE DIRECTLY ABOVE ALL
3"
INSTALLED ON THE JOINT NEAREST THE MIDDLE OF A VERY SHORT LINE. ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
INVERT SHELF CAST IN 12" COMPACTED CRUSHED STONE CAPPED END WATERLINES. SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
PLACE 2" ABOVE TOP OF PVC OR DIP SEE PLAN 3. IF A PIPE ANCHOR IS SET AT THE BELL END OF A PIPE, THE CONCRETE SHALL BE PLACED IN WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
PIPE, TYP.
BEDDING COURSE
WYE BRANCH FOR INVERT
30. ALL COPPER WATER SERVICE PIPING INSTALLATION, BACKFILL AND TESTING SHALL BE REVIEWED,
UNDISTURBED SUBGRADE SUCH A MANNER AS TO ASSURE EXPOSURE OF THE JOINT. AND APPROVED BY THE DEPARTMENT OF TECHNICAL SERVICES. BEDDING, PIPE ZONE, AND WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
BACKFILL MATERIAL MUST BE SAND ONLY.
8"
3 MATERIAL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
8" STL. REINF. RODS;
8" O.C. BOTH WAYS PVC OR DIP 31. PRIOR TO THE BACKFILLING OF ANY WATER LINES AND COMPONENTS, DOTS-ENGINEERING SHALL ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
FLOW PVC OR DIP SHOWN BY THESE DRAWINGS.
SEWER SERVICE LINE BE NOTIFIED TO PERFORM AN INSPECTION.
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
PRECAST CONCRETE YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
1'-0" DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
BASE RISER SECTION 7'-0" DIA. 7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
SANITARY SEWER MANHOLE CLEANOUT PIPE ANCHORS NOT FOR CONSTRUCTION
4 5 6
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
1 01/21/2026 SITE PLAN APPLICATION
2 02/18/2026 ISSUE TO PLANNING BOARD
EXISTING OR PROPOSED
FINISHED GRADE WESTCHESTER COUNTY PUBLIC WATER SUPPLY AND 3 03/25/2026 ISSUE TO PLANNING BOARD
5 41 " SHAFT
SANITARY SEWER GENERAL CONSTRUCTION NOTES
WATER NOTES:
1. ALL WATER MAINS TO BE CEMENT LINED CL-54 DUCTILE IRON PIPE. DOMESTIC MATERIAL
ONLY, NO IMPORTS.
2. PRESSURE/LEAKAGE TESTING SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
ADJUSTABLE CAST IRON VALVE BOX SHALL CONFORM TO EDITION OF AWWA STANDARD 600. NO LEAKAGE PERMITTED.
THE LATEST SPECIFICATIONS OF ASTM A-48. VALVE BOXES 3. DISINFECTION AND BACTERIOLOGICAL TEST WILL BE PERFORMED IN ACCORDANCE WITH
SHALL BE MANUFACTURED BY: TYLER UNION, MODEL 6855 AWW STANDARD C651-92, EXCEPT FOR SECTION 5.1.
SLIP TYPE, CAST IRON - 2 PIECES WITH AN EXTENSION 4. THE SUPPLIER'S RECORDS INDICATE ADEQUATE PRESSURE AND CAPACITY IS AVAILABLE
HEIGHT BETWEEN 39”-60”. LIDS SHALL BE MARKED “WATER”. FOR THE AREA.
5. THE MINIMUM WATER MAIN INSTALLATION DEPTH WILL BE AT LEAST FOUR (4) FEET
BELOW THE FINISHED GROUND SURFACE (MEASURED FROM TOP OF PIPE). THE MINIMUM
REQUIRED SEPARATION BETWEEN WATER MAIN AND SANITARY SEWER/STORM DRAIN
48" MIN.
PIPING SHALL BE EIGHTEEN (18") INCH VERTICAL, TEN (10') FOOT HORIZONTAL. THE
MINIMUM REQUIRED TEN (10') FOOT HORIZONTAL SEPARATION IS ALSO APPLICABLE NOTE:
BETWEEN WATER MAINS AND SANITARY SEWER MANHOLES, STORM DRAIN MANHOLES
AND CATCH BASINS. ALL WATER MAINS TO BE INSTALLED WITH A POLYETHYLENE WRAP AROUND
6. THE WESTCHESTER COUNTY HEALTH DEPARTMENT, TOWN OF CORTLANDT DEPARTMENT THE PIPE FOR CORROSION PROTECTION. DUCTILE IRON PIPE WRAPPING
OF TECHNICAL SERVICES (D.O.T.S.), WESTCHESTER JOINT WATER WORKS, AND OWNER SHALL BE LINEAR LOW DENSITY POLYETHYLENE SHEETING AND TUBING 8
MUST BE NOTIFIED AT LEAST 48 HOURS IN ADVANCE OF ANY PRESSURE TEST. MIL LLDPE AS MANUFACTURED BY INFINITY PLASTIC LLC
PARCEL 3 -
SUPPORT BOX WITH MINIMUM OF
THREE (3) COURSES OF BRICK 7. ALL WATER MAINS TO BE INSTALLED WITH A POLYETHYLENE WRAP AROUND THE PIPE
FOR CORROSION PROTECTION,
SITE DETAILS
8. ADEQUATE COVER OF WATERMAIN SHALL BE PROVIDED.
SEWER NOTES:
COMPACTED BACKFILL TO
1. ALL SANITARY SEWER PIPES TO BE DUCTILE IRON PIPE, CLASS 52, CEMENT LINED. DOMESTIC NOTE:
NATURAL GROUND
MATERIALS ONLY. NO IMPORTS. ALL SANITARY SEWER MAINS TO BE INSTALLED WITH A POLYETHYLENE
CONCRETE BEARING PAD TO BE 2. SANITARY SEWER PIPES SHALL BE AIR TESTED IN ACCORDANCE WITH ASTM C 924. WRAP AROUND THE PIPE FOR CORROSION PROTECTION. DUCTILE IRON PIPE
USED WITH PVC PIPE BRICKS TO 3. SANITARY MANHOLES SHALL BE VACUUM TESTED IN ACCORDANCE WITH ASTM C 1244. WRAPPING SHALL BE LINEAR LOW DENSITY POLYETHYLENE SHEETING AND
BEAR ON PAD 4. THE MINIMUM SEWER INSTALLATION DEPTH WILL BE AT LEAST FOUR (4) FEET BELOW THE
FINISHED GROUND SURFACE (MEASURED FROM TOP OF PIPE). THE MINIMUM REQUIRED
TUBING 8 MIL LLDPE AS MANUFACTURED BY INFINITY PLASTIC LLC
NOTE:
1. VALVE BOXES SHALL BE MADE IN THE U.S.A. SEPARATION BETWEEN WATER MAIN AND SANITARY SEWER/STORM DRAIN PIPING SHALL BE
2. SIMILAR INSTALLATION FOR CURB BOX OR EIGHTEEN (18") INCH VERTICAL, TEN (10') FOOT HORIZONTAL. THE MINIMUM REQUIRED TEN
SERVICE LINE VALVE SIZE + 12" (10') FOOT HORIZONTAL SEPARATION IS ALSO APPLICABLE BETWEEN WATER MAINS AND
SANITARY SEWER MANHOLES, STORM DRAIN MANHOLES AND CATCH BASINS.
5. THE WESTCHESTER COUNTY HEALTH DEPARTMENT, TOWN OF CORTLANDT DEPARTMENT OF
NOTE:
SP-6.3
TECHNICAL SERVICES (D.O.T.S.), ENGINEER, AND OWNER MUST BE NOTIFIED AT LEAST 48
HOURS IN ADVANCE OF ANY TEST. NO RECYCLED MATERIAL SHALL BE USED AS PIPE BEDDING
TYPICAL VALVE INSTALLATION BOX 6. THE APPLICANT'S ENGINEER SHALL BE PRESENT FOR ALL TESTING. OR BACKFILL OF ANY PUPLIC INFRASTRUCTURE
7
SCALE: N.T.S.
Page 98
NOTE:
1. WALL DRAIN SHALL NOT DISCHARGE TO ANY STORMWATER TREATMENT PRACTICE.
2. CONTRACTOR SHALL SUBMIT A BUILDING PERMIT FOR THE CONSTRUCTION OF THE
RETAINING WALL.
3. THE TOWN WILL REQUIRE CERTIFICATION FROM A LICENSED NYS ENGINEER INDICATING
THE RETAINING WALL WAS CONSTRUCTED IN ACCORDANCE WITH THE ENGINEERING
DESIGN PLANS AND REPORTS.
EVERGREEN MANOR
Town of Cortlandt, New York
OWNER / APPLICANT
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
OSSINING, NY 10562
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
WHITE PLAINS, NY 10601
SURVEYOR
DANIEL T. MERRITTS, PLS
394 BEDFORD ROAD
PLEASANTVILLE, NY 10570
WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
10 NORTH STREET
COLD SPRING, NY 10516
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
1-800-962-7962 OR 811
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
SITE DETAILS
03/25/26
SP-6.4
Page 99
RETAINING WALL NOTES:
1. THE CONTRACTOR SHALL SUBMIT A BUILDING PERMIT FOR THE
CONSTRUCTION OF THE RETAINING WALL.
2. THE TOWN WILL REQUIRE THE CONTRACTOR TO SUBMIT CERTIFICATION
FROM A LICENSED NYS ENGINEER INDICATING THE RETAINING WALL WAS
CONSTRUCTED IN ACCORDANCE WITH THE ENGINEERING DESIGN PLANS
AND REPORTS SUBMITTED AND APPROVED BY BUILDING PERMIT.
3. THE CONTRACTOR SHALL NOT PERMIT ANY WALL DRAIN TO DISCHARGE
DIRECTLY TO ANY STORMWATER TREATMENT PRACTICE. EVERGREEN MANOR
Town of Cortlandt, New York
OWNER / APPLICANT
V.S. CONSTRUCTION CORPORATION
37 CROTON DAM ROAD
OSSINING, NY 10562
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
One North Broadway
White Plains, NY 10601
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
WHITE PLAINS, NY 10601
SURVEYOR
DANIEL T. MERRITTS, PLS
394 BEDFORD ROAD
PLEASANTVILLE, NY 10570
WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
10 NORTH STREET
COLD SPRING, NY 10516
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
1-800-962-7962 OR 811
Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
SITE DETAILS
03/25/26
SP-6.5
Page 100
EVERGREEN MANOR
Town of Cortlandt, New York
1
R
= 0 1,711
IGH
= 4 REA
PA OF W
.9
A
5
OWNER / APPLICANT
R
T
8 A .617 S
C
V.S. CONSTRUCTION CORPORATION
EL AY
37 CROTON DAM ROAD
c
OSSINING, NY 10562
r es .F.
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
L=23.55'
R=25.00'
One North Broadway
White Plains, NY 10601
PROPOSED
MONUMENT
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
40.2
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
8.283 17.75 4.5 81 MAIN STREET
20 WHITE PLAINS, NY 10601
Cortlandt (T) - Lake Mohegan Fire Truck SURVEYOR
Overall Length 40.200ft
Overall Width 8.250ft DANIEL T. MERRITTS, PLS
Overall Body Height 11.830ft 394 BEDFORD ROAD
Min Body Ground Clearance 0.742ft PLEASANTVILLE, NY 10570
Track Width 8.250ft
Lock-to-lock time 4.00s
Curb to Curb Turning Radius 38.500ft WETLAND CONSULTANT
TIM MILLER ASSOCIATES, INC.
PROPERTY LINE,
TYP. 10 NORTH STREET
COLD SPRING, NY 10516
R-40
PROPERTY LINE, MONUMENT
(TYP.) PROPOSED
30' SIDE YARD SETBACK/
NONDISTURBANCE AREA
Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ
6
Λ Λ Λ
22.0'
Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ Λ
Λ Λ
Λ
Λ
Λ
Λ
MO OPOSE
Λ
7
Λ
PR
Λ
Λ
Λ
Λ
N
Λ Λ Λ Λ
Λ Λ Λ Λ Λ
Λ
U
Λ
Λ
Λ Λ Λ
Λ
MEND
Λ Λ
Λ
Λ Λ Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ Λ
Λ Λ
7
Λ Λ Λ Λ
T
Λ
Λ Λ
7.5 '
Λ Λ Λ Λ
'
Λ
69.5
Λ
7 N2
Λ
Λ Λ Λ Λ Λ Λ
9° 0
Λ Λ
Λ
Λ Λ
Λ
Λ
6' 1
Λ
Λ
Λ
E
Λ
Λ
ENU
Λ
9" E
Λ
Λ Λ
Λ
Λ Λ
34.
Λ
Λ
Λ
E AV
Λ Λ
Λ Λ
65'
Λ
Λ Λ
18.0
Λ Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
YETT
Λ Λ
Λ
Λ
Λ ' Λ
Λ PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
1-800-962-7962 OR 811
Λ
Λ
Λ
LAFA
Λ
Λ
8.0 '
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
7.5 '
X
Λ
5
Λ
R10.0 '
0'
25'
Λ
Λ
X
18.
Λ
4
Λ
Λ
9.0 '
X
Λ
Λ
'
Λ
20.0
X
Λ
Λ
Λ
Λ
Λ
X
Λ
10 NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
Λ
Λ
Λ
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
6
X
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
2 ' ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
0.0
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
R1 WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
Λ
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
9 MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
Λ
SHOWN BY THESE DRAWINGS.
Λ
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Λ
30' FRONT YARD SETBACK Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
323.99' 30' FRONT YARD SETBACK
S 76° 13' 31" E
1 01/21/2026 SITE PLAN APPLICATION
S 77
2 02/18/2026 ISSUE TO PLANNING BOARD
4 3"
E
'4 1 3 03/25/2026 ISSUE TO PLANNING BOARD
° 37 64.77'
42
8°
N7
' 03
"W
7'
3.6
25
PR NUM
MO
OP EN
OS T
ED
ON
D RO
AD
02
MOD
O MP E 35/2
C R OUT
R
PARCEL 3 -
EMERGENCY SERVICE VEHICLE
MANEUVERING PLAN
Cortlandt (
T) - Lake M
SP-12.0
o
CONKLIN
hegan Fire
AVENUE
PROPERTY LINE
ruck T
(TYP.)
Page 101
EVERGREEN MANOR
Town of Cortlandt, New York
1
R
= 0 1,711
IGH
= 4 REA
PA OF W
.9
A
5
OWNER / APPLICANT
R
T
8 A .617 S
C
V.S. CONSTRUCTION CORPORATION
EL AY
37 CROTON DAM ROAD
c
OSSINING, NY 10562
r es .F.
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
L=23.55'
R=25.00'
One North Broadway
White Plains, NY 10601
PROPOSED
MONUMENT
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
32.8
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
3.5 18.3 4.8
20.7 WHITE PLAINS, NY 10601
Front Loader Garbage Truck SURVEYOR
Overall Length 32.800ft DANIEL T. MERRITTS, PLS
Overall Width 8.500ft
Overall Body Height 10.499ft 394 BEDFORD ROAD
Min Body Ground Clearance 1.398ft PLEASANTVILLE, NY 10570
Track Width 8.500ft
Lock-to-lock time 6.00s WETLAND CONSULTANT
Wall to Wall Turning Radius 42.000ft
TIM MILLER ASSOCIATES, INC.
PROPERTY LINE,
TYP. 10 NORTH STREET
COLD SPRING, NY 10516
R-40
PROPERTY LINE, MONUMENT
(TYP.) PROPOSED
30' SIDE YARD SETBACK/
NONDISTURBANCE AREA
Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ
6
Λ Λ Λ
22.0'
Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ Λ
Λ Λ
Λ
Λ
Λ
Λ
MO OPOSE
Λ
7
Λ
PR
Λ
Λ
Λ
Λ
N
Λ Λ Λ Λ
Λ Λ Λ Λ Λ
Λ
U
Λ
Λ
Λ Λ Λ
Λ
MEND
Λ Λ
Λ
Λ Λ Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ Λ
Λ Λ
7
Λ Λ Λ Λ
T
Λ
Λ Λ
7.5 '
Λ Λ Λ Λ
'
Λ
69.5
Λ
7 N2
Λ
Λ Λ Λ Λ Λ Λ
9° 0
Λ Λ
Λ
Λ Λ
Λ
Λ
6' 1
Λ
Λ
Λ
E
Λ
Λ
ENU
Λ
9" E
Λ
Λ Λ
Λ
Λ Λ
34.
Λ
Λ
Λ
E AV
Λ Λ
Λ Λ
65'
Λ
Λ Λ
18.0
Λ Λ
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
YETT
Λ Λ
Λ
Λ
Λ ' Λ
Λ PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
1-800-962-7962 OR 811
Λ
Λ
Λ
LAFA
Λ
Λ
8.0 '
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
7.5 '
X
Λ
5
Fro
Λ
R10.0 '
0'
nt Load
25'
Λ
Λ
X
18.
e
Λ
4
r G
Λ
ar
Λ
b
9.0 '
age Truc
X
Λ
Λ
'
Λ
20.0
k
X
Λ
Λ
Λ
Λ
Λ
X
Λ
10 NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
Λ
Λ
Λ
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
6
X
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
2 ' ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
0.0
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
R1 WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
Λ
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
9 MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
Λ
SHOWN BY THESE DRAWINGS.
Λ
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Λ
30' FRONT YARD SETBACK Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
323.99' 30' FRONT YARD SETBACK
S 76° 13' 31" E
1 01/21/2026 SITE PLAN APPLICATION
S 77
2 02/18/2026 ISSUE TO PLANNING BOARD
4 3"
E
'4 1 3 03/25/2026 ISSUE TO PLANNING BOARD
° 37 64.77'
42
8°
N7
' 03
"W
7'
3.6
25
PR NUM
MO
OP EN
OS T
ED
ON
D RO
AD
02
MOD
O MP E 35/2
C R OUT
R
PARCEL 3 -
FRONT LOADER GARBAGE
TRUCK MANEUVERING PLAN
SP-12.1
CONKLIN
AVENUE
PROPERTY LINE
(TYP.)
Page 102
EVERGREEN MANOR
Town of Cortlandt, New York
1
R
= 0 1,711
IGH
= 4 REA
PA OF W
.9
A
5
OWNER / APPLICANT
R
T
8 A .617 S
C
V.S. CONSTRUCTION CORPORATION
EL AY
37 CROTON DAM ROAD
c
OSSINING, NY 10562
r es .F.
PLANNER, CIVIL ENGINEER, LANDSCAPE
ARCHITECT
DTS PROVIDENT
Intelligent Land Use
DTS Provident Design Engineering, LLP CA #: 0017846
L=23.55'
R=25.00'
One North Broadway
White Plains, NY 10601
PROPOSED
MONUMENT
P: 914.428.0010
F: 914.428.0017
ARCHITECT - PARCEL 3
30
BEATTY HARVEY COCO ARCHITECTS
1300 WALT WHITMAN ROAD
MELVILLE, NY 11747
LAND USE ATTORNEY
ZARIN & STEINMETZ
81 MAIN STREET
4 20 WHITE PLAINS, NY 10601
SURVEYOR
SU-30 - Single Unit Truck
Overall Length 30.000ft DANIEL T. MERRITTS, PLS
Overall Width 8.000ft 394 BEDFORD ROAD
Overall Body Height 13.500ft PLEASANTVILLE, NY 10570
Min Body Ground Clearance 1.367ft
Track Width 8.000ft
Lock-to-lock time 5.00s WETLAND CONSULTANT
Max Steering Angle (Virtual) 31.80° TIM MILLER ASSOCIATES, INC.
PROPERTY LINE,
TYP. 10 NORTH STREET
COLD SPRING, NY 10516
R-40
PROPERTY LINE, MONUMENT
(TYP.) PROPOSED
30' SIDE YARD SETBACK/
NONDISTURBANCE AREA
Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ Λ Λ
Λ
Λ Λ Λ
6
Λ Λ Λ
22.0'
Λ
Λ Λ Λ
Λ
Λ Λ Λ Λ Λ
Λ Λ
Λ
Λ
Λ
Λ
MO OPOSE
Λ
7
Λ
PR
Λ
Λ
Λ
Λ
N
Λ Λ Λ Λ
Λ Λ Λ Λ Λ
Λ
U
Λ
Λ
Λ Λ Λ
Λ
MEND
Λ Λ
Λ
Λ Λ Λ Λ
Λ
Λ
Λ
Λ
Λ
Λ Λ
Λ Λ
7
Λ Λ Λ Λ
T
Λ
Λ Λ
7.5 '
Λ Λ Λ Λ
'
Λ
69.5
Λ
7 N2
Λ
Λ Λ Λ Λ Λ Λ
9° 0
Λ Λ
Λ
Λ Λ
Λ
Λ
6' 1
Λ
Λ
Λ
E
Λ
Λ
ENU
Λ
9" E
Λ
Λ Λ
Λ
Λ Λ
34.
Λ
Λ
Λ
E AV
Λ Λ
SU-3
Λ Λ
65'
Λ
Λ Λ
18.0
Λ Λ
S0 - ingle U
THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY
YETT
Λ Λ
Λ
Λ
' Λ
PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN THE STATE.
nit Truc
1-800-962-7962 OR 811
Λ Λ
Λ
Λ
Λ
k
LAFA
Λ
Λ
8.0 '
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
Λ
7.5 '
X
Λ
5
Λ
R10.0 '
0'
25'
Λ
Λ
X
18.
Λ
4
Λ
Λ
9.0 '
X
Λ
Λ
'
Λ
20.0
X
Λ
Λ
Λ
Λ
Λ
X
Λ
10 NOTE: ALL SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED
Λ
Λ
Λ
BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT
6
X
DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE
Λ
2 ' ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT INDICATED HEREON AND
0.0
Λ
SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER
R1 WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP.
Λ
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED
Λ
9 MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
Λ
DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS
Λ
SHOWN BY THESE DRAWINGS.
Λ
LEGAL NOTICE: IT IS A VIOLATION OF ARTICLE 145 OF THE NEW
YORK STATE EDUCATION LAW FOR ANY PERSON TO ALTER THIS
Λ
DOCUMENT IN ANY WAY EXCEPT AS PROVIDED IN SECTION
7209 (2), ARTICLE 145, NEW YORK STATE EDUCATION LAW.
Λ
Λ
30' FRONT YARD SETBACK Copyright DTS Provident Design Engineering, LLP 2025
All rights reserved.
NOT FOR CONSTRUCTION
323.99' 30' FRONT YARD SETBACK
S 76° 13' 31" E
1 01/21/2026 SITE PLAN APPLICATION
S 77
2 02/18/2026 ISSUE TO PLANNING BOARD
4 3"
E
'4 1 3 03/25/2026 ISSUE TO PLANNING BOARD
° 37 64.77'
42
8°
N7
' 03
"W
7'
3.6
25
PR NUM
MO
OP EN
OS T
ED
ON
D RO
AD
02
MOD
O MP E 35/2
C R OUT
R
PARCEL 3 -
DELIVERY TRUCK
MANEUVERING PLAN
SP-12.2
CONKLIN
AVENUE
PROPERTY LINE
(TYP.)
Page 103
March 26, 2026
To: Cortlandt Manor Planning Board Members
Mr. Chris Kehoe, AICP, Director
Ms. Heather LaVarnway, CNU-A, Planner
RE: 1201 Oregon Rd. (Wilmar Electric) Section 13.9, Block 3, Lot 5 – Response to
Department of Planning & Community Development December 3, 2024 Comments
To Planning Board Members:
This letter shall serve as a response to comments provided by The Department of Planning and
Community, December 3, 2024 comments memo. The plans have been revised and separated for
clarity. The Engineering portion of the plans have been prepared by AC Engineering, PLLC while
the architectural components of the building have been revised by the architect, AIA Studio RAI
Architects.
2a. The proposed landscaping shown in the previous architect plans have been
removed and no additional landscaping is proposed.
2b. No new signs are proposed to be displayed on this property. The existing sign will
remain.
2c. The make, model and size of the commercial vehicles are shown on the site plans.
3. The zoning schedule has been revised and shown in the Architect plans as well as
on the Proposed Conditions Site Plan.
4. The written analysis for both Section 307-65.6 and 307-42 is included in this
submittal.
5. Outdoor lighting and lighting plan is included as part of this submittal.
6. The revised parking spaces and schedules are shown on the Proposed Conditions
site plan as well as the Architect Plans.
7. The location of the proposed dumpsters have been relocated to the area where
existing dumpsters are placed.
Page 104
Town of Cortlandt Manor Planning Board Members
March 26, 2026
Page 2
8. The arborvitae along the east of the entrance drive is existing and shown in the
Existing conditions site plan.
9. The existing shingle roof are in good condition and will remain as-is.
10. The existing siding of the building will be painted.
11. A detail of the masonry block wall is shown in the details of the Engineering
plans.
12. Comments provided by LaBella have been addressed in the revised plans.
13. Upon planning board approval, building permits will be obtained.
We hope this letter satisfies your concerns and comments. Please feel free to contact us if you
should have any questions or require additional clarification.
Respectfully submitted,
AC Engineering, PLLC.
Andy Cheung, P.E., CPESC
Principal Engineer
Cc: Mario Alvarez – Owner
Cortlandt Manor Planning Board
Page 105
March 26, 2026
To: Cortlandt Manor Planning Board Members
Mr. Chris Kehoe, AICP, Director
Mr. Christopher Lapine, P.E., LEED AP
LaBella Associates, DPC
RE: 1201 Oregon Rd. (Wilmar Electric) Section 13.9, Block 3, Lot 5 – Response to LaBella
Associates November 27, 2024 Comments
To Planning Board Members:
This letter shall serve as a response to LaBella Associates, November 27, 2024 comments memo.
The plans have been revised and separated for clarity. The Engineering portion of the plans have
been prepared by AC Engineering, PLLC while the architectural components of the building have
been revised by the architect, AIA Studio RAI Architects.
Administrative
1) The on-site septic disposal system was abandoned/removed by the previous owner before
the current owner purchased the property. It is assumed the previous owner has filed this
with the Town.
2) A new set of construction drawings have been prepared and will be submitted to the Town
for review.
3) This project does not involve any excavation or topsoil removal. The scope of work
includes the removal of the existing asphalt and repaving to the same footprint as the
existing asphalt area.
4) A phone conversation with the Town Clerk confirmed the property is already connected to
the Town sewer.
Environmental Access Form
1) The total acreage to be disturbed has been added to Line 3 of the EAF.
2) There will be no change to the existing stormwater collection system.
Plans
Page 106
Town of Cortlandt Manor Planning Board Members
March 26, 2026
Page 2
A new set of plans have been prepared showing the site improvements; mainly the re-
paving of the existing dilapidated asphalt, the creation of painted parking spaces, the addition of
additional parking lot lighting and the addition of a new water tap connection to the existing
watermain for the proposed fire suppression system.
The fire sprinkler system design including the backflow preventer will be designed by a separate
Engineer. The Owner has confirmed the domestic water supply line is protected with a WCDOH
approved backflow prevention device.
There are no curbs proposed on this lot. Pre-cast concrete curbs will be placed at each parking
spot.
The existing retaining wall will be removed and a new retaining wall is proposed at the same
location. This new retaining wall is shown and detailed in the revised plans. The proposed
dumpsters will be located at the back of the parking area at the end of this new retaining wall.
There are no other improvements proposed to this site for stormwater collection. The existing
stormwater collection system will remain undisturbed. There are also no additional increases to
impervious areas on this lot and there is no re-grading of the subgrade after asphalt removal. There
is no additional plantings proposed on this lot.
1) The following notes have been added to the plans.
a. There will be no disturbance to the existing stone retaining walls on either side of
the existing and proposed parking areas. Applicant/Contractor/Design Professinoal
all acknowledge that if during the course of construction, any wall is impacted, they
shall immediately notify the Department of Technical Services and file appropriate
permits prior to any work commencing.
b. The Applicant is aware that the disturbed areas shall be 100% stabilized and planted
prior to the issuance of the Certificate of Occupancy.
c. The applicant shall submit an as-built foundation survey to the Town of Cortlandt
prior to framing.
d. Prior to the backfilling of any storm water best management practice, DOTS-
Engineering shall be notified to perform an inspection.
e. All proposed import fill must be tested and certified as unrestricted, suitable for
residential use in accordance with Town Policy. Certification must be provided by
a licensed professional. All certifications shall be addressed to Town’s Planning
Board Engineer. All soil analytics and reports will be forwarded to the Town’s
Planning Board Engineer for review and approval.
Page 107
Town of Cortlandt Manor Planning Board Members
March 26, 2026
Page 3
f. Prior to the issuance of the Certificate of Occupancy, the Town will require a
certification from a NYS Engineer that the completed site work and drainage
improvements will not cause an adverse impact to adjoining or downstream
properties.
g. Backflow prevention devices shall be designed and installed in accordance with
University of Southern California List of Approved Backflow Prevention Devices,
NYSDOH Guidelines for Designing Backflow Prevention Assembly Installations,
and Building Code.
We hope this letter satisfies your concerns and comments. Please feel free to contact us if you
should have any questions or require additional clarification.
Respectfully submitted,
AC Engineering, PLLC.
Andy Cheung, P.E., CPESC
Principal Engineer
Cc: Mario Alvarez – Owner
Cortlandt Manor Planning Board
Page 108
SPECIALTY TRADE CONTRACTORS - COMPLIANCE
SECTION 307-65.6
A. The setback from residential districts shall be two times the required setback set forth in
the Table of Dimensional Regulations.[1] Buffers shall be enhanced with suitable
landscaping as determined by the Planning Board.
The property is split-zoned CC along Oregon Road and zoned R-10 residential in the rear
of the property with adequate setbacks on the residential portion. See zoning chart in
Architect’s plans.
B. On-site contractor operations. Noise levels shall not exceed 65 dB for more than two hours
in total during any workday at the boundaries of residential districts, nor shall any
unreasonably intrusive noise be created. An "unreasonably intrusive noise" is any sound
which would annoy, disturb or irritate a reasonable person of normal sensitivities under
the same circumstances. Otherwise operations shall not exceed 55 dB during the workday
at the boundaries of the residential districts.
The building will be utilized as office space and residential combined. Therefore it is not
anticipated that noise levels exceed that of typical office buildings and apartments.
C. Fugitive dust or odors from contractor activities must be contained on site. The Planning
Board may require periodic off-site air testing as directed by the Director of Technical
Services.
There are no contractor activities anticipated during the course of the work day.
D. Impervious coverage shall be limited to 55% of the site, including the building coverage.
The building and paved parking area totals 17,039 SF of impervious surface. The total site
area is 74,147 SF therefore the impervious area accounts for 23% of the site.
E. The Planning Board may require truck counters to be located at the entrance to the facility
and require that the number of daily truck trips be monitored for a period of time following
the issuance of a certificate of occupancy, not exceeding a period of two years, at the
applicant's expense, for the purpose of validating the traffic projections and impacts
created thereby.
Page 109
Specialty Trade Contractors - Compliance
Page 2
The space will be utilized as an office and apartments and therefore limited truck traffic is
expected.
F. Outdoor storage of materials shall not exceed 20% of the developed site. Storage piles
shall not exceed a height of 10 feet. The Planning Board may require that the storage piles
be located within buildings or open sheds. Outside storage shall be limited to those specific
locations approved by the Planning Board.
No storage is expected on the exterior of the building.
G. The Planning Board may impose such additional standards in order to prevent a nuisance
to neighboring properties by reason of dust or odor or any other reason.
It is not anticipated the office and apartments will generate dust or odor.
H. Business activities and maintenance activities requiring the use of machinery, equipment
or power tools shall be permitted between the hours of 7:00 a.m. and 7:00 p.m. on
weekdays and from 8:00 a.m. to 5:00 p.m. on Saturdays. All such work is prohibited on
Sundays and legal holidays. The Planning Board may vary the above times by not more
than two hours.
The office space will only be open during business hours. There are no power tools,
machinery or equipment anticipated to be used during those hours.
I. The Planning Board may require that security fencing be located around areas or
structures to address safety concerns.
There are no current proposals for security fencing for the office and apartments.
J. Permit duration and renewal. Permits shall be issued conditionally for a three-year period
upon a showing of compliance with the terms and conditions of this chapter and the special
permit during the preceding permit period.
Noted.
K. Unless set forth above, no variance of any of the above conditions are authorized.
Noted.
L. Nothing contained herein shall prohibit the processing and crushing of aggregate on the
site of any approved subdivision and/or site plan to be utilized solely on site for the
construction of the improvements required by the approval.
Page 110
Specialty Trade Contractors - Compliance
Page 3
The space will be used as an office building and apartments and therefore there is no
crushing of aggregate expected on site.
Page 111
GENERAL CONDITIONS AND STANDARDS - COMPLIANCE
SECTION 307-42
(1)
The use shall be of such location, size, intensity of operation and character that, in general, it will
be in harmony with the appropriate and orderly development of the district in which it is situated
and will not be detrimental to adjacent land and buildings nor impair the value thereof nor hinder
the orderly development of adjacent districts.
The use of the existing renovated building will be consistent with other existing buildings in the
vicinity. It will not be detrimental to adjacent land and buildings nor impair the value of
surrounding properties.
(2)
The location and size of the use, the nature and intensity of the operations involved in or conducted
in connection with it, its site layout and its relation to streets giving access to it shall be such that
both pedestrian and vehicular traffic to and from the use and the assembly of persons in connection
with it will not be hazardous or inconvenient to the predominant residential or other prevailing
character of the neighborhood.
The location and size of the building is consistent with other buildings in the vicinity. There is a
traffic light at the intersection allowing for safe entry and exit from the property.
(3)
The number, location, nature and height of buildings, walls and fences and the nature and extent
of the landscaping on the site shall be such that the use will not hinder or discourage the
appropriate development and use of adjacent land and buildings or impair the value thereof.
The existing building and future renovation is aesthetically consistent with other buildings in the
area. There will be no removal of existing landscaping.
(4)
The location and size of the use and the nature and intensity of the operations involved in or
conducted in connection with it shall be such that the use will not adversely affect nearby existing
uses, nor will it be detrimental to the existing or potential use and value of land and buildings in
the vicinity by reason of noise, vibration, excessive light, smoke, gas, fumes, odor or other
atmospheric pollutant or danger of fire or explosion.
It is not anticipated the office building and apartments will emit atmospheric pollutants. A separate
sprinkler system will be installed in the renovated building.
Page 112
Section 307-42 General Conditions and Standards - Compliance
Page 2
(5)
Parking areas shall be of adequate size for the particular use, properly located and suitably
screened from adjoining residential uses, and the entrance and exit drives shall be laid out so as
to prevent traffic hazards and nuisances.
The parking areas are in the rear of the building and not visible from the street. There is a traffic
light at the intersection allowing a safe passage into and out of the property.
(6)
The use as proposed will not require such additional public facilities or services, such as sewerage
systems, storm drainage systems, public water supplies, recreational systems and street systems,
to be provided at public expense or create unacceptable environmental or fiscal burdens upon the
Town.
The renovated office building and apartments will generate and use similar quantities of
water/wastewater as the previous building and should not create additional environmental or fiscal
burden.
(7)
The proposed use is developed such that the existing land form is preserved in its natural state,
insofar as practicable, by minimizing grading and the erosion or stripping of steep slopes and by
maintaining man-made features that enhance the land form, such as stone walls, with minimal
alteration or disruption. In addition, all open spaces should be designed and planted to enhance
the attractiveness of the neighborhood.
There is no grading proposed on the property. All existing stone walls will remain. The retaining
wall in the rear of the property will be replaced.
(8)
The proposed buildings are located harmoniously with the land form, vegetation and other natural
features of the site; compatible in scale, design and use with those buildings and designs which
are visually related to the development site; effectively located for solar and wind orientation for
energy conservation; and advantageously located for views from the building while minimizing
the intrusion on views from other buildings.
The renovated building situates in the same location as previously constructed. Renovations to
the exterior are cosmetic in nature. The majority of the renovations occur inside the building.
(9)
The proposed use is consistent with the Town Master Plan, meets applicable requirements of the
New York State Uniform Fire Prevention and Building Code and receives all required county,
state and federal approvals.
Page 113
Section 307-42 General Conditions and Standards - Compliance
Page 3
The proposed use of the building is consistent with the Town Master Plan and will meet all building
code, fire, electrical, and plumbing codes.
Page 114
Short Environmental Assessment Form
Part 1 - Project Information
Instructions for Completing
Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the
application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on
information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as
thoroughly as possible based on current information.
Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the
lead agency; attach additional pages as necessary to supplement any item.
Part 1 – Project and Sponsor Information
Name of Action or Project:
RENOVATION OF EXISTING BUILDING AT 1201 OREGON ROAD
Project Location (describe, and attach a location map):
1201 OREGON ROAD, CORTLANDT MANOR, NY
Brief Description of Proposed Action:
AN EXISTING COMMERCIAL BUILDING IS PROPOSED TO BE RENOVATED AND UPDATED. THE EXISTING PARKING LOT AREA WILL ALSO
BE RENOVATED WITH ADDITONAL LIGHTING AND NEW PARKING SPOTS AFTER THE EXISTING ASPHALT IS REMOVED AND NEW
ASPHALT INSTALLED. THE FOOTPRINT AND GRADES WILL REMAIN UNCHANGED.
Name of Applicant or Sponsor: Telephone:
ANDY CHEUNG, P.E. E-Mail:
Address:
City/PO: State: Zip Code:
NY
1. Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, NO YES
administrative rule, or regulation?
If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that
✔
may be affected in the municipality and proceed to Part 2. If no, continue to question 2.
2. Does the proposed action require a permit, approval or funding from any other government Agency? NO YES
If Yes, list agency(s) name and permit or approval:
✔
3. a. Total acreage of the site of the proposed action? __________
1.7 acres
b. Total acreage to be physically disturbed? __________
0.4 acres
c. Total acreage (project site and any contiguous properties) owned
or controlled by the applicant or project sponsor? __________
1.7 acres
4. Check all land uses that occur on, are adjoining or near the proposed action:
□ Urban Rural (non-agriculture) Industrial ✔ Commercial ✔ Residential (suburban)
□ Forest Agriculture Aquatic Other(Specify):
Parkland
Page 1 of 3 SEAF 2019
Page 115
5. Is the proposed action, NO YES N/A
a. A permitted use under the zoning regulations?
✔
b. Consistent with the adopted comprehensive plan? ✔
NO YES
6. Is the proposed action consistent with the predominant character of the existing built or natural landscape?
✔
7. Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? NO YES
If Yes, identify: ________________________________________________________________________________
✔
NO YES
8. a. Will the proposed action result in a substantial increase in traffic above present levels?
✔
b. Are public transportation services available at or near the site of the proposed action?
✔
c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed
action?
✔
9. Does the proposed action meet or exceed the state energy code requirements? NO YES
If the proposed action will exceed requirements, describe design features and technologies:
_____________________________________________________________________________________________
AS PER ARCHITECT'S PLANS THE BUILDING WILL BE RENOVATED AS PER THE LATEST NYS STRETCH CODES ✔
_____________________________________________________________________________________________
10. Will the proposed action connect to an existing public/private water supply? NO YES
If No, describe method for providing potable water: _________________________________________
✔
_____________________________________________________________________________________________
11. Will the proposed action connect to existing wastewater utilities? NO YES
If No, describe method for providing wastewater treatment: ______________________________________
✔
_____________________________________________________________________________________________
12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district NO YES
which is listed on the National or State Register of Historic Places, or that has been determined by the
Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the ✔
State Register of Historic Places?
✔
b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for
archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory?
13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain NO YES
wetlands or other waterbodies regulated by a federal, state or local agency?
✔
b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody?
✔
If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page 2 of 3
Page 116
14. Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply:
□Shoreline □ Forest Agricultural/grasslands Early mid-successional
Wetland □ Urban ✔ Suburban
✔
15. Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or NO YES
Federal government as threatened or endangered?
✔
16. Is the project site located in the 100-year flood plan? NO YES
✔
NO YES
17. Will the proposed action create storm water discharge, either from point or non-point sources?
If Yes, ✔
a. Will storm water discharges flow to adjacent properties? ✔
b. Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? ✔
If Yes, briefly describe:
_____________________________________________________________________________________________
THERE ARE EXISTING STORMWATER CATCH BASINS ON THE PROPERTY THAT WILL REMAIN. THESE CONNECT TO THE
_____________________________________________________________________________________________
TOWN STORMWATER SYSTEM.
18. Does the proposed action include construction or other activities that would result in the impoundment of water NO YES
or other liquids (e.g., retention pond, waste lagoon, dam)?
If Yes, explain the purpose and size of the impoundment:______________________________________________
✔
____________________________________________________________________________________________
_ Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste
19. NO YES
management facility?
If Yes, describe: _______________________________________________________________________________
✔
_____________________________________________________________________________________________
20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or NO YES
completed) for hazardous waste?
If Yes, describe: _______________________________________________________________________________
✔
_____________________________________________________________________________________________
I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF
MY KNOWLEDGE
Applicant/sponsor/name: ____________________________________________________
ANDY CHEUNG, P.E. __________________________
Date: 2/5/26
_____________________
Signature: __ ______________________________Title:__________________________________
ENGINEER
PRINT FORM Page 3 of 3
Page 117
PLANS FOR
1201 OREGON ROAD
PROPOSED ALTERATION
TOWN OF CORTLANDT MANOR, WESTCHESTER COUNTY, NEW YORK
MARCH 2025
REVISED: MARCH 2026
INDEX OF DRAWINGS
1 EXISTING CONDITIONS PLAN
2 PROPOSED CONDITIONS PLAN
3 SOIL EROSION AND SEDIMENT CONTROL DETAILS
4 DETAILS
1201 OREGON ROAD
5 RETAINING WALL DETAILS
1201 OREGON ROAD
6 RETAINING WALL CALCULATIONS
WARNING: IT IS A VIOLATION OF NEW YORK EDUCATIONAL LAW, SECTION 7209.2, FOR
ANY PERSON, UNLESS HE IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL
ENGINEER OR LAND SURVEYOR, TO ALTER THIS DOCUMENT IN ANY WAY. IF ALTERED,
THE ALTERING PERSON SHALL COMPLY WITH THE REQUIREMENTS OF NEW YORK
EDUCATIONAL LAW, SECTION 7209.2
PREPARED BY:
AC ENGINEERING, PLLC
9 DUNHILL DR.
SOMERS, NY 10589
(914) 260-4239
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM
LOCATION MAP ORTHOIMAGE
HTTP://ACENGINEERINGPLLC.COM
SITE PHOTO #1 SITE PHOTO #2 SITE PHOTO #3 SITE PHOTO #3
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
CS
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE (914) 260-4239 PROPOSED OFFICE RENOVATION
ALTERING PERSON SHALL COMPLY WITH THE PROJECT NO.
MARCH 2025 HTTPS://ACENGINEERINGPLLC.COM
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM COVER SHEET CM-120OR-SD
Page 118
LOCATION PLAN
N.T.S.
SOILS MAP
N.T.S.
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
1
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM EXISTING CONDITIONS SITE PLAN CM-1201OR-SD
Page 119
ZONING SCHEDULE TOWN OF CORTLAND
ZONE / USE : CC
ITEM REQUIRED EXISTING PROVIDED
7,500 SQ FT 74,146.5 SQ FT NO
MINIMUM LOT SIZE (SQ. FT.)
CHANGE
60 FEET 183'-6" NO
MINIMUM LOT WIDTH (FEET) CHANGE
MINIMUM FRONT YARD 30 FEET 11'-8" NO
ZONE / USE : R-10 (FEET) CHANGE
ITEM REQUIRED EXISTING PROVIDED MINIMUM EACH SIDE YARD 10 FEET 56'-4", 73'-1 1/2" NO
(FEET) CHANGE
MINIMUM LOT SIZE (SQ. FT.) 10,000 SQ FT 74,146.5 SQ FT NO
CHANGE MINIMUM 2 SIDE YARDS 20 FEET 129'-5 1/2" NO
(FEET) CHANGE
MINIMUM LOT WIDTH (FEET) 75 FEET 183'-6" NO
CHANGE MINIMUM REAR YARD (FEET) 10 FEET 183'-10" NO
CHANGE
MINIMUM FRONT YARD 30 FEET 11'-8" NO
(FEET) CHANGE
MINIMUM EACH SIDE YARD 10 FEET 56'-4", 73'-1 1/2" NO
(FEET) CHANGE PRINCIPAL BLDG. 25% 2.3% NO
COVERAGE (PERCENT) CHANGE
MINIMUM 2 SIDE YARDS 20 FEET 129'-5 1/2" NO
(FEET) CHANGE MINIMUM LANDSCAPE 30% 77% 78%
COVERAGE (PERCENT)
MINIMUM REAR YARD (FEET) 10 FEET 183'-10" NO
CHANGE MAXIMUM BUILDING FLOOR 12,000 NO
4897.75 SQ. FT. CHA
AREA (SQ. FT.) NG E
PRINCIPAL BLDG. 65% 2.3% NO
COVERAGE (PERCENT) CHANGE NO
MAXIMUM HEIGHT (STORIES) 2 1/2 2 CHANGE
MINIMUM LANDSCAPE 50% 77% NO STORIES STORIES
COVERAGE (PERCENT) CHANGE
NO
NO MAXIMUM HEIGHT (FEET) 35 FEET 25 FEET CHANGE
MAXIMUM HEIGHT (STORIES) 2 1/2 2 CHANGE
STORIES STORIES
NO PARKING
MAXIMUM HEIGHT (FEET) 35 FEET 25 FEET CHANGE 2 SPACES/UNIT
MULTIFAMILY DWELING 2 UNITS 4 SPACES
4 SPACES REQ.
TOTAL 4 SPACES PROVIDED
OFFICES- (PROFESSIONAL) 1 PER 400 SQ. FT.
1,753.8 sq. ft.
5 SPACES
5 SPACES REQ.
TOTAL 5 SPACES PROVIDED
BUSINESS-(OFFICES) 1 PER 400 SQ. FT. 4 SPACES
(WILMAR ELECTRIC COMP.) 1,631.6 sq.ft.
4 SPACES REQ.
TOTAL 4 SPACES PROVIDED
ADDITIONAL SPACES 7 EXTRA SPACES
PROVIDED
18 SPACES
2 HC SPACE
TOTAL 20 SPACES PROVIDED
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
2
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM
PROPOSED CONDITIONS SITE PLAN CM-1201OR-SD
Page 120
STOCKPILE DETAIL
DETAIL SP
(AS NECESSARY)
CONSTRUCTION ENTRANCE
FILTER FABRIC DROP INLET
DETAIL CE
DETAIL FF
CONCRETE WASHOUT
DETAIL CW
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
SOIL EROSION AND SEDIMENT CONTROL EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
3
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
CORTLANDT MANOR, NY 10567
DETAIL
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC
9 DUNHILL DR.
SF ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM SOIL EROSION AND SEDIMENT CONTROL PLAN CM-1201OR-SD
Page 121
Tree Protection
fence: High density
polyethylene fencing
with 3.5" x 1.5"
openings; Color-
orange. Steel posts
installed at 8' o.c.
2" x 6' steel posts
or approved equal.
5" thick
layer of mulch.
Maintain existing
4'-0"
grade with the tree
protection fence
unless otherwise
indicated on the
plans.
SECTION VIEW
WATER SERVICE CONNECTION
DETAIL J
LIGHTPOST DETAIL
TREE PRESERVATION DETAIL DETAIL LP
SECTION TP
LIGHTPOST DETAIL
DETAIL LP
LK
WA
TE
RE
NC
CO
RB
CU
C.
CON
0"
3'-
TURF
DRIVEWAY CONCRETE APRON
ISOMETRIC VIEW
SECTION H
PAVEMENT RESTORATION DETAIL
SECTION B
EXTERIOR LIGHT SPECIFICATION
DETAIL LP
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
4
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM DETAILS CM-1201OR-SD
Page 122
REDI-ROCK
RETAINING WALL
ELEVATION RW
PROPOSED WALL - SECTION
REDI-ROCK RETAINING WALL PROPOSED ANGLED WALL - SECTION
REDI-ROCK RETAINING WALL
PROFILE
PROFILE
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
5
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM RETAINING WALL DETAILS CM-1201OR-SD
Page 123
WARNING: IT IS A VIOLATION OF NEW YORK ANDY CHEUNG, P.E. DRAWN BY: AC WILMAR ELECTRIC DRAWING NO.
EDUCATIONAL LAW, SECTION 7209.2, FOR ANY
AC ENGINEERING, PLLC
6
PERSON, UNLESS HE IS ACTING UNDER THE
DESIGNED BY: AC 1201 OREGON ROAD,
DIRECTION OF A LICENSED PROFESSIONAL CHECKED BY: AC CORTLANDT MANOR, NY 10567
9 DUNHILL DR.
ENGINEER OR LAND SURVEYOR, TO ALTER THIS APPROVED BY: AC SOMERS, NY 10589 SECTION 13.9 BLOCK 3 LOT 5
DOCUMENT IN ANY WAY. IF ALTERED, THE
ALTERING PERSON SHALL COMPLY WITH THE FEBRUARY 20, 2026
(914) 260-4239
HTTPS://ACENGINEERINGPLLC.COM
PROPOSED OFFICE RENOVATION PROJECT NO.
REQUIREMENTS OF NEW YORK EDUCATIONAL
LAW, SECTION 7209.2 N.Y.P.E. LIC. NO. 084461 DATE REV DATE DESCRIPTION DATE CREATED
EMAIL: ACHEUNG@ACENGINEERINGPLLC.COM RETAINING WALL CALCULATIONS CM-1201OR-SD
Page 124
Steven J. Basini, RA
February 1st, 2026
Steven Kessler, Chairman
Town of Cortlandt Planning Board
1 Heady Street
Cortlandt Manor, NY 10567
Re: 2329 Arlo Lane
Cortlandt Manor, NY
Auto Body Repair Shop
Site Plan Amendment
Mr. Kessler and Members of the Planning Board,
This office has received review memorandums pertaining to the above-referenced
application from the Department of Planning and Development and the Department of
Technical Services.
This memo shall address these comments in addition to the accompanying set of
drawings with Revision date 01/15/26. All revisions on the previously submitted plans have
been marked with a revision cloud. Two additional sheets have been created for this
submission, A-102 and A-103.
Memorandum from Department of Planning & Community Development
Dated November 21, 2025
Prepared by:
Chris Kehoe, AICP – Planning Director & Heather LaVarnway, CNU-A, AICP Planner
1. This application requires a special use permit for an automotive body shop. The
application has been updated on the portal to include this requirement. This
proposal meets the criteria for special use permit as described in Chapter 307
Section 307-62 of the Town Code and is outlined on the revised drawing A-101.
2. Parking has not changed. The proposal is 32 spaces where 44 are required. Section
307-29 of the Town of Cortlandt Code allows the Planning Board to consider a lesser
parking requirement under specific circumstances.
3. Turning radius and paths are shown on the proposed site plan, Sheet A-100. These
comply with requirements for emergency vehicles as well as sanitation trucks.
4. The existing building lighting is proposed to be maintained. There was a photometric
lighting plan approved in 2022 by the Town of Cortlandt that includes fully shielded
wall packs mounted on the façade of the building. These were installed, are
currently operational, and are not proposed to be altered or added to. There is no
site lighting existing or proposed. As outlined on sheet A-101, this application does
not require compliance with Chapter 307 of the Town Code as the cost of the project
does not exceed 50% of the value of the building.
5. The trash enclosure has been relocated to the rear of the building on the existing
18 Lakeview Avenue East • Cortlandt Manor, NY 10567 • (914) 402-1701 • sjbarchdesign.com
Page 125
concrete slab. This was agreed upon in a meeting with the Town’s consultants. A
detail of the previously approved enclosure has been shown on the revised plan A-
101 and located on the site plan, sheet A-101.
6. There is ample grass lawn in front of the building that will remain unaltered as part
of this application. These areas have been hatched with a grass pattern on the site
plan and noted as well. In addition, a small planting bed is proposed at the entrance
to the autobody shop. This is detailed on sheet A-103. There will be some plantings
proposed at the free-standing sign location as well. This is depicted on sheet A-101.
7. The only building elevation being altered is the front façade, southwest corner which
serves as the entrance to the proposed autobody shop. The existing and proposed
elevations are shown on sheet A-103. Since no other elevations are being altered,
the Town Code allows photographs of the existing elevations in lieu of drawings.
These have been included on sheet A-103 as well.
8. There is a free-standing sign proposed for the front yard. This is located on the
revised site plan, and a rendering is provided on Sheet A-100. As noted, the details
of this sign proposal shall meet the requirements of Chapter 245 of the Town Code
and will be presented before the Architectural Review Council.
Department of Technical Services
Dated December 8, 2025
Prepared by:
Catherine E. Brosnan, P.E. ENVSP
1. ADA compliant path from parking space to entrance is shown on the revised overall
site plan, Sheet A-100. The required maximum slope for accessible paths is 1/20 or
5%. The existing slope from the parking space to the entrance is 4.1%. The
concrete slab at the front entrance shall be poured with a 2% slope away from the
front entrance and shall be no greater than ½” below the door sill. A corrected NYS
ADA compliant parking sign has been depicted on revised sheet A-100.
2. Employee parking has been noted on the revised Site Plan, Sheet A-100 and is
located by the rear entrance to the building. 4 spaces are allocated for employees.
3. There shall be no autobody repair occurring outside the building. This is noted on
revised sheet A-100.
4. There shall be no salvaging or junking of vehicles on site. This is noted on revised
sheet A-100.
5. Existing and proposed floor plans have been provided on sheet A-102 along with a
complete code analysis of the uses. One as the previously approved S-1 storage use
and the other as the proposed mixed use.
6. Square footage of both spaces is shown on sheet A-102.
7. Topography has been shown on the overall site plan, sheet A-100. There are no cut
and fill calculations as no cutting is proposed. The small expansion of asphalt in the
rear of the building does not cut into a slope. It is merely clearing a small patch of
level overgrown grass. No retaining walls are proposed or required.
18 Lakeview Avenue East - Cortlandt Manor, NY 10567 - (914) 402-1701 - sjbarchdesign.com
Page 126
8. There are no existing or proposed floor drains in the building. This is noted on
revised sheet A-100.
9. This is a proposed autobody repair shop. It is not an auto mechanical repair shop
therefore draining of oil or fuel is not part of the proposed operation. However, if a
spill occurs, there is a waste disposal placement/pickup location shown at the rear of
the building on site plan, Sheet A-100.
10. See note #9 above. In the event of a spill, a spill prevention plan has been outlined
on the sheet A-101.
11. A photometric lighting analysis was approved by the Town in 2022. A copy of the
plan has been included with this latest submission. No existing lighting is being
altered, and no additional lighting is proposed at this time. All lights are currently
operating properly.
12. The proposed utility room has been depicted on the over key plan on revised sheet
A-101.
13. All references to outdated codes have been updated on the plans.
14. The existing septic system fields have been depicted on the site plan, revised sheet
A-100.
15. Potable and fire suppressant water lines have been depicted on the site plan, revised
sheet A-100.
16. The proposed location of the trash enclosure has been relocated to the rear of the
property as noted in comment #5 of the previous memo. This is detailed on revised
sheet A-101.
17. A rendering of the signage has been provided on revised sheet A-100.
18. It is understood that the paint booth will require approval by outside agencies other
than the Department of Technical Services. This will be filed upon complete review
by your Honorable Board.
19. A note has been added to sheet A-100 stating “All refuse pickup shall be by private
carter. The Town of Cortlandt will not service the site”.
Thank you for your consideration in this matter.
Sincerely,
SJB ARCHITECTURE + DESIGN
Steven J. Basini, RA
18 Lakeview Avenue East - Cortlandt Manor, NY 10567 - (914) 402-1701 - sjbarchdesign.com
Page 127
Steven J. Basini, RA
March 23, 2026
Steven Kessler, Chairman
Town of Cortlandt Planning Board
1 Heady Street, Cortlandt Manor, NY 10567
Re: 2329 Arlo Lane, Cortlandt Manor, NY
Auto Body Repair Shop, Site Plan Amendment
Mr. Kessler and Members of the Planning Board,
This office met with the Town of Cortlandt Department of Planning and Development
and the Department of Technical Services on March 11th to discuss the revised submission.
Several additional revisions were made to the drawing set as a result of those discussions.
They are as follows:
1. As part of the application, we must address the Special Permit for Parking as per
section 337-34.1 of the Zoning Code. Specifically, as the applicant is requesting a
waiver from the required number of spaces, we must indicate the category under
which relief is sought. There is a note at the bottom left of Sheet A-100 addressing
this Section of the code. The project narrative prepared by this office on October 21,
2025, and submitted to your Board prior to our first appearance, outlined the
reasons behind the waiver request.
2. An additional General Note was added to the bottom of Sheet A-100 describing the
specific emergency fire vehicles that were considered when depicting the required
turning radii on the plans.
3. The diameter of the existing domestic water line has been corrected to 2 inches.
4. The existing septic system shown on the plans has been labeled as “design
development” as they have not been confirmed in the field. Confirmation of the
exact locations of the utilities in relation to the septic system shall be documented
and submitted to the Department of Technical Services as part of the building permit
submission.
5. The free-standing signage depicted at the bottom of Sheet A-100 has been labeled
“Conceptual” as this will need to be filed separately and may change slightly in
appearance.
6. A note has been added on Sheet A-103 to the Front Entrance Plan stating that the
area of the entrance shall meet all ADA requirements upon removal of the existing
vestibule and reconstruction of the adjacent concrete slab.
Thank you for your consideration in this matter.
Sincerely,
SJB ARCHITECTURE + DESIGN
Steven J. Basini, RA
18 Lakeview Avenue East • Cortlandt Manor, NY 10567 • (914) 402-1701 • sjbarchdesign.com
Page 128
UNAUTHORIZED ALTERATIONS TO THIS
DRAWING IS A VIOLATION OF PART 69.5 (B)
EXISTING CURB CUT AND EGRESS OFF ARLO LANE TO EXISTING BUILDING AND PARKING ON SITE TO BE
PROJECT INFORMATION DATA: OF THE N.Y.S. EDUCATION LAW.
REMAIN UNCHANGED UNCHANGED AS PART OF THIS APPLICATION AND
UNAFFECTED BY THE PROPOSED CHANGE OF USE IN 1. MUNICIPALITY: TOWN OF CORTLANDT THIS PLAN IS NULL AND VOID UNLESS IT
ADJACENT BUILDING BEARS THE ORIGINAL SEAL AND SIGNATURE
2. TOWN TAX MAP DESIGNATION: SHEET: 34.6, BLOCK: 1, LOT 1 OF THE ARCHITECT.
3. TOTAL LOT AREA: 217,810 SF (5.0002 ACRES)
Drawn by: Checked by:
4. ZONING DISTRICT: MD ( DESIGNED INDUSTRIAL)
SJB SJB
SITE
LANE
5. OWNER: MARIC FAMILY LIM PARTNER / MARIC 1903 LLC
PARKING SPOT 19-53 46TH ST, ASTORIA, NY 11105
ELEV=328.3'
Project # Dwg. Date
ARLO
6. APPLICANT: MARIC FAMILY LIM PARTNER / MARIC 1903 LLC
BUILDING 19-53 46TH ST, ASTORIA, NY 11105
10/21/25
7. SITE PLAN PREPARED BY:
BEAR SJB ARCHITECTURE + DESIGN
MOU ENTRY FLR 18 LAKEVIEW AVE E, CORTLANDT MANOR, NY 10567
NTAIN ELEV=326.04' 1 Revisions
STAT
E PKWY ACCESSIBLE EGRESS PATH FROM PARKING 7. SITE LOCATION: 01/15/26 TOWN COMMENTS
1
TO ENTRANCE AT 4.1% SLOPE WHERE 2329 ARLO LANE
MAXIMUM IS 5% CORTLANDT MANOR, NY 10567 2 03/23/26 PB COMMENTS
3 -
8. SURVEY INFORMATION OBTAINED FROM SURVEY PREPARED BY:
CROMPOUND RD WARD CARPENTER ENGINEERS INC. -
76 MAMARONECK AVENUE
-
LOCATION MAP - NTS
WHITE PLAINS, NY 10601
DATED DECEMBER 23, 2020 -
OUTLINE OF PARKING -
MANEUVERING LANE AND
-
EMERGENCY APPARATUS
ACCESS ROAD
SPECIAL UNDERGROUND UTILITIES NOTE:
-
PRIOR TO ANY EXCAVATION ALL UNDERGROUND UTILITIES
MUST BE LOCATED. -
CALL 1-800-962-7962, CODE RULE #753, www.digsafelynewyork.com -
OVERALL SITE PLAN
1 SCALE - 1" = 60'-0" PARKING SIGNAGE 1
1. REMOVE "NO PARKING" SIGNS ALONG REAR OF
BUILDING.
4" FIRE SERVICE LINE
1 2. MAINTAIN EXISTING "NO PARKING" SIGNS ALONG
2" DOMESTIC WATER HILLSIDE AT SOUTH END OF BUILDING EXCEPT IN
1 PROPOSED FREE STANDING 2 SERVICE LINE AREA OF ACCESSIBLE PARKING SPACE
SIGN - SEE NOTE AND
RENDERING BELOW SAME 3. EMPLOYEE PARKING SPACES #8-11 AT REAR OF
PAGE BUILDING SHALL BE DELINEATED WITH SIGNS
GRASS LAWN AREA STATING "EMPLOYEE PARKING".
TO REMAIN
ACCESSIBLE 37 FT INSIDE TURNING RADIUS
PARKING EXCEEDS REQUIRED FOR GARBAGE
GRASS LAWN AREA
TRUCK AND FIRE TRUCK AT 60° TURNS
TO REMAIN 2
R3
7 1
AERIAL VIEW - NTS
'-0
18.0' typ. FIRE TRUCK TURNING
"
APPROXIMATE LOCATION OF EXISTING GRASS LAWN AREA CODE COMPLIANCE I CERTIFY THAT THESE DOCUMENTS WERE PREPARED
RADIUS PATH EXISTING VESTIBULE TO BE TO REMAIN OR APPROVED BY ME, AND THAT I AM A DULY
SEPTIC FIELDS - UTILITY AND SEPTIC ALL WORK SHALL CONFORM TO THE 2025 NYS UNIFORM
REMOVED LICENSED ARCHITECT UNDER THE LAWS OF N.Y.S.
9.0'
typ.
LOCATIONS SHOWN HERE ARE FOR BUILDING CODE, NFPA 17, NFPA 70 AND ALL OTHER
1 REGISTERED THROUGH JULY 31, 2026
1 DESIGN DEVELOPMENT ONLY - ACTUAL APPLICABLE MUNICIPAL, STATE, AND FEDERAL RULES AND
LOCATIONS TO BE VERIFIED IN FIELD REGULATIONS.
8'-0"
55.0' ACCESSIBLE PATH TO ENTRY PRIOR TO PERMITTING
2025 Fire Code of NYS (FCNY)
EXISTING SEPTIC TANK
SECTION 503 - Fire Apparatus Access Roads 1
503.1.1 Buildings and facilities R5
6.0
The fire apparatus access road shall extend to within 150 feet of all ' 32 25 26
22 23 24
portions of the facility. 2 21
Exceptions: The fire code official is authorized to increase the dimension 20.0' AREA OF BUILDING TO BE CONVERTED TO AUTO REPAIR AREA OF BUILDING TO REMAIN SELF STORAGE
of 150 if building is equipped throughout with an approved automatic PARKING SPACES INCLUDED
sprinkler system. WITHIN BUILDING 37 FT INSIDE TURNING RADIUS
20 FOOT FIRE 3 1 EXCEEDS REQUIRED FOR GARBAGE
503.2.1 Dimensions APPARATUS ACCESS TRUCK AND FIRE TRUCK AT 60° TURNS
R3
Fire apparatus access roads shall be an unobstructed width of not less ROAD ON SOUTH 31
7'-
than 20 feet. END OF BUILDING
0"
20 FOOT FIRE APPARATUS ACCESS
BEHIND PROPOSED 4
PROPOSED - 20 foot wide access road provided from street entrance to PARKING SPACES
ROAD ON NORTH END OF BUILDING
ACCESSED FROM LOADING DOCK
1
north and south ends of building. AREA 1
LANE BEHIND
Distance between ends of access roads along rear face of building is PARKING AND 5 27 28 29 Town of Cortlandt
FIRE TRUCK TURNING
220 feet. 220 / 2 = 110 feet (less than the 150 ft req'd. AROUND BUILDING 30 RADIUS PATH Special Permit Compliance for Automotive body shop
SHALL BE STRIPED R3
Building is proposed to be equipped throughout with an approved WITH 1-WAY 7'-
0"
6
automatic sprinkler system. ARROWS AS SHOWN 307-62 Automative body and paint shop
256.0 FT BETWEEN ACCESS ROADS - HALF DISTANCE 128.0 FEET - BELOW MAXIMUM PERMITTED 150.0 FT
1. Minimum distance from public and semipublic uses: 200 feet Client
Town of Cortlandt Zoning Code WASTE OIL & FUEL PICKUP
Proposed use is 425 ft measured horizontally from
7 LOCATION - IF NEEDED
1 closest public or semipublic use - Lakeland School
Article VIII - Off-Street Parking Requirements
20
district - Lincoln Titus Elementary School property.
MARIC FAMILY LP &
307-29 Table of Req'd Off-Street Parking Spaces
C. The Planning Board will fix the appropriate number of parking spaces
.0' 2. Minimum frontage 100 feet
Property Frontage in front of proposed use exceeds MARIC 1903 LLC
required for a particular use by considering the suggested standards 8* 9* 10* 11* 12 13 14 15 16 17 18 19 20 450 feet.
herein, as well as information provided by the applicant as to the 1
requirements of the use, as well as generally accepted standards of the 3. Surface Improvements
'
.0
planning and engineering professions. All driveways, parking and standing areas are paved
14
with asphalt or concrete.
14.0'
Required EXISTING WOOD DECK AND
4. No service aprons abut adjoining streets or highways and Project
Self Storage Facility - 1 / 10,000 SF of gross floor area & 1 per employee STEPS TO REMAIN
Area of Self Storage = 9,500 SF = 1 space
NEW 6 FT HIGH there shall be no dumping of waste materials, such as oil or
Employee - 1 per shift - 1 space
CHAIN LINK TRASH grease on site.
TOTAL REQUIRED - 2 spaces
ENCLOSURE - 20FT
X 9FT WITH 5. There shall be no motor vehicle sales on site.
Auto Collision
Auto Repair Service - 1 / 150 SF of gross floor area
1 LOCKABLE GATE Repair Shop
14 FOOT MANEUVERING AND PRIVACY
Area of Garage = 6,300 SF / 150 = 42 spaces
LANE ON EAST SIDE OF SLATS - SEE
TOTAL REQUIRED 42 spaces 14 FOOT MANEUVERING
BUILDING BEHIND * SPACES #8-11 SHALL TO BOTTOM OF GRASS SLOPE SHALL BE CLEARED TO SPECIFICATIONS
TOTAL REQUIRED FOR BUILDING - 44 SPACES PROPOSED PARKING 1 BE DESIGNATED EMPLOYEE
LANE ON EAST SIDE OF
ALLOW MINIMUM WIDTH OF MANEUVERING LANE AS SAME PAGE 2329 Arlo Lane
BUILDING BEHIND
SPACES PARKING - SEE PARKING PROPOSED SITE PLAN SHOWN - STABILIZE ADJACENT HILL AT MAX 1:2
Cortlandt Manor, NY 10567
MAXIMUM PRACTICABLE PROVIDED FOR BUILDING = 32 SPACES SIGNAGE NOTE BELOW 2 SCALE - 1" = 20'-0"
PROPOSED PARKING
SPACES
SLOPE AND PAVE AREA OF LANE WITH ASPHALT TO
MATCH EXISTING - VERIFY UTILITIES AS PER NOTE
307-33 Dimensions of parking spaces BELOW
1
Stall Width 9 feet - provided 9 feet 1 Dwg. Name
Stall Depth 18 feet - provided 18 feet
SIGNAGE AND LIGHTING GENERAL NOTES: SITE PLAN
Maneuvering Aisle Width
45° Angle of Parking - 1 Way - 14 feet - provided 14 feet
ADA PARKING GENERAL NOTES
1. THERE ARE NO EXISTING SITE LIGHTING FIXTURES AND NO ADDITIONAL SITE LIGHTING IS PROPOSED AT THE TIME OF THIS 1. NO AUTO BODY REPAIR SHALL OCCUR OUTSIDE OF THE BUILDING.
46° to 60° Angle of Parking - 1 Way 18 feet - provided 20 feet APPLICATION. SIGNAGE CODE COMPLIANCE
2. NO SALVAGING OR "JUNKING" OF VEHICLES SHALL OCCUR ONSITE. -
2. EXISTING FULLY SHIELDED WALL SCONCES AT EGRESS DOORS AND AROUND PERIMETER OF BUILDING TO BE REMAIN UNCHANGED.
307-34.1 SPECIAL PERMITS FOR PARKING ADA PARKING ONLY SIGN
2 SEE PREVIOUSLY APPROVED PHOTOMETRIC SITE LIGHTING PLAN INCLUDED WITH THIS APPLICATION.
3. NO FLOOR DRAINS EXIST WITHIN THE BUILDING THEREFORE NO OIL SEPARATORS ARE SHALL BE MOUNTED AT
C. Minimum standards for issuing a special permit parking for/parking: 3. PROJECT DOES REQUIRE COMPLIANCE WITH TOWN CODE CHAPTER 307 SECTION 307-12.3-B.2.b AS THE COST OF THE PROPOSED PROPOSED. END OF ACCESSIBLE
(1) The application shall indicate the category or categories of parking ALTERATION WILL NOT EXCEED 50% OF THE MARKET VALUE OF THE STRUCTURE. PARKING SPACE Sheet #
relief requested. 4. PROPOSED HOURS OF OPERATION - MO-FR 8AM TO 6PM - SAT-SUN 9AM TO 12PM. BETWEEN 5' & 7' ABOVE
4. SIGNAGE FOR PROPOSED AUTO-REPAIR BUSINESS SHALL BE FREESTANDING AS SHOWN ON THE SITE PLAN. SKETCH RENDERING OF THE GROUND MEASURED
SIGN IS SHOWN BELOW ON SAME PAGE. SIGNAGE SHALL CONFORM TO TOWN OF CORTLANDT CODE CHAPTER 245 AND SHALL BE
307-34.1 A(1) Waived parking - The applicant proposes to provide 32 5. ALL REFUSE PICKUP SHALL BE BY PRIVATE CHARTER. THE TOWN OF CORTLANDT WILL TO THE BOTTOM OF THE
PRESENTED FOR REVIEW BEFORE THE ARCHITECTURAL REVIEW COUNCIL.
A-100
parking spaces where 44 are required as calculated above. A waiver of NOT SERVICE THE SITE. SIGN.
28% (12 spaces) is requested. 5. FREESTANDING SIGN SHALL BE ILLUMINATED FROM GROUND LIGHTING ONLY DURING BUSINESS HOURS AND WILL AUTOMATICALLY
6. TURNING RADIUS SHOWN ON PLAN FOR FIRE TRUCKS EXCEED REQUIREMENTS FOR 30 FT
A reasoning for the requested waiver was provided in the narrative
TURN OFF BY 10PM EACH EVENING.
CONCEPTUAL PUMPER TRUCK (35 FT RADIUS) AND 35 FT RESCUE TRUCK (35 FT RADIUS)
2
prepared by this office on October 21st, 2025 and submitted to the PB FREE STANDING SIGNAGE RENDERING ACCESSIBLE PARKING SIGNAGE
and Town on October 27, 2025.
SCALE - NTS SCALE - NTS
Page 129
UNAUTHORIZED ALTERATIONS TO THIS
DRAWING IS A VIOLATION OF PART 69.5 (B)
OF THE N.Y.S. EDUCATION LAW.
THIS PLAN IS NULL AND VOID UNLESS IT
BEARS THE ORIGINAL SEAL AND SIGNATURE
OF THE ARCHITECT.
OIL TANK
Drawn by: Checked by:
SJB SJB
13'-9"
Project # Dwg. Date
PAINT BOOTH
10/21/25
37'-1112"
18'-1014"
16'-2" 7'-0"
UNALTERED EXISTING STORAGE USE Revisions
EQUIPMENT ROOM 1 01/15/26 TOWN COMMENTS
2 -
3 -
27'-0"
7'-0"
-
-
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
-
1
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
-
MECH.
ROOM -
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
-
-
-
OVERALL KEY PLAN TENANT SPACE BE ALTERED
ADA ACCESSIBILITY GUIDELINES 1 SCALE - 1/16" = 1'-0"
AS PER ICC/ANSI A117.1 2009
STORAGE
303.2 & 3 - Changes in Level. Changes in level up to 1/4 in (6.4mm) shall
be permitted to be vertical. Changes in level between 1/4 in and 1/2 in B
(6.4mm and 13mm) shall be beveled with a slope no greater than 1:2 .
A
30'-1"
5'-0" CLEAR 17'-3" 6'-10" 6'-1012" 6'-5" 19'-612"
309.4 Operation. Operable parts shall be operable with one hand and
shall not require tight grasping, pinching, or twisting of the wrist. The
force required to activate operable parts shall be 5.0 pounds maximum. 4'-6" CLEAR
4'-0"
606.4 Faucets. Faucets shall comply with 309.4 above. Hand-operated
5'
2'-6"
-0
4'-0" CLEAR
metering faucets shall remain open for 10 seconds minimum.
"C
5'-0" CLEAR
C
LE
606.6 Exposed Pipes and Surfaces. Water and drain pipes under ED
AR
lavatories and sinks shall be insulated or otherwise configured to protect U IR FT
AN
Q 0 PROPOSED EQUIPMENT
against contact. There shall be no sharp or abrasive surfaces under RE 37.
C
N DESIGNATION - SEE SPEC
E
IO = ACCESS TO
4'-8"
lavatories and sinks. "
1'-0"
SHEETS SAME PAGE BELOW
-0 RAT FT
4'-0"
'
1 A .0 STORAGE ABOVE
2'-0"
603.3 Mirrors. Mirrors shall be mounted with the bottom edge of the 11 SEP 11 I CERTIFY THAT THESE DOCUMENTS WERE PREPARED
1
reflecting surface 40 in maximum above the finish floor. N CE OF OR APPROVED BY ME, AND THAT I AM A DULY
A 3 T LICENSED ARCHITECT UNDER THE LAWS OF N.Y.S.
ST 1/ F
DI L - 9.0 REGISTERED THROUGH JULY 31, 2026
902.4 Height of work surfaces (for service sink counter) The tops of work IT L 7
EX ERA -
MAIN FLOOR
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
surfaces shall be 28 inches minimum and 34 inches maximum in height
above the floor. B .
IN V ED
M 3 O VID OFFICE
1/ RO
P
10'-112"
IBC SECTION 1209 - TOILET & BATHROOM
REQUIREMENTS
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
1209.2.1 - Floors and wall bases - Toilet room floor finish materials shall
have a smooth, hard, nonabsorbent surface. The intersections of such
2'-0"
5'
floors with walls shall have a smooth, hard nonabsorbent vertical base that
-0
"
BATH
C
4'-0"
LE
AR
extends upward onto the walls not less than 4 inches.
4'-8"
1'-0"
AN
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
C
E
5'
5'-0" CLEAR
-0
1209.2.2 - Walls and partitions. - Walls and partitions within 2 feet of BATH
"C
4'-0" CLEAR
service sinks, urinals and water closets shall have a smooth, hard,
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
LE
nonabsorbent surface, to a height of not less than 4 feet above the floor, B
AR
and except for structural elements, the materials used in such walls shall be 2'-6"
AN
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
of a type that is not adversely affected by moisture.
C
E
16'-6"
4'-0"
5'
-0
4'-6" CLEAR
"C
BATH
LE
RECEPTION
AR
AN
1
C
TOILET ROOM FINISH NOTES
E
5'-0" CLEAR
SEE SHEET A-103 FOR
Install 4"x4" white ceramic tile on all floor surfaces of toilet rooms with a
single 4"x4" tile return up the wall as a base. Grout and seal all joints to
ENTRANCE MODIFICATION Client
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
provide waterproof seal.
3 PROPOSED ADA COMPLIANT BATHROOMS
Bathrooms walls behind and adjacent to water closets shall receive 4"x4"
white ceramic tile to a minimum of 48" above finished floor surface. Grout
1 SCALE - 1/2" = 1'-0" MARIC FAMILY LP &
and seal all joints.
SPILL PREVENTION PLAN: PROPOSED AUTO REPAIR SHOP PLAN MARIC 1903 LLC
2 SCALE - 1/4" = 1'-0"
1. BUSINESS SHALL MAINTAIN VISIBLE ON-SITE SPILL KIT AT ALL TIMES CONTAINING THE FOLLOWING:
-- SPILL ABSORBENT SOCK OR BOOM CAPABLE OF 12 GALLON CAPACITY MINIMUM
-- GRANULAR ABSORBENT MATERIAL (IE. "QUICK'SORB") MINIMUM 20 LB PAIL
-- NITRIL GLOVES AND SAFETY GOGGLES
-- PUSH BROOM Project
2. PROCEDURE AS FOLLOWS:
--
--
STOP THE FLOW AT THE SOURCE
CONTAIN THE SPREAD USING THE BOOM AND GRANULAR ABSORBENT Auto Collision
-- CLEAN UP USING BROOM AND HAZARDOUS WASTE CONTAINER Repair Shop
2329 Arlo Lane
1 Cortlandt Manor, NY 10567
WATER CLOSET DETAIL ATLAS 8,000 LB CAPACITY 2 POST LIFT
SCALE : NTS
A N.T.S. Dwg. Name
PROPOSED
ALTERATION
FLOOR PLAN
-
FENCE SLAT DETAIL
SCALE - N.T.S. Sheet #
FENCE SLATS:
A-101
- Pexco Brand 6 ft X 1 inch Black HDPE
Fence Slats
- Shall be installed in each vertical line of
* TAKEN FROM PLAN PREVIOUSLY APPROVED BY THE openings from top to bottom rail along the ATLAS SLP-9K COMMERCIAL GRADE
PROPOSED TRASH ENCLOSURE* TOWN OF CORTLANDT - CREATED BY DESIGN length of the fence.
9,000 LB SCISSOR LIFT - (FULL RISE)
LAVATORY SECTION DETAIL 3 SCALE - NTS
DEVELOPMENT, PLLC 165 MAMARONECK AVE, FL. 2
WHITE PLAINS, NY 10601 - LAST REVISED 12/09/21 C
ATLAS BENCH RACK W/ SCISSOR LIFT
B
SCALE : NTS N.T.S. N.T.S.
Page 130
UNAUTHORIZED ALTERATIONS TO THIS
DRAWING IS A VIOLATION OF PART 69.5 (B)
OF THE N.Y.S. EDUCATION LAW.
PREVIOUSLY APPROVED PLAN FROM 2021 CURRENTLY PROPOSED MIXED USE PLAN THIS PLAN IS NULL AND VOID UNLESS IT
BEARS THE ORIGINAL SEAL AND SIGNATURE
OF THE ARCHITECT.
2025 BC OF NYS COMPLIANCE 2025 BC OF NYS COMPLIANCE
Drawn by: Checked by:
CHAPTER 3 - Use & Occupancy Classification CHAPTER 3 - Use & Occupancy Classification
SJB SJB
STORAGE Group 'S' STORAGE Group 'S'
Section 311.2 - Storage Group S-1 Section 311.2 - Storage Group S-1 MIXED USE
FACTORY Group 'F1'
CHAPTER 6 - Types of Construction
Section 306.2 - Moderate -hazard factory industrial Group F-1
STORAGE #2 USE- Project # Dwg. Date
GROSS FLOOR
Construction Type IIB 01/15/26
CHAPTER 6 - Types of Construction
Construction Type IIB
CHAPTER 9 - Fire Protection Systems AREA = 6,300 SF Revisions
CHAPTER 9 - Fire Protection Systems
FIRE SPRINKLER SYSTEM NOTES: 1 -
903.2.9 - Sprinkler system is required in a S1 - Storage Group FIRE SPRINKLER SYSTEM NOTES: 2 -
Use - System design was previously approved and is being 903.2.9 - Sprinkler system is required in a S1 - Storage Group
installed in entire building. 3 -
Use - System design was previously approved and is being
FIRE ALARM AND DETECTION SYSTEM NOTES: installed in entire building. -
907.2.10.1 Public and self storage ocupancies - No fire
FIRE ALARM AND DETECTION SYSTEM NOTES: -
alarm system is required for single story self storage use. 907.2.10.1 Public and self storage ocupancies - No fire -
alarm system is required for single story self storage use.
Smoke Detectors and Carbon Monoxide Detectors shall be -
installed in accordance to the 2025 BC OF NYS. 907.2.4 Group F - No fire alarm system is required for single
story F uses and those with combined occupany load less -
than 500.
-
CHAPTER 10 - Means of Egress
Smoke Detectors and Carbon Monoxide Detectors shall be
installed in accordance to the 2025 BC OF NYS.
STORAGE #1 USE- -
SECTION 100 - OCCUPANT LOAD
GROSS FLOOR -
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER
OCCUPANT
Storage areas - 300 gross
CHAPTER 10 - Means of Egress
AREA = 9,500 SF
15,800 SF Gross / 300 = 52 Occupants SECTION 100 - OCCUPANT LOAD
SECTION 1005 - MEANS OF EGRESS SIZING TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER
OCCUPANT
1005.3.2 Exception 1 - Other egress components = .15 inches Storage areas - 300 gross
width per occupant 9,500 SF Gross / 300 = 32 Occupants
52 occupants x .15 inches =7.8 inches
Existing front egress = 36" Auto Repair areas - (Industrial) - 100 gross
Existing rear egress = 36" 6,300 SF Gross / 100 = 63 Occupants
SECTION 1005 - MEANS OF EGRESS SIZING
1005.5 - Distribution of minimum width and required
capacity. 1005.3.2 Exception 1 - Other egress components = .15 inches
Where more than one exit, or access to more than one exit, width per occupant
is required, the means of egress shall be configured such * PLAN PREVIOUSLY APPROVED BY THE TOWN OF
that the loss of any one exit, or access to one exit, shall not PREVIOUSLY APPROVED BUILDING USAGE PLAN * CORTLANDT - CREATED BY DESIGN DEVELOPMENT, PLLC
reduce the available capacity or width to less than 50
Storage - 32 occupants x .15 inches = 4.8 inches
Existing front egress = 36" - Existing rear egress = 36"
1 SCALE - 3/8" = 1'-0"
165 MAMARONECK AVE, FL. 2 WHITE PLAINS, NY 10601
percent of the required capacity or width. - LAST REVISED 12/09/21
Auto repair - 63 occupants x .15 inches =9.5 inches
SECTION 1006 - EXIT ACCESS Existing front egress = 36" - Existing rear egress = 36"
I CERTIFY THAT THESE DOCUMENTS WERE PREPARED
1006.2.1 Egress based on occupant load and common path OR APPROVED BY ME, AND THAT I AM A DULY
1005.5 - Distribution of minimum width and required
of egress travel distance. LICENSED ARCHITECT UNDER THE LAWS OF N.Y.S.
capacity. REGISTERED THROUGH JULY 31, 2026
Two exits or exit access doorways from any space shall be Where more than one exit, or access to more than one exit,
provided where the design occupant load or the common is required, the means of egress shall be configured such
path of egress travel distance exceeds the values listed in that the loss of any one exit, or access to one exit, shall not
Table 1006.2.1. reduce the available capacity or width to less than 50
percent of the required capacity or width.
TABLE 1006.2.1
Max.Occupant Load for 'S' use = 29 w/ (1) EXIT SECTION 1006 - EXIT ACCESS
Max.Common Path of Egress Travel Distance with Sprinkler
System = 100 feet. 1006.2.1 Egress based on occupant load and common path
Proposed Occupant Load = 52 of egress travel distance.
MORE THAN ONE EXIT IS PROVIDED Two exits or exit access doorways from any space shall be
provided where the design occupant load or the common
path of egress travel distance exceeds the values listed in
CHAPTER 29 - Plumbing Systems Table 1006.2.1.
SECTION 2902 - MINIMUM PLUMBING FACILITIES TABLE 1006.2.1
Max.Occupant Load for 'S' use = 29 w/ (1) EXIT
TABLE 2902.1 Minimum Number of Required Plumbing Fixtures Max.Common Path of Egress Travel Distance with Sprinkler
Occupancy - "S" - Storage System = 100 feet.
Water closets & Lavatories - 1 per 100 occupants Proposed Occupant Load = 32
MORE THAN ONE EXIT IS PROVIDED
1 Water Closet / 1 Lavatory Required for occupancy of 52
Max.Occupant Load for 'F' use = 49 w/ (1) EXIT
(4) Toilet Rooms are proposed for Use Max.Common Path of Egress Travel Distance with Sprinkler
System = 100 feet.
2020 EBC of NYS COMPLIANCE Proposed Occupant Load = 63
STORAGE USE
MORE THAN ONE EXIT IS PROVIDED
EBC CHAPTER 6 - Classification of Work Client
SECTION 603 - ALTERATION LEVEL 2
CHAPTER 29 - Plumbing Systems
GROSS FLOOR
SECTION 2902 - MINIMUM PLUMBING FACILITIES
AREA = 9,500 SF MARIC FAMILY LP &
EBC CHAPTER 10 - Change in Occupancy TABLE 2902.1 Minimum Number of Required Plumbing Fixtures
Occupancy - "S" - Storage & "F" - Factory
MARIC 1903 LLC
Existing Use - B - Business
Proposed Use - B - Business - NO CHANGE
Water closets & Lavatories - 1 per 100 occupants for each Use
AUTOBODY USE
1 Water Closet / 1 Lavatory Required
Occupancy of 32 + 63 = 95 (less than 100) GROSS FLOOR
LIGHTING / ELECTRICAL NOTES:
Existing lighting fixtures to remain. Any modifications to or (4) Toilet Rooms are proposed for Use AREA = 6,300 SF Project
additions of electrical fixtures requires an electrical permit
and installation by a licensed electrician and shall comply 2025 EBC of NYS COMPLIANCE
with the 2020 BC OF NYS.
EBC CHAPTER 6 - Classification of Work
Auto Collision
Repair Shop
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
EMERGENCY LIGHTING AND EXIT SIGNS:
SECTION 603 - ALTERATION LEVEL 2
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
A licensed electrician shall provide all necessary emergency
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
egress lighting and illuminated exit signs to comply with
Chapter 10 - Section 1008 of the 2020 BC OF NYS.
EBC CHAPTER 10 - Change in Occupancy 2329 Arlo Lane
MECH. Cortlandt Manor, NY 10567
Existing Use - S1 - Storage
Proposed Uses S1 - Storage Use & F1 - Factory Use ROOM
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
Table 1011.5 Means of Egress Hazard Categories
S1 & F1 area same Relative Hazard Level 4 - No change in Dwg. Name
egress requirements.
Table 1011.7 Exposure of Exterior Walls Hazard Categories CHANGE OF
S1 & F1 area same Relative Hazard Level 2 - No change in OCCUPANCY
Fire Resistance Ratings required. PROPOSED BUILDING MISED USAGE PLAN COMPLIANCE NOTES
2 SCALE - 3/8" = 1'-0"
-
LIGHTING / ELECTRICAL NOTES:
Existing lighting fixtures to remain. Any modifications to or
additions of electrical fixtures requires an electrical permit Sheet #
and installation by a licensed electrician and shall comply
with the 2025 BC OF NYS.
EMERGENCY LIGHTING AND EXIT SIGNS:
A licensed electrician shall provide all necessary emergency
egress lighting and illuminated exit signs to comply with
Chapter 10 - Section 1008 of the 2020 BC OF NYS.
A-102
Page 131
UNAUTHORIZED ALTERATIONS TO THIS
DRAWING IS A VIOLATION OF PART 69.5 (B)
OF THE N.Y.S. EDUCATION LAW.
THIS PLAN IS NULL AND VOID UNLESS IT
EXISTING BUILDING EXTERIOR PICTURES BEARS THE ORIGINAL SEAL AND SIGNATURE
OF THE ARCHITECT.
Drawn by: Checked by:
MODELNUMBER
TRADENAME
PRODUCT
MATERIAL
SJB SJB
BATH
Project # Dwg. Date
01/15/26
Revisions
RECEPTION 1
2
-
03/23/26 PB COMMENTS
3 -
PROPOSED STOREFRONT WINDOW -
IN LARGER WALL OPENING
WEST FACADE -
-
-
-
PROPOSED PLANTINGS SHALL BE A MIXTURE
OF DWARF BOXWOODS (Buxus microphylla), -
ALTERED ENTRANCE SHALL LAVENDER (Lavandula angustifolia), BLACK-EYED
MEET ALL REQUIREMENTS SUSANS (Rudbeckia hirta) AND SEASONAL -
FOR ADA ACCESSIBILITY FLOWERING PLANTS SUCH AS MARIGOLDS -
(Tagetes erecta).
2
AREA OF ASPHALT CUT FOR PLANTING BED FLUSH WITH CURB
FLUSH STONE CURB
CONCRETE BELOW EXISTING
FOYER TO BE SAW CUT, EXISTING FOYER STRUCTURE REMOVED AND AREA
REMOVED AND REPOURED BELOW LEVELED WITH CONCRETE
LEVEL AND FLUSH W/
ADJACENT SURFACE EXISTING CONCRETE STRIP TO BE REPAIRED
EXISTING CONCRETE EXISTING ASPHALT PARKING AREA
PAVED AREA
SOUTH FACADE SOUTH EAST CORNER
PROPOSED FRONT ENTRANCE PLAN
1 SCALE - 1/4" = 1'-0"
I CERTIFY THAT THESE DOCUMENTS WERE PREPARED
EXISTING WINDOWS AND SIDING, COLOR, FINISHES OR APPROVED BY ME, AND THAT I AM A DULY
TO REMAIN UNCHANGED LICENSED ARCHITECT UNDER THE LAWS OF N.Y.S.
REGISTERED THROUGH JULY 31, 2026
EXISTING FULLY SHIELDED WALL PACK LIGHT
FIXTURES TO REMAIN (TYP.)
PROPOSED DOOR AWNING - 56"WIDE x 24" HIGH W/
36" PROJECTION - BLACK METAL SEAMED
PROPOSED STOREFRONT DOOR IN SAME OPENING
PROPOSED STOREFRONT WINDOW
IN LARGER WALL OPENING
SOUTHEAST FACADE NORTHEAST FACADE
23
PROPOSED PLANTINGS SHALL BE A MIXTURE
OF DWARF BOXWOODS (Buxus microphylla),
LAVENDER (Lavandula angustifolia), BLACK-EYED
SUSANS (Rudbeckia hirta) AND SEASONAL
FLOWERING PLANTS SUCH AS MARIGOLDS
(Tagetes erecta).
Client
EXISTING OVERHEAD DOOR AND
FACADE TO REMAIN UNCHANGED
PROPOSED FRONT ENTRANCE ELEVATION
MARIC FAMILY LP &
2 SCALE - 1/4" = 1'-0"
MARIC 1903 LLC
Project
NORTH FACADE NORTHEAST CORNER
Auto Collision
Repair Shop
EXISTING FOYER TO BE
REMOVED
2329 Arlo Lane
Cortlandt Manor, NY 10567
Dwg. Name
ELEVATIONS
ENTRANCE PLAN
EXISTING PICTURES
-
Sheet #
NORTHWEST CORNER SOUTHWEST FACADE
3
EXISTING FRONT ENTRANCE
SCALE - N.T.S.
A-103
Page 132
LIGHTING PHOTOMETRIC PLAN PREVIOUSLY APPROVED
BY THE TOWN OF CORTLANDT - CREATED BY DESIGN
DEVELOPEMENT, PLLC, 165 MAMARONECK AVE, FL. 2,
WHITE PLAINS, NY 10601 - LAST REVISED 02/15/22
INCLUDED IN THIS SET AS REFERENCE ONLY
Page 133
Page 134
Page 135
Page 136
Page 137
Page 138
Page 139
Page 140
Page 141
Page 142
Page 143
Page 144
Page 145
Page 146
Page 147
Page 148
Page 149
Page 150
Page 151
Page 152
Page 153
Page 154
Page 155
Page 156
Page 157
Page 158
Page 159
Page 160