Saturday, November 14, 2026Cortlandt, New YorkWeatherSearch
cortlandt.news
Local news · Reporting produced with AI
← Meeting record
Original source · agenda

Planning Board Meeting & Work Session — 2026-10-06 — Agenda

Open the Town’s original document ↗

Text below is an automated extract for searching and reading. Check the original for formatting, tables, diagrams and scanned pages. Captured text is not an editorial review.

Needs text review. The last captured version is retained.

Source provenance
Captured
October 27, 2026 at 9:14 PM Eastern
Original SHA-256
41da9fcba5b78a8f80c0450e3469344b17ad95a4f051539bd4a686c611367097
Format
PDF · 69 pages
Page 1 TOWN OF CORTLANDT PLANNING BOARD Steven Kessler, Chair Town Supervisor Thomas A. Bianchi, Vice-Chair Town Hall, 1 Heady Street Richard H. Becker, MD Cortlandt Manor, NY 10567 Nora Hildinger Main #: 914.734.1080 Town Board Kevin Kobasa Fax #: 914.788.0294 James F. Creighton Peter McKinley Cristin Jacoby Jeff Rothfeder Planning Staff email: Robert Mayes Karen Timko HeatherL@townofcortlandtny.gov Joyce C. White Kellan Cantrell, Alternate Planning Board Work Session & Meeting Tuesday October 6, 2026 To join the meeting remotely, use this Zoom link: https://us02web.zoom.us/j/86336571423?pwd=duUssFrQn1YYwbH8jQFXXjojQizmqe.1 WORK SESSION .... .................................................................................................................. 6:00 pm Discuss items on tonight’s Planning Board Meeting Agenda. MEETING AGENDA .............................................................................................................. 6:30* pm 1. Pledge of Allegiance 2. Roll Call 3. Changes to the Meeting Agenda, by majority vote 4. Adoption of the minutes from previous month 5. Old Business a. PB 2025-8: BEB Skyview Application of BEB Capital, LLC for the property of Skyview/Westview LLC and Eastview/Southview, LLC for Site Plan approval, a Residential Reuse Special Permit (RRUSP) and for Tree Removal and Steep Slope permits for a proposed 67-unit residential development located on E. Main St. (Route 6), Regina Avenue and Lexington Ave. Revised concept packet dated September 28, 2026. b. PB 2026-11: Evergreen Townhomes (Parcel 2) Application of VS Construction Corp for Preliminary Plat approval, Steep Slope, Wetland and Tree Removal permits to permit the construction of 96 townhomes on an approximately 17.6-acre portion of the Evergreen Manor project site. The subdivision proposes a 99-lot subdivision of the approximately 21-acre Parcel 2 of the Evergreen Manor Subdivision. The project is located within the Medical Oriented District on property located at 2003 Crompond Road. Drawings last revised August 19, 2026. Page 2 c. PB 2026-12: 44 Regina Ave | Cortlandt Self-Storage & Contractor’s Storage Area Application of Cronin Engineering on behalf of Cortlandt Self-Storage LP / Mark Giordano for an Amended Site Development Plan to construct one additional 8,000SF storage building and an outdoor contractor’s yard. Drawings last revised September 23, 2026. (see prior PB 11-96, PB 30-99, PB 3-06, PB 2021-17) d. PB 2024-4: Glamour Nails & Spa Application of John Lentini, R.A., for the property of J Glamour Nails & Spa, Inc., for Site Development Plan approval for the conversion of the former La Viletta Restaurant into a Nail Salon, on property located at 3172 East Main Street (Cortlandt Boulevard). Drawings last revised June 9, 2026. 6. New Business a. PB 2026-16: Hudson Valley Motorcycles | KRD Properties LLC Application of Cronin Engineering on behalf of KRD Properties LLC dba Hudson Valley Motorcycles for Amended Site Plan approval for the renovation of an existing 24,650 square foot former manufacturing facility into the new headquarters for Hudson Valley Motorcycles, to include two showrooms, service areas, and a parts department. The project is located in the HC-9A district at 2108 Albany Post Road. Drawings dated September 23, 2026. (see prior PB 221, PB 221 A-C, PB 54) 7. Adjournment Next Regular Meeting: THURSDAY November 5, 2026 at 6:30* PM Agenda information is also available at https://www.townofcortlandtny.gov/ * Regular meeting will begin at the conclusion of the work session, which could be prior to 6:30 pm. Page 3 SKYVIEW - TOWN OF CORTLANDT TOWN BOARD WORK SESSION 09/28/2026 Page 4 SKYVIEW 3275/3291 Lexington Avenue, 5 Skyview Road, 9/17/19 Regina Avenue, 3211/3219 East Main St. Cortlandt, New York Owner: BEB Capital 26 Harbor Park Drive Port Washington, NY 11050 Architect: 23 Washington Ave, Pleasantville, NY 10570 CIVIL Engineer: DTS Provident Design Engineering One North Broadway White Plains, NY 10601 SURVEYOR: Gallas Surveying Group, LLC 2865 US Route 1 North Brunswick, NJ 08902 ATTORNEY: Zarin & Steinmetz, LLP USE - MULTI-FAMILY USE - MULTI-FAMILY USE - SINGLE-FAMILY 81 Main Street, Suite 415 White Plains, NY 10601 Structural Engineer: MEP Engineer: LANDSCAPE Architect: CONSTRUCTION Manager Key Plan USE - DUPLEX USE - DUPLEX USE - SINGLE-FAMILY RRUSP CALCULATION Th These drawings d i are instruments i t t of service and Unit increase is limited to 20% more than existing are protected by copyright. These designs and drawings may not be reproduced or copied Existing Units = 58 without written permission from Gallin Beeler Design Studio, PLLC Calculation: 58 x 1.2 = 69.6 Units 05/06/25 PLANNING BOARD MEETING No. Date Description EXISTING BUILDINGS & USES - PROJECT SITE Project number 2329 Date 5/6/25 Drawn by KG 5/2/2025 12:40:20 PM Checked by RB G05 Scale N.T.S. Page 5 PROJECT INLET SKYVIEW 3211/3219 East Main Street 41 TC 411.12 4 GRT 410.56 INV UTO (TRAFFIC) ONLY INLET 9/17/19 Regina Avenue 41 2 TC 409.35 GRT 408.82 INV UTO (TRAFFIC) 5 Skyview Avenue 41 0 INLET 3275 Lexington Avenue GRT 410.96 40 (FWD)(NPV) 8 Town of Cortlandt, New York 406 404 402 FOR APPROVAL PURPOSES ONLY NOT APPROVED FOR CONSTRUCTION 400 ONLY 398 REET 396 INLET HIGH ST 394 TC 361.12 GRT 360.60 INV UTO (TRAFFIC) 392 410 420 B 390 A INLET A GRT 393.14 IN INV(A) 391.7 UE 430 0 INV(B) (FWD) 40 MA 388 T ET E AVEN 440 386 6 450 S E 384 EA TR 12" PIPE INV 382.1.1 382 S 380 460 415 0 12" PIPE 40 INV 379.2 410 " 12 HILLSID 378 376 78 374 470 12" PIPE 4.4 INV 374.4 420 372 390 NORTH 12" PIPE 370 .2 INV 372.2 368 0 40 INLET 366 TC 361.12 GRT 360.60 INLET INV UTO 364 GRT 358.73 (TRAFFIC) INV(A) 356.8 INV(B) 354.0 362 380 INV(C) UTO (REC) INV(D) 353.2 3@9' 28"± 360 358 C x 4" MH STORM 356 RIM 354.09 x A INV UTO (TRAFFIC) D 354 30" B 395 x 352 x 350 354 35 400 2 x 358 x 0 35 41 0 26" 348 x x INLET TC 355.73 GRT 355.26 359 (FWD)(NPV) 46 INLET 0 TC 359.56 C 440 450 GRT 359.05 INV(A) 357.0 B INV(B) 355.9 A INV(C) 355.7 " 470 ENUE 18 360 INLET AV TC 359.86 480 40 GRT 355.36 0 INV 323.0 EGINA DC ROA RE 390 362 410 DECATUR 700' LONG ROAD 15" 0 364 338 430 E 440 450 53 A APPROXIMATE 6 460 AVENU 470 REGIN 60 45 30 15 0 60 120 LIMIT OF 53 8 366 ROAD A DISTURBANCE 540 540 SCALE IN FEET 390 2 54 0 49 AVENUE Zarin & Steinmetz 8 538 4 36 54 SKY VIEW 480 Attorney 550 INLET 81 Main Street, Suite 415 GRT 368.18 546 INV 365.8 White Plains, New York 10601 370 8 54 560 0 INLET 50 GRT 369.13 x x (FWD)(NPV) x 54 0 Gallas Surveying Group, LLC NORTH Surveyor 2865 US Route 1 x North Brunswick, New Jersey 08902 54 18 2 BEDROOM UNITS 15" 2 x 54 x 4 HORTON 20 3 BEDROOM UNITS x 5@10' ROAD Gallin Beeler Design Studio 54 Architect INLET 6 GRT 369.28 INV 366.9 38 TOTAL UNITS 23 Washington Avenue 570 390 Pleasantville, NY 10570 400 410 548 380 550 510 0 52 0 54 SOUTH 0 55 15" 0 0 BEB Capital 57 56 Applicant Owner/ 26 Harbor Park Drive 16 2 BEDROOM UNITS Port Washington, New York 11050 368 N 15 3 BEDROOM UNITS LEXINGTO 15" AVENUE 460 470 450 NO. REVISION DATE 54 8 31 TOTAL UNITS 1 MODELED ADDITIONAL SLOPE RANGES 480 INLET 500 GRT 367.44 A 490 INV(A) 365.6 570 560 INV(B) 364.5 B 0 58 540 550 0 15" 6 51 54 530 520 590 4 TOTAL 54 34 2 BEDROOM UNITS 590 450 INLET 2 54 GRT 366.33 A CRAWFORD 370 440 INV(A) 364.4 430 420 380 35 3 BEDROOM UNITS 400 410 390 INV(B) 364.2 " 15 B 0 54 INLET A ROAD GRT 366.16 INV(A) 364.0 INV(B) 363.7 B APPROXIMATE 350' LONG 580 69 TOTAL UNITS LIMIT OF DISTURBANCE 57 0 538 Slopes Table DTS PROVIDENT ‹ NORTH 366 536 Appr From To Area (sf) 4@5' Number Color Civil Engineers, Landscape Architect and Planner AVENUE REGINA DTS Provident Design Engineering, LLP 0 208,953.31 56 534 1 0.00% 15.00% One North Broadway White Plains, NY 10601 532 2 15.00% 20.00% 119,559.57 DISTURBANCE AREA P: 914.428.0010 F: 914.428.0017 NORTH: 5.7 ACRES 15" 3 20.00% 25.00% 115,887.29 x x 530 © DTS Provident Design Engineering, LLP x 490 Certificate of Authorization #0017846 x 75,873.42 x 4 25.00% 30.00% SOUTH: 4.3 ACRES 500 380 528 480 470 370 8" x 550 UNDER NEW YORK STATE EDUCATION LAW ARTICLE 145 (ENGINEERING), 460 MH SEWER RIM 363.24 5 30.00% 35.00% 46,179.84 SECTION 7209 (2), IT IS A VIOLATION OF THIS LAW FOR ANY PERSON, UNLESS 450 x INV 358.8 526 ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO x 430 ALTER THIS DOCUMENT 420 440 6 35.00% 40.00% 40,769.91 x 524 540 NOTE: SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR 390 410 400 TOTAL: 10.0 ACRES x REPRESENTED BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF 522 7 40.00% 398.68% 69,998.36 DTS PROVIDENT DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED x AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED 36 4 PROJECT INDICATED HEREON AND SHALL NOT BE USED BY OR DISCLOSED TO x 520 5 ANY PERSON OR ENTITY WHATSOEVER WITHOUT THE WRITTEN PERMISSION 8"(C) LAWRENCE OF DTS PROVIDENT DESIGN ENGINEERING, LLP. x D x 3"(A) INLET B 12" 6"(B) 530 ROAD x TC 364.14 12" 518 WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER IMPERVIOUS AREA x GRT 363.47 A INV 360.8 B SCALED MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE INLET ROAD B FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT AND THIS OFFICE x TC 364.06 516 GRT 363.41 MUST BE NOTIFIED OF ANY DEVIATIONS OR VARIATIONS FROM DIMENSIONS 250' LONG INV(A) UTO (REC) AND CONDITIONS SHOWN BY THESE DRAWINGS. NORTH: 2.0 ACRES x INV(B) 360.7 INLET 514 540 x GRT 363.72 THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, x x INV(A) 361.6 364 INV(B) 361.4 DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH SURFACE 364 INV(C) 361.3 510 512 SOUTH: 1.7 ACRES ANYWHERE IN THE STATE TWO FULL-WORKING DAYS, EXCLUDING DAY OF x INV(D) 361.2 12" 0 52 CALL. CONTACT UDIG NY 811 OR 800-962-7962. FOR NEW YORK CITY AND 510 x x 52 0 LONG ISLAND, CONTACT 811 OR 800-272-4480 508 x 530 2@11' x 506 x 520 TITLE: TOTAL: 3.7 ACRES x 504 450 400 SLOPE ANALYSIS PLAN 440 0 480 490 420 364 460 50 470 430 0 410 502 8"(B) INLET GRT 365.81 INV(A) 364.7 C C 4"(A) 12" INLET GRT 375.89 500 498 2025 INV(B) 363.5 510 520 INV(C) 362.4 Seal 496 Scale: 1" = 60' 494 Date: 12/23/2025 366 0 50 Drawn By: JLM Checked By: RPP Project No.: 1085 Dwg. No.: C-800 Page 6 2026 PROPOSED PLAN Page 7 N.Y.S.P.C.S. (EA PROJECT 8 7 2.3 .43 5 6.7 EMERGENCY EGRESS SKYVIEW 7 9 39 7. 39 BC C39 396 NORTH DEVELOPMENT AREA - APARTMENT 7 T 40 02.3 40 3211/3219 East Main Street ONLY OR DRIVEWAY 7 BUILDINGS 9/17/19 Regina Avenue 394 4 2.3 05 WIDENED TO 24' FOR 5 Skyview Avenue 2. 39 2. .70 3 3275 Lexington Avenue 39 93 2.7 392 BC C3 39 ENTRY/EXIT 93 2 apartment buildings with first floor garage and 79 74 T 410 2. 3. Town of Cortlandt, New York 39 39 420 98 2. 39 390 10 8. 2 floors of apartments 7. .74 38 32 38 87 BC C3 43 T 8. IN 38 5 389.5+389.5 FOR APPROVAL PURPOSES ONLY 430 0 40 49 A 9. NOT APPROVED FOR CONSTRUCTION 388 77 38 50 8. .96 Unit Breakdown: M 5 3.9 5 38 3.5 .1 0 38 88 TC C3 9. 38 9.7 38 5 T ET TC C38 384 B B 0 .9 440 77 386 8 6 1BR x 4 floors = 24 1 BEDROOM (3 affordable) 38 4. 38 8.19 .67 450 S E 96 38 388 384 5. .43 38 85 EA TR TC C3 6 2BR x 4 floors = 24 2 BEDROOM (3 affordable) B 38 6. 05 APPROXIMATE 382 8 BUILDING SET BACK FROM 9.8 3 37 9.4 6 LIMIT OF S 0.1 8 Total: 48 UNITS (6 affordable) TC C37 B 38 38 0.7 5 TC C38 4 4.3 3 4.3 0 38 3.1 8 38 83.5 3 DISTURBANCE 380 4.3 9 EAST MAIN STREET WITH B 38 .38 84.0 460 4 3 415 0 38 40 4 5.9 6 37 5.5 5 4 6.4% ROOM FOR LANDSCAPING TC C37 410 6.3 0.5 1 81 B 38 0.5 0.8 Parking: 37 TC C38 B 38 38 0.7 GARAGE AT FIRST LEVEL ALONG MAIN STREET 0 378 6.7 9 376 37 25 spaces/building = 50 garage spaces 8 4 3.3 2 7 378 .07 BW 38 20' REDUCES IMPERVIOUS 374 7.9 39 470 4 2.0 6 37 7.3 7.9 9 37 1.5 TC C37 37 8.7 23 surface parking spaces TCC37 B 2.0 0 1 B 9 37 AREA AND REQUIRED 420 37 6.6 4 6.7 3 37 5.7 37 2.5 TC C37 372 37 B Total: 73 spaces = 1.5 space/unit 3 2.8 0 1 STORMWATER 390 37 .8 5.6 NORTH .21 TCC372 37 0 68 .82 TCC3367 B 9 37 6.3 +398 370 B 3.4 BW 1 37 398 36 8.3 36 8.6 1 8 MANAGEMENT 368 3.88 0 .35 37 4.85 40 64 .92 TCC3363 .62 37 B 69 .13 BW TCC3369 9 6.8% 366 1 B 9.7 4.4 36 9.14 36 36 4.7 5 36 BW 37 2.6 4 02 40 FLAT ROOF PROVIDES 364 393 .55 65 .09 TCC3365 9 +393 OPPORTUNITY FOR 362 B 5.6 22' 380 36 5.07 36 8.9 4 36 5.6 4 3@2' FOR GREEN ROOF OR 360 35 9 .13 9.4 61 .29 35 TCC3360 .80 B 3.7 4 22' 15' SOLAR 358 54 .34 36 TCC3354 BW B 8 .14 +390 220 LF 384+ 356 5.5 59 .62 35 TCC3358 + B 2 BW360.56 5.5 +390 354 35 N/F LANDS OF N/F LA LANDS OF 25' 395 .21 390 8 50 .77 TCC3349 SKYVIEW/WESTVIEW, LLC 412 SKYVIEW/WESTVIEW, /W LLC B 352 0.0 0 .26 CONTROLOL #402920502 3 35 53 .79 CONTROL #4402920495 357.5 TCC3352 B 350 3 3 BC358.6 5 0 TC359.1 7 9.8 2 364+ 358.0 BW359.7 34 4.4 35 .16 50 .68 BC 380+ 5% 7' 354 TCC3349 35 0 .84 400 TC3577.2 2 5 B .5 353 BW357.3 358 150 LF BC35 0 35 41 0 .3 351 357.0 22' 348 .4 346 0 359 .58 TC3599.0 BC35 3:1SLOPE 46 3 359.5 0 394 450 THIS DRAWING IS OF A PRELIMINARY NATURE AND IS + +394 440 0 SUBJECT TO REVISIONS BASED ON TOPOGRAPHIC AND .52 357.2 TC3599.1 26' BOUNDARY SURVEYS; SUBSURFACE SOIL CONDITIONS; BC35 402 4 ZONING ORDINANCES; AND REGULATORY APPROVALS 470 E VENU 401 360 BW360.10 APPROXIMATE LIMIT OF Zarin & Steinmetz +424 Attorney DISTURBANCE (TYP.) 81 Main Street, Suite 415 361.15 White Plains, New York 10601 361.03 360.32 359.7 480 40 361.32 AA 0 2.5% 402 361.38 10 S +420 REGIN 402 HP +402 4 pace Gallas Surveying Group, LLC SWM Surveyor 2865 US Route 1 3 North Brunswick, New Jersey 08902 +410 15 S 62.72 362.1 390 2.5% s 362.1 362 410 7 3 p 362.8 361.7 36 aces N/F LANDS OF 10 401 EASTVIEW/SOUTHVIEW Gallin Beeler Design Studio Architect 402 23 Washington Avenue REALTY 4 Pleasantville, NY 10570 363.2 CONTROL #410270093 364.03 26' 0 364 38 15' 430 BEB Capital 3 363.9 Applicant 362.8 364.68 Owner/ 26 Harbor Park Drive 440 Port Washington, New York 11050 365.02 450 460 REGIN 470 420 6 0 BC356.7 TC337.2 9% 4412 411 NO. REVISION DATE 365.84 366 1 366.5 3 A BW368.2 364.7 391 366.97 9% 390 +387 0 49 368.13 390 1 8 368.0 368.27 380 3 36 384 31' 480 384 384 410 DTS PROVIDENT ‹ 381 24' 8% ' N/F LANDS AND OF Civil Engineers, Landscape Architect and Planner C:\USERS\DMAIELLO\DC\ACCDOCS\DTSP\1085_SKYVIEW-WESTVIEW CORTLANDT\PROJECT FILES\SKETCHES\PRELIMINARYSITEPLAN ALT28I-L WITH TOPO 376 371.08 371 20 410+ SKYVIEW/WESTVIEW, /WES LLC DTS Provident Design Engineering, LLP 19' 370 370+370 One North Broadway White Plains, NY 10601 369.36 371.13 410 CONTROL ROL #402920502 371.62 390 +390 290 LF P: 914.428.0010 F: 914.428.0017 +436 369.17 436 © DTS Provident Design Engineering, LLP 390 Certificate of Authorization #0017846 N/F LANDS OF 404 UNDER NEW YORK STATE EDUCATION LAW ARTICLE 145 (ENGINEERING), EASTVIEW/SOUTHVIEW USE EXISTING 418 SECTION 7209 (2), IT IS A VIOLATION OF THIS LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO 0 REALTY 40 ALTER THIS DOCUMENT CONTROL #410270093 DRIVEWAY 0 4 NOTE: SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR 369.5 41 REPRESENTED BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED SWM WILL STILL HAVE SOME AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED LOCATION 369.66 PROJECT INDICATED HEREON AND SHALL NOT BE USED BY OR DISCLOSED TO 1 ANY PERSON OR ENTITY WHATSOEVER WITHOUT THE WRITTEN PERMISSION 369.3 0 OF DTS PROVIDENT DESIGN ENGINEERING, LLP. WALLS (3@9') BUT MINIMAL 42 9.73 (TOWN ROAD) N/F LANDS OF WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER 369 SCALED MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE 15 Spaces FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT AND THIS OFFICE EASTVIEW/SOUTHVIEW REALTY CONTROL #410270093 IN STEEP SLOPES MUST BE NOTIFIED OF ANY DEVIATIONS OR VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, 10 Spaces DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH SURFACE ANYWHERE IN THE STATE TWO FULL-WORKING DAYS, EXCLUDING DAY OF CALL. CONTACT UDIG NY 811 OR 800-962-7962. FOR NEW YORK CITY AND TURN OUT FOR FIRE TRUCK LONG ISLAND, CONTACT 811 OR 800-272-4480 369.43 372.7 TITLE: 367.6 NORTH SITE PLAN 369.51 368.89 390 ORIGINAL 400 2026 410 30' 380 30' LIMIT OF Seal Scale: 1"=60' DISTURBANCE Date: 5/18/2026 Drawn By: RPP 368.40 Checked By: RPP Project No.: 1085 96 3 Dwg. No.: SK-28 IL Page 8 r DEN ds " me ‘i . I GB APARTMENTS - AERIAL VIEW SEPTEMBER 28, 2026 > and Use a a (GALLIN BEELER Page 9 GB* DTS : PROvI DENT GB APARTMENTS - APPROACH SEPTEMBER 28, 2026 Intelligent Land Use ant aati eates Page 10 PROJECT 542. 54 2 SKYVIEW 541.19 75 3211/3219 East Main Street 542. 54 4 549.11 9/17/19 Regina Avenue 549.50 1 6.9 5 Skyview Avenue 54 3 3275 Lexington Avenue 54 5.1 54 6 548.97 2 4.3 54 Town of Cortlandt, New York 549.64 570 548 .83 550 FOR APPROVAL PURPOSES ONLY 510 546 0 52 5 2.4 NOT APPROVED FOR CONSTRUCTION 549.70 55 549.44 0 5 54 2.1 55 0 55 0 70 0 57 56 548. 548.80 549.20 549.33 548.82 TW550.29 BW548.77 548.37 549.20 SOUTH DEVELOPMENT AREA - 547.93 8 54 2 AND 3 BEDROOM TOWNHOMES 480 500 490 0 57 560 0 58 11 2 BEDROOM UNITS (2 affordable) BW545.90 545.51 546.15 540 550 0 6 51 54 530 520 8 3 BEDROOM UNITS (1 affordable) 590 19 TOTAL SUNITS OF (3 affordable) 543.38 VIEW, LLC 4 54 2920502 TW546.87 BW543.43 541.80 542.57 Parking: 590 2 54 538.25 2 sp/unit driveway parking = 38 spaces 538.17 0 54 BW542.25 539.88 537.92 5 visitor spaces = .25 spaces/unit 540.32 N/F LANDS OF BSI LEXINGTON AVENUE, LLC 580 CONTROL #510103519 539.23 APPROXIMATE 538 LIMIT OF 57 0 NORTH BW539.00 DISTURBANCE 536.24 9 535.8 NO DEVELOPMENT 535.87 536 HERE DUE TO BW538.00 0 56 534 STEEP GRADES THIS DRAWING IS OF A PRELIMINARY NATURE AND IS SUBJECT TO REVISIONS BASED ON TOPOGRAPHIC AND BOUNDARY SURVEYS; SUBSURFACE SOIL CONDITIONS; 532 ZONING ORDINANCES; AND REGULATORY APPROVALS 531.00 531.36 531.28 LEXINGTON Zarin & Steinmetz Attorney 530 81 Main Street, Suite 415 490 White Plains, New York 10601 +562 500 528 480 550 546 Gallas Surveying Group, LLC Surveyor 550 552 2865 US Route 1 +551 17' 548 9.72 16' 526 North Brunswick, New Jersey 08902 525.43 BW527.11 BW52 525.74 525.85 22' 54 549 SWM 50 550 552 1 551 54 546 8 548 524 540 +511 526 511 Gallin Beeler Design Studio 521.87 516 Architect 23 Washington Avenue 18' 24' 522 Pleasantville, NY 10570 520.68 20' 520.85 528 52 539 N/F LANDS O OF 3 536 53 517.07 518 5 540 541 2% 542 26' 520 8 EW/SOUTHVIEW REALTY, EW EASTVIEW/SOUTHVIEW R LLC 538 BEB Capital Applicant CONTROL #420800187 #42080 +518 Owner/ +519.5 518.8 26 Harbor Park Drive 20' 530 518.5 518. 24' 517.55 10' 519.5 9.5 10% 524.5 518 516.10 Port Washington, New York 11050 10% 24'-0" 5% 24' 6% 10% 540.1 +535 529.5 24' 24 516.35 513+513 +519.5 HP +544.5 0 516.90 537.6 53 535 4' 4 519.5 539.5 516 514.5 +529 5 529.5 539.5 544.5 NO. REVISION DATE 514 R2 540 20' 514 20' 504 4 20' 20' 5' 51 2% 517 18 51 518 524 5 4 26' SWM 512 510.25 0 510.83 539 511.00 528 8 535 535 0 7 52 24' 526 526 537 510 513 503 52 03 0 508 17 517 518 26' 530 26' 524 4 529 529 526 528 5 525 506 512 527 DTS PROVIDENT 502 +511 511 520 504 ‹ 501.96 480 490 50 502.50 0 Civil Engineers, Landscape Architect and Planner C:\USERS\DMAIELLO\DC\ACCDOCS\DTSP\1085_SKYVIEW-WESTVIEW CORTLANDT\PROJECT FILES\SKETCHES\PRELIMINARYSITEPLAN ALT28I-L WITH TOPO 502.76 502 DTS Provident Design Engineering, LLP 499.56 One North Broadway White Plains, NY 10601 ORIGINAL BW499.97 500 501.02 P: 914.428.0010 F: 914.428.0017 LIMIT OF BW498.8 8 498 TC49 © DTS Provident Design Engineering, LLP Certificate of Authorization #0017846 DISTURBANCE 520 510 BC49 8.20 7.86 497.26 UNDER NEW YORK STATE EDUCATION LAW ARTICLE 145 (ENGINEERING), 496 SECTION 7209 (2), IT IS A VIOLATION OF THIS LAW FOR ANY PERSON, UNLESS BW498.07 ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 493.15 493.33 493.05 494 NOTE: SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF DTS PROVIDENT DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED 0 50 PROJECT INDICATED HEREON AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON OR ENTITY WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF DTS PROVIDENT DESIGN ENGINEERING, LLP. WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT AND THIS OFFICE MUST BE NOTIFIED OF ANY DEVIATIONS OR VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH SURFACE ANYWHERE IN THE STATE TWO FULL-WORKING DAYS, EXCLUDING DAY OF CALL. CONTACT UDIG NY 811 OR 800-962-7962. FOR NEW YORK CITY AND LONG ISLAND, CONTACT 811 OR 800-272-4480 TITLE: SOUTH SITE PLAN 2026 Seal 1"=60' Scale: Date: 5/18/2026 Drawn By: RPP Checked By: RPP Project No.: 1085 Dwg. No.: SK-28 IL Page 11 GB* DTS + PROVIDENT GB TOWNHOUSE - EAST FACING SEPTEMBER 28, 2026 Intelligent Land Use an (GALLIN BEELER DEsioNSTUDIO Page 12 PROJECT NORTH DEVELOPMENT AREA - SKYVIEW 41 4.28 3.76 BC 41 2 APARTMENT BUILDINGS TC 3211/3219 East Main Street 3.93 41 4 41 TC 4.16 NORTH AND SOUTH 41 5.03 4.60 41 9/17/19 Regina Avenue BC 41 ONLY 5.16 9.99 41 41 BW 41 2 TW 5 Skyview Avenue DEVELOPMENT AREAS 41 0 3275 Lexington Avenue 24 9.48 TW 411. 1.88 0.07 40 BW 41 first floor garage and 2 floors of apartments 41 40 40 5.26 8 4.92 BC 40 Town of Cortlandt, New York TC 6.23 40 6.29 6.84 40 BC 40 TC 40 7.32 40 6.73 406 40 7.02 24 1 BEDROOM UNITS 404 Unit Breakdown: 39 0.30 9.90 BC 40 TC GS 402 FOR APPROVAL PURPOSES ONLY 35 2 BEDROOM UNITS G 1.18 65 40 2.33 2.37 87 0. 6 1BR x 4 floors = 24 1 BEDROOM (3 affordable) 1. 40 40 BC 40 NOT APPROVED FOR CONSTRUCTION N.Y.S.P.C.S. (EAST), NAD 83 TC 400 ONLY 40 5. 3 8 3 BEDROOM UNITS 39 6.0 57 398 6 2BR x 4 floors = 24 2 BEDROOM (3 affordable) BC 39 TC 19 6. 39 78 7.4 5 39 7.9 3 6. 39 BC 39 396 TC 7 .3 37 2 2. 40 Total: 48 UNITS (6 affordable) 67 TOTAL UNITS 40 37 394 2. 40 5 2.0 39 2.9.70 3 39 93 2.7 392 BC 3 39 3 9 TC 74 3.7 410 2.7 39 39 420 8 2.9 39 390 0 8.1 7.3.74 38 2 38 87 Parking: BC 3 TC 3 8.4 IN 38 DISTURBANCE AREA 430 389.5 0 40 49 MA T 9.4 388 7 38 0 8.7.96 9.5 5 8 95 3. 55 0 38 88 38 9.7 38 3. .1 TC C3 38 25 spaces/building = 50 garage spaces TC 38 384 B BC 0 T 8.9 440 7 386 E 38 4.7 38 8.119 .67 NORTH: 5.1 ACRES 450 S E 6 38 388 384 5.9.43 38 85 EA TR TC C3 5 B 6.0 38 23 surface parking spaces 382 88 9. 43 16 S 37 9. TC 37 BC 38 0. 0. 75 4. 38 3. 34 4 133 TC C33883 4. 38 38 3.50 388 38 SOUTH: 3.6 ACRES 380 38 BC 4. 09 38 38 4. 460 4. 38 415 0 338 40 5.9456 Total: 73 spaces = 1.5 space/unit 37 5. 54 410 TC 37 BC 6.35 0. 51 38 0. 81 37 TC C33880 38 0. BC TOTAL: 8.7 ACRES 38 0.79 378 6.70 376 37 8 3.34 07 38 7 378. BW 20' 374 7.9239 470 2.04 37 7. 7..997 37 1.56 TC 37 3777 8.79 TC 37 BC 37 BC 2.00 6.6174 6.79 420 37 7 37 5. 337 2.53 TC 37 3 372 37 BC 2.8380 5.61 390 37 2.80 NORTH 8.21 TC 37 3 37 TC36 7.82 BC 6.30 36 37 370 BC 33.49 BW 337 8.31 398 36 8.61 IMPERVIOUS AREA 368 36 3.88 0 40 4.35 37 4.85 TC36 3.92 37 BC 36 9.62 BW TC36 9.13 36 366 4.41 BC 9.79 36 36 99..1144 336 64 2 64 4.75 72. 402 36 W37 W3 BBW 364 393 TC36 5.55 36 5.09 NORTH: 1.4 ACRES 362 BC 5.69 22' 380 36 5.077 36 644 5..6 8.94 336665 360 35 9.49 1.13 35 TC36 0.29 36 22' 15' SOUTH: 1.1 ACRES BC 4 74 4.80 3..7 358 36 TC35 4.34 BW 35 BC 5.58 9.14 356 35 TC35 8.62 + 35 BC 5.52 BW360.56 354 35 N/F LANDS OF N/F LANDS F LA LAN A N OF 25' 395 390 8 TOTAL 2.5 ACRES 0.21 TC35 9.77 412 SKYVIEW/WESTVIEW, W/WE W/ LLC BC 34 SKYVIEW/WESTVIEW, LLC 352 0.00 3.26 CONTROL RO L # RO #402920502 357.53 35 TC35 35 2.79 CONTROL #4402920495 BC 350 BC358.63 TC359.13 358.00 9.85 BW359.77 34 4.42 35 0.16 9.68 BC 7' 354 TC35 35 TC3577.20 .84 34 400 2 BW357.35 BC 353.5 358 BC35 0 35 41 0 351.3 357.0 22' 348 346.4 TC3599.00 359 .58 BC35 359.53 46 0 394 440 450 TC3599.10 .52 357.2 26' BC35 402 APPROXIMATE 470 AVENUE 360 401 BW360.10 APPROXIMATE LIMIT OF DISTURBANCE (TYP.) LIMIT OF 361.15 361.03 360.32 359.7 480 40 361.32 0 361.38 402 DISTURBANCE GINA 402 SWM EG E RE 72 362.13 390 362.17362 410 362.83 62.7 362. 361.7 N/F LANDS OF 10 401 EASTVIEW/SOUTHVIEW 402 532.49 REALTY 363.24 CONTROL #410270093 3 534.4 9 534.1 6 534.7 364.03 0 26' 364 38 364 15' 430 363.93 362.8 364.68 440 365..02 02 450 53 6 460 36 470 6.85 420 76 BC356.76 0 TC337.20 53 412 411 THIS DRAWING IS OF A PRELIMINARY NATURE AND IS 7.79 53 53 6.9 53 365.84 8 0 53 366 SUBJECT TO REVISIONS BASED ON TOPOGRAPHIC AND 366.51 7.2 3 540 BW368.23 364.7 2 538.7 53 BOUNDARY SURVEYS; SUBSURFACE SOIL CONDITIONS; 2 391 7.50 538.9 540 539.69 ZONING ORDINANCES; AND REGULATORY APPROVALS 53 366.97 7. 69 390 53 2 3 7. 54 0 38 49 0 543.8 368.13 7 54 390 543.6 3. Zarin & Steinmetz 368.01 1 0 8 543.4 368.27 538 380 4 36 384 54 31' 480 Attorney 384 384 550 81 Main Street, Suite 415 545.2 410 538.8 24' 381 White Plains, New York 10601 538.1 N/F LA LANDS AND AN A DS OF D 546 376 ' 3 371 20 0 SKYVIEW/WESTVIEW, W/W/W WE W ES E ST S LLC 19' 371.08 546.3 .64 370 APPROXIMATE 7 370 371.13 547.7 369.36 547 410 CONTROL TR T RO ROOLL##402920502 .33 371.62 547 390 369.17 539.81 8 2025 LIMIT OF 6 54 436 539.08 390 N/F LANDS OF 404 560 0 EASTVIEW/SOUTHVIEW 50 418 DISTURBANCE Gallas Surveying Group, LLC 0 REALTY 549.13 40 0 547.6 Surveyor 54 549.05 CONTROL #410270093 540.46 549.38 540.92 0 369.54 2865 US Route 1 41 SWM North Brunswick, New Jersey 08902 369.66 541.52 369.31 0 42 .79 369.73 54 540.60 542 N/F LANDS OF 2 541.19 EASTVIEW/SOUTHVIEW REALTY .75 CONTROL #410270093 542 54 540.64 4 549.11 549.50 6.91 54 Gallin Beeler Design Studio 369.43 372.7 54 Architect 5.13 6 54 548.97 4.32 23 Washington Avenue 367.6 54 549.64 369.51 368.89 570 Pleasantville, NY 10570 390 400 410 548 380 3 546.8 550 510 0 52 45 2. 549.70 55 549.44 0 5 54 2.1 55 368.40 0 55 0 BEB Capital 548.70 0 57 56 Applicant Owner/ 26 Harbor Park Drive 367.96 368.33 370.6 Port Washington, New York 11050 548.80 549.20 368.40 368 549.33 548.82 TW550.29 BW548.77 365.8 548.37 549.20 460 470 450 547.93 NO. REVISION DATE 370.7 8 367.53 367.53 54 BW368.70 367.05 480 500 490 570 560 0 58 BW368.34 BW545.90 365.0 545.51 546.15 540 550 0 6 51 54 530 520 367.08 590 367.32 366.58 BW368.27 N/F LANDS OF 543.38 SKYVIEW/WESTVIEW, LLC 4 54 CONTROL #402920502 368.21 TW546.87 BW543.43 364.4 366.82 366.27 541.80 542.57 590 450 2 54 538.25 370 440 430 366.27 420 380 400 366.73 410 390 538.17 0 BC366.18 TC366.42 54 BW542.25 539.88 537.92 366.55 540.32 N/F LANDS OF APPROXIMATE BSI LEXINGTON AVENUE, LLC APPROXIMATE 366.59 580 CONTROL #510103519 364.9 539.23 2025 LIMIT OF LIMIT OF 538 DTS PROVIDENT ‹ 366.32 0 57 Slopes Table NORTH 366.36 DISTURBANCE 364.5 DISTURBANCE BW539.00 366 536.24 535.89 535.87 BC365.38 TC365.53 536 Number From To Color Area (sf) Civil Engineers, Landscape Architect and Planner C:\USERS\DMAIELLO\DC\ACCDOCS\DTSP\1085_SKYVIEW-WESTVIEW CORTLANDT\PROJECT FILES\SKETCHES\PRELIMINARYSITEPLAN ALT28I-L WITH TOPO 365.96 365.94 DTS Provident Design Engineering, LLP BW538.00 0 208,953.31 BC365.25 56 TC365.25 364.5 534 1 0.00% 15.00% One North Broadway White Plains, NY 10601 36 9.15 P: 914.428.0010 2 15.00% 20.00% 119,559.57 SOUTH DEVELOPMENT AREA - 532 F: 914.428.0017 365.99 531.00 531.36 531.28 370.71 363.6 3 20.00% 25.00% 115,887.29 © DTS Provident Design Engineering, LLP BC364.74 BC365.59 TC364.95 TC365.78 530 2 AND 3 BEDROOM 490 Certificate of Authorization #0017846 365.02 4 25.00% 30.00% 75,873.42 366.7 363.0 500 380 528 480 470 370 550 UNDER NEW YORK STATE EDUCATION LAW ARTICLE 145 (ENGINEERING), 460 BC365.38 TC365.53 BC365.25 TC365.25 TOWNHOMES 364.32 46,179.84 SECTION 7209 (2), IT IS A VIOLATION OF THIS LAW FOR ANY PERSON, UNLESS 546 5 30.00% 35.00% 450 550 363.0 552 364.9 17' 548 ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO BW529.72 16' 526 525.43 ALTER THIS DOCUMENT 525.74 525.85 22' 430 420 440 549 SWM 550 546 6 35.00% 40.00% 40,769.91 BW527.11 552 551 27.. 364.22 527 548 524 NOTE: SITE DESIGN CONCEPTS AND INFORMATION INDICATED OR 540 390 410 BC365.22 TC365.65 TC366.46 400 BC365.94 REPRESENTED BY THIS DRAWING ARE OWNED BY AND ARE THE PROPERTY OF 363.95 526 511 521.87 516 7 40.00% 398.68% 69,998.36 DTS PROVIDENT DESIGN ENGINEERING, LLP. THIS DRAWING WAS CREATED 18' 24' 522 AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED 20. 8 520.68 36 20' BC363.75 BC365.79 TC364.26 TC364.30 520.85 11 2 BEDROOM UNITS (2 aff.) 4 PROJECT INDICATED HEREON AND SHALL NOT BE USED BY OR DISCLOSED TO 528 539 TC366.73 N/F LANDS OF 536 517.07 ANY PERSON OR ENTITY WHATSOEVER WITHOUT THE WRITTEN PERMISSION 518 540 BC363.70 TC364.33 BC366.31 541 520 542 26' EASTVIEW/SOUTHVIEW REALTY, LLC 538 OF DTS PROVIDENT DESIGN ENGINEERING, LLP. 362.9 CONTROL #420800187 518.8 20' 530 518.5 8 3 BEDROOM UNITS (1 aff.) 24' 517.55 10' 519.5 518 WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER 364.00 524.5 516.10 365.34 376.27 SCALED MEASUREMENTS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT AND THIS OFFICE 24' 540.1 529.5 DS365.95 24' 516.35 90 516.90 6.3 513 535 6. 514.5 519.5 544.5 539.5 537.6 516 MUST BE NOTIFIED OF ANY DEVIATIONS OR VARIATIONS FROM DIMENSIONS DS377.01 19 TOTAL UNITS (3 affordable) 5 539.5 5 529.5 AND CONDITIONS SHOWN BY THESE DRAWINGS. BC363.85 TC364.49 363.69 365.03 514 R2 540 20' 514 THE STATE OF NEW YORK REQUIRES NOTIFICATION BY EXCAVATORS, 20' 504 364.02 20' 364 20' 5' DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH SURFACE 364 510 517 518 524 26' SWM 512 ANYWHERE IN THE STATE TWO FULL-WORKING DAYS, EXCLUDING DAY OF 25 510.25 510.83 539 511.00 528 365.46 535 0 537 52 CALL. CONTACT UDIG NY 811 OR 800-962-7962. FOR NEW YORK CITY AND BC364.44 526 TC364.79 24' DS376.98 376.46 DS365.98 510 LONG ISLAND, CONTACT 811 OR 800-272-4480 513 503 363.9 52 0 Parking: 508 517 518 26' 530 8 26' 524 529 TC362.2 6 526 528 525 506 BC361.7 TITLE: 512 527 502 364.78 364.60 511 520 364.56 365.50 2 sp/unit driveway/garage parking CONCEPTUAL ALTERNATIVE PLAN 504 501.96 450 400 440 480 490 420 364 460 50 502.50 470 430 0 DS365.97 410 502.76 DS377.04 TC362.99 BC362.5 6 502 499.56 501.02 2026 376.15 364.1 = 38 spaces BW499.97 500 366.03 BC364.91 TC366.45 365.30 BW498.88 498 TC498.20 BC497.8 510 520 6 Seal 1"=60' 365.21 497.26 DS367.35 Scale: 5 visitor spaces = .25 spaces/unit 496 GF367.34 BW498.07 493.15 493.33 Date: 5/18/2026 493.05 494 366 0 GF367.30 Total: 44 spaces = 2.25 sp/unit BC365.62 TC366.16 50 365.75 365.87 367.30 Drawn By: RPP 364.5 DS367.34 Checked By: RPP Project No.: 1085 Dwg. No.: SK-1 Page 13 EET PLAYGROUND STR IN T MA S EA APARTMENT BUILDINGS REGIN A RETAINING WALLS STORMWATER MANAGEMENT WOODED AREA LEXINGTO STORMWATER MANAGEMENT DOWNHILL UNITS UPHILL UNITS N AVE ONGRADE UNITS PLAYGROUND SITE PLAN - RENDERED SEPTEMBER 28, 2026 Page 14 TO: Town of Cortlandt Planning Board FROM: Christopher Lapine, PE, LaBella Associates, DPC DATE: September 10, 2026 RE: PB2026-12 - 44 Regina Avenue – Site Development Plans Self Storage LaBella has performed a review of the submittal for “Site Development Plan For Cortlandt Self Storage, LP’” located at 44 Regina Avenue, Cortlandt Manor, New York. The following documents were submitted for our review: • Site Development Plan – Site Development Plan For Cortlandt Self Storage, L.P., prepared by Cronin Engineering, last revised 8/19/26 (5 Sheets) Our office offers the following comments: Administrative 1. LaBella performed a cursory review of the current site conditions to identify discrepancies between the adopted Resolution No.1-07, dated January 11, 2007 and approved Sheet 1 of 1 titled Site Plan of Additional Buildings – Cortlandt Self Storage Complex at Regina Avenue dated January 25, 2006 and last revised January 15, 2008, as prepared by Ralph Mastromonaco for the development plan. The following were noted: a. Access drive to the rear of buildings 6 and 7 (formerly identified as 1 and 2 on approved plan) was added. b. Multiple retaining walls were constructed to support the rear access drives to buildings 6 and 7 (formerly identified as 1 and 2 on approved master development plan). c. Parking was added to the southwest corner of building 6 (formerly identified as building 2 on the approved master development plan). d. Parking has been added to the west and south of building 5 (formerly identified as building E on the approved master development plan). e. Trailer storage in rear of building 8 (formerly identified as building E on the approved master development plan). f. Building 8 (formerly identified as building 3 on the approved master development plan) was shifted south from the original location. These items should be referenced For Planning Board consideration as part of the site plan approval for the new building. Page 15 Page 2 2. Provide a removals plans identifying asphalt, structures, and utilities to be removed. 3. Provide retaining walls calculations for sliding, overturning, and global stability for constructed walls over 3-ft on-site. Provide details for the associated site improvements. 4. ALL approvals must be received by regulatory agencies having jurisdiction prior to commencement of ANY construction activities. 5. Per Chapter 259, a steep slope analysis and finding statement may be required. 6. Per Chapter 179, a wetland finding statement may be required. 7. Firematic response comments are pending referral to DOTS – Code Enforcement and the Lake Mohegan Fire Department upon revision of the plans. These items should be noted in the proposed Site Development Plans and include an updated drainage analysis for the site. Sheet SP-1.1 – Site Development Plan 1. Extend the water line easement to encompass the hydrant near building 9. 2. Provide a dimensional bulk table for the site, legend, and Town Signature Block on the plans. 3. Note the previous site changes to the site. 4. Number all buildings. Sheet SP-1.2 - Site Development Plan 1. The Planning Board Chairman requested physical barrier (i.e. fence) around the contractor yard area. 2. Clarify the necessity of 623 sf of asphalt and retaining wall shown to the north of the new building It appears a majority of the retaining wall and proposed asphalt (623 sf) to the north of the new building can be removed and a single 5-foot-wide access to the doors can be provided. 3. Identify points of door access to the proposed facility. 4. Provide a note on the plan indicating no exterior equipment storage or container storage is permitted outside of the areas designated as contractor storage and no outdoor repair of equipment is permitted. 5. Show relocated sanitary force main, drainage pipe, and drainage structures, footing drains, as well as proposed drainage infrastructure (including roof leaders and means of conveyance). 6. Provide a note on the plan that sanitary sewer force main and drainage piping to be relocated prior to building construction. Also note, sanitary force main is to be pressure tested following relocation in the presence of a Town of Cortlandt Department of Technical Services Representative and Applicant’s Engineer. A Professional Engineer shall provide a certification of said installation and testing to the Town. 7. Provide additional capacity for the increase in impervious areas within the stormwater management basin compared to the original site plan. Note the basin shall be restabilized with topsoil, seed, and mulch. 8. Please confirm if the area of total disturbance associated with the additional improvements identified in Administrative Comment 1 and the proposed project exceed the one acre threshold and thus require a SWPPP under the NYSDEC Redevelopment criteria. 9. Sheet SP1.1 indicates material storage on-site but is not shown on Sheet SP-1.2. Material storage areas shall be shown along with mechanism of containment to prevent sediment runoff. 10. Show not only spot elevations but proposed contours around the building. 11. Provide new invert at drop inlet with rim 328.9 receiving the new 15-inch drainage pipe. 12. It appears a low point is being created on the southern side of the building, and a catch basin will be required. 13. Identify the surface area of the storage yards. Page 16 Page 3 14. Number all buildings. 15. Add a note indicating the conservation easement shall be field staked by a NYS licensed surveyor prior to Building Permit Issuance. At no point shall the conservation easement be encroached upon. 16. The contractor’s yard extends over the drainage easement. If outdoor storage is permitted over the drainage easement it shall either be relocated elsewhere onsite, or sufficient notes outlining access and responsibility to relocate of the outdoor storage. 17. Provide a safety plan on how equipment moves from one side of the site to the other without interfering with the customers accessing the storage buildings. 18. List the exact equipment proposed to be onsite in the contractor’s yard. 19. Clearly indicate employee vs customer parking. 20. Consider eliminating door locations on Sheet FP-3.1 and Sheet FP-3.2 in the front and rear of the building to eliminate the needs for stairs in the rear and retaining wall and ramp in the front. Otherwise show the necessary improvements for Planning Board review and consideration. 21. As indicated at the September Planning Board meeting, please add a note that no storage of aggregate material will take place within the contractor storage area. 22. Add the following Town Standard notes: a) All disturbed areas shall be 100% stabilized and planted prior to the issuance of a Certificate of Occupancy. b) The applicant shall submit an as-built foundation survey to the Town of Cortlandt prior to framing c) Prior to the backfilling of any storm water best management practice, DOTS shall be notified to perform an inspection. d) All proposed import fill must be tested and certified as unrestricted, suitable for residential use in accordance with Town Policy. Certification must be provided by a licensed professional. All certifications shall be addressed to Town’s Planning Board Engineer. All soil analytics and reports will be forwarded to the Town’s Planning Board Engineer for review and approval. e) Prior to acceptance of the road and drainage facilities, the Town will require a certification from a NYS Engineer that the completed site work and drainage improvements will not cause an adverse impact to adjoining or downstream properties. f) Rock ripping will be used wherever possible. If blasting is required, it will require prior approval from the Town of Cortlandt and an air quality permit from the Westchester County Department of Health. g) There shall no processing of excavated materials by a rock crusher or similar equipment on- site. h) No retaining wall or foundation drains shall be discharged into the on-site drainage system. Sheet CD-2.1 – Construction Details 1. Multiple details for sewer installation beneath pavement are provided. Select one and remove the others. 2. Driveway asphalt section differs from trench replacement details. Please clarify and provide consistent asphalt sections. Page 17 From: Michelle Robbins To: Heather LaVarnway Subject: Fw: 44 Regina Avenue – Fire Department Review Date: Saturday, September 19, 2026 8:07:47 AM Fyi... Sent from my Verizon, Samsung Galaxy smartphone Get Outlook for Android From: Thomas Eade <t > Sent: Friday, September 18, 2026 10:41:59 AM To: Michelle Robbins > Subject: 44 Regina Avenue – Fire Department Review CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Good morning, Michelle, I met with the property owner, Mark Giordano, on September 17th to review the proposed project at 44 Regina Avenue from the Fire Department’s perspective. Based upon my site visit and discussion with Mr. Giordano, I have no comments or concerns regarding the proposed amended site plan. During the site visit, I asked Mr. Giordano to provide additional identification in the diesel tank area and to clearly identify the building numbers at the respective buildings. He has since provided me with a current subdivision map identifying the building numbers and confirmed that the requested signage will be installed. Please let me know if you need anything further from the Fire Department. Thank you, Thomas Eade Lake Mohegan Fire District Fire Chief PO Box 249 Mohegan Lake, NY 10547 *CONFIDENTIALITY NOTE* Page 18 The information contained in this E-mail is confidential and is privileged and exempt from disclosure. It is intended only for the use of the individual(s) or entity(ies) named in the body of the message above. If the reader of this message is not the intended recipient, you are prohibited from any dissemination, distribution, printing or copying of this E-mail. If you have received this E-mail in error, please immediately notify us by telephone (914)528-1808 and please destroy all copies and attachments. Thank you. From: Michelle Robbins < i Sent: Friday, September 4, 2026 1:55 PM To: Michelle Robbins < > Subject: Lead Agency Circulation Notice of Intent for 44 Regina Avenue Town of Cortlandt Attached please find a Lead Agency Notice of Intent for 44 Regina Avenue, Cortlandt Manor, NY. The proposed project is an amended site plan for a self-storage facility and contractor’s storage yard. Page 19 KATHY HOCHUL KATHY MOSER Governor Commissioner September 21, 2026 Heather LaVarnway Planner Town of Cortlandt Planning Dept 1 Heady St Cortlandt Manor, NY 10567 Re: DEC 44 Regina Ave - Cortlandt Self-Storage 44 Regina Ave, Mohegan Lake, NY 10547 26PR07404 Dear Heather LaVarnway: Thank you for requesting the comments of the Office of Parks, Recreation and Historic Preservation (OPRHP). We have reviewed the project in accordance with the New York State Historic Preservation Act of 1980 (Section 14.09 of the New York Parks, Recreation and Historic Preservation Law). These comments are those of the OPRHP and relate only to Historic/Cultural resources. They do not include potential environmental impacts to New York State Parkland that may be involved in or near your project. Based upon this review, it is the opinion of OPRHP that no properties, including archaeological and/or historic resources, listed in or eligible for the New York State and National Registers of Historic Places will be impacted by this project. If further correspondence is required regarding this project, please be sure to refer to the OPRHP Project Review (PR) number noted above. If you have any questions, please contact Olivia Holland at the following email address: Sincerely, R. Daniel Mackay Deputy Commissioner for Historic Preservation Division for Historic Preservation New York State Office of Parks, Recreation and Historic Preservation Division for Historic Preservation, Peebles Island, PO Box 189, Waterford, New York 12188-0189 Page 20 ET AMENDED RE ST IN MA ST EA SITE DEVELOPMENT PLAN CORTLANDT CORTLANDT FOR CORTLANDT SELF-STORAGE TOWN OF CORTLANDT SITE WESTCHESTER COUNTY, NEW YORK CORTLANDT CORTLANDT GENERAL NOTES 1. PARCEL TAX MAP DESIGNATION: SECTION: 24.10, BLOCK: 1, LOT(S): 4 100' WETLAND BUFFER 2. TOTAL AREA OF PROPERTY: 785,997 SQUARE FEET (18.044 ACRES). LOCATION MAP SCALE: 1" = 500' PROP. FENCE AROUND 3. SURVEY & TOPOGRAPHIC INFORMATION SHOW HEREON IS BASED ON A SURVEY PREPARED BY BADEY & WATSON OUTSIDE OF SURVEYING AND ENGINEERING, D.P.C. ENTITLED "SURVEY OF PROPERTY PREPARED FOR CORTLANDT SELF-STORAGE, CONTRACTOR'S YARD L.P..." DATED JULY 2, 2025, LAST REVISED SEPTEMBER 18, 2026. THE CONSERVATION EASEMENT SHALL BE FIELD STAKED BY A NYS LICENSED 100 YEAR FLOOD PLAIN 4. PARCEL IS LOCATED IN THE TOWN OF CORTLANDT M-1 (LIGHT INDUSTRIAL) ZONING DISTRICT. EXISTING STORMWATER SURVEYOR PRIOR TO BUILDING BOUNDARY PER BASIN TO BE ENLARGED DEPARTMENT PERMIT ISSUANCE. AT NO WESTCHESTER COUNTY 5. PARCEL IS LOCATED IN THE HUDSON RIVER BASIN. TO ACCOMMODATE POINT SHALL THE CONSERVATION GIS INCREASE IN IMPREVIOUS EASEMENT BE ENCROACHED UPON. AREAS SINCE 2007 APPROVAL SEE SHEET SP-1.2 (LARGER SCALE) LIST OF DRAWINGS PROP. FENCE AROUND SHEET TITLE SHEET NUMBER TITLE ISSUE DATE LAST REVISED OUTSIDE OF CONTRACTOR'S YARD SP-1.1 1 OF 6 AMENDED SITE PLAN JULY 17, 2026 SEPTEMBER 23, 2026 AMENDED SITE PLAN SP-1.2 2 OF 6 JULY 17, 2026 SEPTEMBER 23, 2026 (LARGER SCALE) SP-1.3 3 OF 6 SITE ADDITIONS 9/23/2026 - SEE DETAIL (LARGER SCALE) FS FS PROPOSED CONTRACTOR STORAGE CD-2.1 4 OF 6 CONSTRUCTION DETAILS AUGUST 19, 2026 SEPTEMBER 23, 2026 FS FS SELF STORAGE BU AREA #1 (6,430 SF) 60 0 30 60 ILDING NO. 11 FS 40' x 130' (EQUIPMENT, TRUCKS & CONTAINER STORAGE) FP-3.1 5 OF 6 FIRST FLOOR PLANS AUGUST 19, 2025 SEPTEMBER 23, 2026 4"Ø GRAVITY FS PIPE FS FS FS FP-3.2 6 OF 6 SECOND FLOOR PLANS AUGUST 19, 2025 SEPTEMBER 23, 2026 SCALE: 1" = 60 FT. FS APPROXIMATE LOCATION OF EXISTING EXISTING SEWER BATHROOM STRUCTURE & PUMPS 8"Ø GRAVITY SANITARY SEWER MAIN APPLICANT THROUGH "PONDVIEW" DEVELOPMENT FS FS OFFICE CORTLANDT SELF STORAGE, L.P. C/O MARK GIORDANO FS EXIST 4"Ø GRAVITY PIPE FS FS FS FS 44 REGINA AVENUE FS FS FS FS FS FS FS FS FS CORTLANDT MANOR, NEW YORK 10567 BATHROOM · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE CONTRACTOR STORAGE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AREA #2 (3,570 SF) · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. (EQUIPMENT, TRUCKS & SEE SHEET SP-1.2 (LARGER SCALE) CONTAINER STORAGE) EXISTING REFUSE AREA REVISIONS 5 4 EXISTING PARKING 3 UPDATE FOR PLANNING BOARD RE-SUBMISSION 09-23-2026 AREAS NOT PART OF OUTSIDE CONTRACTOR 2 UPDATE FOR PLANNING BOARD SUBMISSION 08-19-2026 STORAGE AREAS 1 MOVED BUILDING #11 TO 2' OFF OF EASEMENT 08-03-2026 # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 24.10 BLOCK: 1 LOT: 4 SUBLOT: - AMENDED SITE DEVELOPMENT PLAN DRAWN BY: AD/JCA CHECKED: JCA/PMB PROJECT: SCALE: 1" = 60' DATE: GIORDANO SEPTEMBER 18, 2026 PROPOSED FENCING ON PATRICK M. BELL, P.E. TWO SIDES OF YARD JOB #: 240101 LICENSE #087679 (THIRD LEFT OPEN FOR ACCESS) PROPOSED SPACE FOR CARGO CONTAINERS BUILDING BUILDING CHART TOWN OF CORTLANDT APPROVAL CRONIN PROPOSED SPACE FOR DUMP TRUCKS NO. 1 AREA (SF) 5,200 SF CURRENT USE SELF STORAGE PROPOSED USE SELF STORAGE ENGINEERING PROFESSIONAL ENGINEERING & CONSULTING CONTRACTOR STORAGE AREA #2 (3,570 SF) EQUIPMENT, TRUCKS & 2 10,500 SF SELF STORAGE SELF STORAGE (914) 736-3664 CONTAINER STORAGE). SURFACE FINISH: 3 5,000 SF SELF STORAGE SELF STORAGE ASPHALT AND GRAVEL STONE. NO AGGREGATE MATERIAL TO BE 4 7,250 SF SELF STORAGE SELF STORAGE 39 Arlo Lane STORED IN YARD Cortlandt Manor, New York 10567 PROPOSED SPACE 5 6,500 SF SELF STORAGE SELF STORAGE FOR EXCAVATORS 6 7,500 SF SELF STORAGE SELF STORAGE SITE DEVELOPMENT PLAN 7 6,000 SF SELF STORAGE SELF STORAGE PROPOSED SPACE FOR BACKHOES/MISC. EQUIPMENT 4,000 SF 8 SELF STORAGE SELF STORAGE EQUIPMENT STORAGE OR SELF AMENDED 9 7,442 SF EQUIPMENT STORAGE STORAGE SITE DEVELOPMENT PLAN 10 3,000 SF MECHANIC SHOP MECHANIC SHOP FOR 11 5,200 SF N/A SELF STORAGE CORTLANDT SELF-STORAGE, L.P. TOTAL 67,592 SF CONTRACTOR AREA #1 LOCATION: REGINA AVENUE TOWN OF CORTLANDT, NEW YORK SCALE: 1" = 20' SHEET 1 OF 6 SP-1.1 Page 21 ET RE ST PROPOSED RELOCATED MA IN EXISTING PROPOSED PAVEMENT ST DRAINAGE LINE ±173' LENGTH EA DRAINAGE LINE TO AND CURB FOR EXISTING CURB TO BE REMOVED EXISTING WALL PROPOSED NEW BUILDING OVER EXISTING GUIDERAIL TO BE 15" HDPE BE CUT AND BUILDING ACCESS TO BE REMOVED PERVIOUS GROUND REMOVED FOR PLATFORM @ 11.5% SLOPE CAPPED (AREA #3: 471 SF) ASPHALT AROUND (AREA #4: 422 SF) INSTALLATION BUILDING TO BE REMOVED CORTLANDT CORTLANDT ANY EQUIPMENT PLACED OVER THE PROPOSED PLATFORM FOR DRAINAGE EASEMENT WILL BE DOOR ACCESS RELOCATED ELSEWHERE ONSITE IF ACCESS TO THE EASEMENT IS REQUIRED. WHILE THE DRAINAGE EASEMENT EXISTS, THERE IS NO DRAINAGE INFRASTRUCTURE CURRENTLY INSTALLED IN IT. SITE CORTLANDT CORTLANDT PROPOSED FENCING AROUND OUTSIDE 3 SIDES OF PROPOSED SILT FENCE (SEE CONTRACTOR'S YARD (ROAD DETAIL) SIDE LEFT OPEN FOR ACCESS) LOCATION MAP SCALE: 1" = 700' SPACE FOR DUMP-TRUCKS FS FS FS FS FS FS A PROPOSED CONTRACTOR STORAGE AREA #1 PROP ENTRANCE SELF STOR FS (6,430 SF). DOORS. (TYP. BOTH AGE BUILD FS SIDES OF BUILDING) ING NO. 11 SURFACE FINISH: GRAVEL STONE 2" FS (40' X 130') MINUS. NO AGGREGATE MATERIAL FS FF = 340.9' A IS TO BE STORED IN YARD. FS 350.1 FS SF = 350.1' EXISTIFN SG P ARKING AR FS E A FS FS PIT 350 FS CH FS FS 350.1 FS FS FS FS FS FS FS FS FS 20 0 10 20 FS EXISTING DROP INLET EXISTING SEWER FORCE SERVICE TO BE REDIRECTED AROUND BUILDING, ELECTRIC MANHOLE PRIOR TO SCALE: 1" = 20 FT. RIM = 328.9' CONSTRUCTION. FS IS TO BE PRESSURE TESTED IN PRESENCE OF DOTS, CRONIN ENGINEERING. A NEW INV IN = 325.6' PROFESSIONAL ENGINEER SHALL PROVIDE A CERTIFICATION OF SAID INSTALLATION/TESTING TO THE TOWN. APPLICANT FS EXISTING DROP INLET RIM = 348.9' INV OUT = 345.4' CORTLANDT SELF STORAGE, L.P. FS C/O MARK GIORDANO 44 REGINA AVENUE FS CORTLANDT MANOR, NEW YORK 10567 FS · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS FS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF FS ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SPACE FOR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE BACKHOES/MISC. FS DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. EQUIPMENT · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. FS FS REVISIONS FS 5 FS 4 SPACE FOR 3 UPDATE FOR PLANNING BOARD RE-SUBMISSION 09-23-2026 EXCAVATORS 2 UPDATE FOR PLANNING BOARD SUBMISSION 08-19-2026 1 MOVED BUILDING #11 TO 2' OFF OF EASEMENT 08-03-2026 # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 24.10 EXISTING REFUSE BLOCK: 1 LOCATION LOT: 4 SUBLOT: - DRAWN BY: AD/JCA CHECKED: JCA/PMB PROJECT: GIORDANO DATE: JULY 17, 2026 PATRICK M. BELL, P.E. JOB #: 240101 LICENSE #087679 CRONIN ENGINEERING SITE PLAN NOTES: SITE DEVELOPMENT PLAN INCREASE IN IMPERVIOUS AREA CHART PROFESSIONAL ENGINEERING & CONSULTING (914) 736-3664 1. ALL ROOF LEADERS AND FOOTING DRAINS TO TIE INTO EXISTING DRAINAGE. 2. ALL DISTURBED AREAS SHALL BE 100% STABILIZED AND PLANTED PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. SCALE: 1" = 20' REGION PROPOSED AREA (SF) 39 Arlo Lane 3. THE APPLICANT SHALL SUBMIT AN "AS-BUILT" SURVEY OF ALL IMPROVEMENTS TO BE DEDICATED TO THE TOWN OF CORTLANDT FOR REVIEW AND APPROVAL PRIOR TO ACCEPTANCE OF THE DEDICATION. AREA #1 623 SF Cortlandt Manor, New York 10567 4. PRIOR TO THE BACKFILLING OF ANY STORMWATER BEST MANAGEMENT PRACTICE, DOTS-ENGINEERING SHALL BE NOTIFIED TO PERFORM AN INSPECTION. AREA #2 97 SF 5. ALL PROPOSED IMPORTED FILL MUST BE TESTED AND CERTIFIED AS UNRESTRICTED, SUITABLE FOR RESIDENTIAL USE IN SITE DEVELOPMENT PLAN ACCORDANCE WITH TOWN POLICY. CERTIFICATION MUST BE PROVIDED BY A LICENSED PROFESSIONAL. ALL CERTIFICATIONS SHALL BE ADDRESSED TO THE TOWN'S PLANNING BOARD ENGINEER. ALL SOIL ANALYTICS AND REPORTS SHALL BE FORWARDED TO THE TOWN'S AREA #3 471 SF PLANNING BOARD ENGINEER FOR REVIEW AND APPROVAL. 6. PRIOR TO ACCEPTANCE OF THE ROAD AND DRAINAGE FACILITIES, THE TOWN WILL REQUIRE A CERTIFICATION FROM A NYS ENGINEER THAT THE COMPLETED WORK AND DRAINAGE IMPROVEMENTS WILL NOT CAUSE AN ADVERSE IMPACT TO ADJOINING OR DOWNSTREAM AMENDED AREA #4 422 SF PROPERTIES. SITE DEVELOPMENT PLAN 7. ROCK RIPPING WILL BE USED WHEREVER POSSIBLE. IF BLASTING IS REQUIRED, IT WILL REQUIRE PRIOR APPROVAL FROM THE TOWN 1,653 SF FOR OF CORTLANDT AND AN AIR QUALITY PERMIT FROM THE WESTCHESTER COUNTY DEPARTMENT OF HEALTH. TOTAL INCREASE CORTLANDT SELF-STORAGE, L.P. 8. THERE SHALL BE NO PROCESSING OF EXCAVATED MATERIALS BY A ROCK CRUSHER OR SIMILAR EQUIPMENT ONSITE 9. NO FOUNDATION DRAINS SHALL BE DISCHARCHED INTO THE ONSITE DRAINAGE SYSTEM. 10. THE PROCESSING OF MATERIALS IS NOT PERMITTED ON THE SITE LOCATION: REGINA AVENUE 11. AREAS NOT DESIGNATED FOR OUTDOOR STORAGE AND CONTRACTOR'S YARD SHALL NOT BE UTILIZED AS SUCH. TOWN OF CORTLANDT, NEW YORK 12. NO OUTDOOR REPAIR OF EQUIPMENT SHALL OCCUR. EQUIPMENT SHALL ONLY BE LOCATED IN THOSE AREAS DELINEATED AS "EQUIPMENT PARKING AND STORAGE." SHEET 2 OF 6 SP-1.2 Page 22 ET RE ST IN MA ST EA CORTLANDT ZONING DATA CHART - M-1 (LIGHT INDUSTRIAL) CORTLANDT MINIMUM MINIMUM MAXIMUM MINIMUM MINIMUM MINIMUM MAXIMUM LOT AREA LOT WIDTH HEIGHT FRONT YARD SIDE YARD REAR YARD MAXIMUM LOT DESCRIPTION BUILDING (SF) (FT) (FT) (FT) (FT) (FT) FLOOR AREA COVERAGE 75,000 SF / REQUIRED 20,000 100 40 40 20 30 275,098 SF BUILDING PROPOSED 785,997 121 23 130.3 21.8 54.3 67,952 SF 9,728 SF (BLDG 11) SITE CORTLANDT CORTLANDT 100' WETLAND BUFFER LOCATION MAP SCALE: 1" = 500' 9'X20' PARKING SPACES PARKING AREA (CHANGE #4) PARKING AREA (CHANGE #3) 8.5'X18' PARKING SPACES FS FS FS FS 60 0 30 60 FS FS FS FS FS SCALE: 1" = 60 FT. FS APPLICANT FS FS CORTLANDT SELF STORAGE, L.P. C/O MARK GIORDANO FS FS FS FS FS 44 REGINA AVENUE FS FS FS FS FS FS FS FS FS CORTLANDT MANOR, NEW YORK 10567 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE TRAILER STORAGE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ADDED BEHIND · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. BUILDING 8 (CHANGE #6) PAVEMENT ADDED REVISIONS BEHIND BUILDING 9 9'X18' PARKING SPACES 5 (CHANGE #7) PARKING ADDED TO 4 ACCESS DRIVE SOUTHWEST OF PARKING TO SOUTHWEST OF (CHANGE #8) BUILDING 5 (CHANGE #5) BUILDING #6 (CHANGE #2) 3 ACCESS DRIVE TO REAR OF BUILDINGS 6 2 & 7, RETAINING WALLS TO SUPPORT 1 ACCESS DRIVE. (CHANGE # 1) # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 24.10 BLOCK: 1 LOT: 4 SUBLOT: - SITE ADDITIONS PLAN DRAWN BY: LC CHECKED: JCA/PMB DISTURBED AREA SINCE 2008 APPROVED PLAN PROJECT: AREA (SF) SCALE: 1" = 60' DATE: GIORDANO SEPTEMBER 23, 2026 CHANGE NO. REGION PATRICK M. BELL, P.E. JOB #: 240101 LICENSE #087679 1 ACCESS DRIVE BEHIND BUILDINGS 6 & 7 6,610.91 CRONIN PARKING ON SOUTHWEST CORNER OF 2 4,096.23 BUILDING 6 3 PARKING AREA 4,346.83 4 PARKING AREA 3,474.71 ENGINEERING PARKING TO THE SOUTHWEST OF PROFESSIONAL ENGINEERING & CONSULTING 5 3,629.04 BUILDING #5 (914) 736-3664 TRAILER PARKING BETWEEN BUILDINGS 1 6 747.46 &8 7 PARKING TO SOUTHWEST OF BUILDING #9 1,267.35 39 Arlo Lane 8 ACCESS DRIVE BEHIND BUILDING #2 4086.11 Cortlandt Manor, New York 10567 - CONTRACTOR STORAGE 10,000 SITE ADDITIONS PLAN - TOTAL 38,253 (0.878 AC) AMENDED SITE ADDITION NOTES: SITE DEVELOPMENT PLAN FOR 1. ALL CHANGES ARE SHOWN AS COMPARED TO APPROVED PLAN DATED JANUARY 25, 2006 BY RALPH MASTROMONACO P.E. P.C. CORTLANDT SELF-STORAGE, L.P. 2. BUILDING #8 WAS MOVED 10 FEET SOUTH SINCE ORIGINAL PLAN 3. MULTIPLE RETAINING WALLS WERE CONSTRUCTED TO SUPPORT THE ACCESS DRIVE BEHIND BUILDINGS 6 & 7 LOCATION: REGINA AVENUE TOWN OF CORTLANDT, NEW YORK SHEET 3 OF 6 SP-1.3 Page 23 PROVIDE R-19 ET RE ST BATT AIN TM INSULATION EA S AT ROOF RAFTERS (TYPICAL) UPPER LEVEL PROVIDE CLOSED-CELL SPRAY 10 X 7.5 STORAGE UNIT 13 UNITS FOAM INSULATION (R-VALUE: (TYP. WALKWAY MIN. 6.5 FOR TOTAL OF 22.75) AT CORTLANDT ADJOINERS) CORTLANDT ALL EXTERIOR STEEL-FRAMED WALLS (TYPICAL) EXISTING GRADE GROUND ELEV. = 350.1) PROPOSED UPPER LEVEL (ELEV. = 350.1) SITE 10 X 10 STORAGE UNIT LOWER LEVEL (TYP.) 13 UNITS CORTLANDT CORTLANDT GROUND ELEV. = 340.9 PROPOSED LOWER LEVEL (ELEV. = 340.9) LOCATION MAP SCALE: 1" = 700' 10' FILTER X, MIRAFI 100X, OR STABILINKA T140N FILTER CLOTH OR APPROVED EQUAL WOVEN WIRE FENCE (MIN. 14 12 GAUGE W/ MAX 6" MESH SPACING 6" MIN MAX. SECTION "A-A" EROSION AND SEDIMENT CONTROL NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SEDIMENT AND EROSION CONTROL PRACTICES. THE SEDIMENT AS DEEMED NECESSARY BY QUALIFIED INSPECTOR.) 2" X 2" WOOD POST, NO. 2 SCALE: 1" = 5' AND EROSION CONTROL PRACTICES ARE TO BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCES, AND MAINTAINED UNTIL PERMANENT PROTECTION IS ESTABLISHED. RE-BAR OR STEEL PICKETS MIN 2. TIMELY MAINTENANCE OF SEDIMENT CONTROL STRUCTURES IS THE RESPONSIBILITY OF THE CONTRACTOR. ALL STRUCTURES 6" SHALL BE MAINTAINED IN GOOD WORKING ORDER AT ALL TIMES. THE SEDIMENT LEVEL IN ALL SEDIMENT TRAPS SHALL BE CLOSELY 2" ASPHALT TOP COURSE, NYSDOT MONITORED AND SEDIMENT REMOVED PROMPTLY WHEN MAXIMUM LEVELS ARE REACHED OR AS ORDERED BY THE ENGINEER. ALL SAWCUT TRENCH TO SEDIMENT CONTROL STRUCTURES SHALL BE INSPECTED WEEKLY, PRIOR TO EXPECTED RAIN EVENTS, AND AFTER EACH HEAVY ITEM 403.178302 THE BOTTOM OF THE (SEE NOTE 13 FOR DRIVEWAY RAIN TO ENSURE PROPER OPERATION AS DESIGNED. AN INSPECTION SCHEDULE SHALL BE SET FORTH PRIOR TO THE START OF ROAD COURSE RESTORATION) CONSTRUCTION. 2'-6" MIN MATERIAL (ITEM 4) WITH SAW CUT A STRAIGHT AND F LO SAW CUT W VERTICAL EDGE, TACK 3. THE LOCATIONS AND THE INSTALLATION TIMES OF THE SEDIMENT CAPTURING STANDARDS SHALL BE AS ORDERED BY THE FILTER X, MIRAFI 100X, OR STABILINKA T140N FILTER COAT ALL EXPOSED ENGINEER, AND IN ACCORDANCE WITH ACCEPTED STANDARDS. CLOTH OR APPROVED EQUAL EDGES WITH RC-250 1' 1' 4. ALL TOPSOIL NOT TO BE USED FOR FINAL GRADING SHALL BE REMOVED FROM THE SITE IMMEDIATELY AND PLACED IN A STABILIZED WOVEN WIRE FENCE (MIN. 14 12 GAUGE W/ MIN MIN EXISTING ROAD STOCKPILE OR FILL AREA. ALL TOPSOIL REQUIRED FOR FINAL GRADING AND STORED ON SITE SHALL BE LIMED,FERTILIZED, MAX 6" MESH (AS DEEMED NECESSARY BY SURFACE 1'-6" MIN TEMPORARILY SEEDED AND MULCHED WITHIN 14 DAYS. MIN. QUALIFIED INSPECTOR.) 6" 4" ASPHALT BINDER COURSE, NYSDOT ITEM 403.138902 5. ANY DISTURBED AREAS THAT WILL BE LEFT EXPOSED MORE THAN 21 DAYS AND NOT SUBJECT TO CONSTRUCTION TRAFFIC, SHALL 2" X 2" WOOD POST, NO. 2 IMMEDIATELY RECEIVE TEMPORARY SEEDING. MULCH SHALL BE USED IF THE SEASON PREVENTS THE ESTABLISHMENT OF A 8" (COMPACTED) ITEM 4, NYSDOT TOE-IN FILTER FABRIC, RE-BAR OR STEEL PICKETS TEMPORARY COVER. DISTURBED AREAS SHALL BE LIMED AND FERTILIZED PRIOR TO TEMPORARY SEEDING. ITEM 304.14 BACKFILL AND TAMP SOIL TO SECURE FABRIC IN PLACE FRONT VIEW METALLIC TAPE LABELED 6. ALL DISTURBED AREAS WITHIN 500 FEET OF AN INHABITED DWELLING SHALL BE WETTED AS NECESSARY TO PROVIDE DUST MIN 24" MECHANICALLY COMPACTED CLEAN GRANULAR 24" + PIPE Ø "CAUTION SEWER LINE CONTROL. SECTION VIEW FILL ONLY BELOW" AT 12" & 24" BELOW NO STONES GREATER THAN 2" FINISHED GRADE OVER 1' 1' 7. THE CONTRACTOR SHALL KEEP THE ROADWAYS WITHIN THE PROJECT CLEAR OF SOIL AND DEBRIS AND IS RESPONSIBLE FOR ANY AND NO ORGANIC MATERIAL SEWER PIPING. FILTER X, MIRAFI 100X, OR PERMITTED. CLEAN FILL TO RUN MIN MIN STREET CLEANING NECESSARY DURING THE COURSE OF THE PROJECT. STABILINKA T140N FILTER MIN FULL LENGTH OF TRENCH (OR K-CRETE APPLICANT 6" CLOTH OR APPROVED EQUAL OR ITEM 4 AS SPECIFIED PER MUNICIPALITY) 8. SEDIMENT AND EROSION CONTROL STRUCTURES SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE DRAINAGE AREA HAS S BEEN PROPERLY STABILIZED BY PERMANENT MEASURES. WOVEN WIRE FENCE (MIN. 14 12 3 6" MIN. IN EARTH GAUGE W/ MAX 6" MESH SPACING 4" CRUSHED GRAVEL 9. SOIL SEEDING AND FERTILIZER AMENDMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITION OF "NEW YORK 12" MIN. IN ROCK AS DEEMED NECESSARY BY QUALIFIED INSPECTOR.) SEWER SERVICE PIPING GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL". CORTLANDT SELF STORAGE, L.P. UNDISTURBED OR COMPACTED EARTH 10. ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION OF "NEW EXISTING / FINAL GRADE (SEE PLAN FOR SIZE & MATERIAL) YORK GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL". C/O MARK GIORDANO W F LO 44 REGINA AVENUE CORTLANDT MANOR, NEW YORK 10567 SEWER SERVICE INSTALLATION NOTES: JOINING SECTIONS TOP VIEW 1. THE CONTRACTOR SHALL CALL IN A "CODE 753" PRIOR TO EXCAVATION. 2. ALL SANITARY SEWER SERVICE PIPING TO BE AS SPECIFIED ON SITE DEVELOPMENT PLANS. 3. SANITARY SEWER SERVICE PIPING SHALL HAVE A MINIMUM OF 2'-0" COVER OVER PIPE. IF THIS IS NOT POSSIBLE THE OWNER/APPLICANT SHALL CONTACT THE MUNIPALITIES ENGINEERING DIVISION PRIOR TO · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS TOE-IN FILTER FABRIC, CONSTRUCTION. UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS BACKFILL AND TAMP SOIL TO 4. SANITARY SEWER MAIN RUNS SHALL HAVE A MINIMUM SLOPE OF 1.0%. SECURE FABRIC IN PLACE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF 5. SANITARY SEWER SERVICE RUNS SHALL HAVE A MINIMUM SLOPE OF 2.0% FOR 4" DIA. PIPES. 6. MAXIMUM RUN BETWEEN MANHOLES SHALL BE 300'. ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS ISOMETRIC VIEW. 7. NO ROCK SHALL PROJECT WITHIN THE SURFACE OF THE TRENCH AND ALL ROCK SHALL BE A MINIMUM OF 12" SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE OW FL FROM THE PIPE HORIZONTALLY. IF BEDROCK IS ENCOUNTERED DURING INSTALLATION, IT SHALL BE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. EXCAVATED TO A MINIMUM DEPTH OF 4' + PIPE Ø + 6" AND REPLACED WITH 6" OF SAND. 6" X 6" X 6" TRENCH · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. 8. SANITARY SEWER SHALL BE ANCHORED AT EACH BELL WHERE SLOPE OF PIPE EXCEEEDS 20%. 9. DEBRIS, FROZEN MATERIAL, LARGE CLODS OR STONES, ORGANIC MATTER OR OTHER UNSUITABLE MATERIALS INSTALLATION NOTES: SHALL NOT BE USED AS BACKFILL. 10. 11. BACKFILL SHALL BE PLACED SO AS NOT TO DISTURB THE PIPE ALIGNMENT. SELECT AND BACKFILL MATERIAL SHALL BE PLACED IN 12" LIFTS (PRIOR TO COMPACTION) AND COMPACTED REVISIONS 1. EXCAVATE A 4 INCH X 4 INCH TRENCH ALONG THE LOWER SIDE OF A SLOPE AS SPECIFIED ON SITE PLAN. WITH A MECHANICAL TAMPER. 5 2. UNROLL A SECTION AT A TIME AND POSITION THE POSTS AGAINST THE BACK (DOWNHILL) WALL OF THE 12. CONTRACTOR TO NOTIFY MUNICIPALITY 48 HOURS IN ADVANCE FOR TRENCH INSPECTION. TRENCH (NET SIDE AWAY FROM DIRECTION OF STORM WATER FLOW). 13. CLAY, SILT LOAM OR NON SOILS REQUIRE SHORING AND BRACING. SHEETING AND BRACING SHALL BE USED IN 3. DRIVE THE POST INTO THE GROUND UNTIL THE NETTING IS APPROXIMATELY 2 INCHES FROM THE TRENCH ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR INDUSTRIAL CODE, RULE 753 WHERE 4 BOTTOM. REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH DEPTHS EXCEED 5' IN HEIGHT. 4. LAY THE TOE-IN FLAP OF FABRIC FLAT IN THE BOTTOM OF THE TRENCH AND BACKFILL THE TRENCH AND TAMP 14. ASPHALT DRIVEWAY RESTORATION TO CONSIST OF 6" COMPACTED ITEM 4 (NYSDOT ITEM 304.05) UNDER 2.5" THE SOIL OVER THE FLAP TO SECURELY HOLD THE FABRIC IN PLACE. STEEPER SLOPES REQUIRE AN 3 OF ASPHALT CONCRETE TOP COURSE (NYSDOT ITEM 403.178302). INTERCEPT TRENCH. 5. JOIN SECTIONS AS SHOWN ABOVE 2 6. PREFABRICATED UNITS SHALL BE OF TYPE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. SEWER SERVICE INSTALLATION N.T.S. 1 UPDATE FOR PLANNING BOARD RE-SUBMISSION 09-23-2026 SILT FENCE INSTALLATION N.T.S. W/ PAVEMENT RESTORATION # REASON DATE UN-PAVED CONDITION PAVED CONDITION MUNICIPAL TAX IDENTIFICATION: 212" ASPHALT TOP COURSE FINISHED GRADE (SEE PAVING (NYSDOT item no. 403.178302) SECTION WHERE PAVED) SECTION: 24.10 4" OF TOPSOIL SAWCUT LOCATION EACH SIDE (WHERE APPLICABLE) BLOCK: 1 6" (COMPACTED) ITEM 4 PA (NYSDOT item no. 304.14) CO VED ND LOT: 4 WHERE SAWCUTTING IS REQUIRED, ITI ON CUT TRENCH TO BOTTOM OF EXISTING ROAD COARSE MATERIAL SUBLOT: - WITH A STRAIGHT VERTICAL EDGE (SEE PLAN) AND TACK COAT ALL EXPOSED DRAWN BY: LC VARIES UN N.T.S. COMPACTED SUBGRADE EDGES WITH RC-250 CO -PA 12" MIN. ND VED ITI ON CHECKED: JCA/PMB BACKFILL WITH K-CRETE DRIVEWAY PAVING SECTION BACKFILL WITH CLEAN MATERIAL (NO LARGE UNDER PAVED AREAS PROJECT: GIORDANO STONES OR ORGANICS) UNDER DATE: AUGUST 19, 2026 UN-PAVED AREAS. BACKFILL TO TOP OF PIPE WITH PATRICK M. BELL, P.E. POROUS FILL MATERIAL. JOB #: 240101 LICENSE #087679 PIPE Ø CRONIN 12" MIN. 12" MIN. DRAINAGE PIPE (SEE D UNDISTURBED OR 24" + PIPE Ø COMPACTED EARTH PLAN FOR MATERIAL, SIZE AND SLOPE) SECTION D ENGINEERING PROFESSIONAL ENGINEERING & CONSULTING STORMWATER PIPE INSTALLATION NOTES (914) 736-3664 1. SHEETING AND BRACING SHALL BE USED IN ACCORDANCE WITH OSHA AND THE NYS DEPARTMENT OF LABOR INDUSTRIAL CODE, RULE 753 WHERE REQUIRED. SHEETING & BRACING ARE REQUIRED WHERE TRENCH DEPTHS EXCEED 5' IN HEIGHT. SHEETING & BRACING ARE ALSO REQUIRED WHEN CLAY, SILT LOAM OR NON SOILS ARE ENCOUNTERED. 2. THE CONTRACTOR SHALL CALL IN A "CODE 753" PRIOR TO EXCAVATION. 39 Arlo Lane 3. ALL DRAINAGE PIPING TO BE AS SPECIFIED ON SITE DEVELOPMENT PLANS. Cortlandt Manor, New York 10567 4. REFER TO PIPE MANUFACTURER SPECIFICATIONS FOR MAXIMUM COVER REQUIREMENTS. IF THIS IS NOT POSSIBLE THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER PRIOR TO CONSTRUCTION. 5. DRAINAGE PIPE RUNS SHALL MATCH MATERIAL AND SLOPE SPECIFIED ON PLANS. 6. NO ROCK SHALL PROJECT WITHIN THE SURFACE OF THE TRENCH AND ALL ROCK SHALL BE A MINIMUM OF 12" FROM THE PIPE CONSTRUCTION DETAILS HORIZONTALLY. IF BEDROCK IS ENCOUNTERED DURING INSTALLATION, IT SHALL BE EXCAVATED TO A MINIMUM DEPTH OF 6" BELOW BOTTOM OF PIPE AND REPLACED WITH 6" OF SAND. 7. DEBRIS, FROZEN MATERIAL, LARGE CLODS OR STONES, ORGANIC MATTER OR OTHER UNSUITABLE MATERIALS SHALL NOT BE USED AS BACKFILL. AMENDED 8. BACKFILL SHALL BE PLACED SO AS NOT TO DISTURB THE PIPE ALIGNMENT. 9. SELECT AND BACKFILL MATERIAL SHALL BE PLACED IN 12" LIFTS (PRIOR TO COMPACTION) AND COMPACTED WITH A MECHANICAL TAMPER. SITE DEVELOPMENT PLAN FOR DD-3 STORMWATER PIPE INSTALLATION NTS CORTLANDT SELF-STORAGE, L.P. LOCATION: REGINA AVENUE TOWN OF CORTLANDT, NEW YORK SHEET 4 OF 6 CD-2.1 Page 24 ET RE ST AIN S TM EA CORTLANDT CORTLANDT 2ND FLOOR ELEVATION = 350.1 GRADE AT NORTH END GRADE = 350.1 SITE CORTLANDT CORTLANDT 1ST FLOOR ELEVATION = 340.9 LOCATION MAP SCALE: 1" = 700' GRADE AT SOUTH END GRADE = 340.9 FRONT (EAST) SCALE: 1"=5' APPLICANT CORTLANDT SELF STORAGE, L.P. C/O MARK GIORDANO 44 REGINA AVENUE CORTLANDT MANOR, NEW YORK 10567 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. REVISIONS 5 4 3 2 1 UPDATE FOR PLANNING BOARD RE-SUBMISSION 09-23-2026 # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 24.10 BLOCK: 1 1ST FLOOR LAYOUT LOT: 4 SCALE: 1"=5' SUBLOT: - DRAWN BY: LC 12 12 CHECKED: JCA/PMB 1 1 PROJECT: GIORDANO DATE: AUGUST 19, 2026 PATRICK M. BELL, P.E. JOB #: 240101 LICENSE #087679 CRONIN ENGINEERING PROFESSIONAL ENGINEERING & CONSULTING 2ND FLOOR ELEVATION = 350.1 GRADE AT NORTH END (914) 736-3664 39 Arlo Lane Cortlandt Manor, New York 10567 GRADE AT REAR (WEST) DOOR DOOR 3'-0"W x 3'-0"W x FIRST FLOOR FLOOR PLANS CONSERVATION LINE 7'-0"H 7'-0"H GRADE AT SOUTH END 1ST FLOOR ELEVATION = 340.9 AMENDED NOTE: MAXIMUM BUILDING HEIGHT IS 23' COMPARED TO 40' MAXIMUM IN M-1 LIGHT INDUSTRIAL DISTRICT SITE DEVELOPMENT PLAN FOR CORTLANDT SELF-STORAGE, L.P. SIDE (SOUTH) LOCATION: REGINA AVENUE SCALE: 1"=5' TOWN OF CORTLANDT, NEW YORK SHEET 5 OF 6 FP-3.1 Page 25 METAL ROOF: ET COLOR TO MATCH EXISTING BUILDINGS RE ST AIN S TM EA ALUMINUM GUTTERS AND LEADERS: COLOR TO MATCH EXISTING BUILDINGS CORTLANDT CORTLANDT ALUMINUM CORNER TRIM: COLOR TO MATCH EXISTING BUILDINGS METAL RIBBED SIDING PANELS: COLOR TO MATCH EXISTING BUILDINGS GRADE AT NORTH END GRADE = 350.1 2ND FLOOR ELEVATION = 350.1 SITE CORTLANDT CORTLANDT GRADE AT SOUTH END GRADE = 340.9 LOCATION MAP SCALE: 1" = 700' 1ST FLOOR ELEVATION = 340.9 REAR (WEST) SCALE: 1"=5' APPLICANT CORTLANDT SELF STORAGE, L.P. C/O MARK GIORDANO 44 REGINA AVENUE CORTLANDT MANOR, NEW YORK 10567 · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. REVISIONS 5 4 3 2 1 # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 24.10 BLOCK: 1 2ND FLOOR LAYOUT LOT: 4 SCALE: 1"=5' SUBLOT: - DRAWN BY: LC CHECKED: JCA/PMB PROJECT: GIORDANO 12 12 1 1 DATE: SEPTEMBER 23, 2026 METAL ROOF: PATRICK M. BELL, P.E. COLOR TO MATCH EXISTING JOB #: 240101 LICENSE #087679 BUILDINGS ALUMINUM GUTTERS AND LEADERS: COLOR TO MATCH EXISTING BUILDINGS CRONIN METAL RIBBED SIDING PANELS: GRADE AT REAR (WEST) GRADE AT REAR ENGINEERING COLOR TO MATCH EXISTING BUILDINGS PROFESSIONAL ENGINEERING & CONSULTING DOOR DOOR 3'-0"W x 3'-0"W x (914) 736-3664 CONSERVATION LINE 7'-0"H 7'-0"H ALUMINUM CORNER TRIM: COLOR TO MATCH EXISTING BUILDINGS GRADE AT NORTH END 2ND FLOOR ELEVATION = 350.1 39 Arlo Lane Cortlandt Manor, New York 10567 SECOND FLOOR FLOOR PLANS AMENDED 1ST FLOOR ELEVATION = 340.9 SITE DEVELOPMENT PLAN FOR SIDE (NORTH) CORTLANDT SELF-STORAGE, L.P. SCALE: 1"=5' LOCATION: REGINA AVENUE TOWN OF CORTLANDT, NEW YORK SHEET 6 OF 6 FP-3.2 Page 26 TE O F NE W Y I F ER W RE PRINTED O JE A NN T RK S AP September 18, 2026 _________________________ BADEY & WATSON R L IC E X C E L S IO R YO NS 5 0 3 8 9 VE Surveying & Engineering, D.P _________________________ E ED L A ND SUR Page 27 Description of Easement Area prepared for CORTLANDT SELF-STORAGE, L.P. (Waterline Easement to Town of Cortlandt) AN EASEMENT on that certain parcel of land situate in the Town of Cortlandt, County of Westchester, and State of New York that is a portion of those lands that were heretofore conveyed by Mark Giordano to Cortlandt Self-Storage, L.P. by that certain deed dated June 12, 1999, and recorded in the Westchester County Clerk’s Liber 12327 of deeds at page 331 that is bounded and described as follows: BEGINNING at the point that is the northeasterly corner of Lot 1 on that certain “Subdivision Map of Regina Estates …,” which was filed in the Westchester County Clerk’s office on February 13, 1969 as Map No. 16600, and also a corner of the lands so conveyed to Cortlandt Self-Storage, L.P., on the south and east from lands formerly of Mol-Bet Enterprises, now or formerly of Ryan Main, LLC and now shown on that certain map entitled “Final Subdivision of Property … for Brian Kahn and Robert A Kahn …,” which was filed in the Westchester County Clerk’s office on January 10, 2011, as Map No. 28453, on the north and west. THENCE from the said point of beginning through the lands so conveyed to Cortland Self-Storage, L.P., the following courses: S 74°03'00" E 10.70 feet, S 17°40'21" W 31.87 feet, S 33°33'28" W 71.36 feet, S 15°21'29" W 206.17 feet, S 27°54'43" W 177.66 feet, S 12°36'05" W 231.90 feet, S 77°23'55" E 18.00 feet, S 12°36'05" W 15.00 feet, N 77°23'55" W 18.00 feet, and S 12°36'05" W 182.02 feet, to a point in the center of the stone wall marking the southerly line thereof and the northerly line of lands formerly of Lerose Management Corporation and now or formerly of Lakeland Rentals, Inc. Thence along the said Lakeland Rentals, Inc. lands and the center of the stone wall N 80°43'40" W 8.45 feet, and N 81°46'40" W 6.59 feet, File No. 99-110 Work Order No. 27276-C File Name:Document1 Date Created: September 17, 2026 Date Revised: September 21, 2026 Date Printed: September 21, 2026 Figure No. 308 Author: GJW Page 28 September 21, 2026 CORTLANDT SELF-STORAGE, L.P. Page 2 of 2 Waterline Easement to Town of Cortlandt To a point. Thence once again through the lands so conveyed to Cortlandt Self-Storage, L.P. the following courses N 12°36'05" E 431.93 feet, N 27°54'43" E 130.19 feet, N 62°05'17" W 49.68 feet, N 27°54'43" E 15.00 feet, S 62°05'17" E 49.68 feet, N 27°54'43" E 32.84 feet, N 15°21'29" E 206.92 feet, N 33°33'28" E 71.67 feet, and N 17°40'21" E 28.35 feet, to a point on the southerly line of the said lands formerly of Mol-Bet Enterprises and now shown on Filed Map No. 28453. Thence along the last-mentioned lands S 86°48'00" E 4.45 feet to the point or place of beginning of this easement area. Prepared by BADEY & WATSON Surveying & Engineering, D.P.C. 3063 Route 9 Cold Spring, New York 10516 File X:\PROJECTS\Giordano-44 Regina Ave-Cortlandt\Building #11 and Parking-Jan 2024\Documents\20260923-PB Submission\Watermain Easement-20260921.docx Created: September 16, 2026 Last Revised: September 21, 2026 Printed: September 21, 2026 Page 29 Brian T. Sinsabaugh September 23, 2026 Hon. Steven Kessler, Chairman and Members of the Planning Board Town of Cortlandt One Heady Street Cortlandt Manor, New York 10567 Re: Cortlandt Self-Storage LP (PB2026-12) 44 Regina Avenue (SBL 24.10-1-4) Dear Chairman Kessler and Members of the Board: As the Board is aware, our firm represents Cortlandt Self-Storage LP, owner of the above- referenced property and applicant for amended site plan approval. The application seeks approval for an additional self-storage building and recognition of the property's existing outdoor storage use, which is limited to designated contractor storage areas accessory to the principal self-storage operation. As part of this application, the Applicant has identified a discrepancy between the Town Board's recently adopted Resolution No. 98-2026 and the proposed use of the property. Specifically, the Resolution permits use of the property for “the incidental storage of equipment and material owned by the site property owner,” which does not fully reflect the Applicant's intended storage operations. To address this issue, the Applicant has prepared a draft resolution for consideration by the Town Board clarifying that the Property may be used for "the incidental storage of equipment and materials in connection with, and accessory to, the principal self-storage use of the Property" and that the outdoor storage of equipment, materials, and related items accessory to the principal self- storage use of the Property shall be permitted by third parties.” A copy of the proposed resolution is enclosed and submitted for inclusion in the record for Application PB2026-12. Should you have any questions, please contact the undersigned. Respectfully, ZARIN & STEINMETZ LLP By: David S. Steinmetz Brian T. Sinsabaugh 81 Main Street, Suite 415 White Plains, New York 10601 Page 30 Town of Cortlandt Planning Board Cortlandt Self-Storage LP September 23, 2026 | Page 2 Enclosure cc.: Heather LaVarnway, CNU-A, AICP, Town Planning Director Michael Cunningham, Esq., Town Attorney Mark Giordano, Cortlandt Self-Storage LP Cronin Engineering P.E., PC 4928-9790-6899, v. 1 Page 31 RESOLUTION No. ____________ (A RESOLUTION FURTHER CLARIFYING RESOLUTION NO. 98-2026, WHICH AMENDED AND CLARIFIED RESOLUTION NO. 109-95 REGARDING PERMITTED USES OF PROPERTY LOCATED ON REGINA AVENUE) WHEREAS, Cortlandt Self Storage LP is the owner of the property located at 44 Regina Avenue, Town of Cortlandt, New York, designated on the Town of Cortlandt Tax Map as Section 24.10, Block 1, Lot 4 (the “Property”); and WHEREAS, on April 11, 1995, the Town Board adopted Resolution No. 109-95, pursuant to which the Property was placed within the M-1 Light Industrial District (“M-1 District”) and approved for self-storage use; and WHERAS, on January 9, 2007, the Planning Board adopted Resolution No. 1-07 granting conditional Site Development Plan approval for the development and operation of a self-storage facility on the Property; and WHEREAS, on March 12, 2026, the Town Board adopted Resolution No. 98-2026, which amended and clarified Resolution No. 109-95 by expressly permitting the incidental storage of equipment and materials owned by the Property owner in connection with the approved use of the Property; and WHEREAS, Resolution No. 98-2026 established certain limitations applicable to the Property, including: (i) a maximum aggregate building footprint of 68,000 square feet; (ii) a maximum of eleven (11) buildings, excluding the office building; (iii) a maximum of two (2) buildings utilized for the Property owner's incidental contractor storage; and (iv) outdoor storage not exceeding approximately 10,000 square feet within areas designated on a site plan approved by the Planning Board; and WHEREAS, the Town Board recognizes that the incidental outdoor storage of equipment and materials associated with, and subordinate to, the principal self-storage use has historically occurred on the Property and remains accessory to the approved self-storage use; and WHEREAS, the Town Board finds it appropriate to further clarify the permitted uses of the Property to accurately reflect the longstanding use and operation of the Property; and NOW, THEREFORE, BE IT RESOLVED, that Resolution No. 109-95, as amended by Resolution No. 98-2026, is hereby further amended and clarified to provide that the incidental storage of equipment and materials in connection with, and accessory to, the principal self-storage use of the Property shall be a permitted use of the Property; and Page 32 BE IT FURTHER RESOLVED, that the aggregate building footprint on the Property shall not exceed 68,000 square feet and the total number of buildings on the Property shall not exceed eleven (11), excluding the office building; and BE IT FURTHER RESOLVED, that outdoor storage of equipment, materials, and related items accessory to the principal self-storage use of the Property shall be limited to an area not exceeding approximately 10,000 square feet and shall be confined to locations designated on a site plan approved by the Planning Board; and BE IT FURTHER RESOLVED, that the aggregate building footprint on the Property shall not exceed 68,000 square feet and the total number of buildings on the Property shall not exceed eleven (11), excluding the office building; and BE IT FURTHER RESOLVED, that outdoor storage of equipment, materials, and related items accessory to the principal self-storage use of the Property shall be permitted by third parties; and BE IT FURTHER RESOLVED, that except as expressly clarified herein, all terms, conditions, limitations, and requirements set forth in Resolution No. 109-95 and Resolution No. 98-2026 shall remain in full force and effect. BY ORDER OF THE TOWN BOARD OF THE TOWN OF CORTLANDT LAROUE ROSE SHATZKIN, TOWN CLERK Adopted _______, 2026 at a Regular Meeting held at Town Hall 4914-0959-6624, v. 1 Page 33 September 23, 2026 Steven Kessler, Chairman Town of Cortlandt Planning Board One Heady Street Cortlandt Manor, New York 10567 Re: Amended Site Plan Application Cortlandt Self Storage, L.P. 44 Regina Avenue Town of Cortlandt, New York Tax Map Designation: 24.10-1-4 Dear Chairman Kessler and Members of the Planning Board: Find enclosed eight copies (1 full size set & 7 reduced size sets) of the following information for the above- referenced application: 1. Amended Site Development Plan (6 sheets), dated July 17, 2026, last revised September 23, 2026 This submission addresses the comments made by the Town’s Planning Department (letter dated August 27, 2026) and the Town’s Planning Board Engineering Consultant (letter dated September 10, 2026). Annotated responses to those letters is provided below. Planning Department Review Memo – Dated August 28, 2026 1. Detailed Project Narrative Required: The applicant should provide a detailed project narrative describing the proposed contractor’s yard uses and operations. Specifically, the narrative should include information on how many and what type of construction/oversized vehicles will be stored on site, whether any of these vehicles will be actively operated on the site, and whether employees of the property owner’s other businesses will be parking their private vehicles at the site. Response: All construction and oversized vehicles, including excavators, trailers, Conex boxes, containers, and similar equipment, will be stored within the designated Contractor’s Yards identified as “Contractor Storage Area #1” and “Contractor Storage Area #2” on the enclosed Site Development Plan, sheets SP-1.1 & SP-1.2. No construction work or equipment operation for customers will occur on the site. Activities within the Contractor’s Yard will be limited to vehicle and equipment parking, loading and unloading, inspections, and minor maintenance. In addition, employees of the property owner and contractor may park personal vehicles on the site. These employees typically arrive at the beginning of the workday, park their personal vehicles, utilize the construction vehicles and equipment stored within the Contractor’s Yard for off-site work activities, and return at the end of the workday before departing the site. 2. Conflicting Uses: The contractor’s yard use is currently located in several areas throughout the site, all of which are fully accessible by members of the public who visit the site to access their rented self-storage units. This co-mingling of commercial and industrial uses creates safety concerns as the public should not be in the same vicinity as the heavy equipment and operations associated with the contractor’s yard. For example, oversized construction equipment such as Page 34 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 2 skid steers, front-end loaders and excavators have been observed driving/operating around the site, and other activities such as welding and maintenance of construction equipment have been observed taking place on the paved aprons outside of the self-storage facilities – in areas fully accessible to the public. The applicant shall provide a description of how they propose to safely operate the contractor’s yard on the same site as the self-storage facility. The site plan must be designed to avoid conflicts between the customers of the self-storage facility and the operation of the contractor’s yard. Areas of construction activity need to be clearly delineated and other safety measures, such as fencing and/or consolidation of the contractor’s yard to one area of the site, may need to be considered based on the conflicting activities. Response: The Contractor’s Yard use has been consolidated into Two (2) Designated Areas, as shown on the revised site plan, identified by signage and delineated through fencing, barriers, and pavement markings as appropriate. All contractor vehicles, equipment, and materials will be stored within this area, preventing conflicts with customer parking, drive aisles, loading zones, pedestrian routes, emergency access, and fire lanes. To maintain safe and efficient site circulation, a clearly marked customer route will extend from the site entrance to the self-storage buildings, parking areas, and loading zones and will remain unobstructed at all times. Construction vehicle movements will be limited and managed to avoid interference with self-storage customers. Loading, unloading, and equipment movement will occur within the designated contractor area and, where practicable, during periods of lower customer activity. Any temporary construction or maintenance activity will be clearly delineated with cones, barricades, fencing, warning signs, or similar controls. Appropriate signage will identify the contractor’s yard and restrict access to authorized personnel. Employees will be trained regarding site circulation, speed limits, designated parking areas, and safe operating procedures. The property owner or site manager will conduct periodic inspections to ensure vehicles, equipment, and materials remain within approved areas, maintain clear sightlines and unobstructed public access, and ensure all required safety measures remain in place. Should any site-specific safety concerns arise, the applicant will work with staff to implement reasonable measures while preserving the site's established operation. 3. Site Plan and Architectural(s): Additional information/clarification is needed regarding the site plan, building elevations and floor plans, as follows: a. The site plan should use the most recently approved site plan, dated “REVISED: JANUARY 15, 2008” and signed by the Planning Board Chair on September 3, 2008, as the base layer. With the signed site plan as the starting point: i. Show/label any modifications made to the site since that approval was granted in 2007; ii. Show/label (using different colors/symbology) any proposed improvements. Response: An electronic (AutoCAD) copy of the 2008 site plan is not available to be used as the starting point. However, a new sheet (SP-1.3) has been added to the plan set to show the modifications to the most recently approved site plan. b. The site plan should include a dimensional bulk requirements table. Response: A dimensional bulk requirements table has been added to the plan set. c. Clarify whether the proposed new self-storage building also includes office space. The Building Chart on sheet SP-1.1 says the proposed use of the building is “self-storage and office” but the floor plans on sheets FP-3.1 and FP-3.2 do not appear to indicate any office use. Response: The new self-storage building (Building 11) does not include office space. The Building Chart has been updated to remove reference to “office”. Page 35 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 3 d. Confirm the height of the building at both the north and south elevations. Response: The proposed height of Building 11 at both north and south elevations has been added to sheet FP-3.1 of the plan set. e. The outdoor contractor yards should be labelled on the site plan as #1 and #2 for ease of reference. Our comments will refer to the yard area across from the office as area #1, and the area at the south end of the site as area #2. Response: The outdoor contractor yards have been labelled as noted on the plan set. f. A drainage easement goes through the area labeled “Space for Excavators” within the proposed contractor’s yard area #1. The applicant should clarify whether they are proposing to relocate the easement. Response: The drainage easement is not being proposed to be relocated. A note has been added to the plan to indicate that any equipment placed over the drainage easement will be relocated if access to the easement is required. While the drainage easement exists there is no drainage infrastructure currently installed within it. g. The proposed contractor’s yard areas are located immediately adjacent to the access drive used by the public to navigate the storage facility site. The applicant should demonstrate how the storage area and the access drive will be separated to ensure public safety (signage, fencing, etc.). Response: See response to Comment 2, above. h. The applicant should demonstrate that emergency vehicles can still circulate around the site with the addition of the contractor’s yards. Response: See response to Comment 2, above. i. Clarify what surface treatment will be used in the contractor’s yard areas (eg stone, pavement). Response: For contractor yard #1 the surface treatment will be Gravel Stone (2” minus), for contractor yard #2 the surface treatment will be asphalt and Gravel Stone. j. Striping for all designated parking areas should be clearly delineated on the site plan. Response: Striping for all designated parking areas has been shown on the site plan. k. Sheet SP-1.2 indicates a retaining wall is proposed adjacent to the new pavement area just north of the proposed self-storage building. This, and any other retaining walls not previously approved by the Planning Board, should be clearly shown on the site plan, and renderings and details of all retaining walls should be included with the plan set. Response: The proposed new pavement area and corresponding retaining wall has been removed from the site plan. l. A refuse container should be shown on the site plan. Per §154 of the Town code, the dumpster area shall include a properly designed enclosure, and details of the enclosure shall be provided by the applicant. Response: There is a refuse container already at the site adjacent to Building #1 and has been added to the site plan. 4. Wetlands / Environmental: Page 36 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 4 a. The parcel appears to contain both NYS DEC wetlands and federal NWI wetlands. As per §179-5(A)(3) of the Town Code, the wetlands must be re-delineated as part of this project review. The full extent of the re-delineated wetlands should be shown on the site plan, along with any associated buffer areas. Response: The applicant had the limit of the wetlands flagged by their Wetland Consultant and Town has hired a consultant to verify those limits. The wetland limit and 100’ buffer have been shown on the site plan. b. Given the presence of state and federal wetlands on the site, the proposed project is an unlisted action under SEQR for which a coordinated review should be undertaken. Response: Noted. c. The SEAF indicates that the site is located in or adjacent to an area designated as sensitive for archeological sites on the NY State Historic Preservation Office (SHPO) archeological site inventory. The applicant should consult with SHPO to determine if any sensitive archeological sites would be affected by the proposed project. SHPO should be included on the SEQR circulation. Response: A letter was received from SHPO dated September 21, 2026 indicating that the project will not have an impact on any sensitive archeological sites. d. The SEAF indicates that the site is located in a floodplain. The applicant should address whether or not the proposed project would result in any impacts to floodplain areas. Response: No impact to the floodplain area is expected based on the proposed project. 5. Conservation Easement: Per Town Board Resolution 109-95, which changed the zoning district for this parcel from R-40 to M-1, the applicant was required to file a declaration of covenants and restrictions to include, in part, “…a conservation easement to the Town of Cortlandt covering the steep slopes and wetland areas on the subject property outside the developable area of the site…” It appears that this was never done. If the Planning Board approves the proposed Amended Site Development Plan, the filing of such declaration should be a requirement of the approval. In the interim, the area originally designated as "Conservation Easement” on the signed 2008 site plan should be reflected on the proposed plans, in place of the label on sheet SP-1.1 for “Park, Conservation & Flood Control Area”. In addition, TB Resolution 109-95 restricts the developable portion of the site to 3 acres and to a depth no greater than 100 feet from the center line of the access road. The 100-foot line and total area of disturbance should be included on the site plan. Response: Noted on the requirement for the filing of the declaration as a requirement of the approval for the Amended Site Plan. The label on SP-1.1 has been changed to “Conservation Easement”. We request that the addition of the 100-foot line and total area of disturbance to the site plan be a condition of Final Site Plan approval. Regarding developable area, while Town Board Resolution No. 109-95 identifies a developable area of “approximately 3 acres,” a later Planning Board Resolution for site plan approval properly identifies the developable area as 4.8 acres (See PB Resolution No. 1-07, adopted January 9, 2007, at p. 6), a figure consistent with the enclosed plans. 6. Contractor’s Yard Activities: a. If outdoor materials storage piles are proposed, the applicant should demonstrate how the piles will be contained on the site. Response: Outdoor material storage piles will not be proposed and any reference to outdoor material storage piles has been removed from the site plan. b. Maintenance of the various equipment is currently taking place on site, both within buildings and outside on paved areas. Moving forward, all vehicle/machine maintenance will be required to take place within a designated workshop; no outdoor repair of Page 37 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 5 equipment shall be permitted. As part of this application, the applicant shall provide a sitewide good housekeeping protocol, including but not limited to indoor/outdoor spill prevention, waste oil, solvent and similar fluids used in the maintenance of equipment stored and repaired onsite. Response: Sitewide Good Housekeeping Protocol. All vehicle and equipment maintenance involving oil, fuel, solvents, lubricants, coolant, or similar fluids will occur within the designated workshop on an impervious surface. Fluids and waste materials will be stored in properly labeled containers with secondary containment, and spill-response materials will be maintained on site. Any spills will be promptly contained and cleaned by trained personnel. Used oil, solvents, coolant, filters, batteries, and similar materials will be collected and disposed of through authorized recycling or waste-management services. No fluids, wash water, debris, or maintenance waste will be discharged to the ground, drainage facilities, or stormwater system. Vehicles and equipment stored outdoors will be periodically inspected for leaks, and any leaking equipment will be promptly moved to the workshop or otherwise contained. The site operator will conduct routine inspections to ensure proper housekeeping, waste management, and material storage practices are maintained. Employees performing maintenance activities will be trained in fluid handling, spill response, and waste-disposal procedures, and applicable records will be retained as required. These measures will ensure maintenance activities remain contained within the designated workshop and that maintenance-related materials and wastes are managed in a safe and environmentally responsible manner. 7. Notes: The applicant shall add the following notes to the site plan: a. The processing of materials is not permitted on the site. b. Areas not designated on the site plan for outdoor storage and contractor’s yard activities shall not be utilized as such. c. No outdoor repair of equipment shall occur. Equipment shall only be located in those areas delineated as “equipment parking and storage”. Response: The above referenced notes have been added to sheet SP-1.2 of the site plan. Referrals & Attachments: The subject application has been referred to the Planning Board’s consulting engineer (LaBella Associates); comments will by provided by separate memo. The application will also be referred to the Lake Mohegan Fire District, NYSDEC, US Army Corps of Engineers, and NYSHPO for their review and comment. The plan set and related documents were previously distributed to the Planning Board. Response: Noted. Page 38 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 6 Planning Board’s Consulting Engineer (LaBella Associates) Review Memo – Dated September 10, 2026 Administrative 1. LaBella performed a cursory review of the current site conditions to identify discrepancies between the adopted Resolution No.1-07, dated January 11, 2007 and approved Sheet 1 of 1 titled Site Plan of Additional Buildings – Cortlandt Self Storage Complex at Regina Avenue dated January 25, 2006 and last revised January 15, 2008, as prepared by Ralph Mastromonaco for the development plan. The following were noted: (Existing Site Issues) a. Access drive to the rear of buildings 6 and 7 (formerly identified as 1 and 2 on approved plan) was added. b. Multiple retaining walls were constructed to support the rear access drives to buildings 6 and 7 (formerly identified as 1 and 2 on approved master development plan). c. Parking was added to the southwest corner of building 6 (formerly identified as building 2 on the approved master development plan). d. Parking has been added to the west and south of building 5 (formerly identified as building E on the approved master development plan). e. Trailer storage in rear of building 8 (formerly identified as building E on the approved master development plan). f. Building 8 (formerly identified as building 3 on the approved master development plan) was shifted south from the original location. These items should be referenced For Planning Board consideration as part of the site plan approval for the new building. Response: See response to 3a under the Planning Memo. 2. Provide a removals plans identifying asphalt, structures, and utilities to be removed. Provide retaining walls calculations for sliding, overturning, and global stability for constructed walls over 3-ft on-site. Provide details for the associated site improvements. Response: Any infrastructure to be removed as has been identified on SP-1.1 and SP-1.2 of the plan set. Preparation of the requested retaining wall calculations is ongoing and will be provided under separate cover when completed. 3. All approvals must be received by regulatory agencies having jurisdiction prior to commencement of ANY construction activities. Response: Noted. 4. Per Chapter 259, a steep slope analysis and finding statement may be required. Response: a steep slope analysis and finding statement may have been required related to the previously proposed retaining wall and asphalt shown for Building 11 but that proposed work has been removed from the Site Plan so a steep slopes finding statement should not be required. 5. Per Chapter 179, a wetland finding statement may be required. Response: a wetland findings statement is being prepared and will be submitted under separate cover. 6. Firematic response comments are pending referral to DOTS – Code Enforcement and the Lake Mohegan Fire Department upon revision of the plans. Response: Noted. A response from the Lake Mohegan Fire Department has been obtained and will be submitted via the Town’s Open Gov Portal for this application. Page 39 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 7 These items should be noted in the proposed Site Development Plans and include an updated drainage analysis for the site. Response: Noted. Sheet SP-1.1 – Site Development Plan 1. Extend the water line easement to encompass the hydrant near building 9. 2. Provide a dimensional bulk table for the site, legend, and Town Signature Block on the plans. 3. Note the previous site changes to the site. Add callouts 4. Number all buildings. Response: An updated water line easement to include the hydrant near Building 9 has been shown on the site plan and a copy of the new easement description has been uploaded to the Town’s Open Gov Portal. Other items noted and add to the site plan. Sheet SP-1.2 - Site Development Plan 1. The Planning Board Chairman requested physical barrier (i.e. fence) around the contractor yard area Response: Physical Barrier (fence and wall) on 3 sides of the contractor yard has been noted on the site plan. The front of the respective contractor yards are not having a fence/barrier installed to accommodate access to the areas. 2. Clarify the necessity of 623 sf of asphalt and retaining wall shown to the north of the new building It appears a majority of the retaining wall and proposed asphalt (623 sf) to the north of the new building can be removed and a single 5-foot-wide access to the doors can be provided. Response: The proposed asphalt and retaining wall have been removed from the site plan and are no longer proposed for this project. 3. Identify points of door access to the proposed facility. Response: Access doors to the proposed facility have been added to the site plan. 4. Provide a note on the plan indicating no exterior equipment storage or container storage is permitted outside of the areas designated as contractor storage and no outdoor repair of equipment is permitted. Response: A note to this affect has been added to the plan to the site plan. Along with a note to indicate that parking of licensed vehicles outside of the contractor yards is permitted. 5. Show relocated sanitary force main, drainage pipe, and drainage structures, footing drains, as well as proposed drainage infrastructure (including roof leaders and means of conveyance). Response: This information been included on the revised site plan. 6. Provide a note on the plan that sanitary sewer force main and drainage piping to be relocated prior to building construction. Also note, sanitary force main is to be pressure tested following relocation in the presence of a Town of Cortlandt Department of Technical Services Representative and Applicant’s Engineer. A Professional Engineer shall provide a certification of said installation and testing to the Town. Response: We request that this note be a condition of Final Site Plan approval. 7. Provide additional capacity for the increase in impervious areas within the stormwater management basin compared to the original site plan. Note the basin shall be restabilized with topsoil, seed, and mulch. Response: We request that the additional capacity for the stormwater basin and corresponding restabilization note be a condition of Final Site Plan approval. Page 40 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 8 8. Please confirm if the area of total disturbance associated with the additional improvements identified in Administrative Comment 1 and the proposed project exceed the one acre threshold and thus require a SWPPP under the NYSDEC Redevelopment criteria. Response: The tabulated areas for total disturbance associated with the additional improvements is less than 1 acre and thus should not require a SWPPP under the NYSDEC Redevelopment criteria. 9. Sheet SP1.1 indicates material storage on-site but is not shown on Sheet SP-1.2. Material storage areas shall be shown along with mechanism of containment to prevent sediment runoff. Response: Material Storage is not proposed in the contractor yard’s and reference to it has been removed from the site plan. 10. Show not only spot elevations but proposed contours around the building. Response: Adequate spot elevations and contours for the proposed Building 11 have been shown on the site plan. 11. Provide new invert at drop inlet with rim 328.9 receiving the new 15-inch drainage pipe. Response: A proposed invert in the existing drop inlet for the new 15-inch drainage pipe has been shown. 12. It appears a low point is being created on the southern side of the building, and a catch basin will be required. Response: A low point is not being created. The area pitches from high to low towards the existing asphalt and a new catch basin in that area is not required. 13. Identify the surface area of the storage yards. Response: See response to 3i under the Planning Memo. 14. Number all buildings. Response: The site plan has been updated to include numbering off all buildings. 15. Add a note indicating the conservation easement shall be field staked by a NYS licensed surveyor prior to Building Permit Issuance. At no point shall the conservation easement be encroached upon. Response: A note to this affect has been added to the site plan. 16. The contractor’s yard extends over the drainage easement. If outdoor storage is permitted over the drainage easement it shall either be relocated elsewhere onsite, or sufficient notes outlining access and responsibility to relocate of the outdoor storage. Response: See response 3f of the Planning Memo. 17. Provide a safety plan on how equipment moves from one side of the site to the other without interfering with the customers accessing the storage buildings. (not going on plan) Response: The applicant proposes the following Equipment Movement Safety Plan a. Equipment will be moved between the designated contractor's yard areas in a controlled manner to avoid conflicts with customers accessing the self-storage buildings. The contractor's yard has operated on the site for an extended period without any known conflicts or safety incidents involving customer access. b. The following procedures will be maintained: c. Equipment will be limited, whenever practical, to periods of lower customer activity. Page 41 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 9 d. A trained employee or spotter will monitor the access drive and guide equipment when it is moved across customer circulation areas. e. Equipment operators will stop and yield to customers, pedestrians, and passenger vehicles at all times. f. Warning lights, audible alarms, cones, temporary signs, or barricades will be used when appropriate. g. Equipment will travel at a slow and controlled speed along designated routes. h. No equipment will be staged, parked, loaded, or unloaded within customer drive aisles, building entrances, fire lanes, or emergency-access routes. i. Customer access to the storage buildings will remain open and unobstructed. j. If customer traffic is present, equipment movement will be temporarily suspended until the route is clear. k. Employees responsible for moving equipment will be instructed in the site's circulation and safety procedures. 18. List the exact equipment proposed to be onsite in the contractor’s yard. Response: An exact equipment list can not be provided as the applicant’s need for contractor storage is variable. Representative equipment has been added to the site plan. 19. Clearly indicate employee vs customer parking. Response: Employees and customers are able to park in any open parking spots at the site. 20. Consider eliminating door locations on Sheet FP-3.1 and Sheet FP-3.2 in the front and rear of the building to eliminate the needs for stairs in the rear and retaining wall and ramp in the front. Otherwise show the necessary improvements for Planning Board review and consideration. Response: These door locations have been removed. 21. As indicated at the September Planning Board meeting, please add a note that no storage of aggregate material will take place within the contractor storage area. Response: A note to this affect has been added to the site plan. 22. Add the following Town Standard notes: a) All disturbed areas shall be 100% stabilized and planted prior to the issuance of a Certificate of Occupancy. b) The applicant shall submit an as-built foundation survey to the Town of Cortlandt prior to framing c) Prior to the backfilling of any storm water best management practice, DOTS shall be notified to perform an inspection. d) All proposed import fill must be tested and certified as unrestricted, suitable for residential use in accordance with Town Policy. Certification must be provided by a licensed professional. All certifications shall be addressed to Town’s Planning Board Engineer. All soil analytics and reports will be forwarded to the Town’s Planning Board Engineer for review and approval. e) Prior to acceptance of the road and drainage facilities, the Town will require a certification from a NYS Engineer that the completed site work and drainage improvements will not cause an adverse impact to adjoining or downstream properties. Page 42 Town of Cortlandt Planning Board September 23, 2026 Cortlandt Self-Storage, L.P. – Amended Site Plan page 10 f) Rock ripping will be used wherever possible. If blasting is required, it will require prior approval from the Town of Cortlandt and an air quality permit from the Westchester County Department of Health. g) There shall no processing of excavated materials by a rock crusher or similar equipment on-site. h) No retaining wall or foundation drains shall be discharged into the on-site drainage system. Response: These notes have been added to the site plan. Sheet CD-2.1 – Construction Details 1. Multiple details for sewer installation beneath pavement are provided. Select one and remove the others Response: The sewer installation details have been updated for consistency and clarity. 2. Driveway asphalt section differs from trench replacement details. Please clarify and provide consistent asphalt sections. Response: The asphalt section for trench replacement has have been updated for consistency and clarity. Should you have any questions or require any additional information from our office please don’t hesitate to contact us. Respectfully submitted, Patrick M. Bell, P.E. enclosures cc: Mark Giordano, Owner/Applicant File:Giordano-44 Regina Ave-Cortlandt-Site Plan-Letter-20260923 Page 43 JOHN A. LENTINI, Architect September 23, 2026 TOWN OF CORTLANDT Planning Department 1 Heady Street Cortlandt Manor, NY 10567 Att: Town of Cortlandt Planning Board Chairman Re: Nail Salon 3172 E. Main Street, PBCK-24-6, A-24-539 Reduced Scope submission Dear Chairman: Revised plans submitted indicate a reduced scope from the initial proposal filed 7/25/2024. We, hereby proposes no additional floor area. The request to permit a second floor addition has been abandoned due to an overwhelming resistance from Town Department of Technical Services. We hereby propose maintaining the existing structure foot print and altering the roof as illustrated for the primary purpose of installing Solar Cell Collectors. Other repairs and improvements are required to the basement and structure. The proposed use remains as a Beauty Parlor/ Nail Spa, B Occupancy The applicant has filed applications for connecting the sanitary sewers of the referenced site and the neighboring lot, 3176 E. Main Street, which is a multiple dwelling. Both lots are owned by the applicant, however, were acquired at different times and have separate deeds. An easement has been established for both lots to reach sanitary spurs provided by the neighboring property known as the Cortlandt Crossing at 3144 E. Main Street. It appears that a lack of approval for the new use for 3172 E. Main Street is preventing the sanitary connections for both sites. Page 44 9/23/2026 continued Aside from the trenching required for the sewer connections there is no proposed significant site disruption. The former parking in front of 3172 E. Main Street is discontinued. The remaining parking appears sufficient. I believe that the desire to re-build the roof is sufficient for the Town to require review by the Town’s Zoning Board of Appeals (ZBA). The existing side yard setback(s) are insufficient. We will repeat our request to be referred to the ZBA or to schedule a public hearing which ever is the appropriate sequence. I believe at some point the lead agency has to be identified if it hasn’t been already. Please be advised that the former owner/developer worked with the New York State Department of Transportation for approval of the current curb cut configuration that has worked well without incident for years. I believe that the former owner also negotiated the sanitary connections provided by the Cortlandt Crossing. We do not wish to physically alter Route 6 or the curb cuts and will provide an easement or agreement between the two properties that are in the same ownership, to the satisfaction of the Town’s Department of Technical Services. The configuration is unusual. In my professional opinion the traffic patterns do not pose any hazards and is safer than eliminating one of the three for the purpose of resembling homogeneity or separating parking areas. The Town has encouraged combining parking areas on other commercial sites on E. Main Street. Your review and consideration is greatly appreciated. Respectfully JOHN A. LENTINI ARCHITECT 2 of 2 Page 45 ' 4.94 26.0' 10.07' 30.0' 30.0' 30.0' 30.0' 4' 166.3' 33. 0 ' 10.0' 30. 30.0' 30.0' 3.6' 1 1.92' 7.92' Page 46 18" 12" 12" 12" 18" 18" Page 47 @ PROPOSED ARBORVITAES 12 FEET ON CENTER MOUNTED ADJUSTABLE XL22-80 LED LIGHT NEW LOCATION LUMINNARE SCHI SYMBOL laTy |TYPE|WATTS|ARRANGEMENT [TOTAL LAMP LUMENS | LLF | DESCRIBE « ) 9 LED Fe EAJADJUSTABLE | 65.457 - | 13,688, 100 | RAB XL22-80 #3172 EX. 1 STY FRAM PROPOSED. a, PROPOSED BEAUTY SHOP PARKING SIC SEC. 7231 DESIGN CRITERIA MAXMUM FOOT CANDLES (FC) PER SQUARE FOOT (PSF) Es ILLUMNANCE (FC) . A = AREA 1 FC = 1 LUMEN PSF PAKING AND WALK AREA_ 10,000 SF LIGHTED LANDSCAPE AREA 1000 SF LUMENS - E X A - | X L000 E - 110,000 HEIGHT 12” ABOVE TOP OF CONTAINER PAQUE IG DUMPSTER ENCLOSURE PERSPECTIVE PLO] PLAN SCALE I - 10° Oo" BOX exe TNs sures TOWN OF CORTLANDT SEC. 327-123 * REQUIRED LIGHTIONG UNDER NORMAL POWER CONDITIONS PER S 122821 “LIGHTING TO REMAIN ON DURING ALL. TIMES OF OCCUPANCY, ‘ALL MEANS OF EGRESS SHALL MAINTAIN LIGHTING AT THE SURFACE OF 1 FOOT- CANDLE (ll LUX) “LIGHTING AT EXIT DISCHARGE PER Iga823 ILLUMINATION NOT REQUIRED IF LIGHTING IS. NO LESS THAN | FOTTCANDLE (1 ILUX) * ALL EXITS TO COMPLY WITH 12285, EXIT TO LEAD TO A PUBLIC WAY. * ALL LIGHTING IMPROVEMENTS TO COMPLY WITH THE TOWN OF CORTLANOT. ZONING CODE CHAPTER 307. SEC. 307-123 “LIGHT FIXTURES TO'8E SELECTED AND. ARRANGED TO PREVENT GLARE, TO INSURE THE SAFETY OF PEDESTRIANS AND TO CONSERVE. ENERGY. * ALL NEW AND ANY UPGRADES 70 EXISTING LIGHTING SHALL MEET THE FULL STANQARDS PROVIDED IN THE QUTOOOR LIGHTING CODE, * PROHIBITED OUTDOOR LIGHTING ce] UP_LIGHTING, PROPOSED LIGHTING CANT CREATE SKY POLUTION bl EXTERNALLY LIT SIGNS, DISPLAY OR STRUCTURE. ¢) ROOF MOUNTED AREA LIGHTING od SEARCH. STROBE OR LASER LIGHTS e] MERCLRY VAPOR OR METAL HALIDE ARE PROHIBITED. ) UNSHIELDED FIXTURES ARE PROHIBITED. @) NEON LED TUBE OR ROPE LIGHTS PROHIBITED PER COE. * MAXIMUM LIGHTING LEVELS AS FOLLOWS =) PARKING LOTS, WALK WAYS AND BUILDING ENTRANCE, SHALL HAVE A MAXIMUM AVERAGE LEVEL, OF ONE FOOT CANDLE. b) UNIFORMITY RATIOS NOT LESS THAN 13 (33) PARKING AND TRAFFIC AREAS. Pri S/2nee ap Ea CLIENT MR/ CHEUNG LAM LOCATION 3172 E. MAIN STREET MOHEGAN LAKE, NY 12547 46-1-18. HC ZONE. 16.162 SF IPEEKSKILL SEWER DISTRICT prawn [oate 2/13/2026 [ov JE bx | SITE PLAN JOHN A. LENTIN | ARCHITECT 124 ALLAN STREET 04324 = "PBCK-24-6 A-24-539 EXPIRES 03/31/2026 Page 48 RIGHT SIDE ELEVATION So LEFT SIDE ELEVATION Pabst FRONT ELEVATION Page 49 TOWN OF CORTLANDT DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT Town Hall, 1 Heady Street Town Supervisor Cortlandt Manor, NY 10567 Richard H. Becker, MD Heather LaVarnway, CNU-A, AICP Main #: 914.734.1080 Director Town Board James F. Creighton Michelle Robbins, AICP Cristin Jacoby Robert Mayes Joyce C. White MEMORANDUM TO: Planning Board Members FROM: Heather LaVarnway, CNU-A, AICP, Director Michelle Robbins, AICP, Assistant Planner SUBJECT: PB 2024-4 Application of John Lentini on behalf of J Glamour Nails & Spa Inc., for Amended Site Plan approval for change of use and renovation of a former restaurant to a nail/beauty salon use, located at 3172 E. Main Street (US Route 6). Section 24.6, Block 1, Lot 18. DATE: September 28, 2026 The Planning Department reviewed the subject application consisting of: • 3-page Site Plan set for 3172 E. Main Street prepared by John A. Lentini, Architect dated 5/12/25 and last revised 6/9/26 • Elevations for “Beauty Shop” prepared by John A. Lentini, Architect dated 5/12/2025 and last revised 6/9/26 Project Description: The applicant is applying for a change of use and amended site plan to renovate the existing building formerly occupied by a restaurant. The applicant is proposing to change the roofline of the building by extending the peaked roof over the entire footprint of the structure and by modifying the roofline of the portico. The existing building footprint would not be changed. The site shares driveway access from Route 6 with the residential building on the adjacent parcel to the east. Upon review of the above items, we offer the following observations and comments: Additional Information Required: 1. The applicant shall provide the following additional information: A. Please update the architect seal and signature. The seal on the site plan shows an expiration date of 3/31/26. B. The site plan should indicate that it is an amended site plan and a change of use. C. The applicant should confirm that the proposed renovation would not result in additional building square footage. D. The applicant shall provide floor plans to reflect the proposed interior of the building. Nail/beauty stations, and other interior breakdowns of space, shall be clearly indicated on the floor plans; this will help inform expected parking needs. Floor plans shall be provided showing any basement and second story levels, if proposed. Page 50 E. Site-wide front, rear, and side yard setback lines shall be shown on the plan. The “Zoning Info” table on the site plan shows a 23.9 LF side setback. This dimension should be shown on the site plan. F. If a wall-mounted sign is proposed please show on the architectural elevations. If additional sign details are known, they should be provided as well. 2. The lighting information currently shown on the plot plan is insufficient. The applicant should demonstrate that there is adequate lighting in the parking areas. Per §307-12.3-E, the applicant shall provide a separate photometric plan with footcandle grid showing lighting levels throughout site, along with a luminaire schedule including color temperature and BUG rating, etc. Photometrics are typically procured in consultation with the lighting manufacturer based on the specific fixtures selected. Complete manufacturer’s cut sheets of each fixture shall also be provided, including details on which fixture specifications are proposed for this project. 3. The applicant shall provide a plant schedule indicating the number, type, and size at planting of all proposed plant materials. A key shall be included so that the locations of all proposed plant materials can be identified on the landscaping plan. A tree planting detail was provided but no new trees appear to be shown on the plan. 4. A site circulation plan shall be provided that illustrates how vehicles, particularly garbage and fire trucks, will maneuver the site. This parcel is within the Lake Mohegan Fire District. Site Layout: 5. As shown on the plans, the asphalt area between the front of the building and Route 6 appears to remain as-is. In order to prevent people from illegally parking in the front yard, which is too narrow to safely accommodate parking and two-way vehicle traffic a portion of this area closest to the building should be reclaimed for lawn/landscaping. 6. The proposed refuse container location/orientation at the rear of the parking lot is not easily accessible if there are vehicles parked in the adjacent parking spaces. The applicant shall relocate/reorient the refuse container to eliminate conflicts with parked vehicles and allow a garbage truck to access the dumpster and easily maneuver around the site. 7. Per §154 of the Town code, the dumpster area shall include a properly designed enclosure. Although some details of the enclosure were provided additional details such as height of the enclosure and proposed materials shall also be provided. Parking & Traffic: 8. The commercial and adjacent residential parking areas currently flow together without delineation, which creates the potential for conflicts and safety issues between the intermingled traffic. The Planning Board may want to consider requiring a fence, safety bollards, or some other type of separation along a portion of the lot line between the parking area of the commercial property and the patio and rear yard of the residential property to improve safety and ensure privacy for the residential use. 9. The applicant shall ensure that all ADA accessible parking spaces are properly sized, striped, and signed. The ADA space appears to be narrower and longer than the adjacent parking spaces. 10. Bollards and what appear to be stairs are shown at the door located on the east side of the building on Sheet S-1. The applicant should confirm that proper internal vehicular access and aisle width is maintained and that the proposed bollards and stairs do not interfere in site circulation or result in pedestrians entering/exiting the building directly into the internal traffic lane. PB2024-4 Planning Review Memo #2 | Page 2 Page 51 Architecture: 11. The applicant shall provide additional details about the proposed building design and materials. The application will need to be referred to the Architectural Review Council (ARC). cc: Dr. Richard Becker, Town Supervisor James Creighton, Town Board Liaison Michael Cunningham, Esq., Deputy Town Attorney Michael Preziosi, P.E., DOTS Catherine Brosnan, P.E., DOTS Wendy Talio, CAC John Lentini, R.A. PB2024-4 Planning Review Memo #2 | Page 3 Page 52 September 23, 2026 Stephen Kessler, Chairman Town of Cortlandt Planning Board Town Hall, 1 Heady Street Cortlandt Manor, NY 10567 Re: Amended Site Plan KRD Properties LLC dba Hudson Valley Motorcycles 2108 Albany Post Road Dear Chairman Kessler and Members of the Planning Board: Find enclosed the following information for the above-referenced Project: 1. Planning Board Application fees of $500 2. Planning Board Application (via OpenGov) 3. 2 copies of the Adjoining Property Owners List 4. 2 copies of the Short Environmental Assessment Form 5. 2 copies of the Site Plan, full size, 7 copies at 11”x17” 6. 2 copies of the Architectural Plan, full size, 7 copies at 11:x17” 7. 2 copies of the site photos 8. 1 copy of the signed purchase contract PROJECT NARRATIVE This office has been retained by the Applicant to seek Amended Site Plan Approval from the Planning Board. The project was recently operating as a manufacturing facility which is now proposed to operate the Applicants business. The project site will be the Headquarters for Hudson Valley Motorcycles. The project site is fully developed with an existing one-story, 24,650 square foot concrete and steel building, paved parking areas, existing access onto Albany Post Road, existing utility connections and septic system. The proposed use is permitted in the HC-9A Zoning District and the Town Code Enforcement office determined that approval is required from the Planning Board for the Change in Use. The building interior will be modified to include two separate showrooms, service areas, and a parts department. There is virtually no land disturbance except for the creation of three new gravel parking spaces. All existing building coverages and setbacks will remain. Parking requirements for the prior manufacturing use, per code, required 62 parking spaces. Per Town Code Chapter 307 Article VIII , the new interior layout requires 61 parking spaces, a number which cannot be achieved nor does the applicant need that many spaces. There are 21 spaces presently and by adding three new gravel spaces and restriping in front of the refuse enclosure, there is approximately 27 parking spaces. Page 53 Town of Cortlandt Planning Board September 23, 2026 2108 Albany Post Road page 2 of 2 The business has 12 employees, 2 principals and an estimated daily visit of 5 customers. There is ample parking on site for the successful operation of the business and therefore the Applicant is respectfully requesting parking space relief from 61 to 27 parking spaces. In addition, the building front face is obscured from Albany Post Road due to a row of trees and vegetation along the frontage of the site. It is noted that the trees are generally in fair to poor condition and we are proposing to remove 11 trees. The trees will be replaced with a new row of native deciduous trees, a total of 12 trees are to be planted. We respectfully request placement of the application on the Planning Board’s October meeting agenda for consideration. Should you have any questions or require additional information please contact me at the above number. Thank you for your time and consideration in this matter. Respectfully submitted, Cronin Engineering cc: Rich Alexander via email w/ encl. alexander-2108 albany post road-pb-amended site plan-initial submission-ks-20260923 Page 54 Short Environmental Assessment Form Part 1 - Project Information Instructions for Completi Part 1 — Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1 — Project and Sponsor Information Name of Action or Project: Site Plan for 2108 Albany Post Road Project Location (describe, and attach a location map): 2108 Albany Post Road Brief Description of Proposed Action: A Change in Use from a manufacturing business to a motor cycle shop which includes a showroom, storage area, office and repair shop. Name of Applicant or Sponsor: <= Address: 39 Arlo Lane City/PO: State: Zip Code: Cortlandt Manor NY 10567 1. Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, administrative rule, or regulation? NO YES If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that [ | NO may be affected in the municipality and proceed to Part 2. If No, continue to question 2. 2. Does the proposed action require a permit, approval or funding from any other government Agency? If Yes, list agency(s) name and permit or approval: Planning Board 3. a. Total acreage of the site of the proposed action? 1.37 acres b. Total acreage to be physically disturbed? 0.025 acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? 1.37 acres 4. Check all land uses that occur on, are adjoining or near the proposed action: Urban [[] Rural (non-agriculture) [1 Industrial [J] Commercial [J Residential (suburban) CO Forest (1) Agriculture CO Aquatic [1] Other(Specify): CD Parkland Page 1 of 3 SEAF 2026 Page 55 5. Is the proposed action, a. A permitted use under the zoning regulations? b. Consistent with the adopted comprehensive plan? OL é 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? 7. Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? Name:Hudson River, Reason:Exceptional or unique character, Agency:Westchester If Yes, identify: County, Date:1-31-90 8. a. Will the proposed action result in a substantial increase in traffic above present levels? b. Are public transportation services available at or near the site of the proposed action? c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed action? I4\O|4|/O 4 8 § 9. Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: | 10. Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: 11. Will the proposed action connect to existing wastewater utilities? NO | YES If No, describe method for providing wastewater treatment: Existing on site subsurface wastewater treatment system 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district NO | YES which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? J 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: NO Ole Page 2 of 3 SEAF 2026 Page 56 14. Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply: O Shoreline Forest [[] Agricultural/grasslands [1] Early mid-successional OWetland © Urban fi Suburban 15. Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered? 16. Is the project site located in the 100-year or 500-year flood plain? 17. Will the proposed action create storm water discharge, either from point or non-point sources?If Yes, a. Will storm water discharges flow to adjacent properties? b. Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: Existing drainage patterns will remain. 18. Does the proposed action include construction or other activities that would result in the impoundment of water NO | YES or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment: Wd | LJ 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste NO | YES management facility? If Yes, describe: Wd) LI 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or NO | YES completed) for hazardous waste? If Yes, describe: Wd} LJ NO | YES 21. Is the project located within, or within % mile of, a disadvantaged community? l Y ] If No, could impacts from the project affect a disadvantaged community? If Yes to either question in 21, answer the following question. a. Identify the potential pollution impacts of the project, either direct or indirect, that may occur within the disadvantaged community (e.g., wastewater discharges, air emissions, noise, odors, solid or hazardous waste generation or management): potential noise impacts I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponsor/name:_Cronin Engineering Date: September 23, 2026 Signature: | ll Title: Project Manager Page 3 of 3 SEAF 2026 Page 57 EAF Mapper Summary Report Monday, September 21, 2026 9:19 AM Boney 54°8-3-42 fech o 54.8-3-49 54.12-3-2 4.12-3- th a 54.8-2-32 2 54.8-2-34 54.8-2-30 Disclaimer: The EAF Mapper is a screening tool intended to assist project sponsors and reviewing agencies in preparing an environmental assessment form (EAF). Not all questions asked in the EAF are answered by the EAF Mapper. Additional information on any EAF question can be obtained by consulting the EAF Workbooks. Although the EAF Mapper provides the most up-to-date digital data available to DEC, you may also need to contact local or other data sources to confirm data provided by the Mapper or to obtain data not provided by the Mapper. 54.8-2-26 94.8-2:29 Sound: | prtchvile , Bare 4 r 1 . Kingston { guid Pi Vompont » 4 Toronto =. ‘0 j ~ JHat ffamilfon Rochester oF \Bultale Hew Yor Part 1 / Question 7 [Critical Environmental Area] Part 1 / Question 7 [Critical Environmental Area - Identify] Part 1 / Question 12a [National or State Register of Historic Places or State Eligible Sites] Part 1 / Question 12b [Archeological Sites] Part 1 / Question 13a [Wetlands or Other Regulated Waterbodies] Part 1 / Question 15 [Threatened or Endangered Animal] Part 1 / Question 16 [100 or 500 Year Floodplain] Part 1 / Question 20 [Remediation Site] Part 1 / Question 21 [Disadvantaged Community] Yes Name:Hudson River, Reason:Exceptional or unique character, Agency:Westchester County, Date:1-31-90 No Yes Yes - Digital mapping information on local, New York State, and federal wetlands and waterbodies is known to be incomplete. Refer to the EAF Workbook. No No No Yes Short Environmental Assessment Form - EAF Mapper Summary Report 1 Page 58 2108 Albany Post Road September 23, 2026 Page 59 Page 60 UNAUTHORIZED ALTERATION TO A MAP GEARING A LICENSED PROFESSIONAL LAND SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7209, SUBDIVISION 2, OF THE NEW YORK STATE EDUCATION LAW. THE CERTIFICATION 1S NOT AN EXPRESS OR IMPLIED WARRANTY OR GUARANTEE, IT IS PURELY A STATEMENT OF PROFESSIONAL OPINION BASED ON KNOWLEDGE, INFORMATION AND BELIEF, BASED ON EXISTING FIELD EVIDENCE AND DOCUMENTARY EVIDENCE AVAILABLE, CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. PLAN PREPARED PURSUANT TO SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. SUBJECT TO THE FINDINGS OF AN UP TO DATE TITLE SEARCH. UNLESS THE SURVEYOR'S: ORIGINAL SIGNATURE AND SEAL APPEARS RAISED ON THIS MAP, IT SHOULD NOT BE CONSIDERED [A TRUE AND CORRECT COPY OF THE SURVEYOR'S ORIGINAL WORK AND OPINION, GaRBAGE \ N/F SANGRO SBL 54.12-3-2 LEGEND © IRON PIPE © IRON ROD —& CATCH BASIN 39 FIRE HYDRANT ELECTRIC NETER ELECTRIC MANHOLE TELEPHONE MANHOLE GAS VALVE UTILITY POLE. WITH RISER UTITY POLE UTILITY POLE WITH LIGHT MAILBOX ea VENT & OIL FILL To — POST SS0S0C0000080000, FIRE DEPARTMENT CONNECTION = 52 SIGN rs © BOLLARD fooedsraxrcoea FENCED ENCLOSURE N/F SANGRO SBL 54.12-3-2 N/F CCC PROPERTY MANAGEMENT INC. CNTRL# 582403373 SBL 54.12-3-5 PROPERTY LINE POB EASEMENT EOA WOOD/VINYL FENCE Ne. OVERHEAD WIRES PL STONE WALL SRW MINOR CONTOURS cRW MAJOR CONTOURS cc cMP POINT OF BEGINNING EDGE OF ASPHALT CONCRETE PROPERY LINE STONE RETAINING WALL CONCRETE RETAINING WALL CONCRETE CURB CORRUGATED METAL PIPE 59847.57204SQFT. SBL 54.12-3-3 N/E_FIONA CNTRLg 612353454 SBL 54.12-3-4 'S26114°00"E 65.02" '$23'27'50"E LOCUS MAP (N.T.S.) SURVEY NOTES 1, THIS PLAN WAS PREPARED FROM AN ON THE GROUND FIELD SURVEY CONDUCTED BY RLS (ON MAY 30, 2025 AND ON THE FOLLOWING DATUM— MERIDIAN: L9443 PSO HORIZONTAL: ASSUMED VERTICAL: SCALED AS PER SITE DEVELOPMENT PLAN PREPARED BY CRONIN ENGINEERING FOR’ SEVERINO SANGRO. 2, REFERENCES ‘STREET NAMES, R.O.W. WDTHS, PROPERTY IDENTIFICATION NUMBERS, OWNER NAMES, EASEMENTS, AND ANY ADOITONAL INFORMATION SHOWN HEREON ARE REFERENCED FROM ‘THE FOLLOWING MAPS AND DOCUMENTS— A. LAND CONVEYED TO NIMUS ASSOCIATES BY DEED BOOK 9443 PAGE 50, FILED IN THE WESTCHESTER CO. CLERKS OFFICE ON JANUARY 9, 1989, 3. THE SURVEYED PROPERTY IS SUBJECT BUT NOT LIMITED TO THE INFORMATION SHOWN HEREON. ALL INFORMATION THAT MAY AFFECT THE QUALITY OF TITLE TO BOTH THE ‘SUBJECT AND ADJOINING PARCELS SHOULD BE VERIFIED BY AND ACCURATE AND CURRENT TVTLE REPORT. 4. THE LOCATION OF THE UTILITIES AS SHOWN HEREON HAVE BEEN COMPILED FROM VISIBLE ‘STRUCTURES AND INFORMATION OBTAINED FROM VARIOUS SOURCES, THE ACTUAL LOCATION (GF ALL UTILITIES AND UNDERGROUND STRUCTURES SHALL BE CONSIDERED APPROXIMATE AND SHALL BE VERIFIED BY THE OWNER PRIOR TO ANY CONSTRUCTION, ‘5. WETLANDS, ENVIRONMENTAL ANO/OR HAZARDOUS MATERIALS LOCATION, IF ANY, NOT COVERED UNDER THIS CONTRACT. [OR] WERE LOCATED AS MARKED AT'THE TME OF THE ‘SURVEY. 6, UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND 'SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7208, SUBDMSION 2, OF THE NEW YORK ‘STATE EDUCATION LAW. 7. CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ‘ACCORDANCE WITH THE EXISTING CODE OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. THIS PLAN NOT VALID UNLESS ORIGINAL STAMP AND SIGNATURE OF A LICENSED SURVEYOR ARE LOCATED HEREON, 8 OFFSETS OR DIMENSIONS FROM THE PROPERTY LINES TO STRUCTURES ARE SURVEY REFERENCES ONLY, AND NOT INTENDED TO MONUMENT THE PROPERTY LINES, NOR ARE ‘THEY TO BE USED IN OR GUIDE CONSTRUCTION OF ANY TYPE, PROPERTY SURVEY 2108 ALBANY POST ROAD TOWN OF CORTLANDT, NEW YORK PREPARED FOR CHUCK CARTALEMI ROWAN LAND SURVEYING, PLLC 330 OLD ALBANY POST ROAD GARRISON, NY_10524 P| Ss Drawn By PR Date Job No. Surveyed By PR JUNE 1, 2025 | 025-060 Scale Sheet No. 1" 40° 10F 1 Page 61 SITE SPECIFIC NOTES 1. PARCEL TAX MAP DESIGNATION: SECTION: 54.12, BLOCK: 3, LOT(S): 3 2. TOTAL AREA OF EXISTING LOT: 59,847.57 SQ. FT. (1.37 ACRES). APPROXIMATE LOCATION OF 3. SURVEY AND TOPOGRAPHICAL INFORMATION SHOWN HEREON IS BASED ON A SURVEY PREPARED BY ROWAN LAND SURVEYING, PLLC, ENTITLED "PROPERTY SURVEY, 2108 ALBANY POST ROAD, TOWN OF CORTLANDT, NEW YORK, PREPARED FOR CHUCK CARTALEMI," DATED JUNE 1, 2025. EXISTING 8"Ø WATER MAIN 4. PARCEL IS LOCATED IN THE TOWN OF CORTLANDT HC/9A (HIGHWAY COMMERCIAL/MULTI-FAMILY) ZONING DISTRICT. 5. PARCEL IS LOCATED IN THE HUDSON RIVER WATERSHED. SITE ENGINEER'S NOTES 1. THERE SHALL BE NO MODIFICATION TO ANY ASPECT OF THIS PLAN WITHOUT CONTACTING THE DESIGN ENGINEER. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL CODES, RULES & REGULATIONS. 3. THIS PLAN WAS PREPARED FOR THE PURPOSE OF OBTAINING SITE PLAN APPROVAL FROM THE CITY OF PEEKSKILL PLANNING COMMISSION AND A BUILDING PERMIT. NO REPRESENTATION TO THE SUB-SURFACE SOIL CONDITIONS ON THIS LOT ARE MADE OR IMPLIED BY THIS PLAN. IMPROVEMENTS SHOWN ARE FOR SCHEMATIC PURPOSES. 4. IT IS THE OWNERS RESPONSIBILITY TO INSURE THAT ALL IMPROVEMENTS ARE PLACED ON MATERIAL WITH A SUITABLE BEARING CAPACITY. 5. CONTRACTOR TO VERIFY DEPTH & LOCATION OF ALL UTILITIES INCLUDING WATER, SEWER, DRAINAGE, GAS, TELEPHONE, ELECTRIC & CABLE, ON SITE AND OFF SITE, AS NECESSARY PRIOR TO START OF WORK. 6. PROPOSED BUILDING DESIGNED BY OTHERS. 6 3 LOCATION MAP SCALE: 1" = 300' TELECOM SPECIAL NOTES: WITNESS POST 1. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE MEANS AND METHODS NEEDED TO PERFORM THE CONSTRUCTION/EXCAVATION, ET AL, EXISTING WALL (11) TREES TO BE LIGHTS OPERATIONS SHOWN HEREON. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A SAFE WORKING ENVIRONMENT AND PROVIDE THE MEANS AND METHODS TO PERFORM THE NECESSARY TASKS. NOTHING ON THESE PLANS SHALL OBLIGATE THE DESIGN ENGINEER AS TO THE MEANS AND REMOVED (TYP) METHODS TO PERFORM THE TASKS ASSOCIATED WITH THE APPROVED DESIGN PLANS. THOSE OBLIGATIONS AT ALL TIMES REMAIN WITH THE CONTRACTOR(S). 2. THESE DRAWINGS MAY OR MAY NOT TRULY REFLECT EXISTING CONDITIONS AND THAT SUCH INFORMATION IS INCLUDED ON THE ASSUMPTION THAT IT MAY PROVIDE NEW STRIPES IN ING BE OF INTEREST TO THE CONTRACTOR, BUT THE ENGINEER, OWNER AND THEIR CONSULTANTS DO NOT ASSUME RESPONSIBILITY FOR ITS ACCURACY OR FRONT OF ENCLOSURE AD LO OCK COMPLETENESS. THE CONTRACTOR HAS AN OBLIGATION TO DETERMINE FOR ITSELF THE TRUE NATURE OF EXISTING CONDITIONS. D MP RA WN DEMOLITION NOTES D O EXISTING CONCRETE PAD AND ENCLOSURE TO REMAIN 1. NO WORK SHALL BE PERFORMED UNTIL A PERMIT IS ISSUED BY THE CITY OF CORTLANDT. 2. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. DRY WELL 3. MATERIAL MAY BE RECYCLED/CRUSHED ON SITE AND USED FOR A SUBBASE AS DIRECTED BY ENGINEER. 4. EROSION AND SEDIMENT CONTROLS SHALL BE INSTALLED IN PLACE AS DIRECTED BY ENGINEER PRIOR TO DEMOLITION WORK. EXISTING HANDICAP SPACE 5. AREAS WHERE ASPHALT/CONCRETE REMOVAL OCCUR SHALL BE STABILIZED WITH A LAYER OF 1" CRUSHED STONE. 3 EXISTING 6. DUST CONTROL SHALL BE PROVIDED DURING DEMOLITION OF THE SITE. WALL LIGHT 20 20 0 10 REFERENCE NOTES: SCALE: 1" = 20 FT. 1. REFERENCE IS MADE TO A SET OF PLANS PREPARED BY JOSEPH G THOMPSON ARCHITECT, PLLC DATED SEPTEMBER 23, 2026. OWNER/APPLICANT SE PTI CA ENGINEER'S NOTES TO OWNER AND/OR CONTRACTOR KRD PROPERTIES, LLC RE P.O. BOX 891 EXISTING A 1. A PRE-CONSTRUCTION SITE INSPECTION WITH THE DESIGN ENGINEER IS REQUIRED WITH THE OWNER AND CONTRACTOR PRESENT TO CONFIRM THE 8 CONSTRUCTION PROCEDURE. FORT MONTGOMERY, NY 10922 2. THERE SHALL BE NO MODIFICATION TO ANY ASPECT OF THIS PLAN WITHOUT FIRST CONTACTING CRONIN ENGINEERING. FOR APPROVAL. 1-STORY DBA HUDSON VALLEY MOTORCYCLE 3. PRIOR TO ANY EXCAVATION, THE OWNER AND/OR CONTRACTOR SHALL CALL THE UNDERGROUND LINE LOCATION SERVICE (CODE 53) AT (800)-962-7962. FOR MORE INFORMATION, VISIT WWW.DIGSAFELYNEWYORK.COM. CONCRETE/ 4. EROSION & SEDIMENT CONTROL MEASURES AS SHOWN IN THIS PLAN SET SHALL BE IN PLACE PRIOR TO THE COMMENCEMENT OF ANY SITE WORK. IF UNFORESEEN FIELD CONDITIONS ARE ENCOUNTERED WHICH PROHIBIT THE INSTALLATION OF CERTAIN EROSION & SEDIMENT CONTROL MEASURES AS SHOWN, STEEL · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS IT SHALL BE THE OWNER AND/OR CONTRACTOR'S RESPONSIBILITY TO CONTACT THE DESIGN ENGINEER IMMEDIATELY TO DISCUSS ALTERNATIVE METHODS. IT EXISTING SHALL BE THE OWNER AND/OR CONTRACTOR'S RESPONSIBILITY TO ENSURE THE INTEGRITY OF ALL EROSION & SEDIMENT CONTROL MEASURES AT ALL TIMES THROUGHOUT THE DURATION OF THE PROJECT. BUILDING WALL LIGHT ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS 8 SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE 5. THE DESIGN ENGINEER MAKES NO REPRESENTATIONS OR CERTIFICATIONS AS TO THE INTEGRITY, LOCATION OR EXISTENCE OF SUBSURFACE STRUCTURES OR DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. SOIL CONDITIONS WITH RESPECT TO STABILITY AND SUITABILITY FOR THE INTENDED PURPOSE. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. CONTRACTOR TO VERIFY ALL SUBSURFACE CONDITIONS AND INSURE THAT ALL IMPROVEMENTS ARE PLACED ON MATERIAL WITH A SUITABLE BEARING CAPACITY. REVISIONS 6. THE DESIGN ENGINEER MAKES NO REPRESENTATION OR CERTIFICATIONS AS TO THE QUANTITY OF MATERIAL NEEDED OR TO BE REMOVED FOR THE SUCCESSFUL CONSTRUCTION OF THE PROJECT. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO VERIFY THE QUANTITY OF MATERIAL NEEDED OR TO BE REMOVED TO SUCCESSFULLY CONSTRUCT THE PROJECT. 7. IN THE EVENT THAT FIELD CONDITIONS ARE DIFFERENT THAN WHAT IS PRESENTED IN THIS PLAN SET, IT IS THE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO NOTIFY THE DESIGN ENGINEER. PRIOR TO CONTINUING WITH ANY FURTHER SITE WORK. 8. IF UNFORESEEN SUBSURFACE CONDITIONS ARE ENCOUNTERED (I.E. ROCK, GROUNDWATER, ETC.), THE OWNER AND/OR CONTRACTOR SHALL STOP WORK AND NOTIFY CRONIN ENGINEERING. ALL NECESSARY MODIFICATIONS OR CHANGES SHALL BE DISCUSSED WITH AND APPROVED BY THE DESIGN ENGINEER PRIOR TO CONTINUING WITH ANY FURTHER SITE WORK. FURTHERMORE, THE OWNER AND/OR CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS IF BLASTING IS REQUIRED. # REASON DATE 9. IT IS THE OWNER AND/OR CONTRACTOR'S SOLE RESPONSIBILITY TO FOLLOW OSHA, NYS AND ANY OTHER APPLICABLE CODES OR REQUIREMENTS THROUGHOUT THE DURATION OF THE PROJECT. THIS INCLUDES BUT IS NOT LIMITED TO PROVIDING ADEQUATE BRACING AND GUARANTEEING THE STABILITY MUNICIPAL TAX IDENTIFICATION: OF EXCAVATIONS AND OTHER VICINITY STRUCTURES. APPROXIMATE SECTION: 54.12 10. THE DESIGN ENGINEER MAKES NO REPRESENTATION AS TO THE QUALITY (I.E. CONTAMINATION), IF ANY, OF THE SOILS ON THIS SITE. THE OWNER AND/OR CONTRACTOR ARE RESPONSIBLE TO CONDUCT ANY AND ALL TESTING AS MAY BE REQUIRED TO ENSURE THE SITE HAS NO CONTAMINATED SOILS. LOCATION BLOCK: 3 OF 11. THE DESIGN ENGINEER MAKES NO REPRESENTATION AS TO THE SOIL BEARING CAPACITY OF THE SOILS ON SITE. THE OWNER AND/OR ARCHITECT ARE LOT: 3 RESPONSIBLE TO CONDUCT ANY AND ALL TESTING AS MAY BE REQUIRED TO ENSURE THE CONSTRUCTION OF THE FOUNDATION MEETS THE REQUIREMENTS WATER EXISTING OF THE NEW YORK STATE BUILDING CODE AND THE BUILDING CODE OF THE CITY OF PEEKSKILL. FOUNDATION DESIGN IS NOT PROVIDED BY THIS OFFICE AND IS THE RESPONSIBILITY OF THE OWNER/ARCHITECT/BUILDER. WALL LIGHT SERVICE SUBLOT: ----- DRAWN BY: AB/ JC 12. THE OWNER/BUILDER/ARCHITECT ARE RESPONSIBLE TO ENSURE THAT THE BUILDING FOUNDATION MEETS ALL CITY CODES AND THE NEW YORK STATE BUILDING CODE. IF UNSUITABLE MATERIAL IS ENCOUNTERED, THE OWNER SHALL MAKE PROVISIONS (I.E. DEEPER FOOTING, SPREAD FOOTING, GRADE BEAMS, CHECKED: JCA/PMB PILES, ETC.) AS NECESSARY TO ENSURE A CODE COMPLIANT FOUNDATION TO THE SATISFACTION OF THE TOWN OF CORTLNDT DEPARTENT OF TECHNICAL SERVICES. PROJECT: ALEXANDER-2108 ALBANY DATE: SEPTEMBER 23, 2026 PATRICK M. BELL, P.E. JOB #: 260812 SURVEY LEGEND ZONING MAP MUNICIPAL APPROVAL LICENSE #087679 C N N THE DEPARTMENT HEAD SIGNATURES INDICATE THAT THIS DRAWING OR SET OF DRAWINGS IS CONSISTENT WITH THE PLANNING BOARD RESOLUTION OF APPROVAL AND WITH THE GENERAL REQUIREMENTS AND POLICIES OF THE TOWN OF CORTLANDT FOR WHICH THE DEPARTMENT HEAD IS RESPONSIBLE. THE PROJECT DESIGN INCLUDING ALL PUBLIC HEALTH AND SAFETY APPROXIMATE TREE LINE CONSIDERATIONS ARE SOLELY THE RESPONSIBILITY OF THE DESIGN PROFESSIONAL WHO HAS M-1 SIGNED AND SEALED THE DRAWINGS. N N N NAL N N N C N L N SITE REVIEWED BY THE DEPARTMENT OF ENVIRONMENTAL SERVICES: (914) 736-3664 HC/9A R-15 DIRECTOR DATE 39 Arlo Lane REVIEWED BY THE DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT: Cortlandt Manor, New York 10567 DIRECTOR DATE R-160 EXISTING CONDITIONS REVIEWED BY THE PLANNING BOARD ENGINEER: ENGINEER DATE SITE DEVELOPMENT PLAN ZONING MAP SCALE: 1" = 500' FOR APPROVED BY RESOLUTION NO. OF THE PLANNING BOARD OF THE TOWN OF CORTLANDT, NEW YORK ON THE DAY OF , 2026, SUBJECT TO ALL REQUIREMENTS AND CONDITIONS OF SAID RESOLUTION. ANY CHANGE, ERASURE, MODIFICATION OR REVISION IN THIS PLAT OR SITE 2108 ALBANY POST ROAD LIST OF DRAWINGS DEVELOPMENT PLAN, AFTER THE ABOVE DATE, SHALL VOID THIS APPROVAL. SIGNED THIS DAY OF , 2026 BY: SHEET TITLE SHEET NUMBER TITLE ISSUE DATE LAST REVISED LOCATION: EX-1.1 1 OF 3 EXISTING CONDITIONS SEPTEMBER 23, 2026 - 2108 ALBANY POST ROAD SP-1.1 2 OF 3 SITE DEVELOPMENT PLAN SEPTEMBER 23, 2026 - CHAIRMAN OF THE PLANNING BOARD TOWN OF CORTLANDT, NEW YORK CHRISTOPHER GROSS, P.E., DIRECTOR DEPARTMENT OF ENVIRONMENTAL SERVICES SP-1.2 3 OF 3 CONSTRUCTION DETAILS SEPTEMBER 23, 2026 - HEATHER LAVARNWAY, CNU-A, AICP, DIRECTOR, DEPT. OF PLANNING & COMMUNITY DEVELOPMENT PLANNING BOARD CONSULTING ENGINEER SHEET 1 OF 3 EX-1.1 Page 62 ZONING DATA CHART - HC/9A (HIGHWAY COMMERCIAL/MULTI-FAMILY) MINIMUM MINIMUM MAXIMUM FRONT SIDE REAR MAXIMUM MINIMUM LOT DESCRIPTION LOT AREA LOT WIDTH HEIGHT YARD YARD YARD BUILDING LANDSCAPE (SQ FT) (FEET) (STORIES / FT) (FT) (FT) (FT) COVERAGE (%) COVERAGE (%) POSSIBLE MOTORCYCLE AND SERVICE DEPOSIT MINIMUM REQUIRED 20,000 100 2 12 / 35 30 30 30 25% 30% EXISTING 59,847.57 177 1 / < 35 30.8 *7.6 84 *41% 41.8% SITE *PRE-EXISTING NON-CONFORMING CONDITION PARKING REQUIREMENTS Use Parking Requirements Quantity Spaces Required Showroom 6 3 Storage EXISTING TELECOM WITNESS LOCATION MAP SCALE: 1" = 300' WALL Workshop LIGHTS POST Office ING Total AD LO OCK D MP RA WN D O IMMEDIATE PRIOR USE PURSUANT TO SECTION 307-29 OF THE TOWN CODE; "Manufacturing Facility" 1 per 400 square feet of Gross Floor Area" * EXISTING GROSS FLOOR SPACE = 24,890 SF/400 SF = ~62 SPACES DRY WELL PROPOSED USE -EXISTING SPACES ON SITE = 27 SPACES 1 EXISTING REFUSE ENCLOSURE TO REMAIN, RELOCATE FIRE -PROPOSED PARKING REQUEST = 61 SPACES TO BE REPURPOSED TO HOUSE 2-3 YARD EXISTING WALL LIGHT DEPARTMENT -RELIEF SOUGHT FROM PLANNING BOARD = 34 SPACES CONTAINERS AND OUTDOOR STORM CONNECTION APPROXIMATE LOCATION OF WATER SERVICE EXISTING CONCRETE PAD TO REMAIN 20 0 10 20 SCALE: 1" = 20 FT. SE PTI OWNER/APPLICANT CA RE CURB EXISTING A 8 CONCRETE SIDEWALK KRD PROPERTIES, LLC 1-STORY P.O. BOX 891 FORT MONTGOMERY, NY 10922 CONCRETE/ DBA HUDSON VALLEY MOTORCYCLE STEEL EXISTING BUILDING WALL LIGHT · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS 8 UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ST ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE 3 DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. SILT FENCE · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. REVISIONS CNC. PAD & FENCED GARBAGE ENCLOSURE PROPOSED 3 NEW GRAVEL PARKING # REASON DATE MUNICIPAL TAX IDENTIFICATION: SECTION: 54.12 IMPERVIOUS AREAS EXISTING BLOCK: 3 WALL LIGHT EXISTING PROPOSED CHANGE LOT: 3 ±38,685 S.F. ±38,685 S.F. 0 S.F. SUBLOT: ----- DRAWN BY: AB/ JC CHECKED: JCA/PMB TREE CHART PROJECT: ALEXANDER-2108 ALBANY DATE: SEPTEMBER 23, 2026 TREES TO BE REMOVED TREES TO BE PLANTED PATRICK M. BELL, P.E. JOB #: 260812 LICENSE #087679 11 12 LANDSCAPE PLANTING CHART SIZE APPROXIMATE TREE LINE C N N QUANTITY SYMBOL BOTANICAL NAME COMMON NAME CALIPER HEIGHT VOLUME COMMENTS N N N (IN.) (FT.) (GAL.) NAL N N N C N L N 2 SM 'ACER SACCHARUM' SUGAR MAPLE 3" ----- ----- SEE PLAN FOR (914) 736-3664 LOCATIONS SEE PLAN FOR 2 RO 'QUERCUS RUBRA' RED OAK 3" ---- ----- LOCATIONS 39 Arlo Lane SEE PLAN FOR 2 RB 'BETULA NIGRA' RIVER BIRCH 3" ---- ----- LOCATIONS Cortlandt Manor, New York 10567 SEE PLAN FOR 2 ER 'CERCIS CANADENSIS' EASTERN REDBUD 3" ---- ---- LOCATIONS 2 DW 'CORNUS FLORIDA' FLOWERING DOGWOOD 3" ---- ---- SEE PLAN FOR LOCATIONS SITE DEVELOPMENT PLAN SEE PLAN FOR 2 BG 'NYSSA SYLVATICA' BLACK GUM 3" ---- ---- LOCATIONS SITE DEVELOPMENT PLAN FOR 2108 ALBANY POST ROAD LOCATION: 2108 ALBANY POST ROAD TOWN OF CORTLANDT, NEW YORK SUGAR MAPLE RED OAK RIVER BIRCH EASTERN REDBUD FLOWERING DOGWOOD BLACK GUM SHEET 2 OF 3 SP-1.1 Page 63 LANDSCAPING NOTES FILTER X, MIRAFI 100X, OR STABILINKA T140N FILTER 10' MAX. CLOTH OR APPROVED EQUAL 1. ALL LANDSCAPING (PLANTING OF TREES, SHRUBS, SOD, ETC.) SHALL BE PERFORMED BY OR UNDER THE WOVEN WIRE FENCE (MIN. 14 12 6" SUPERVISION OF A PERSON WHO MEETS AT LEAST ONE OF THE FOLLOWING CRITERIA: CERTIFIED NURSERY GAUGE W/ MAX 6" MESH SPACING MAX. PROFESSIONAL, ISA CERTIFIED ARBORIST, CERTIFIED LANDSCAPE TECHNICIAN PROGRAM OR GRADUATE AS DEEMED NECESSARY BY NOTES: FROM A 2 YEAR COLLEGE IN THE FIELD OF HORTICULTURE, ENVIRONMENTAL SCIENCE, LANDSCAPE QUALIFIED INSPECTOR.) 1. ALL PROPOSED SIGNS AND POSTS ARCHITECTURE OR FORESTRY. 2" X 2" WOOD POST, NO. 2 TO BE IN ACCORDANCE WITH FEDERAL 6" 2. ALL PLANTS MUST BE HEALTHY AND REPRESENTATIVE OF THE FORM OF THE SPECIES. RE-BAR OR STEEL PICKETS MAX. REGULATIONS AS MUCH AS APPROPRIATE. 3. TREES TO BE PLANTED IMMEDIATELY AFTER DELIVERY FROM THE NURSERY. 2. ROAD NAME SIGNS SHALL BE AS INDUSTRIES SIGN POST SYTEMS OR APPROVED EQUAL (BREAKAWAY 'U' SPECIFIED BY THE CITY OF PEEKSKILL. TRAFFIC SIGN POST = FRANKLIN 4. CONTRACTOR TO ASSURE SUITABLE SOIL CONDITION, IF NECESSARY PROVIDE ORGANIC MATTER-COMPOST, NUTRIFIED BARK, IN THE PROPORTION OF 2 PARTS OF SOIL TO 1 PART OF ORGANIC MATTER. MIN. 30" 5. WATERING BASIN FOR TREES TO BE AT LEAST 30" IN DIAMETER OR THREE TIMES THE SIZE OF THE ROOTBALL. FL O W FILTER X, MIRAFI 100X, OR SITE 6. BACKFILLING OF PLANT BASIN TO BE WITH THE ORIGINAL SOIL TO THE LEVEL OF 2 TO 4 INCHES ABOVE THE STABILINKA T140N FILTER VARIES 7'-0" ORIGINAL LEVEL. CLOTH OR APPROVED EQUAL 2' (MIN.) WOVEN WIRE FENCE (MIN. 14 12 GAUGE W/ CHANNEL POST) 7. PROVIDE APPROPRIATE WATERING AND IF NECESSARY WRAP THE TRUNK TO LIMIT DAMAGE FROM INSECTS. MAX 6" MESH (AS DEEMED NECESSARY BY MIN. 18" 6" QUALIFIED INSPECTOR.) 8. ALL STAKING AND PIT DETAILS SHALL BE IN ACCORDANCE WITH THE NYS STANDARD SHEETS SECTION 611-1R1 MIN. 9. CONTRACTOR TAKES ALL RESPONSIBILITY FOR MAINTAINING A SAFE CONSTRUCTION AND 2" X 2" WOOD POST, NO. 2 TOE-IN FILTER FABRIC, RE-BAR OR STEEL PICKETS POST-CONSTRUCTION CONDITION. BACKFILL AND TAMP SOIL TO 10. A GRASS SEEDING MIXTURE FOR THE PROPOSED LAWN AREAS WILL BE 50% KENTUCKY BLUE, 25% PERENNIAL SECURE FABRIC IN PLACE FRONT VIEW FINISHED GRADE RYE AND 25% FINE OR RED FESCUE. SECTION VIEW 11. TOPSOIL REMOVED SHALL BE REPLACED TO A DEPTH OF AT LEAST 4-INCHES OVER ALL EXPOSED GROUND ROADWAY SURFACES EXCEPT ROCK, AND SHALL BE PLANTED OR SEEDED AND MULCHED REPEATEDLY UNTIL THE AREA FILTER X, MIRAFI 100X, OR IS STABILIZED. STABILINKA T140N FILTER CURB CLOTH OR APPROVED EQUAL 12. ALL TREES WHICH FAIL TO SURVIVE FOR A PERIOD OF TWO CALENDAR YEARS SHALL BE REPLACED BY PERMIT LOCATION MAP 3'-0" HOLDER AT NO EXPENSE TO TOWN OF OWNER OF THE LAND, IF OTHER THAN THE PERMIT HOLDER OF THE WOVEN WIRE FENCE (MIN. 14 12 CONCRETE SCALE: 1" = 300' PERMIT. SAID REPLACEMENT SHALL BE WITHIN 60 DAYS FOLLOWING WRITTEN DEMAND FOR SUCH GAUGE W/ MAX 6" MESH SPACING FOOTING REPLACEMENT FROM THE DIRECTOR OF TECHNICAL SERVICES OR WRITTEN EXTENDED PERIOD OF TIME AS AS DEEMED NECESSARY BY MAY BE SPECIFIED. QUALIFIED INSPECTOR.) 3,500 PSI MIN. EXISTING / FINAL GRADE 6" OW FL EROSION AND SEDIMENT CONTROL NOTES 1'Ø 1) CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SEDIMENT AND EROSION CONTROL JOINING SECTIONS PRACTICES. THE SEDIMENT AND EROSION CONTROL PRACTICES ARE TO BE INSTALLED PRIOR TO ANY TOP VIEW TRAFFIC SIGN POLE N.T.S. MAJOR SOIL DISTURBANCES, AND MAINTAINED UNTIL PERMANENT PROTECTION IS ESTABLISHED. 2) TIMELY MAINTENANCE OF SEDIMENT CONTROL STRUCTURES IS THE RESPONSIBILITY OF THE TOE-IN FILTER FABRIC, CONTRACTOR. ALL STRUCTURES SHALL BE MAINTAINED IN GOOD WORKING ORDER AT ALL TIMES. THE BACKFILL AND TAMP SOIL TO SEDIMENT LEVEL IN ALL SEDIMENT TRAPS SHALL BE CLOSELY MONITORED AND SEDIMENT REMOVED SECURE FABRIC IN PLACE PROMPTLY WHEN MAXIMUM LEVELS ARE REACHED OR AS ORDERED BY THE ENGINEER. ALL SEDIMENT CONTROL STRUCTURES SHALL BE INSPECTED WEEKLY, PRIOR TO EXPECTED RAIN EVENTS, AND AFTER ISOMETRIC VIEW. OW FL EACH HEAVY RAIN TO INSURE PROPER OPERATION AS DESIGNED. AN INSPECTION SCHEDULE SHALL BE 6" X 6" X 6" TRENCH SET FORTH PRIOR TO THE START OF CONSTRUCTION. 3) THE LOCATIONS AND THE INSTALLATION TIMES OF THE SEDIMENT CAPTURING STANDARDS SHALL BE INSTALLATION NOTES: AS ORDERED BY THE ENGINEER, AND IN ACCORDANCE WITH ACCEPTED STANDARDS. 1. EXCAVATE A 4 INCH X 4 INCH TRENCH ALONG THE LOWER SIDE OF A SLOPE AS SPECIFIED ON SITE PLAN. 2. UNROLL A SECTION AT A TIME AND POSITION THE POSTS AGAINST THE BACK (DOWNHILL) WALL OF THE 4) ALL TOPSOIL NOT TO BE USED FOR FINAL GRADING SHALL BE REMOVED FROM THE SITE IMMEDIATELY TRENCH (NET SIDE AWAY FROM DIRECTION OF STORM WATER FLOW). AND PLACED IN A STABILIZED STOCKPILE OR FILL AREA. ALL TOPSOIL REQUIRED FOR FINAL GRADING 3. DRIVE THE POST INTO THE GROUND UNTIL THE NETTING IS APPROXIMATELY 2 INCHES FROM THE TRENCH AND STORED ON SITE SHALL BE LIMED,FERTILIZED, TEMPORARILY SEEDED AND MULCHED WITHIN 14 BOTTOM. DAYS. 4. LAY THE TOE-IN FLAP OF FABRIC FLAT IN THE BOTTOM OF THE TRENCH AND BACKFILL THE TRENCH AND TAMP THE SOIL OVER THE FLAP TO SECURELY HOLD THE FABRIC IN PLACE. STEEPER SLOPES REQUIRE AN 5) ANY DISTURBED AREAS THAT WILL BE LEFT EXPOSED MORE THAN 14 DAYS AND NOT SUBJECT TO INTERCEPT TRENCH. 5. JOIN SECTIONS AS SHOWN ABOVE CONSTRUCTION TRAFFIC, SHALL IMMEDIATELY RECEIVE TEMPORARY SEEDING. MULCH SHALL BE USED 6. PREFABRICATED UNITS SHALL BE OF TYPE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. IF THE SEASON PREVENTS THE ESTABLISHMENT OF A TEMPORARY COVER. DISTURBED AREAS SHALL BE LIMED AND FERTILIZED PRIOR TO TEMPORARY SEEDING. SILT FENCE INSTALLATION N.T.S. 6) ALL DISTURBED AREAS WITHIN 500 FEET OF AN INHABITED DWELLING SHALL BE WETTED AS NECESSARY TO PROVIDE DUST CONTROL. OWNER/APPLICANT 7) THE CONTRACTOR SHALL KEEP THE ROADWAYS WITHIN THE PROJECT CLEAR OF SOIL AND DEBRIS AND IS RESPONSIBLE FOR ANY STREET CLEANING NECESSARY DURING THE COURSE OF THE PROJECT. 8) SEDIMENT AND EROSION CONTROL STRUCTURES SHALL BE REMOVED AND THE AREA STABILIZED WHEN KRD PROPERTIES, LLC THE DRAINAGE AREA HAS BEEN PROPERLY STABILIZED BY PERMANENT MEASURES. P.O. BOX 891 9) SOIL SEEDING AND FERTILIZER AMENDMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THE FORT MONTGOMERY, NY 10922 CURRENT EDITION OF "NEW YORK STATE STANDARDS AND SPECIFICATIONS FOR EROSION AND DBA HUDSON VALLEY MOTORCYCLE SEDIMENT CONTROL". 10) ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION OF "NEW YORK GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL". · UNDER NEW YORK STATE EDUCATIONAL LAW ARTICLE 145, SECTION 7209 (2), IT IS UNLAWFUL FOR ANY PERSON TO ALTER ANY ITEM ON THIS DRAWING, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. IF ANY ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DO NOT CUT LEADER SIGNAGE · COPYRIGHT "2026" BY CRONIN ENGINEERING. ALL RIGHTS RESERVED. 6" (see detail) 1/4" PER FT. MIN SLOPE (SEE DETAIL) REMOVE ENOUGH WHOLE BRANCHES TO REDUCE FOLIAGE BY 13 (ALWAYS PRUNE STANDARD HANDICAP CONC. CURB REVISIONS TO NODE OR CROTCH RETAINING NORMAL PLANT SHAPE) SPACE SPACE CLASS A CONC. 2" TOP COURSE - ASPHALTIC CONC. NYSDOT ITEM #403.1701 3" BINDER COURSE - ASPHALTIC CONC NYSDOT ITEM #403.13 (INSTALLED IN 3" LIFTS) WHEEL 8" BASE COURSE - NYSDOT ITEM #304.05 (INSTALLED IN 4" LIFTS) COMPACTED SUBGRADE TO BE INSTALLED IN 6" LIFTS AND STOP COMPACTED TO 95% OF THE STANDARD PROCTOR MAX. DENSITY EXPANSION JOINT 4" WHITE 3/4" CRUSHED STONE 2 STRANDS OF NO. 12 GALVANIZED ANEALED UNDISTURBED EARTH STEEL WIRE (TWISTED IN NEW RUBBER HOSE) STRIPE # REASON DATE CIRCLED WATERPROOF TREE WRAPPING PAPER MUNICIPAL TAX IDENTIFICATION: 4" SIDE (TO HAVE A 50% OVERLAP TIED WITH STOUT ON-SITE ASPHALT PAVING SECTION AND 6' MAX. SMALL TREE N.T.S. 18' 7' MIN. LARGE TREE HEMPCORD AT TOP OF BALL AND ALSO AT HEIGHEST CONCRETE CURB DETAIL SECTION: 54.12 OF 2ND BRANCHES 3"Ø MIN. CEDAR STAKE. TO BE 3' MIN. LONG AND PROTRUDE INTO VIRGIN OR COMPACTED BLOCK: 3 SOIL A MINIMUM OF 16" IN ELEVATION BELOW 4" MIN. THE BOTTOM OF OF THE EXCAVATED TREE BALL HOLE. LOT: 3 (STAKES TO BE DRIVEN IN AFTER TENSION HAS BEEN PLACED AROUND TREE TRUNK) SUBLOT: ----- ACCESS AISLE DRAWN BY: AB/ JC 6" MIN. TOPSOIL MIX BACKFILL ALONG INTERNATIONAL CHECKED: JCA/PMB SIDES OF ROOT BALL (12" MIN) SYMBOL OF PROJECT: ALEXANDER-2108 ALBANY ACCESSIBILITY CUT AND REMOVE BURLAP BINDING FROM 9' 9' 8' MIN. DATE: SEPTEMBER 23, 2026 THE TOP 13 OF THE ROOT BALL AND COMPLETELY PATRICK M. BELL, P.E. 6" MIN. FROM THE TRUNK OF THE TREE. (IF REQUIRED) JOB #: 260812 LICENSE #087679 TAMPED TOPSOIL MIX BELOW PARKING STALL DETAIL N.T.S. 1' MIN. 1' MIN. ROOT BALL (6" MIN) DECIDUOUS TREE PLANTING N.T.S. C N N N N N 48" HDPE ORANGE NAL N N N C N L N SAFETY FENCE WHITE SPRUCE INSTALLATION NOTES WIRE OR ZIP TIES TO SECURE (914) 736-3664 SAFETY FENCE IN PLACE 0" 6'- 1. SPACE SUPPORT FENCE POSTS AT 6'-0" 90" STANDARD STEEL OR WOODEN POST DRIVEN TO INTERVALS. 42" MIN. BELOW GRADE FINISHED GRADE 39 Arlo Lane 2. DRIVE SUPPORT POSTS 42" INTO GROUND. Cortlandt Manor, New York 10567 3. FIRMLY FASTEN FENCE MATERIAL IN PLACE BY WIRING OR ZIP TYING TO FENCE POST WHILE MAINTAINING TENSION ACROSS FULL HEIGHT OF FENCE. WIRING OR ZIP TYING SHALL BE DONE IN A MANNER THAT WILL PREVENT SAGGING OF CONSTRUCTION DETAILS FENCE MATERIAL. 4. PROVIDE PERIODIC INSPECTION AND MAINTENANCE OF FENCE INCLUDING REPAIRS AS NECESSARY AND REQUIRED. CONCRETE WASHOUT BIN DETAIL SITE DEVELOPMENT PLAN 5. PLASTIC FENCE MATERIAL SHALL BE MORNING BARRIER FENCE, COLOR-INTERNATIONAL FOR ORANGE, AS MANUFACTURED BY ADPI ENTERPRISES, INC. OR APPROVED EQUAL. BLOW UP VIEW CATCH BASIN FILTER SOCK 2108 ALBANY POST ROAD ISOMETRIC VIEW LOCATION: CONSTRUCTION SAFETY FENCE INSTALLATION NTS 2108 ALBANY POST ROAD TOWN OF CORTLANDT, NEW YORK SHEET 3 OF 3 SP-1.2 Page 64 2108 Albany Post Road Joseph G. Thompson Architect, PLLC 10 8 N Divi sion Str ee t, S ui te 1 00 Peekskill, New York 10566 TOWN OF CORTLANDT - WESTCHESTER COUNTY NOTES: IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. G . THOM PH E PS JOS ON 036057 SEAL Joseph G. Thompson, RA New York State License #036057 2108 Albany Post Road FOR PLANNING BOARD REVIEW & APPROVAL Town of Cortlandt - Westchester County KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road S-B-L: 54.12-3-3 DRAWING INDEX: GENERAL: Date: September 23, 2026 G0.01 TITLE SHEET Revisions: EXISTING / DEMOLITION: AX1.01 FIRST FLOOR DEMO PLAN AX2.01 EXISTING ELEVATIONS ARCHITECTURAL: A1.01 FIRST FLOOR ARCHITECTURAL PLAN A2.01 NEW ELEVATIONS A5.01 DETAILS G0.01 Page 65 Wall Indication Legend Joseph G. Thompson Architect, PLLC 1 08 N Divisio n S tre et, Su ite 10 0 Peekskill, New York 10566 NOTES: EXISTING SHED IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION EXISTING EXISTING "ALTERED BY" FOLLOWED BY HIS MEN'S WOMEN'S SIGNATURE AND THE DATE OF SUCH RESTROOM RESTROOM ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. G . THOM PH E PS JOS ON EXISTING EXISTING EXISTING EXISTING WORK SPACE WORK SPACE WORK SPACE WORK SPACE 4,919 +/- SQ FT 3,971 +/- SQ FT 2,932 +/- SQ FT 4,712 +/- SQ FT 036057 SEAL Joseph G. Thompson, RA New York State License #036057 EXISTING OFFICE 2108 Albany Post Road FOR PLANNING BOARD REVIEW & APPROVAL EXISTING EXISTING OFFICE WORK SPACE 5,525 +/- SQ FT EXIST OFFICE EXISTING EXISTING CONFERENCE HALL ROOM EXIST EXIST EXIST CL CL CL Town of Cortlandt - Westchester County EXIST EXIST OFFICE OFFICE KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road ∅ EXIST EXIST EXIST EXIST S-B-L: 54.12-3-3 CL CL OFFICE HALL EXIST BATH Date: September 23, 2026 Revisions: 1 Existing First Floor Architectural Demo Plan (24,651 +/- Gross SF) AX1.01 Scale: 3/32" = 1'-0" AX1.01 Page 66 Joseph G. Thompson Architect, PLLC 1 08 N Divisio n S tre et, Su ite 10 0 Peekskill, New York 10566 NEW PARTS STORAGE 33'-1" X 30'-7" NOTES: EXISTING SHED IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION EXISTING EXISTING NEW "ALTERED BY" FOLLOWED BY HIS MEN'S WOMEN'S NEW RESTROOM RESTROOM NEW CL SIGNATURE AND THE DATE OF SUCH BATTERY STORAGE 4'-0" X 5'-0" ALTERATION, AND A SPECIFIC STORAGE 19'-8" X 18'-0" DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. NEW BIKE STORAGE G . THOM PH NEW BIKE STORAGE E PS JOS ON NEW NEW PARTS STORAGE BIKE STORAGE DEPARTMENT 036057 SEAL Joseph G. Thompson, RA New York State License #036057 NEW WHITE NEW PHOTO OFFICE ROOM 10' X 10' 10' X 10' NEW OFFICE 18'-9" X 20'-9" NEW NEW WOMEN'S MEN'S RESTROOM RESTROOM NEW SERVICE NEW IT CL DROP OFF / 9'-1" X 4'-0" WRITE UP NEW NEW NEW OFFICE OFFICE NEW MANAGER'S 11'-6" X 8'-2" 11'-6" X 8'-2" CONF ROOM OFFICE 18'-0" X 12'-0" 17'-7" X 12'-0" 2108 Albany Post Road FOR PLANNING BOARD REVIEW & APPROVAL NEW NEW SERVICE BIKE STORAGE DEPARTMENT NEW NEW MEZZANINE SHOWROOM ABOVE 2,265 SF Town of Cortlandt - Westchester County KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road NEW BREAK ROOM 12'-1" X 12'-0" S-B-L: 54.12-3-3 NEW RESTROOM PARKING REQUIREMENTS Use Parking Requirements Quantity Spaces Required Date: September 23, 2026 Showroom Revisions: Storage Workshop Offices Total 1 New First Floor Architectural Plan (24,890 +/- Gross SF + 2,265 SF New Mezzanine) A1.01 Scale: 3/32" = 1'-0" A1.01 Page 67 Joseph G. Thompson Architect, PLLC 10 8 N Divi sion Str ee t, S ui te 1 00 Peekskill, New York 10566 NOTES: IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC 1 Existing Northwest Elevation DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. AX2.01 Scale: 1/8" = 1'-0" WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. G . THOM PH E PS JOS ON 036057 SEAL Joseph G. Thompson, RA New York State License #036057 2 Existing Northeast Elevation AX2.01 Scale: 1/8" = 1'-0" 2108 Albany Post Road FOR PLANNING BOARD REVIEW & APPROVAL Town of Cortlandt - Westchester County 3 Existing Southeast Elevation AX2.01 Scale: 1/8" = 1'-0" KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road S-B-L: 54.12-3-3 Date: September 23, 2026 Revisions: 4 Existing Southwest Elevation AX2.01 Scale: 1/8" = 1'-0" AX2.01 Page 68 Signage Table Sign Type: Area: Facade Sign 42.0 Sq Ft DUCATI Suzuki DUCATI Kawasaki Facade Sign 36.0 Sq Ft HUDSON VALLEY MOTORCYCLES Hudson Valley Motorcycles Facade Sign 53.4 Sq Ft Joseph G. Thompson Architect, PLLC SERVICE 10 8 N Divi sion Str ee t, S ui te 1 00 Peekskill, New York 10566 Hudson Valley Motorcycles Freestanding Sign 24.0 Sq Ft Service Canopy Sign 7.6 Sq Ft Ducati Facade Sign 94.1 Sq Ft NOTES: IT IS A VIOLATION OF THE LAW FOR Ducati Projecting Wall Sign 4.0 Sq Ft ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN Total: 261.1 Sq Ft * ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION * Total exceeds the maximum of 80 square feet of total signage allowable "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH per the Town of Cortlandt Zoning Code Chapter 245, Attachment 1, Table 1. ALTERATION, AND A SPECIFIC 1 New Northwest Elevation DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. A2.01 Scale: 1/8" = 1'-0" WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. G . THOM PH E PS JOS ON SUZUKI Kawasaki 036057 SEAL Joseph G. Thompson, RA DUCATI SERVICE New York State License #036057 2 New Northeast Elevation A2.01 Scale: 1/8" = 1'-0" 2108 Albany Post Road FOR PLANNING BOARD REVIEW & APPROVAL Town of Cortlandt - Westchester County 3 New Southeast Elevation A2.01 Scale: 1/8" = 1'-0" KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road S-B-L: 54.12-3-3 Date: September 23, 2026 DUCATI Revisions: SERVICE 4 New Southwest Elevation A2.01 Scale: 1/8" = 1'-0" A2.01 Page 69 Signage Table Kawasaki Sign Type: Area: Suzuki Facade Sign 42.0 Sq Ft Kawasaki Facade Sign 36.0 Sq Ft SUZUKI Hudson Valley Motorcycles Facade Sign 53.4 Sq Ft Joseph G. Thompson Architect, PLLC 10 8 N Divi sion Str ee t, S ui te 1 00 Peekskill, New York 10566 Hudson Valley Motorcycles Freestanding Sign 24.0 Sq Ft Service Canopy Sign 7.6 Sq Ft Ducati Facade Sign 94.1 Sq Ft NOTES: IT IS A VIOLATION OF THE LAW FOR Ducati Projecting Wall Sign 4.0 Sq Ft ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A 1 Facade Sign Detail (42.0 +/- SF) 2 Facade Sign Detail (36.0 +/- SF) Total: 261.1 Sq Ft * LICENSED ARCHITECT OR ENGINEER, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS A5.01 Scale: 1/2" = 1'-0" A5.01 Scale: 1/2" = 1'-0" ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO HIS ITEM THE SEAL AND THE NOTATION * Total exceeds the maximum of 80 square feet of total signage allowable "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH per the Town of Cortlandt Zoning Code Chapter 245, Attachment 1, Table 1. ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. © JOSEPH G THOMPSON ARCHITECT, PLLC. ALL RIGHTS RESERVED. G . THOM PH HUDSON VALLEY MOTORCYCLES E PS JOS ON 036057 SEAL Joseph G. Thompson, RA 3 Facade Sign Detail (53.4 +/- SF) New York State License #036057 A5.01 Scale: 1/2" = 1'-0" HUDSON VALLEY SERVICE MOTORCYCLES 2108 Albany Post Road 4 Freestanding Sign Detail (24 +/- SF) 5 Canopy Sign Detail (7.6 +/- SF) FOR PLANNING BOARD REVIEW & APPROVAL A5.01 Scale: 1/2" = 1'-0" A5.01 Scale: 1/2" = 1'-0" DUCATI DUCATI Town of Cortlandt - Westchester County KRD Properties, LLC - Owner Montrose, New York 10548 2108 Albany Post Road S-B-L: 54.12-3-3 6 Facade Sign Detail (94.1+/- SF) A5.01 Scale: 1/2" = 1'-0" Date: September 23, 2026 Revisions: DUCATI SERVICE 7 Projecting Wall Sign Detail (4.0 +/- SF) A5.01 Scale: 1/2" = 1'-0" A5.01